RESUMO
This study evaluated the effects of Al-coagulant sludge characteristics on the efficiency ofcoagulant recovery by acidification with H2SO4. Two sludge characteristics were studied: types of coagulant and textures of the suspended solid in raw water. The coagulant types are aluminium sulphate and polyaluminium chloride (PACl); the textures of the suspended solid are sand-based and clay-based. Efficiency of aluminium recovery at a pH of 2 was compared for different sludges obtained from water treatment plants in Taiwan. The results showed that efficiency of aluminium recovery from sludge containing clayey particles was higher than that from sludge containing sandy particles. As for the effect of coagulant types, the aluminium recovery efficiency for sludge using PACl ranged between 77% and 100%, whereas it ranged between 65% and 72% for sludge using aluminium sulphate as the coagulant. This means using PACl as the coagulant could result in higher recovery efficiency of coagulant and be beneficial for water treatment plants where renewable materials and waste reduction as the factors for making decisions regarding plant operations. However, other metals, such as manganese, could be released with aluminium during the acidification process and limit the use of the recovered coagulants. It is suggested that the recovered coagulants be used in wastewater treatment processes.
Assuntos
Ácidos/química , Alumínio/química , Esgotos , Sedimentos Geológicos/química , Metais Pesados/químicaRESUMO
Bisphenol A (BPA) is a renowned plasticizer, and a key component of various plastics, resins, and food packaging materials. However, BPA have been identified as an endocrine disruption compound and cause severe consequences such as infertility, diabetic, obesity, carcinoma, and possess high risk of exposure in aquatic ecosystem. To this, we crafted an ultrasensitive electrochemical sensor based on the manganese sulfide nanoparticles (MnS NPs) catalyzed electrochemical oxidation of BPA, and its eventual application in rapid screening of BPA contamination. The physiochemical characteristics and electrocatalytic performance of the MnS nanocatalyst have been well studied and utilized in the fabrication of MnS/GCE based BPA sensor. The fabricated BPA sensor has shown a broad dynamic range (20 nM-2.15 mM), lower detection limits (6.52 nM) and promising towards rapid screening of BPA contaminations in food and environmental samples under mimicked real-world conditions with excellent accuracy and precision.
Assuntos
Compostos Benzidrílicos , Ecossistema , Compostos Benzidrílicos/análise , Compostos de Manganês , Fenóis/análise , SulfetosRESUMO
Gold nanoparticles conjugated with collagen molecules and fibers have been proven to improve structure strength, water and enzyme degradation resistance, cell attachment, cell proliferation, and skin wound healing. In this study, high-power impulse magnetron sputtering (HiPIMS) was used to deposit ultrathin gold films (UTGF) and discontinuous island structures on type I collagen substrates. A long turn-off time of duty cycle and low chamber temperature of HiPIMS maintained substrate morphology. Increasing the deposition time from 6 s to 30 s elevated the substrate surface coverage by UTGF up to 91.79%, as observed by a field emission scanning electron microscope. X-ray diffractometry analysis revealed signature low and wide peaks for Au (111). The important surface functional groups and signature peaks of collagen substrate remained unchanged according to Fourier transform infrared spectroscopy results. Multi-peak curve fitting of the Amide I spectrum revealed the non-changed protein secondary structure of type I collagen, which mainly consists of α-helix. Atomic force microscopy observation showed that the roughness average value shifted from 1.74 to 4.17 nm by increasing the deposition time from 13 s to 77 s. The uneven surface of collagen substrate made quantification of thin film thickness by AFM difficult. Instead, UTGF thickness was measured using simultaneously deposited glass specimens placed in an HiPIMS chamber with collagen substrates. Film thickness was 3.99 and 10.37 nm at deposition times of 13 and 77 s, respectively. X-ray photoelectron spectroscopy showed preserved substrate elements on the surface. Surface water contact angle measurement revealed the same temporary hydrophobic behavior before water absorption via exposed collagen substrates, regardless of deposition time. In conclusion, HiPIMS is an effective method to deposit UTGF on biomedical materials such as collagen without damaging valuable substrates. The composition of two materials could be further used for biomedical purposes with preserved functions of UTGF and collagen.
RESUMO
Here, we present a bone implant system of phase-oriented titanium dioxide (TiO2) fabricated by the micro-arc oxidation method (MAO) on ß-Ti to facilitate improved osseointegration. This (101) rutile-phase-dominant MAO TiO2 (R-TiO2) is biocompatible due to its high surface roughness, bone-mimetic structure, and preferential crystalline orientation. Furthermore, (101) R-TiO2 possesses active and abundant hydroxyl groups that play a significant role in enhancing hydroxyapatite formation and cell adhesion and promote cell activity leading to osseointegration. The implants had been elicited their favorable cellular behavior in vitro in the previous publications; in addition, they exhibit excellent shear strength and promote bone-implant contact, osteogenesis, and tissue formation in vivo. Hence, it can be concluded that this MAO R-TiO2 bone implant system provides a favorable active surface for efficient osseointegration and is suitable for clinical applications.
Assuntos
Materiais Revestidos Biocompatíveis , Titânio , Osseointegração , Propriedades de SuperfícieRESUMO
BACKGROUND: More and more evidence has shown that non-coding RNA (ncRNA), including long ncRNA (lncRNA) and micro RNA (miRNA), plays a crucial regulatory role in osteosarcoma (OS). Previously, we revealed a Rho-related coiled coil incorporating protein kinase 1(XIAP). A transfer-related gene is negatively regulated by microRNA-20a-5p (miR-20a-5p) and plays the role of oncogene in OS. It is not clear if any lncRNA is involved in the axial upstream of miR-20a-5p/XIAP. METHODS: Expression of LSINCT5 and miR-20a-5p/XIAP in OS tissues was determined through qRT-PCR (qP). The proliferation and migration/invasion activity of OS cells were tested through CCK-8/and transwell assay, respectively. The changes on expression of XIAP were examined through qRT-PCR and Western blot (WB). Targeted binding between LSINCT5, miR-20a-5p, and XIAP has been verified using dual luciferase reporter gene analysis, RNA Immunoprecipitation (RIP), and RNA pull-down experiments. The effect of LSINCT5 on tumor growth was determined by tumor allograft test. RESULTS: In this study, elevated LSINCT5 was found in OS tissue samples and OS cell strains, and the increased LSINCT5 was strongly related to the adverse prognosis of clinical patients. Functional assays showed that inhibition of LSINCT5 could up-regulate miR-20a-5p-mediated OS cells proliferation and metastasis. WB analysis and qP analysis showed that LSINCT5 regulated XIAP by mediating miR-20a-5p. Further cell behavior experiments showed that LSINCT5 acted as a miR-20a-5p sponge to inhibit proliferation and metastasis caused by XIAP. Finally, the results of animal models in vivo showed that LSINCT5 could regulate the tumor growth of OS. CONCLUSION: LncRNA LSINCT5 acts as an oncogene and promotes XIAP mediated growth and metastasis as competitive endogenous RNA (ceRNA) in OS.
RESUMO
BACKGROUND: Melanoma is a highly malignant skin tumour, and is one of the most rapidly growing malignant tumors in recent years. According to statistics, the morbidity of cancer increases with age, accounting for 1.6% of new cancer cases and 0.6% of deaths worldwide. Melanoma has a serious impact on society and families, thus it is of great significance to find biological markers related to the diagnosis and treatment of melanoma. AIM: To explore the expression and predictive value of mir-489 and mir-21 in melanoma metastasis. METHODS: A total of 60 patients with malignant melanoma treated at our hospital from June 2017 to December 2018 were selected as a research group, while 40 healthy subjects were selected as a control group. qRT-PCR technique was used to detect miR-489 and miR-21 in serum of the two groups. ROC curve was drawn to evaluate the predictive value and diagnostic efficiency. Spearman test was used for correlation analysis. Logistic single- and multiple-factor analyses were performed to identify the risk factors related to melanoma metastasis. RESULTS: The expression of miR-489 in the research group was significantly lower than that in the control group (P < 0.001). However, the expression of miR-21 in the research group was significantly higher than that in the control group (P < 0.001). The expression of miR-489 and miR-21 was related to TNM stage and metastasis (P < 0.001). In the diagnosis of melanoma patients, the sensitivity, specificity, and AUC of miR-489 alone were 75.56%, 80.00%, and 0.852, respectively. The sensitivity, specificity, and AUC of miR-21 alone were 77.78%, 82.22%, and 0.844, respectively. MiR-489 was negatively correlated with TNM stage of melanoma (r = -0.612, P < 0.001), while miR-21 was positively correlated with TNM stage (r = 0.609, P < 0.001). Logistic single- and multiple-factor regression analyses showed that TNM stage, miR-489, and mir-21 were independent risk factors for malignant melanoma metastasis. CONCLUSION: MiR-489 and miR-21 may participate in the process of melanoma occurrence, development, and metastasis, and can be used as potential serum biomarkers for melanoma metastasis diagnosis and disease assessment.
RESUMO
To acquire device-quality TiOx films usually needs high-temperature growth or additional post-thermal treatment. However, both processes make it very difficult to form the p-type TiOx even under oxygen-poor growth condition. With the aid of high energy generated by high power impulse magnetron sputtering (HIPIMS), a highly stable p-type TiOx film with good quality can be achieved. In this research, by varying the oxygen flow rate, p-type γ-TiO and n-type TiO2 films were both prepared by HIPIMS. Furthermore, p- and n-type thin film transistors employing γ-TiO and TiO2 as channel layers possess the field-effect carrier mobilities of 0.2 and 0.7 cm2/Vs, while their on/off current ratios are 1.7 × 104 and 2.5 × 105, respectively. The first presented p-type γ-TiO TFT is a major breakthrough for fabricating the TiOx-based p-n combinational devices. Additionally, our work also confirms HIPIMS offers the possibility of growing both p- and n-type conductive oxides, significantly expanding the practical usage of this technique.
RESUMO
The goal of this work is to prepare antimicrobial, corrosion-resistant and low-cost Cu65Zn35 brass film on poly(ethylene terephthalate) (PET) fabric by high-power impulse magnetron sputtering (HIPIMS), which is known to provide high-density plasma, so as to generate a strongly adherent film at a reduced substrate temperature. The results reveal that the brass film grows in a layer-plus-island mode. Independent of their deposition time, the obtained films retain a Cu/Zn elemental composition ratio of 1.86 and exhibit primarily an α copper phase structure. Oxygen plasma pre-treatment for 1min before coating can significantly increase film adhesion such that the brass-coated fabric of Grade 5 or Grade 4-5 can ultimately be obtained under dry and wet rubbing tests, respectively. However, a deposition time of 1min suffices to provide effective antimicrobial properties for both Staphylococcus aureus and Escherichia coli. As a whole, the feasibility of using such advanced HIPIMS coating technique to develop durable antimicrobial textile was demonstrated.
Assuntos
Anti-Infecciosos/química , Anti-Infecciosos/farmacologia , Polietilenotereftalatos/química , Têxteis , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/economia , Cobre , Corrosão , Escherichia coli/efeitos dos fármacos , Teste de Materiais/métodos , Staphylococcus aureus/efeitos dos fármacos , ZincoRESUMO
Polyetheretherketone (PEEK), which has biomechanical performance similar to that of human cancellous bone, is used widely as a spinal implant material. However, its bioinertness and hydrophobic surface properties result in poor osseointegration. This study applies a novel modification method, arc ion plating (AIP), that produces a highly osteoblast compatible titanium dioxide (TiO2) coatings on a PEEK substrate. This PEEK with TiO2 coating (TiO2/PEEK) was implanted into the femurs of New Zealand white male rabbits to evaluate its in vivo performance by the push-out test and histological observation. Analytical results show that AIP can prepare TiO2 coatings on bullet-shaped PEEK substrates as implant materials. After prolonged implantation in rabbits, no signs of inflammation existed. Newly regenerated bone formed more prominently with the TiO2/PEEK implant by histological observation. The shear strength of the bone/implant interface increases as implantation period increases. Most importantly, bone bonding performance of the TiO2/PEEK implant was superior to that of bare PEEK. The rutile-TiO2 coatings achieved better osseointegration than the anatase-TiO2 coatings. Therefore, AIP-TiO2 can serve as a novel surface modification method on PEEK for spinal interbody fusion cages.
Assuntos
Materiais Revestidos Biocompatíveis/química , Cetonas , Osseointegração , Polietilenoglicóis , Próteses e Implantes , Titânio , Animais , Benzofenonas , Fêmur/cirurgia , Humanos , Masculino , Teste de Materiais , Microscopia Eletrônica de Varredura , Polímeros , Coelhos , Resistência ao Cisalhamento , Coluna Vertebral/cirurgia , Propriedades de Superfície , Fatores de TempoRESUMO
This study utilizes a novel technique, high power impulse magnetron sputtering (HIPIMS), which provides a higher ionization rate and ion bombardment energy than direct current magnetron sputtering (DCMS), to deposit high osteoblast compatible titanium dioxide (TiO2) coatings with anatase (A-TiO2) and rutile (R-TiO2) phases onto the biomedical polyetheretherketone (PEEK) polymer substrates at low temperature. The adhesions of TiO2 coatings that were fabricated using HIPIMS and DCMS were compared. The in vitro biocompatibility of these coatings was confirmed. The results reveal that HIPIMS can be used to prepare crystallinic columnar A-TiO2 and R-TiO2 coatings on PEEK substrate if the ratio of oxygen to argon is properly controlled. According to a tape adhesion test, the HIPIMS-TiO2 coatings had an adhesion grade of 5B even after they were immersed in simulated body fluid (SBF) environments for 28days. Scratch tests proved that HIPIMS-TiO2 coatings undergo cohesive failure. These results demonstrate that the adhesive force between HIPIMS-TiO2 coating/PEEK is stronger than that between DCMS-TiO2 coating/PEEK. After a long period (28days) of immersion in SBF, a bone-like crystallinic hydroxyapatite layer with a corresponding Ca/P stoichiometry was formed on both HIPIMS-TiO2. The osteoblast compatibility of HIPIMS-TiO2 exceeded that of the bare PEEK substrate. It is also noticeable that the R-TiO2 performed better in vitro than the A-TiO2 due to the formation of many negatively charged hydroxyl groups (-OH(-)) groups on R-TiO2 (110) surface. In summary, the HIPIMS-TiO2 coatings satisfied the requirements for osseointegration, suggesting the possibility of using HIPIMS to modify the PEEK surface with TiO2 for spinal implants.
Assuntos
Substitutos Ósseos/química , Substitutos Ósseos/efeitos da radiação , Cetonas/química , Osteoblastos/fisiologia , Polietilenoglicóis/química , Titânio/química , Titânio/efeitos da radiação , Animais , Células 3T3 BALB , Benzofenonas , Adesão Celular/fisiologia , Linhagem Celular , Proliferação de Células/fisiologia , Sobrevivência Celular/fisiologia , Cetonas/efeitos da radiação , Camundongos , Micro-Ondas , Osteoblastos/citologia , Polietilenoglicóis/efeitos da radiação , Polímeros , Propriedades de Superfície/efeitos da radiaçãoRESUMO
Reducing the osseointegration time for biomedical titanium implants in surgical patients is an important goal. However, a huge controversy exists over the effectiveness of osseointegration of the surface layer by plasma electrolytic oxidation (PEO), which is a widely favored surface modification for titanium-based implants. In this study, various surface coatings, including anatase-TiO2 (A-TiO2 ), rutile-TiO2 (R-TiO2 ), hydroxyapatite (HAp), strontium-containing hydroxyapatite (Sr-HAp), and dual-phase HAp-TiO2 were synthesized on titanium implants by PEO. A comparative study of osseointegration performance (both in vitro and in vivo) and bone/implant adhesion strength conducted using push-out thrust tests were demonstrated. The in vitro experimental test results agree strongly with the in vivo test results: the dual-phase HAp-TiO2 coating exhibits the superior cell adhesion and differentiation condition among all of the coatings in the in vitro tests and therefore has the highest push-out bonding strength of 5.37 MPa after 12 wk of implantation in the in vivo test. The HAp-containing coatings benefit from its bioactivity and therefore perform the others in terms of long-term osteocyte growth (from the in vitro results) and the extent of osseointegration (from the in vivo results). The dual-phase HAp-TiO2 coating provides the advantages of both the bioactive HAp and structural enhancement by the TiO2 , effectively promoting osseointegration.
Assuntos
Materiais Revestidos Biocompatíveis/química , Osseointegração , Titânio/química , Células 3T3 , Animais , Eletrólise , Teste de Materiais , Camundongos , Osteoblastos/citologia , Osteoblastos/metabolismo , Oxirredução , Gases em Plasma , Próteses e Implantes , Coelhos , Propriedades de SuperfícieRESUMO
Titanium dioxide (TiO(2)), known to exhibit good biocompatibility, is applied in this study as a thin film formed onto polyetheretherketone (PEEK) substrate, which has been widely used in spinal interbody fusion cages. For successful deposition, an arc ionplating (AIP) technique was applied to deposit TiO(2) at low deposition temperature without damaging PEEK substrate, while providing satisfactory film adhesion. This study systematically investigates the effects of TiO(2) thin film phase composition and surface characteristics, controlled by using different target current and substrate bias, on osteoblast compatibility. Experimental results showed that anatase phase (A-TiO(2)) and/or rutile phase (R-TiO(2) ) TiO(2) coatings, respectively, can be prepared in appropriate deposition conditions. Overall, the TiO(2)-coated PEEK presented better osteoblast compatibility than the bare PEEK material in terms of cell adhesion, cell proliferation, and cell differentiation abilities, as well as osteogenesis performance (as determined by levels of osteopontin, osteocalcin, and calcium content). Surface roughness and hydrophilicity of the AIP-TiO(2) films were found to be responsible for significant osteoblast cell growth. It is also noticeable that the R-TiO(2) exhibited better osteoblast compatibility than the A-TiO(2) due to the presence of negatively charged hydroxyl groups on R-TiO(2) (110) surface in nature.
Assuntos
Materiais Revestidos Biocompatíveis/farmacologia , Galvanoplastia/métodos , Cetonas/farmacologia , Osteoblastos/citologia , Polietilenoglicóis/farmacologia , Próteses e Implantes , Medula Espinal/fisiologia , Titânio/química , Animais , Benzofenonas , Células Cultivadas , Cristalografia , Teste de Materiais , Camundongos , Osteoblastos/efeitos dos fármacos , Osteoblastos/ultraestrutura , Polímeros , Medula Espinal/efeitos dos fármacos , Propriedades de Superfície , Água/química , Difração de Raios XRESUMO
Titanium dioxide (TiO2) has been developed and applied extensively in the form of coatings, in particular for its unique properties such as non-toxicity, high photocatalytic activity, and strong self-cleaning ability. These coatings, which can be prepared via various processes, have not yet been proved to be antimicrobial. This research involves an arc ion plating method to produce TiO2 film on medical grade AISI 304 stainless steel. Antimicrobial efficacy of the deposits is expected due to the photocatalysis action of the anatase phase presented in the deposit. The performance of the coating is evaluated by a JIS Z2801:2000 industrial standard. Experimental results show that TiO2 film mainly consisting of anatase structure can be prepared with a high growth rate of 5 microm/h. Antimicrobial activity (R) of the deposited TiO2 film against Staphylococcus aureus and Escherichia coli was 3.0 and 2.5, respectively, far beyond the value designated in JIS standard. This provides an effective antimicrobial surface coating method for medical implements thereby reducing the risk of hospital-acquired infections.