Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Pediatr Res ; 95(1): 93-101, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37087539

RESUMO

BACKGROUND: Clinical translation of the extracorporeal artificial placenta (AP) is impeded by the high risk for intracranial hemorrhage in extremely premature newborns. The Nitric Oxide Surface Anticoagulation (NOSA) system is a novel non-thrombogenic extracorporeal circuit. This study aims to test the NOSA system in the AP without systemic anticoagulation. METHODS: Ten extremely premature lambs were delivered and connected to the AP. For the NOSA group, the circuit was coated with DBHD-N2O2/argatroban, 100 ppm nitric oxide was blended into the sweep gas, and no systemic anticoagulation was given. For the Heparin control group, a non-coated circuit was used and systemic anticoagulation was administered. RESULTS: Animals survived 6.8 ± 0.6 days with normal hemodynamics and gas exchange. Neither group had any hemorrhagic or thrombotic complications. ACT (194 ± 53 vs. 261 ± 86 s; p < 0.001) and aPTT (39 ± 7 vs. 69 ± 23 s; p < 0.001) were significantly lower in the NOSA group than the Heparin group. Platelet and leukocyte activation did not differ significantly from baseline in the NOSA group. Methemoglobin was 3.2 ± 1.1% in the NOSA group compared to 1.6 ± 0.6% in the Heparin group (p < 0.001). CONCLUSIONS: The AP with the NOSA system successfully supported extremely premature lambs for 7 days without significant bleeding or thrombosis. IMPACT: The Nitric Oxide Surface Anticoagulation (NOSA) system provides effective circuit-based anticoagulation in a fetal sheep model of the extracorporeal artificial placenta (AP) for 7 days. The NOSA system is the first non-thrombogenic circuit to consistently obviate the need for systemic anticoagulation in an extracorporeal circuit for up to 7 days. The NOSA system may allow the AP to be implemented clinically without systemic anticoagulation, thus greatly reducing the intracranial hemorrhage risk for extremely low gestational age newborns. The NOSA system could potentially be applied to any form of extracorporeal life support to reduce or avoid systemic anticoagulation.


Assuntos
Oxigenação por Membrana Extracorpórea , Nascimento Prematuro , Trombose , Gravidez , Humanos , Feminino , Ovinos , Animais , Óxido Nítrico , Placenta/fisiologia , Heparina , Hemorragia/complicações , Trombose/prevenção & controle , Anticoagulantes/farmacologia , Hemorragias Intracranianas/complicações
2.
Anal Chem ; 92(20): 13641-13646, 2020 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-32955253

RESUMO

In this letter, the innate ability of nitric oxide (NO) to inhibit platelet activation/adhesion/thrombus formation is employed to improve the hemocompatibility and in vivo accuracy of an intravascular (IV) potentiometric PCO2 (partial pressure of carbon dioxide) sensor. The catheter-type sensor is fabricated by impregnating a segment of dual lumen silicone tubing with a proton ionophore, plasticizer, and lipophilic cation-exchanger. Subsequent filling of bicarbonate and strong buffer solutions and placement of Ag/AgCl reference electrode wires within each lumen, respectively, enables measurement of the membrane potential difference across the inner wall of the tube, with this potential changing as a function of the logarithm of sample PCO2. The dual lumen device is further encapsulated within a S-nitroso-N-acetyl-DL-penicillamine (SNAP)-doped silicone tube that releases physiological levels of NO. The NO releasing sensor exhibits near-Nernstian sensitivity toward PCO2 (slope = 59.31 ± 0.78 mV/decade) and low drift rates (<2 mV/24 h after initial equilibration). In vivo evaluation of the NO releasing sensors, performed in the arteries and veins of anesthetized pigs for 20 h, shows enhanced accuracy (vs non-NO releasing sensors) when benchmarked to measurements of discrete blood samples made with a commercial blood gas analyzer. The accurate, continuous monitoring of blood PCO2 levels achieved with this new IV NO releasing PCO2 sensor configuration could help better manage hospitalized patients in critical care units.


Assuntos
Materiais Biocompatíveis/química , Dióxido de Carbono/análise , Óxido Nítrico/metabolismo , Potenciometria/métodos , Animais , Vasos Sanguíneos/química , Eletrodos , Resinas de Troca Iônica/química , Potenciometria/instrumentação , S-Nitroso-N-Acetilpenicilamina/química , Silicones/química , Suínos
3.
ASAIO J ; 68(7): 949-955, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35383597

RESUMO

The artificial placenta (AP) promotes organ development and reduces organ injury in a lamb model of extreme prematurity. This study evaluates hepatic outcomes after AP support with total parenteral nutrition (TPN) administration. Premature lambs (116-121 days estimated gestational age; term = 145) were cannulated for 7 days of AP support. Lambs received TPN with SMOFlipid (n = 7) or Intralipid (n = 5). Liver function and injury were compared between the two groups biochemically and histologically. Groups were compared by ANOVA with Tukey's multiple comparisons or linear-mixed effects models. From baseline to day 7, total bilirubin (Intralipid 2.6 ± 2.3 to 7.9 ± 4.4 mg/dl; SMOFlipid 0.3 ± 0.1 to 5.5 ± 2.3 mg/dl), alanine aminotransferase, and gamma-glutamyl transferase increased in both groups ( p < 0.001 for all). Direct bilirubin (0.3 ± 0.2 to 1.8 ± 1.4 mg/dl; p = 0.006) and AST (27 ± 5 to 309 ± 242 mg/dl; p < 0.001) increased in SMOFlipid group (not measured in Intralipid group). On liver histology, Intralipid showed more cholestasis than SMOFlipid; both groups showed more than tissue controls. The Intralipid group alone showed hepatocyte injury and had more congestion than controls. Lambs supported by the AP with TPN administration maintain normal hepatic function and sustain minimal hepatic injury. SMOFlipid is associated with decreased cholestasis and hepatic injury versus Intralipid.


Assuntos
Colestase , Nutrição Parenteral Total , Animais , Bilirrubina , Feminino , Nutrição Parenteral Total/efeitos adversos , Placenta , Gravidez , Ovinos , Carneiro Doméstico
4.
J Pediatr Surg ; 57(1): 26-33, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34649727

RESUMO

BACKGROUND: Artificial lungs have the potential to serve as a bridge to transplantation or recovery for children with end-stage lung disease dependent on extracorporeal life support, but such devices currently require systemic anticoagulation. We describe our experience using the novel Nitric Oxide (NO) Surface Anticoagulation (NOSA) system-an NO-releasing circuit with NO in the sweep gas-with the Pediatric MLung-a low-resistance, pumpless artificial lung. METHODS: NO flux testing: MLungs (n = 4) were tested using veno-venous extracorporeal life support in a sheep under anesthesia with blood flow set to 0.5 and 1 L/min and sweep gas blended with 100 ppm NO at 1, 2, and 4 L/min. NO and NO2 were measured in the sweep and exhaust gas to calculate NO flux across the MLung membrane. Pumpless implants: Sheep (20-100 kg, n = 3) underwent thoracotomy and cannulation via the pulmonary artery (device inflow) and left atrium (device outflow) using cannulae and circuit components coated with an NO donor (diazeniumdiolated dibutylhexanediamine; DBHD-N2O2) and argatroban. Animals were connected to the MLung with 100 ppm NO in the sweep gas under anesthesia for 24 h with no systemic anticoagulation after cannulation. RESULTS: NO flux testing: NO flux averaged 3.4 ± 1.0 flux units (x10-10 mol/cm2/min) (human vascular endothelium: 0.5-4 flux units). Pumpless implants: 3 sheep survived 24 h with patent circuits. MLung blood flow was 716 ± 227 mL/min. Outlet oxygen saturation was 98.3 ± 2.6%. Activated clotting time was 151±24 s. Platelet count declined from 334,333 ± 112,225 to 123,667 ± 7,637 over 24 h. Plasma free hemoglobin and leukocyte and platelet activation did not significantly change. CONCLUSIONS: The NOSA system provides NO flux across a gas-exchange membrane of a pumpless artificial lung at a similar rate as native vascular endothelium and achieves effective local anticoagulation of an artificial lung circuit for 24 h.


Assuntos
Oxigenação por Membrana Extracorpórea , Óxido Nítrico , Animais , Anticoagulantes , Criança , Humanos , Pulmão , Saturação de Oxigênio , Ovinos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa