Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Base de dados
País como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 29(Pt 4): 1074-1084, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35787575

RESUMO

In this work, a new image guidance system and protocols for delivering image-guided radiotherapy (IGRT) on the Imaging and Medical Beamline (IMBL) at the ANSTO Australian Synchrotron are introduced. The image guidance methods used and the resulting accuracy of tumour alignment in in vivo experiments are often under-reported. Image guidance tasks are often complex, time-consuming and prone to errors. If unchecked, they may result in potential mis-treatments. We introduce SyncMRT, a software package that provides a simple, image guidance tool-kit for aligning samples to the synchrotron beam. We have demonstrated sub-millimetre alignment using SyncMRT and the small-animal irradiation platform (the DynamicMRT system) on the IMBL. SyncMRT has become the standard for carrying out IGRT treatments on the IMBL and has been used in all pre-clinical radiotherapy experiments since 2017. Further, we introduce two quality assurance (QA) protocols to synchrotron radiotherapy on the IMBL: the Winston-Lutz test and hidden target test. It is shown that the presented QA tests are appropriate for picking up geometrical setup errors and assessing the end-to-end accuracy of the image guidance process. Together, these tools make image guidance easier and provide a mechanism for reporting the geometric accuracy of synchrotron-based IGRT treatments. Importantly, this work is scalable to other delivery systems, and is in continual development to support the upcoming veterinary radiotherapy trials on the IMBL.


Assuntos
Radioterapia Guiada por Imagem , Animais , Austrália , Radioterapia Guiada por Imagem/métodos , Síncrotrons
2.
J Synchrotron Radiat ; 28(Pt 6): 1769-1777, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34738930

RESUMO

Laminitis is an extremely painful and debilitating condition of horses that can affect their athletic ability and even quality of life. The current gold standard for assessment of laminar tissue is histology, which is the only modality that enables detailed visualization of the lamina. Histology requires dissection of the hoof and therefore can only represent one specific time point. The superior spatial and contrast resolution of synchrotron computed tomography (sCT), when compared with readily available imaging modalities, such as radiographs and conventional CT, provides an opportunity for detailed studies of the lamina without the need for hoof dissection and histological assessment. If the resolution of histology can be matched or even approached, dynamic events, such as laminar blood flow, could also be studied on the microscopic tissue level. To investigate this possible application of sCT further, two objectives are presented: (i) to develop a protocol for sCT of an equine digit using cadaver limbs and (ii) to apply the imaging protocol established during (i) for sCT imaging of the vasculature within the foot using an ex vivo perfusion system to deliver the vascular contrast. The hypotheses were that sCT would allow sufficient resolution for detailed visualization to the level of the secondary lamellae and associated capillaries within the equine digit. Synchrotron CT enabled good visualization of the primary lamellae (average length 3.6 mm) and the ex vivo perfusion system was able to deliver vascular contrast agent to the vessels of the lamina. The individual secondary lamellae (average length 0.142 mm) could not be seen in detail, although differentiation between primary and secondary lamellae was achieved. This approaches, but does not yet reach, the current gold standard, histology, for assessment of the lamellae; however, with further refinement of this imaging technique, improved resolution may be accomplished in future studies.


Assuntos
Casco e Garras , Síncrotrons , Animais , Austrália , Casco e Garras/diagnóstico por imagem , Cavalos , Qualidade de Vida , Tomografia Computadorizada por Raios X
3.
IEEE Trans Med Imaging ; 41(11): 2980-2990, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35584078

RESUMO

Breast microcalcifications are an important primary radiological indicator of breast cancer. However, microcalcification classification and diagnosis may be still challenging for radiologists due to limitations of the standard 2D mammography technique, including spatial and contrast resolution. In this study, we propose an approach to improve the detection of microcalcifications in propagation-based phase-contrast X-ray computed tomography of breast tissues. Five fresh mastectomies containing microcalcifications were scanned at different X-ray energies and radiation doses using synchrotron radiation. Both bright-field (i.e. conventional phase-retrieved images) and dark-field images were extracted from the same data sets using different image processing methods. A quantitative analysis was performed in terms of visibility and contrast-to-noise ratio of microcalcifications. The results show that while the signal-to-noise and the contrast-to-noise ratios are lower, the visibility of the microcalcifications is more than two times higher in the dark-field images compared to the bright-field images. Dark-field images have also provided more accurate information about the size and shape of the microcalcifications.


Assuntos
Doenças Mamárias , Neoplasias da Mama , Calcinose , Humanos , Feminino , Mamografia/métodos , Calcinose/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem
4.
Phys Med ; 77: 64-74, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32791426

RESUMO

Experimental measurement of Synchrotron Radiotherapy (SyncRT) doses is challenging, especially for Microbeam Radiotherapy (MRT), which is characterised by very high dynamic ranges with spatial resolutions on the micrometer scale. Monte Carlo (MC) simulation is considered a gold standard for accurate dose calculation in radiotherapy, and is therefore routinely relied upon to produce verification data. We present a MC model for Australian Synchrotron's Imaging and Medical Beamline (IMBL), which is capable of generating accurate dosimetry data to inform and/or verify SyncRT experiments. Our MC model showed excellent agreement with dosimetric measurement for Synchrotron Broadbeam Radiotherapy (SBBR). Our MC model is also the first to achieve validation for MRT, using two methods of dosimetry, to within clinical tolerances of 5% for a 20×20 mm2 field size, except for surface measurements at 5 mm depth, which remained to within good agreement of 7.5%. Our experimental methodology has allowed us to control measurement uncertainties for MRT doses to within 5-6%, which has also not been previously achieved, and provides a confidence which until now has been lacking in MRT validation studies. The MC model is suitable for SyncRT dose calculation of clinically relevant field sizes at the IMBL, and can be extended to include medical beamlines at other Synchrotron facilities as well. The presented MC model will be used as a validation tool for treatment planning dose calculation algorithms, and is an important step towards veterinary SyncRT trials at the Australian Synchrotron.


Assuntos
Radiometria , Síncrotrons , Austrália , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
5.
Science ; 292(5518): 914-6, 2001 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-11340201

RESUMO

We report phonon densities of states (DOS) of iron measured by nuclear resonant inelastic x-ray scattering to 153 gigapascals and calculated from ab initio theory. Qualitatively, they are in agreement, but the theory predicts density at higher energies. From the DOS, we derive elastic and thermodynamic parameters of iron, including shear modulus, compressional and shear velocities, heat capacity, entropy, kinetic energy, zero-point energy, and Debye temperature. In comparison to the compressional and shear velocities from the preliminary reference Earth model (PREM) seismic model, our results suggest that Earth's inner core has a mean atomic number equal to or higher than pure iron, which is consistent with an iron-nickel alloy.

6.
Med Phys ; 46(12): 5478-5487, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31574166

RESUMO

PURPOSE: Propagation-based phase-contrast computed tomography (PB-CT) is a method for three-dimensional x-ray imaging that utilizes refraction, as well as absorption, of x rays in the tissues to increase the signal-to-noise ratio (SNR) in the resultant images, in comparison with equivalent conventional absorption-only x-ray tomography (CT). Importantly, the higher SNR is achieved without sacrificing spatial resolution or increasing the radiation dose delivered to the imaged tissues. The present work has been carried out in the context of the current development of a breast CT imaging facility at the Australian Synchrotron. METHODS: Seven unfixed complete mastectomy samples with and without breast cancer lesions have been imaged using absorption-only CT and PB-CT techniques under controlled experimental conditions. The radiation doses delivered to the mastectomy samples during the scans were comparable to those approved for mammographic screening. Physical characteristics of the reconstructed images, such as spatial resolution and SNR, have been measured and compared with the results of the radiological quality assessment of the complete absorption CT and PB-CT image stacks. RESULTS: Despite the presence of some image artefacts, the PB-CT images have outperformed comparable absorption CT images collected at the same radiation dose, in terms of both the measured objective image characteristics and the radiological image scores. The outcomes of these experiments are shown to be consistent with predictions of the theory of PB-CT imaging and previous reported experimental studies of this imaging modality. CONCLUSIONS: The results presented in this paper demonstrate that PB-CT holds a high potential for improving on the quality and diagnostic value of images obtained using existing medical x-ray technologies, such as mammography and digital breast tomosynthesis (DBT). If implemented at suitable synchrotron imaging facilities, PB-CT can be used to complement existing imaging modalities, leading to more accurate breast cancer diagnosis.


Assuntos
Mastectomia , Síncrotrons , Tomografia Computadorizada por Raios X/instrumentação , Mama/diagnóstico por imagem , Mama/cirurgia , Feminino , Humanos , Processamento de Imagem Assistida por Computador
9.
Phys Rev B Condens Matter ; 53(6): R2907-R2909, 1996 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-9983881
10.
Phys Rev Lett ; 94(11): 115502, 2005 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-15903870

RESUMO

We present evidence for an isostructural, first-order Mott transition in MnO at 105+/-5 GPa, based on high-resolution x-ray emission spectroscopy and angle-resolved x-ray diffraction data. The pressure-induced structural and spectral changes provide a coherent picture of MnO phase transitions from paramagnetic B1 to antiferromagnetic distorted B1 at 30 GPa, to paramagnetic B8 at 90 GPa, and to diamagnetic B8 at 105+/-5 GPa. The last is the Mott transition, accompanied by a significant loss of magnetic moment, an approximately 6.6% volume collapse and the insulator-metal transition as demonstrated by recent resistance measurements.

11.
J Synchrotron Radiat ; 5(Pt 3): 1023-5, 1998 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-15263732

RESUMO

A new method for density measurements by means of X-ray absorption under high pressure and high temperature using synchrotron radiation has been developed. The method has been modified for a large-volume Paris-Edinburgh press and combined with intense high-energy X-rays at the ESRF. In order to overcome effects of deformation of sample shape under pressure, a ruby cylinder was used as a sample container. The density was determined from the intensity profile of transmitted X-rays. The densities of crystalline and liquid Bi were successfully measured up to 750 K at 1 GPa.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa