Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Interv Cardiol ; 26(2): 131-6, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23369084

RESUMO

OBJECTIVE: To evaluate clinical and angiographic outcomes using a 1.20 mm diameter angioplasty catheter as part of a predilation strategy for coronary lesion treatment. BACKGROUND: Development of an angioplasty catheter with low crossing profile and small balloon diameter represents an opportunity to facilitate percutaneous revascularization of complex coronary disease. METHODS: Clinical and angiographic outcomes were evaluated following a predilation treatment strategy using a low profile, 1.20 mm angioplasty catheter. The primary end-point of procedural success was defined as successful device delivery, performance and lesion treatment without occurrence of perforation, flow-limiting dissection, reduction in baseline TIMI grade, or clinically significant arrhythmias, and with final achievement of TIMI 3 flow. In-hospital major adverse events were also determined. RESULTS: Among 71 patients (83 lesions), angiographic characteristics included: de novo lesion, 75.9%; saphenous vein graft 9.6%; lesion length (mean ± standard deviation), 12.27 ± 5.96 mm; reference vessel diameter, 2.61 ± 0.57 mm; lesion classification B2/C, 59.0%; baseline TIMI 0/1 flow, 4.8%. Procedural success was achieved for 98.5% (66/67) of patients. Catheter delivery to the target lesion was achieved in all patients, and the rate of device success with luminal improvement after predilation was 96.2% (75/78). No acute procedural complications were observed, and in-hospital target lesion failure occurred in 6 patients (8.5%) related to peri-procedural non-Q wave myocardial infarction. CONCLUSIONS: Coronary lesion predilation with a low profile, 1.20 mm angioplasty catheter is associated with favorable procedural safety and efficacy and may represent an effective treatment for complex coronary anatomy.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateterismo/instrumentação , Angiografia Coronária/métodos , Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/instrumentação , Complicações Pós-Operatórias/epidemiologia , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Cateterismo/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa