Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Magn Reson Med ; 91(6): 2417-2430, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38291598

RESUMO

PURPOSE: Recent work has shown MRI is able to measure and quantify signals of phospholipid membrane-bound protons associated with myelin in the human brain. This work seeks to develop an improved technique for characterizing this brain ultrashort- T 2 ∗ $$ {\mathrm{T}}_2\ast $$ component in vivo accounting for T 1 $$ {\mathrm{T}}_1 $$ weighting. METHODS: Data from ultrashort echo time scans from 16 healthy volunteers with variable flip angles (VFA) were collected and fitted into an advanced regression model to quantify signal fraction, relaxation time, and frequency shift of the ultrashort- T 2 ∗ $$ {\mathrm{T}}_2\ast $$ component. RESULTS: The fitted components show intra-subject differences of different white matter structures and significantly elevated ultrashort- T 2 ∗ $$ {\mathrm{T}}_2\ast $$ signal fraction in the corticospinal tracts measured at 0.09 versus 0.06 in other white matter structures and significantly elevated ultrashort- T 2 ∗ $$ {\mathrm{T}}_2\ast $$ frequency shift in the body of the corpus callosum at - $$ - $$ 1.5 versus - $$ - $$ 2.0 ppm in other white matter structures. CONCLUSION: The significantly different measured components and measured T 1 $$ {\mathrm{T}}_1 $$ relaxation time of the ultrashort- T 2 ∗ $$ {\mathrm{T}}_2\ast $$ component suggest that this method is picking up novel signals from phospholipid membrane-bound protons.


Assuntos
Encéfalo , Prótons , Humanos , Voluntários Saudáveis , Imagens de Fantasmas , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Fosfolipídeos
2.
J Magn Reson Imaging ; 2023 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-37702305

RESUMO

BACKGROUND: The polyarticular nature of Osteoarthritis (OA) tends to manifest in multi-joints. Associations between cartilage health in connected joints can help identify early degeneration and offer the potential for biomechanical intervention. Such associations between hip and knee cartilages remain understudied. PURPOSE: To investigate T1p associations between hip-femoral and acetabular-cartilage subregions with Intra-limb and Inter-limb patellar cartilage; whole and deep-medial (DM), deep-lateral (DL), superficial-medial (SM), superficial-lateral (SL) subregions. STUDY TYPE: Prospective. SUBJECTS: Twenty-eight subjects (age 55.1 ± 12.8 years, 15 females) with none-to-moderate hip-OA while no radiographic knee-OA. FIELD STRENGTH/SEQUENCE: 3-T, bilateral hip, and knee: 3D-proton-density-fat-saturated (PDFS) Cube and Magnetization-Prepared-Angle-Modulated-Partitioned-k-Space-Spoiled-Gradient-Echo-Snapshots (MAPSS). ASSESSMENT: Ages of subjects were categorized into Group-1 (≤40), Group-2 (41-50), Group-3 (51-60), Group-4 (61-70), Group-5 (71-80), and Group-6 (≥81). Hip T1p maps, co-registered to Cube, underwent an atlas-based algorithm to quantify femoral and acetabular subregional (R2 -R7 ) cartilage T1p . For knee Cube, a combination of V-Net architectures was used to segment the patellar cartilage and subregions (DM, DL, SM, SL). T1p values were computed from co-registered MAPSS. STATISTICAL TESTS: For Intra-and-Inter-limb, 5 optimum predictors out of 13 (Hip subregional T1p , age group, gender) were selected by univariate linear-regression, to predict outcome (patellar T1p ). The top five predictors were stepwise added to six linear mixed-effect (LME) models. In all LME models, we assume the data come from the same subject sharing the same random effect. The best-performing models (LME-modelbest ) selected via ANOVA, were tested with DM, SM, SL, and DL subregional-mean T1p . LME assumptions were verified (normality of residuals, random-effects, and posterior-predictive-checks). RESULTS: LME-modelbest (Intra-limb) had significant negative and positive fixed-effects of femoral-R5 and acetabular-R2 T1p , respectively (conditional-R2 = 0.581). LME-modelbest (Inter-limb) had significant positive fixed-effects of femoral-R3 T1p (conditional-R2 = 0.26). DATA CONCLUSION: Significant positive and negative T1p associations were identified between load-bearing hip cartilage-subregions vs. ipsilateral and contralateral patellar cartilages respectively. The effects were localized on medial subregions of Inter-limb, in particular. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 1.

3.
Pain Med ; 24(Suppl 1): S149-S159, 2023 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-36943371

RESUMO

OBJECTIVES: To evaluate whether combining fast acquisitions with deep-learning reconstruction can provide diagnostically useful images and quantitative assessment comparable to standard-of-care acquisitions for lumbar spine magnetic resonance imaging (MRI). METHODS: Eighteen patients were imaged with both standard protocol and fast protocol using reduced signal averages, each protocol including sagittal fat-suppressed T2-weighted, sagittal T1-weighted, and axial T2-weighted 2D fast spin-echo sequences. Fast-acquisition data was additionally reconstructed using vendor-supplied deep-learning reconstruction with three different noise reduction factors. For qualitative analysis, standard images as well as fast images with and without deep-learning reconstruction were graded by three radiologists on five different categories. For quantitative analysis, convolutional neural networks were applied to sagittal T1-weighted images to segment intervertebral discs and vertebral bodies, and disc heights and vertebral body volumes were derived. RESULTS: Based on noninferiority testing on qualitative scores, fast images without deep-learning reconstruction were inferior to standard images for most categories. However, deep-learning reconstruction improved the average scores, and noninferiority was observed over 24 out of 45 comparisons (all with sagittal T2-weighted images while 4/5 comparisons with sagittal T1-weighted and axial T2-weighted images). Interobserver variability increased with 50 and 75% noise reduction factors. Deep-learning reconstructed fast images with 50% and 75% noise reduction factors had comparable disc heights and vertebral body volumes to standard images (r2≥ 0.86 for disc heights and r2≥ 0.98 for vertebral body volumes). CONCLUSIONS: This study demonstrated that deep-learning-reconstructed fast-acquisition images have the potential to provide noninferior image quality and comparable quantitative assessment to standard clinical images.


Assuntos
Aprendizado Profundo , Humanos , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Tecnologia
4.
Pain Med ; 24(Suppl 1): S81-S94, 2023 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-36069660

RESUMO

Management of patients suffering from low back pain (LBP) is challenging and requires development of diagnostic techniques to identify specific patient subgroups and phenotypes in order to customize treatment and predict clinical outcome. The Back Pain Consortium (BACPAC) Research Program Spine Imaging Working Group has developed standard operating procedures (SOPs) for spinal imaging protocols to be used in all BACPAC studies. These SOPs include procedures to conduct spinal imaging assessments with guidelines for standardizing the collection, reading/grading (using structured reporting with semi-quantitative evaluation using ordinal rating scales), and storage of images. This article presents the approach to image acquisition and evaluation recommended by the BACPAC Spine Imaging Working Group. While the approach is specific to BACPAC studies, it is general enough to be applied at other centers performing magnetic resonance imaging (MRI) acquisitions in patients with LBP. The herein presented SOPs are meant to improve understanding of pain mechanisms and facilitate patient phenotyping by codifying MRI-based methods that provide standardized, non-invasive assessments of spinal pathologies. Finally, these recommended procedures may facilitate the integration of better harmonized MRI data of the lumbar spine across studies and sites within and outside of BACPAC studies.


Assuntos
Degeneração do Disco Intervertebral , Dor Lombar , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/patologia , Região Lombossacral , Dor Lombar/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
5.
Magn Reson Med ; 87(2): 733-745, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34590728

RESUMO

PURPOSE: To validate the potential of quantifying R2 -R1ρ using one pair of signals with T1ρ preparation and T2 preparation incorporated to magnetization-prepared angle-modulated partitioned k-space spoiled gradient-echo snapshots (MAPSS) acquisition and to find an optimal preparation time (Tprep ) for in vivo knee MRI. METHODS: Bloch equation simulations were first performed to assess the accuracy of quantifying R2 -R1ρ using T1ρ - and T2 -prepared signals with an equivalent Tprep . For validation of this technique in comparison to the conventional approach that calculates R2 -R1ρ after estimating both T2 and T1ρ , phantom experiments and in vivo validation with five healthy subjects and five osteoarthritis patients were performed at a clinical 3T scanner. RESULTS: Bloch equation simulations demonstrated that the accuracy of this efficient R2 -R1ρ quantification method and the optimal Tprep can be affected by image signal-to-noise ratio (SNR) and tissue relaxation times, but quantification can be closest to the reference with an around 25 ms Tprep for knee cartilage. Phantom experiments demonstrated that the proposed method can depict R2 -R1ρ changes with agarose gel concentration. With in vivo data, significant correlation was observed between cartilage R2 -R1ρ measured from the conventional and the proposed methods, and a Tprep of 25.6 ms provided the most agreement by Bland-Altman analysis. R2 -R1ρ was significantly lower in patients than in healthy subjects for most cartilage compartments. CONCLUSION: As a potential biomarker to indicate cartilage degeneration, R2 -R1ρ can be efficiently measured using one pair of T1ρ -prepared and T2 -prepared signals with an optimal Tprep considering cartilage relaxation times and image SNR.


Assuntos
Cartilagem Articular , Osteoartrite do Joelho , Cartilagem , Cartilagem Articular/diagnóstico por imagem , Humanos , Joelho , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Osteoartrite do Joelho/diagnóstico por imagem , Imagens de Fantasmas
6.
NMR Biomed ; 34(1): e4399, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32844496

RESUMO

Although combined spin- and gradient-echo (SAGE) dynamic susceptibility-contrast (DSC) MRI can provide perfusion quantification that is sensitive to both macrovessels and microvessels while correcting for T1 -shortening effects, spatial coverage is often limited in order to maintain a high temporal resolution for DSC quantification. In this work, we combined a SAGE echo-planar imaging (EPI) sequence with simultaneous multi-slice (SMS) excitation and blipped controlled aliasing in parallel imaging (blipped CAIPI) at 3 T to achieve both high temporal resolution and whole brain coverage. Two protocols using this sequence with multi-band (MB) acceleration factors of 2 and 3 were evaluated in 20 patients with treated gliomas to determine the optimal scan parameters for clinical use. ΔR2 *(t) and ΔR2 (t) curves were derived to calculate dynamic signal-to-noise ratio (dSNR), ΔR2 *- and ΔR2 -based relative cerebral blood volume (rCBV), and mean vessel diameter (mVD) for each voxel. The resulting SAGE DSC images acquired using MB acceleration of 3 versus 2 appeared visually similar in terms of image distortion and contrast. The difference in the mean dSNR from normal-appearing white matter (NAWM) and that in the mean dSNR between NAWM and normal-appearing gray matter were not statistically significant between the two protocols. ΔR2 *- and ΔR2 -rCBV maps and mVD maps provided unique contrast and spatial heterogeneity within tumors.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Meios de Contraste/química , Imagem Ecoplanar , Glioma/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Perfusão , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão Sinal-Ruído , Adulto Jovem
7.
Eur Spine J ; 30(9): 2549-2556, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33547944

RESUMO

PURPOSE: Vertebral endplate bone marrow lesions ("Modic changes", MC) are associated with chronic low back pain (CLBP). Bone marrow composition in MC is poorly understood. The goals of this study were to: (1) measure bone marrow fat fraction (BMF) in CLBP patients with MC using water-fat MRI and (2) assess the relationship between BMF measurements and patient-reported clinical characteristics. METHODS: In this cross-sectional study, 42 CLBP patients (men, n = 21; age, 48 ± 12.4 years) and 18 asymptomatic controls (men, n = 10; 42.7 ± 12.8 years) underwent 3 T MRI between January 2016 and July 2018. Imaging consisted of T1- and T2-weighted sequences to evaluate MC and spoiled gradient-recalled echo sequence with asymmetric echoes and least-squares fitting to measure BMF. BMF was compared between vertebrae with and without MC using mixed effects models. The relationship between the BMF measurements and patient-reported disability scores was examined using regression. RESULTS: Twenty-seven subjects (26 CLBP, 1 control) had MC, and MC presence coincided with significantly altered BMF. In MC 1, BMF was lower than endplates without MC (absolute difference -22.3%; p < 0.001); in MC 2, BMF was higher (absolute difference 21.0%; p < 0.001). Absolute BMF differences between affected and unaffected marrow were larger in patients with greater disability (p = 0.029-0.032) and were not associated with pain (p = 0.49-0.83). CONCLUSION: BMF is significantly altered in MC. Water-fat MRI enables BMF measurements that may eventually form the basis for quantitative assessments of MC severity and progression.


Assuntos
Medula Óssea , Água , Adulto , Medula Óssea/diagnóstico por imagem , Estudos Transversais , Humanos , Vértebras Lombares , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente
8.
J Magn Reson Imaging ; 50(4): 1219-1226, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30701594

RESUMO

BACKGROUND: There is an interplay between the intervertebral disc (IVD) and the adjacent bone marrow that may play a role in the development of IVD degeneration and might influence chronic lower back pain (CLBP). PURPOSE: To apply novel quantitative MRI techniques to assess the relationship between vertebral bone marrow fat (BMF) and biochemical changes in the adjacent IVD. STUDY TYPE: Prospective. SUBJECTS: Forty-six subjects (26 female and 20 male) with a mean age of 47.3 ± 12.0 years. FIELD STRENGTH/SEQUENCE: 3 T MRI; a combined T1ρ and T2 mapping pulse sequence and a 3D spoiled gradient recalled sequence with six echoes and iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) reconstruction algorithm. ASSESSMENT: Using quantitative MRI, the vertebral BMF fraction was measured as well as the biochemical composition (proteoglycan and collagen content) of the IVD. Furthermore, clinical Pfirrmann grading, Oswestry disability index (ODI), and visual analog scale (VAS) was assessed. STATISTICAL TESTS: Mixed random effects models accounting for multiple measurements per subject were used to assess the relationships between disc measurements and BMF. RESULTS: The relationships between BMF (mean) and T1ρ /T2 (mean and SD) were significant, with P < 0.05. Significant associations (P < 0.001) were found between clinical scores (Pfirrmann, ODI, and VAS) with T1ρ /T2 (mean and SD). BMF mean was significantly related to ODI (P = 0.037) and VAS (P = 0.043), but not with Pfirrmann (P = 0.451). In contrast, BMF SD was significantly related to Pfirrmann (P = 0.000) but not to ODI (P = 0.064) and VAS (P = 0.13). DATA CONCLUSION: Our study demonstrates significant associations between BMF and biochemical changes in the adjacent IVD, both assessed by quantitative MRI; this may suggest that the conversion of hematopoietic bone marrow to fatty bone marrow impairs the supply of available nutrients to cells in the IVD and may thereby accelerate disc degeneration. LEVEL OF EVIDENCE: 2 Technical Efficacy Stage: 3 J. Magn. Reson. Imaging 2019;50:1219-1226.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Degeneração do Disco Intervertebral/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Estudos Transversais , Feminino , Humanos , Disco Intervertebral/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
9.
Magn Reson Med ; 80(2): 726-735, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29194734

RESUMO

PURPOSE: Recent nuclear magnetic resonance and MRI studies have measured a fast-relaxing signal component with T2∗<1 ms in white matter and myelin extracts. In ex vivo studies, evidence suggests that a large fraction of this component directly arises from bound protons in the myelin phospholipid membranes. Based on these results, this ultrashort-T2 component in nervous tissue is a new potential imaging biomarker of myelination, which plays a critical role in neuronal signal conduction across the brain and loss or degradation of myelin is a key feature of many neurological disorders. The goal of this work was to characterize the relaxation times and frequency shifts of ultrashort-T2 components in the human brain. METHODS: This required development of an ultrashort echo time relaxometry acquisition strategy and fitting procedure for robust measurements in the presence of ultrashort T2∗ relaxation times and large frequency shifts. RESULTS: We measured an ultrashort-T2 component in healthy volunteers with a median T2∗ between 0.5-0.7 ms at 3T and 0.2-0.3 ms at 7T as well as an approximately -3 ppm frequency shift from water. CONCLUSION: To our knowledge, this is the first time a chemical shift of the ultrashort-T2 brain component has been measured in vivo. This chemical shift, at around 1.7 ppm, is similar to the primary resonance of most lipids, indicating that much of the ultrashort-T2 component observed in vivo arises from bound protons in the myelin phospholipid membranes. Magn Reson Med 80:726-735, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Humanos , Masculino , Bainha de Mielina/química , Imagens de Fantasmas , Prótons , Adulto Jovem
10.
MAGMA ; 29(3): 359-70, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26702940

RESUMO

OBJECTIVE: Zero echo time (ZTE) and ultrashort echo time (UTE) pulse sequences for MRI offer unique advantages of being able to detect signal from rapidly decaying short-T2 tissue components. In this paper, we applied 3D ZTE and UTE pulse sequences at 7T to assess differences between these methods. MATERIALS AND METHODS: We matched the ZTE and UTE pulse sequences closely in terms of readout trajectories and image contrast. Our ZTE used the water- and fat-suppressed solid-state proton projection imaging method to fill the center of k-space. Images from healthy volunteers obtained at 7T were compared qualitatively, as well as with SNR and CNR measurements for various ultrashort, short, and long-T2 tissues. RESULTS: We measured nearly identical contrast-to-noise and signal-to-noise ratios (CNR/SNR) in similar scan times between the two approaches for ultrashort, short, and long-T2 components in the brain, knee and ankle. In our protocol, we observed gradient fidelity artifacts in UTE, and our chosen flip angle and readout also resulted in shading artifacts in ZTE due to inadvertent spatial selectivity. These can be corrected by advanced reconstruction methods or with different chosen protocol parameters. CONCLUSION: The applied ZTE and UTE pulse sequences achieved similar contrast and SNR efficiency for volumetric imaging of ultrashort-T2 components. Key differences include that ZTE is limited to volumetric imaging, but has substantially reduced acoustic noise levels during the scan. Meanwhile, UTE has higher acoustic noise levels and greater sensitivity to gradient fidelity, but offers more flexibility in image contrast and volume selection.


Assuntos
Imageamento por Ressonância Magnética , Acústica , Algoritmos , Tornozelo/diagnóstico por imagem , Artefatos , Encéfalo/diagnóstico por imagem , Mapeamento Encefálico/métodos , Meios de Contraste/química , Voluntários Saudáveis , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Joelho/diagnóstico por imagem , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/fisiopatologia , Imagens de Fantasmas , Razão Sinal-Ruído
11.
Radiology ; 274(2): 482-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25302832

RESUMO

PURPOSE: To measure the T2* of the human cartilaginous end plate by using magnetic resonance (MR) imaging with very short echo times and to determine the effect of the orientation of the end plate on T2* and on relationships between T2* and biochemical composition. MATERIALS AND METHODS: This study was exempt from institutional review board approval, and informed consent was not required. Thirty-four samples of three cadaveric lumbar spines (from subjects who died at ages 51, 57, and 66 years) containing cartilaginous end plates and subchondral bone were prepared. Samples were imaged with a 3-T imager for T2* quantification by using a three-dimensional very short echo time sequence (repetition time msec/echo times msec, 30/0.075, 2, 5, 12, 18). Samples were imaged with the end plate at three orientations with respect to the constant magnetic induction field: 0°, 54.7°, and 90°. After imaging, the cartilage was assayed for its water, glycosaminoglycan, and collagen content. Pearson correlations were used to investigate the effect of orientation on the relationships between T2* and biochemical composition. RESULTS: T2* was significantly longer when measured at an orientation of 54.7° (21.8 msec ± 2.8 [± standard error of the mean]) than at 0° (10.0 msec ± 0.7, P < .001) or 90° (9.9 msec ± 0.4, P < .001). At 54.7°, T2* was highly correlated with glycosaminoglycan content (r = 0.85, P < .001), the collagen-to-glycosaminoglycan ratio (r = -0.79, P < .001), and water content (r = 0.62, P = .02); at 0° and 90°, there were no significant differences in these relationships, with a minimum P value of .19. CONCLUSION: T2* evaluation can allow noninvasive estimation of the degeneration of the cartilaginous end plate; however, the accuracy of T2*-based estimates of biochemical composition depends on the orientation of the end plate.


Assuntos
Cartilagem Articular/anatomia & histologia , Disco Intervertebral/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Idoso , Água Corporal , Cadáver , Cartilagem Articular/química , Colágeno/análise , Glicosaminoglicanos/análise , Humanos , Disco Intervertebral/química , Masculino , Pessoa de Meia-Idade
12.
Magn Reson Med ; 74(6): 1548-55, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26390357

RESUMO

PURPOSE: To demonstrate the feasibility of using ultrashort echo-time MRI to quantify T1 changes in cortical bone due to heating. METHODS: Variable flip-angle T1 mapping combined with 3D ultrashort echo-time imaging was used to measure T1 in cortical bone. A calibration experiment was performed to detect T1 changes with temperature in ex vivo cortical bone samples from a bovine femur. Ultrasound heating experiments were performed using an interstitial applicator in ex vivo bovine femur specimens, and heat-induced T1 changes were quantified. RESULTS: The calibration experiment demonstrated that T1 increases with temperature in cortical bone. We observed a linear relationship between temperature and T1 with a linear coefficient between 0.67 and 0.84 ms/°C over a range of 25-70°C. The ultrasound heating experiments showed increased T1 changes in the heated regions, and the relationship between the temperature changes and T1 changes was similar to that of the calibration. CONCLUSION: We demonstrated a temperature dependence of T1 in ex vivo cortical bone using a variable flip-angle ultrashort echo-time T1 mapping method.


Assuntos
Temperatura Corporal/fisiologia , Fêmur/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Termografia/métodos , Animais , Temperatura Corporal/efeitos da radiação , Bovinos , Estudos de Viabilidade , Fêmur/efeitos da radiação , Calefação/métodos , Ondas de Choque de Alta Energia , Técnicas In Vitro , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
J Magn Reson Imaging ; 41(5): 1300-10, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24956149

RESUMO

BACKGROUND: To demonstrate the feasibility of using a variable flip angle three-dimensional fast spin-echo (3D VFA-FSE) sequence combined with outer volume suppression for imaging trabecular bone structure at the proximal femur in vivo at 3 Tesla. METHODS: The 3D VFA-FSE acquisition was optimized to minimize blurring and to provide high signal-to-noise ratio (SNR) from bone marrow. Outer volume suppression was achieved by applying three quadratic-phase radio-frequency pulses. The SNR and trabecular bone structures from 3D VFA-FSE were compared with those from previously demonstrated multiple-acquisition 3D balanced steady-state free precision (bSSFP) using theoretical simulations, ex vivo experiments, and in vivo experiments. RESULTS: Our simulation demonstrated that 3D VFA-FSE can provide at least 35% higher SNR than 3D bSSFP, which was confirmed by the ex vivo and in vivo experiments. The ex vivo experiments demonstrated a good correlation and agreement between bone structural paramters obtained with the two sequences. The proposed sequence depicted trabecular bone structure at the proxiaml femur in vivo well without visible suppression artifacts and provided a mean SNR of 11.0. CONCLUSION: The 3D VFA-FSE sequence combined with outer volume suppression can depict the trabecular bone structure of the proximal femur in vivo with minimal blurring and high SNR efficiency.


Assuntos
Fraturas do Colo Femoral/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Técnica de Subtração , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Estudos de Viabilidade , Feminino , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Marcadores de Spin
14.
J Magn Reson Imaging ; 41(5): 1291-9, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24912802

RESUMO

PURPOSE: To assess lesion detection and artifact size reduction of a multiacquisition variable-resonance image combination, slice encoding for metal artifact correction (MAVRIC-SEMAC) hybrid sequence (MAVRIC-SL) compared to standard sequences at 1.5T and 3T in porcine knee specimens with metal hardware. MATERIALS AND METHODS: Artificial cartilage and bone lesions of defined size were created in the proximity of titanium and steel screws with 2.5 mm diameter in 12 porcine knee specimens and were imaged at 1.5T and 3T magnetic resonance imaging (MRI) with MAVRIC-SL PD and short T1 inversion recovery (STIR), standard fast spin echo (FSE) T2 PD, and STIR and fat-saturated T2 FSE sequences. Three radiologists blinded to the lesion locations assessed lesion detection rates on randomized images for each sequence using receiver operating characteristic (ROC). Artifact length and width were measured. RESULTS: Metal artifact sizes were largest in the presence of steel screws at 3T (FSE T2 FS: 28.7 cm(2) ) and 1.5T (16.03 cm(2) ). MAVRIC-SL PD and STIR reduced artifact sizes at both 3T (1.43 cm(2) ; 2.46 cm(2) ) and 1.5T (1.16 cm(2) ; 1.59 cm(2) ) compared to FS T2 FSE sequences (27.57 cm(2) ; 13.20 cm(2) ). At 3T, ROC-derived AUC values using MAVRIC-SL sequences were significantly higher compared to standard sequences (MAVRIC-PD: 0.87, versus FSE-T2 -FS: 0.73 [P = 0.025]; MAVRIC-STIR: 0.9 vs. T2 -STIR: 0.78 [P = 0.001] and vs. FSE-T2 -FS: 0.73 [P = 0.026]). Similar values were observed at 1.5T. Comparison of 3T and 1.5T showed no significant differences (MAVRIC-SL PD: P = 0.382; MAVRIC-SL STIR: P = 0.071). CONCLUSION: MAVRIC-SL sequences provided superior lesion detection and reduced metal artifact size at both 1.5T and 3T compared to conventionally used FSE sequences. No significant disadvantage was found comparing MAVRIC-SL at 3T and 1.5T, although metal artifacts at 3T were larger. J. Magn. Reson. Imaging 2015;41:1291-1299. © 2014 Wiley Periodicals, Inc.


Assuntos
Artefatos , Parafusos Ósseos , Articulação do Joelho/anatomia & histologia , Prótese do Joelho , Imageamento por Ressonância Magnética/métodos , Próteses Articulares Metal-Metal , Animais , Interpretação de Imagem Assistida por Computador/métodos , Articulação do Joelho/cirurgia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin , Aço Inoxidável , Suínos , Titânio
15.
J Magn Reson Imaging ; 42(2): 539-44, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25425074

RESUMO

BACKGROUND: To validate six-echo, chemical-shift based MRI with T2 * correction for the quantification of bone marrow fat content in the presence of trabecular bone. METHODS: Ten bone phantoms were made using trabecular bone cores extracted from the distal femur and proximal tibia of 20 human cadaveric knees. Bone marrow was removed from the cores and the marrow spaces were filled with water-fat gelatin to mimic bone marrow of known fat fractions. A chemical-shift based water-fat separation method with T2 * correction was used to generate fat fraction maps. The proton density fat fractions (PDFF) between marrow regions with and without bone were compared with the reference standard of known fat fraction using the squared Pearson correlation coefficient and unpaired t-test. RESULTS: Strong correlations were found between the known fat fraction and measured PDFF in marrow without trabecular bone (R(2) = 0.99; slope = 0.99, intercept = 0.94) as well as in marrow with trabecular bone (R(2) = 0.97; slope = 1.0, intercept = -3.58). Measured PDFF between regions with and without bone were not significantly different (P = 0.5). However, PDFF was systematically underestimated by -3.2% fat fraction in regions containing trabecular bone. CONCLUSION: Our implementation of a six-echo chemical-shift based MRI pulse sequence with T2 * correction provided an accurate means of determining fat content in bone marrow in the presence of trabecular bone.


Assuntos
Tecido Adiposo/fisiologia , Adiposidade/fisiologia , Medula Óssea/fisiologia , Fêmur/fisiologia , Imageamento por Ressonância Magnética/métodos , Tíbia/fisiologia , Tecido Adiposo/anatomia & histologia , Medula Óssea/anatomia & histologia , Cadáver , Fêmur/anatomia & histologia , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/instrumentação , Tamanho do Órgão , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tíbia/anatomia & histologia
16.
Eur Radiol ; 25(8): 2403-11, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25680728

RESUMO

OBJECTIVE: The aim of our study was to evaluate the clinical feasibility and diagnostic value of a new MRI metal artefact reduction pulse sequence called MAVRIC-SL in a 3 T MRI environment. SUBJECTS AND METHODS: Two MAVRIC-SL sequences obtained in 61 patients with symptomatic total hip replacement were compared with standard FSE-STIR sequences optimized for imaging around metal. Artefact size was measured on the slice of greatest extent. Image quality, fat saturation, image distortion, visibility of anatomical structures, and detectability of joint abnormalities were visually assessed and graded on qualitative scales. Differences between MAVRIC-SL and FSE sequences were tested with the Wilcoxon signed-rank test. RESULTS: MAVRIC-SL sequences at 3 T showed significantly smaller metal artefacts compared to FSE-STIR sequences (p < 0.0001). The general image quality of MAVRIC-SL sequences was reduced with regard to spatial resolution, noise and contrast (p = 0.001), and fat saturation (p < 0.0001). The reduction of artefact size and image distortion significantly improved visualization of joint anatomy (p < 0.0001) and diagnostic confidence regarding implant-associated abnormalities (p = 0.0075 to <0.0001). CONCLUSION: Although the image quality of MAVRIC-SL sequences is limited at 3 T, its clinical application is feasible and provides important additional diagnostic information for the workup of patients with symptomatic hip replacement through substantially reduced metal artefacts. KEY POINTS: • Metal artefacts compromise imaging of total hip replacement with MRI. • Metal artefacts are aggravated with 3 Tesla MRI. • MAVRIC-SL is a technique to suppress metal artefacts. • MAVRIC-SL effectively reduces metal artefacts at 3 Tesla and improves diagnostic quality.


Assuntos
Artroplastia de Quadril , Artefatos , Prótese de Quadril , Metais , Osteólise/patologia , Adulto , Idoso , Estudos Transversais , Estudos de Viabilidade , Feminino , Articulação do Quadril/patologia , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
17.
Skeletal Radiol ; 44(11): 1609-16, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26201676

RESUMO

PURPOSE: This work aimed to compare the diagnostic performance of a metal artifact suppression sequence (MAVRIC-SL) for imaging of hip arthroplasties (HA) at 1.5 and 3 Tesla (T) field strength. METHODS: Eighteen patients (10 females; aged 27-74) with HA were examined at 3.0 and 1.5 T within 3 weeks. The sequence protocol included 3D-MAVRIC-SL PD (coronal), 3D-MAVRIC-SL STIR (axial), FSE T1, FSE PD and STIR sequences. Anatomical structures and pathological findings were assessed independently by two radiologists. Artifact extent and technical quality (image quality, fat saturation and geometric distortion) were also evaluated. Findings at 1.5 and 3.0 T were compared using a Wilcoxon signed rank test. RESULTS: While image quality was better at 1.5 T, visualization of anatomic structures and clinical abnormalities was not significantly different using the two field strengths (p > 0.05). Fat suppression and amount of artifacts were significantly better at 1.5 T (p < 0.01). Inter- and intra-reader agreement for different anatomic details, image quality and visualization of abnormalities ranged from k = 0.62 to k = 1.00. CONCLUSION: MAVRIC-SL at 1.5 T had a comparable diagnostic performance when compared MAVRIC-SL at 3.0 T; however, the higher field strength was associated with larger artifacts, limited image quality and worse fat saturation.


Assuntos
Artroplastia de Substituição , Artefatos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Metais , Complicações Pós-Operatórias/patologia , Adulto , Idoso , Feminino , Articulação do Quadril/patologia , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes
18.
Magn Reson Med ; 71(4): 1511-7, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23821305

RESUMO

PURPOSE: To demonstrate the capability of incorporating independent shims into a dual-band spectral-spatial excitation and to compare fat suppression between standard global shims and independent shims for in vivo bilateral breast imaging at 1.5T. METHODS: A dual-band spectral-spatial excitation pulse was designed by interleaving two flyback spectral-spatial pulses, playing one during positive gradient lobes and the other during negative gradient lobes. Each slab was enabled to have an independent spatial offset, spectral offset, and slab-phase modulation by modulating radiofrequency phase, and independent linear shims were incorporated by playing extra shim gradients. Phantom experiments were performed to demonstrate the functionality of the pulse, and in vivo experiments were performed for 10 healthy volunteers to compare fat suppression between standard shims and independent shims. RESULTS: The phantom experiments confirmed that the dual-band pulse can provide independent spectral and spatial offsets and linear shims to the two slabs. Independent shims provided qualitatively more homogeneous fat suppression than standard shims in seven out of 10 subjects, with equivalent fat suppression in two of the other three subjects. CONCLUSION: Incorporating independent shims into the dual-band spectral-spatial excitation can provide homogeneous fat suppression in bilateral breast imaging.


Assuntos
Tecido Adiposo/anatomia & histologia , Algoritmos , Artefatos , Mama/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Feminino , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração
20.
Int J Hyperthermia ; 29(7): 629-42, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24102393

RESUMO

PURPOSE: The objectives of this study were to develop numerical models of interstitial ultrasound ablation of tumours within or adjacent to bone, to evaluate model performance through theoretical analysis, and to validate the models and approximations used through comparison to experiments. METHODS: 3D transient biothermal and acoustic finite element models were developed, employing four approximations of 7-MHz ultrasound propagation at bone/soft tissue interfaces. The various approximations considered or excluded reflection, refraction, angle-dependence of transmission coefficients, shear mode conversion, and volumetric heat deposition. Simulations were performed for parametric and comparative studies. Experiments within ex vivo tissues and phantoms were performed to validate the models by comparison to simulations. Temperature measurements were conducted using needle thermocouples or magnetic resonance temperature imaging (MRTI). Finite element models representing heterogeneous tissue geometries were created based on segmented MR images. RESULTS: High ultrasound absorption at bone/soft tissue interfaces increased the volumes of target tissue that could be ablated. Models using simplified approximations produced temperature profiles closely matching both more comprehensive models and experimental results, with good agreement between 3D calculations and MRTI. The correlation coefficients between simulated and measured temperature profiles in phantoms ranged from 0.852 to 0.967 (p-value < 0.01) for the four models. CONCLUSIONS: Models using approximations of interstitial ultrasound energy deposition around bone/soft tissue interfaces produced temperature distributions in close agreement with comprehensive simulations and experimental measurements. These models may be applied to accurately predict temperatures produced by interstitial ultrasound ablation of tumours near and within bone, with applications toward treatment planning.


Assuntos
Modelos Teóricos , Neoplasias/terapia , Terapia por Ultrassom , Acústica , Animais , Temperatura Corporal , Osso e Ossos , Bovinos , Análise de Elementos Finitos , Músculos , Suínos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa