1.
IEEE Trans Med Imaging ; 40(11): 3077-3088, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34029189

RESUMO

To avoid severe limited-view artifacts in reconstructed CT images, current multi-row detector CT (MDCT) scanners with a single x-ray source-detector assembly need to limit table translation speeds such that the pitch p (viz., normalized table translation distance per gantry rotation) is lower than 1.5. When , it remains an open question whether one can reconstruct clinically useful helical CT images without severe artifacts. In this work, we show that a synergistic use of advanced techniques in conventional helical filtered backprojection, compressed sensing, and more recent deep learning methods can be properly integrated to enable accurate reconstruction up to p=4 without significant artifacts for single source MDCT scans.


Assuntos
Tomografia Computadorizada Espiral , Tomografia Computadorizada por Raios X , Artefatos , Imagens de Fantasmas
2.
Med Phys ; 45(10): 4519-4528, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30102414

RESUMO

PURPOSE: The CT number accuracy, that is, CT number bias, plays an important role in clinical diagnosis. When strategies to reduce radiation dose are discussed, it is important to make sure that the CT number bias is controlled within an acceptable range. The purpose of this paper was to investigate the dependence of CT number bias on radiation dose level and on image contrast (i.e., the difference in CT number between the ROI and the background) in Computed Tomography (CT). METHODS: A lesion-background model was introduced to theoretically study how the CT number bias changes with radiation exposure level and with CT number contrast when a simple linear reconstruction algorithm such as filtered backprojection (FBP) is used. The theoretical results were validated with experimental studies using a benchtop CT system equipped with a photon-counting detector (XC-HYDRA FX50, XCounter AB, Sweden) and a clinical diagnostic MDCT scanner (Discovery CT750 HD, GE Healthcare, Waukesha, WI, USA) equipped with an energy-integrating detector. The Catphan phantom (Catphan 600, the Phantom Laboratory, Salem, NY, USA) was scanned at different mAs levels and 50 scans were performed for each mAs. The bias of CT number was evaluated for each combination of mAs and ROIs with different contrast levels. An anthropomorphic phantom (ATOM 10-year-old phantom, Model 706, CIRS Inc. Norfolk, VA, USA) with much more heterogeneous object content was used to test the applicability of the theory to the more general image object cases. RESULTS: Both theoretical and experimental studies showed that the CT number bias is inversely proportional to the radiation exposure level yet linearly dependent on the CT number contrast between the lesion and the background, that is, Bias ( µ ^ 1 FBP ) = α mAs ( 1 + ß Δ H U ) . CONCLUSIONS: The quantitative accuracy of CT numbers can be problematic and thus needs some extra attention when radiation dose is reduced. In this work, we showed that the bias of the FBP reconstruction increases as mAs is reduced; both positive and negative bias can be observed depending on the contrast difference between a targeted ROI and its surrounding background tissues.


Assuntos
Modelos Teóricos , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Fótons , Tomografia Computadorizada por Raios X/instrumentação
3.
Med Phys ; 45(5): 1957-1969, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29532480

RESUMO

PURPOSE: Different low-signal correction (LSC) methods have been shown to efficiently reduce noise streaks and noise level in CT to provide acceptable images at low-radiation dose levels. These methods usually result in CT images with highly shift-variant and anisotropic spatial resolution and noise, which makes the parameter optimization process highly nontrivial. The purpose of this work was to develop a local task-based parameter optimization framework for LSC methods. METHODS: Two well-known LSC methods, the adaptive trimmed mean (ATM) filter and the anisotropic diffusion (AD) filter, were used as examples to demonstrate how to use the task-based framework to optimize filter parameter selection. Two parameters, denoted by the set P, for each LSC method were included in the optimization problem. For the ATM filter, these parameters are the low- and high-signal threshold levels pl and ph ; for the AD filter, the parameters are the exponents δ and γ in the brightness gradient function. The detectability index d' under the non-prewhitening (NPW) mathematical observer model was selected as the metric for parameter optimization. The optimization problem was formulated as an unconstrained optimization problem that consisted of maximizing an objective function d'(P), where i and j correspond to the i-th imaging task and j-th spatial location, respectively. Since there is no explicit mathematical function to describe the dependence of d' on the set of parameters P for each LSC method, the optimization problem was solved via an experimentally measured d' map over a densely sampled parameter space. In this work, three high-contrast-high-frequency discrimination imaging tasks were defined to explore the parameter space of each of the LSC methods: a vertical bar pattern (task I), a horizontal bar pattern (task II), and a multidirectional feature (task III). Two spatial locations were considered for the analysis, a posterior region-of-interest (ROI) located within the noise streaks region and an anterior ROI, located further from the noise streaks region. Optimal results derived from the task-based detectability index metric were compared to other operating points in the parameter space with different noise and spatial resolution trade-offs. RESULTS: The optimal operating points determined through the d' metric depended on the interplay between the major spatial frequency components of each imaging task and the highly shift-variant and anisotropic noise and spatial resolution properties associated with each operating point in the LSC parameter space. This interplay influenced imaging performance the most when the major spatial frequency component of a given imaging task coincided with the direction of spatial resolution loss or with the dominant noise spatial frequency component; this was the case of imaging task II. The performance of imaging tasks I and III was influenced by this interplay in a smaller scale than imaging task II, since the major frequency component of task I was perpendicular to imaging task II, and because imaging task III did not have strong directional dependence. For both LSC methods, there was a strong dependence of the overall d' magnitude and shape of the contours on the spatial location within the phantom, particularly for imaging tasks II and III. The d' value obtained at the optimal operating point for each spatial location and imaging task was similar when comparing the LSC methods studied in this work. CONCLUSIONS: A local task-based detectability framework to optimize the selection of parameters for LSC methods was developed. The framework takes into account the potential shift-variant and anisotropic spatial resolution and noise properties to maximize the imaging performance of the CT system. Optimal parameters for a given LSC method depend strongly on the spatial location within the image object.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Imagens de Fantasmas , Razão Sinal-Ruído
4.
Med Phys ; 45(5): 1942-1956, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29532483

RESUMO

PURPOSE: Low-signal correction (LSC) in the raw counts domain has been shown to effectively reduce noise streaks in CT because the data inconsistency associated with photon-starved regions may be mitigated prior to the log transformation step. However, a systematic study of the performance of these raw data correction methods is still missing in literature. The purpose of this work was to provide such a systematic study for two well-known low-signal correction schemes using either the adaptive trimmed mean (ATM) filter or the anisotropic diffusion (AD) filter in the raw counts domain. METHODS: Image data were acquired experimentally using an anthropomorphic chest phantom and a benchtop cone-beam CT (CBCT) imaging system. Phantom scans were repeated 50 times at a reduced dose level of 0.5 mGy and a reference level of 1.9 mGy. The measured raw counts at 0.5 mGy underwent LSC using the ATM and AD filters. Two relevant parameters were identified for each filter and approximately one hundred operating points in each parameter space were analyzed. Following LSC and log transformation, FDK reconstruction was performed for each case. Noise and spatial resolution properties were assessed across the parameter spaces that define each LSC filter; the results were summarized through 2D contour maps to better understand the trade-offs between these competing image quality features. 2D noise power spectrum (NPS) and modulation transfer function (MTF) were measured locally at two spatial locations in the field-of-view (FOV): a posterior region contaminated by noise streaks and an anterior region away from noise streaks. An isotropy score metric was introduced to characterize the directional dependence of the NPS and MTF (viz., ϵNPS and ϵMTF , respectively), with a range from 0 for highly anisotropic to 1 for perfectly isotropic. The noise magnitude and coarseness were also measured. RESULTS: (a) Both the ATM and AD LSC methods were successful in reducing noise streaks, but their noise and spatial resolution properties were found to be highly anisotropic and shift-variant. (b) NPS isotropy scores in the posterior region were generally improved from ϵNPS = 0.09 for the images without LSC to the range ϵNPS = (0.11, 0.67) for ATM and ϵNPS = (0.06, 0.67) for AD, depending on the filter parameters used. (c) The noise magnitude was reduced across the parameter space of either LSC filter whenever a change along the axis of the controlling parameter led to stronger raw data filtration. Changes in noise magnitude were inversely related to changes in spatial resolution along the direction perpendicular to the streaks. No correlation was found, however, between the contour maps of noise magnitude and the NPS isotropy. (d) Both filters influenced the noise coarseness anisotropically, with coarser noise occurring along directions perpendicular to the noise streaks. The anisotropic noise coarseness was intrinsically and directly related to resolution losses in a given direction: coarseness plots mimic the topography of the 2D MTF, i.e., the coarser the noise, the lower the resolution. CONCLUSIONS: Both AD and ATM LSC schemes enable low-dose CBCT imaging. However, it was found that noise magnitude and overall spatial resolution vary considerably across the parameter space for each filter, and more importantly these image quality features are highly anisotropic and shift-variant.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Razão Sinal-Ruído , Imagens de Fantasmas , Reprodutibilidade dos Testes