Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Magn Reson Med ; 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39044620

RESUMO

PURPOSE: To develop and evaluate a robust cardiac B 1 + $$ {\mathrm{B}}_1^{+} $$ mapping sequence at 3 T, using Bloch-Siegert shift (BSS)-based preparations. METHODS: A longitudinal magnetization preparation module was designed to encode | B 1 + | $$ \mid {\mathrm{B}}_1^{+}\mid $$ . After magnetization tip-down, off-resonant Fermi pulses, placed symmetrically around two refocusing pulses, induced BSS, followed by tipping back of the magnetization. Bloch simulations were used to optimize refocusing pulse parameters and to assess the mapping sensitivity. Relaxation-induced B 1 + $$ {\mathrm{B}}_1^{+} $$ error was simulated for various T 1 $$ {\mathrm{T}}_1 $$ / T 2 $$ {\mathrm{T}}_2 $$ times. The effective mapping range was determined in phantom experiments, and | B 1 + | $$ \mid {\mathrm{B}}_1^{+}\mid $$ maps were compared to the conventional BSS method and subadiabatic hyperbolic-secant 8 (HS8) pulse-sensitized method. Cardiac B 1 + $$ {\mathrm{B}}_1^{+} $$ maps were acquired in healthy subjects, and evaluated for repeatability and imaging plane intersection consistency. The technique was modified for three-dimensional (3D) acquisition of the whole heart in a single breath-hold, and compared to two-dimensional (2D) acquisition. RESULTS: Simulations indicate that the proposed preparation can be tailored to achieve high mapping sensitivity across various B 1 + $$ {\mathrm{B}}_1^{+} $$ ranges, with maximum sensitivity at the upper B 1 + $$ {\mathrm{B}}_1^{+} $$ range. T 1 $$ {\mathrm{T}}_1 $$ / T 2 $$ {\mathrm{T}}_2 $$ -induced bias did not exceed 5.2 % $$ \% $$ . Experimentally reproduced B 1 + $$ {\mathrm{B}}_1^{+} $$ sensitization closely matched simulations for B 1 + ≥ 0 . 3 B 1 , max + $$ {\mathrm{B}}_1^{+}\ge 0.3{\mathrm{B}}_{1,\max}^{+} $$ (mean difference 0.031 ± $$ \pm $$ 0.022, compared to 0.018 ± $$ \pm $$ 0.025 in the HS8-sensitized method), and showed 20-fold reduction in the standard deviation of repeated scans, compared with conventional BSS B 1 + $$ {\mathrm{B}}_1^{+} $$ mapping, and an equivalent 2-fold reduction compared with HS8-sensitization. Robust cardiac B 1 + $$ {\mathrm{B}}_1^{+} $$ map quality was obtained, with an average test-retest variability of 0.027 ± $$ \pm $$ 0.043 relative to normalized B 1 + $$ {\mathrm{B}}_1^{+} $$ magnitude, and plane intersection bias of 0.052 ± $$ \pm $$ 0.031. 3D acquisitions showed good agreement with 2D scans (mean absolute deviation 0.055 ± $$ \pm $$ 0.061). CONCLUSION: BSS-based preparations enable robust and tailorable 2D/3D cardiac B 1 + $$ {\mathrm{B}}_1^{+} $$ mapping at 3 T in a single breath-hold.

2.
Magn Reson Med ; 87(5): 2347-2362, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34985143

RESUMO

PURPOSE: To implement and evaluate a new dictionary-based technique for native myocardial T1 and T2 mapping using Cartesian sampling. METHODS: The proposed technique (Multimapping) consisted of single-shot Cartesian image acquisitions in 10 consecutive cardiac cycles, with inversion pulses in cycle 1 and 5, and T2 preparation (TE: 30 ms, 50 ms, and 70 ms) in cycles 8-10. Multimapping was simulated for different T1 and T2 , where entries corresponding to the k-space centers were matched to acquired data. Experiments were performed in a phantom, 16 healthy subjects, and 3 patients with cardiovascular disease. RESULTS: Multimapping phantom measurements showed good agreement with reference values for both T1 and T2 , with no discernable heart-rate dependency for T1 and T2 within the range of myocardium. In vivo mean T1 in healthy subjects was significantly higher using Multimapping (T1 = 1114 ± 14 ms) compared to the reference (T1 = 991 ± 26 ms) (p < 0.01). Mean Multimapping T2 (47.1 ± 1.3 ms) and T2 spatial variability (5.8 ± 1.0 ms) was significantly lower compared to the reference (T2 = 54.7 ± 2.2 ms, p < 0.001; spatial variability = 8.4 ± 2.0 ms, p < 0.01). Increased T1 and T2 was detected in all patients using Multimapping. CONCLUSIONS: Multimapping allows for simultaneous native myocardial T1 and T2 mapping with a conventional Cartesian trajectory, demonstrating promising in vivo image quality and parameter quantification results.


Assuntos
Coração , Miocárdio , Imagens de Fantasmas , Coração/diagnóstico por imagem , Humanos , Valores de Referência , Reprodutibilidade dos Testes
3.
J Magn Reson Imaging ; 55(1): 61-80, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33078512

RESUMO

MRI is a versatile technique that offers many different options for tissue contrast, including suppressing the blood signal, so-called black-blood contrast. This contrast mechanism is extremely useful to visualize the vessel wall with high conspicuity or for characterization of tissue adjacent to the blood pool. In this review we cover the physics of black-blood contrast and different techniques to achieve blood suppression, from methods intrinsic to the imaging readout to magnetization preparation pulses that can be combined with arbitrary readouts, including flow-dependent and flow-independent techniques. We emphasize the technical challenges of black-blood contrast that can depend on flow and motion conditions, additional contrast weighting mechanisms (T1 , T2 , etc.), magnetic properties of the tissue, and spatial coverage. Finally, we describe specific implementations of black-blood contrast for different vascular beds. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY STAGE: 5.


Assuntos
Imageamento por Ressonância Magnética , Física
4.
J Magn Reson Imaging ; 56(5): 1393-1403, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35128754

RESUMO

BACKGROUND: Epicardial adipose tissue (EAT) may induce left atrium (LA) wall inflammation and promote LA fibrosis. Therefore, simultaneous assessment of these two important atrial fibrillation (AF) risk factors would be desirable. PURPOSE: To perform a comprehensive evaluation of 3D Dixon water-fat separated late gadolinium enhancement (LGE-Dixon) MRI by analysis of repeatability and systematic comparison with reference methods for assessment of fibrosis and fat. STUDY TYPE: Prospective. POPULATION: Twenty-eight, 10, and 7 patients, respectively, with clinical indications for cardiac MRI. FIELD STRENGTH/SEQUENCE: A 1.5-T scanner, inversion recovery multiecho spoiled gradient echo. ASSESSMENT: Twenty-eight patients (age 58 ± 19 years, 15 males) were scanned using LGE-Dixon. A 5-point Likert-type scale was used to grade the image quality. Another 10 patients (age 46 ± 19 years, 9 males) were scanned using LGE-Dixon and 3D proton density Dixon (PD-Dixon). Finally, seven patients (age 62 ± 14 years, 4 males) were scanned using LGE-Dixon and conventional LGE. The scan time, intraobserver and interobserver variability, and levels of agreement were assessed. STATISTICAL TESTS: Student's t-test, one-way ANOVA, and Mann-Whitney U-test were used; P < 0.05 was considered significant, intraclass correlation coefficient (ICC). RESULTS: The scan time (minutes:seconds) for LGE-Dixon (n = 28) was 5:01 ± 1:40. ICC values for intraobserver and interobserver measurements of LA wall fibrosis percentage were 0.98 (95% CI, 0.97-0.99) and 0.97 (95% CI, 0.94-0.99) while of EAT were 0.92 (95% CI, 0.82-0.97) and 0.90 (95% CI, 0.80-0.95). The agreement for LA fibrosis percentage between the LGE-Dixon and the conventional LGE was 0.92 (95% CI, 0.66-0.99) and for EAT volume between the LGE-Dixon and the PD-Dixon was 0.93 (95% CI, 0.72-0.98). CONCLUSION: LA fibrosis and EAT can be assessed simultaneously using LGE-Dixon. This method allows a high level of intraobserver and interobserver repeatability as well as agreement with reference methods and can be performed in a clinically feasible scan time. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY STAGE: 3.


Assuntos
Fibrilação Atrial , Gadolínio , Tecido Adiposo/diagnóstico por imagem , Adulto , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/patologia , Meios de Contraste , Fibrose , Átrios do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Prótons , Água
5.
MAGMA ; 35(5): 711-718, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34958438

RESUMO

OBJECTIVE: To evaluate systolic flow-sensitive alternating inversion recovery (FAIR) during rest and exercise stress using 2RR (two cardiac cycles) or 1RR intervals between inversion pulse and imaging. MATERIALS AND METHODS: 1RR and 2RR FAIR was implemented on a 3T scanner. Ten healthy subjects were scanned during rest and stress. Stress was performed using an in-bore ergometer. Heart rate, mean myocardial blood flow (MBF) and temporal signal-to-noise ratio (TSNR) were compared using paired t tests. RESULTS: Mean heart rate during stress was higher than rest for 1RR FAIR (85.8 ± 13.7 bpm vs 63.3 ± 11.1 bpm; p < 0.01) and 2RR FAIR (83.8 ± 14.2 bpm vs 63.1 ± 10.6 bpm; p < 0.01). Mean stress MBF was higher than rest for 1RR FAIR (2.97 ± 0.76 ml/g/min vs 1.43 ± 0.6 ml/g/min; p < 0.01) and 2RR FAIR (2.8 ± 0.96 ml/g/min vs 1.22 ± 0.59 ml/g/min; p < 0.01). Resting mean MBF was higher for 1RR FAIR than 2RR FAIR (p < 0.05), but not during stress. TSNR was lower for stress compared to rest for 1RR FAIR (4.52 ± 2.54 vs 10.12 ± 3.69; p < 0.01) and 2RR FAIR (7.36 ± 3.78 vs 12.41 ± 5.12; p < 0.01). 2RR FAIR TSNR was higher than 1RR FAIR for rest (p < 0.05) and stress (p < 0.001). DISCUSSION: We have demonstrated feasibility of systolic FAIR in rest and exercise stress. 2RR delay systolic FAIR enables non-contrast perfusion assessment during stress with relatively high TSNR.


Assuntos
Imagem de Perfusão do Miocárdio , Circulação Coronária/fisiologia , Coração , Humanos , Imagem de Perfusão do Miocárdio/métodos , Perfusão , Razão Sinal-Ruído
6.
NMR Biomed ; 34(2): e4436, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33150707

RESUMO

Quantitative myocardial perfusion can be achieved without contrast agents using flow-sensitive alternating inversion recovery (FAIR) arterial spin labeling. However, FAIR has an intrinsically low sensitivity, which may be improved by mitigating the effects of physiological noise or by increasing the area of artifact-free myocardium. The aim of this study was to investigate if systolic FAIR may increase the amount of analyzable myocardium compared with diastolic FAIR and its effect on physiological noise. Furthermore, we compare parallel imaging acceleration with a factor of 2 with compressed sensing acceleration with a factor of 3 for systolic FAIR. Twelve healthy subjects were scanned during rest on a 3 T scanner using diastolic FAIR with parallel imaging factor 2 (FAIR-PI2D ), systolic FAIR with the same acceleration (FAIR-PI2S ) and systolic FAIR with compressed sensing factor 3 (FAIR-CS3S ). The number of analyzable pixels in the myocardium, temporal signal-to-noise ratio (TSNR) and mean myocardial blood flow (MBF) were calculated for all methods. The number of analyzable pixels using FAIR-CS3S (663 ± 55) and FAIR-PI2S (671 ± 58) was significantly higher than for FAIR-PI2D (507 ± 82; P = .001 for both), while there was no significant difference between FAIR-PI2S and FAIR-CS3S . The mean TSNR of the midventricular slice for FAIR-PI2D was 11.4 ± 3.9, similar to that of FAIR-CS3S, which was 11.0 ± 3.3, both considerably higher than for FAIR-PI2S, which was 8.4 ± 3.1 (P < .05 for both). Mean MBF was similar for all three methods. The use of compressed sensing accelerated systolic FAIR benefits from an increased number of analyzable myocardial pixels compared with diastolic FAIR without suffering from a TSNR penalty, unlike systolic FAIR with parallel imaging acceleration.


Assuntos
Angiografia/métodos , Vasos Coronários/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Processamento de Sinais Assistido por Computador , Adulto , Compressão de Dados , Diástole , Feminino , Frequência Cardíaca , Hemorreologia , Humanos , Masculino , Descanso , Marcadores de Spin , Sístole
7.
Magn Reson Med ; 84(6): 3308-3315, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32459007

RESUMO

PURPOSE: Late gadolinium enhancement (LGE) of the left atrium is susceptible to artifacts arising from the right pulmonary veins, caused by inflowing blood tagged by the navigator restore pulse. The purpose of this study was to evaluate a new method to reduce the inflow artifact using an adaptive flip-angle restore pulse. METHODS: A low-restore angle reduces the inflow artifact but may lead to a poor navigator SNR. The proposed approach aims to determine the patient-specific restore angle, which optimizes the trade-off between inflow artifacts and navigator SNR. Three-dimensional LGE with adaptive navigator restore (3D LGEA ) was implemented by incrementing the flip angle of the restore pulse from a starting value of 0°, based on the navigator normalized cross-correlation. Magnetic resonance imaging experiments were performed on a 1.5T scanner. The value of 3D LGEA was compared with 3D LGE with a constant 180° restore pulse (3D LGE180 ) in 22 patients with heart diseases. The values of 3D LGEA and 3D LGE180 were compared in terms of pulmonary vein blood signal relative to reference blood in the descending aorta (PVrel ) and visual scoring to determine level of motion artifacts using a 4-point scale (1 = severe artifacts; 4 = no artifacts). RESULTS: The value of PVrel was significantly lower for 3D LGEA than for 3D LGE180 (1.16 ± 0.23 vs. 1.59 ± 0.29, P < .001). Furthermore, visual scoring of the motion artifacts yielded no difference (P = .78). CONCLUSION: Adaptively adjusting the navigator restore flip angle based on the navigator normalized cross-correlation reduces the 3D LGE inflow artifact without affecting image quality or the scan time.


Assuntos
Artefatos , Gadolínio , Meios de Contraste , Átrios do Coração/diagnóstico por imagem , Humanos , Aumento da Imagem , Imageamento Tridimensional , Imageamento por Ressonância Magnética
8.
Magn Reson Med ; 83(1): 178-187, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31400054

RESUMO

PURPOSE: To combine a 3D saturation-recovery-based myocardial T1 mapping (3D SASHA) sequence with a 2D image navigator with fat excitation (fat-iNAV) to allow 3D T1 maps with 100% respiratory scan efficiency and predictable scan time. METHODS: Data from T1 phantom and 10 subjects were acquired at 1.5T. For respiratory motion compensation, a 2D fat-iNAV was acquired before each 3D SASHA k-space segment to correct for 2D translational motion in a beat-to-beat fashion. The effect of the fat-iNAV on the 3D SASHA T1 estimation was evaluated on the T1 phantom. For 3 representative subjects, the proposed free-breathing 3D SASHA with fat-iNAV was compared to the original implementation with the diaphragmatic navigator. The 3D SASHA with fat-iNAV was compared to the breath-hold 2D SASHA sequence in terms of accuracy and precision. RESULTS: In the phantom study, the Bland-Altman plot shows that the 2D fat-iNAVs does not affect the T1 quantification of the 3D SASHA acquisition (0 ± 12.5 ms). For the in vivo study, the 2D fat-iNAV permits to estimate the respiratory motion of the heart, while allowing for 100% scan efficiency, improving the precision of the T1 measurement compared to non-motion-corrected 3D SASHA. However, the image quality achieved with the proposed 3D SASHA with fat-iNAV is lower compared to the original implementation, with reduced delineation of the myocardial borders and papillary muscles. CONCLUSIONS: We demonstrate the feasibility to combine the 3D SASHA T1 mapping imaging sequence with a 2D fat-iNAV for respiratory motion compensation, allowing 100% respiratory scan efficiency and predictable scan time.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Respiração , Adulto , Algoritmos , Suspensão da Respiração , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Masculino , Miocárdio , Imagens de Fantasmas , Reprodutibilidade dos Testes
9.
BMC Med Imaging ; 20(1): 80, 2020 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-32664848

RESUMO

BACKGROUND: There is an increased interest in quantifying and characterizing epicardial fat which has been linked to various cardiovascular diseases such as coronary artery disease and atrial fibrillation. Recently, three-dimensional single-phase Dixon techniques have been used to depict the heart and to quantify the surrounding fat. The purpose of this study was to investigate the merits of a new high-resolution cine 3D Dixon technique for quantification of epicardial adipose tissue and compare it to single-phase 3D Dixon in patients with cardiovascular disease. METHODS: Fifteen patients referred for clinical CMR examination of known or suspected heart disease were scanned on a 1.5 T scanner using single-phase Dixon and cine Dixon. Epicardial fat was segmented by three readers and intra- and inter-observer variability was calculated per slice. Cine Dixon segmentation was performed in the same cardiac phase as single-phase Dixon. Subjective image quality assessment of water and fat images were performed by three readers using a 4-point Likert scale (1 = severe; 2 = significant; 3 = mild; 4 = no blurring of cardiac structures). RESULTS: Intra-observer variability was excellent for cine Dixon images (ICC = 0.96), and higher than single-phase Dixon (ICC = 0.92). Inter-observer variability was good for cine Dixon (ICC = 0.76) and moderate for single-phase Dixon (ICC = 0.63). The intra-observer measurement error (mean ± standard deviation) per slice for cine was - 0.02 ± 0.51 ml (- 0.08 ± 0.4%), and for single-phase 0.39 ± 0.72 ml (0.18 ± 0.41%). Inter-observer measurement error for cine was 0.46 ± 0.98 ml (0.11 ± 0.46%) and for single-phase 0.42 ± 1.53 ml (0.17 ± 0.47%). Visual scoring of the water image yielded median of 2 (interquartile range = [Q3-Q1] 2-2) for cine and median of 3 (interquartile range = 3-2) for single-phase (P < 0.05) while no significant difference was found for the fat images, both techniques yielding a median of 3 and interquartile range of 3-2. CONCLUSION: Cine Dixon can be used to quantify epicardial fat with lower intra- and inter-observer variability compared to standard single-phase Dixon. The time-resolved information provided by the cine acquisition appears to support the delineation of the epicardial adipose tissue depot.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Doenças Cardiovasculares/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Pericárdio/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudo de Prova de Conceito
10.
J Cardiovasc Magn Reson ; 21(1): 13, 2019 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-30798789

RESUMO

AIMS: To investigate the use of respiratory motion compensation using image-based navigation (iNAV) with constant respiratory efficiency using single end-expiratory thresholding (CRUISE) for coronary magnetic resonance angiography (CMRA), and compare it to the conventional diaphragmatic navigator (dNAV) in paediatric patients with congenital or suspected heart disease. METHODS: iNAV allowed direct tracking of the respiratory heart motion and was generated using balanced steady state free precession startup echoes. Respiratory gating was achieved using CRUISE with a fixed 50% efficiency. Whole-heart CMRA was acquired with 1.3 mm isotropic resolution. For comparison, CMRA with identical imaging parameters were acquired using dNAV. Scan time, visualization of coronary artery origins and mid-course, imaging quality and sharpness was compared between the two sequences. RESULTS: Forty patients (13 females; median weight: 44 kg; median age: 12.6, range: 3 months-17 years) were enrolled. 25 scans were performed in awake patients. A contrast agent was used in 22 patients. The scan time was significantly reduced using iNAV for awake patients (iNAV 7:48 ± 1:26 vs dNAV 9:48 ± 3:11, P = 0.01) but not for patients under general anaesthesia (iNAV = 6:55 ± 1:50 versus dNAV = 6:32 ± 2:16; P = 0.32). In 98% of the cases, iNAV image quality had an equal or higher score than dNAV. The visual score analysis showed a clear difference, favouring iNAV (P = 0.002). The right coronary artery and the left anterior descending vessel sharpness was significantly improved (iNAV: 56.8% ± 10.1% vs dNAV: 53.7% ± 9.9%, P < 0.002 and iNAV: 55.8% ± 8.6% vs dNAV: 53% ± 9.2%, P = 0.001, respectively). CONCLUSION: iNAV allows for a higher success-rate and clearer depiction of the mid-course of coronary arteries in paediatric patients. Its acquisition time is shorter in awake patients and image quality score is equal or superior to the conventional method in most cases.


Assuntos
Vasos Coronários/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Angiografia por Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Respiração , Adolescente , Artefatos , Criança , Pré-Escolar , Meios de Contraste/administração & dosagem , Vasos Coronários/fisiopatologia , Feminino , Cardiopatias Congênitas/fisiopatologia , Humanos , Lactente , Masculino , Meglumina/administração & dosagem , Compostos Organometálicos/administração & dosagem , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Tempo , Fluxo de Trabalho
11.
MAGMA ; 32(2): 281-289, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30191345

RESUMO

PURPOSE: To improve the precision of a free-breathing 3D saturation-recovery-based myocardial T1 mapping sequence using a post-processing 3D denoising technique. METHODS: A T1 phantom and 15 healthy subjects were scanned on a 1.5 T MRI scanner using 3D saturation-recovery single-shot acquisition (SASHA) for myocardial T1 mapping. A 3D denoising technique was applied to the native T1-weighted images before pixel-wise T1 fitting. The denoising technique imposes edge-preserving regularity and exploits the co-occurrence of 3D spatial gradients in the native T1-weighted images by incorporating a multi-contrast Beltrami regularization. Additionally, 2D modified Look-Locker inversion recovery (MOLLI) acquisitions were performed for comparison purposes. Accuracy and precision were measured in the myocardial septum of 2D MOLLI and 3D SASHA T1 maps and then compared. Furthermore, the accuracy and precision of the proposed approach were evaluated in a standardized phantom in comparison to an inversion-recovery spin-echo sequence (IRSE). RESULTS: For the phantom study, Bland-Altman plots showed good agreement in terms of accuracy between IRSE and 3D SASHA, both on non-denoised and denoised T1 maps (mean difference -1.4 ± 18.9 ms and -4.4 ± 21.2 ms, respectively), while 2D MOLLI generally underestimated the T1 values (69.4 ± 48.4 ms). For the in vivo study, there was a statistical difference between the precision measured on 2D MOLLI and on non-denoised 3D SASHA T1 maps (P = 0.005), while there was no statistical difference after denoising (P = 0.95). CONCLUSION: The precision of 3D SASHA myocardial T1 mapping was substantially improved using a 3D Beltrami regularization based denoising technique and was similar to that of 2D MOLLI T1 mapping, while preserving the higher accuracy and whole-heart coverage of 3D SASHA.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Coração/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Técnicas de Imagem Cardíaca/estatística & dados numéricos , Estudos de Viabilidade , Voluntários Saudáveis , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/estatística & dados numéricos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Imagens de Fantasmas , Reprodutibilidade dos Testes
12.
MAGMA ; 32(2): 291, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30298196

RESUMO

The original version of this article unfortunately contained a mistake. The presentation of Equation was incorrect. The corrected equation is given below.

13.
Magn Reson Med ; 79(1): 416-422, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28321900

RESUMO

PURPOSE: The purpose of this study was to evaluate a new inline motion compensation approach called image-based navigation with Constant Respiratory efficiency UsIng Single End-expiratory threshold (iNAV-CRUISE) for coronary MR angiography (CMRA). METHODS: The CRUISE gating technique was combined with iNAV motion correction and implemented inline for motion-compensated CMRA on a 1.5 Tesla scanner. The approach was compared to conventional diaphragmatic navigator gating (dNAVG) in 10 healthy subjects. The CMRA images were compared for vessel sharpness and visual score of the right coronary artery (RCA), left anterior descending artery (LAD), left circumflex, and scan time. RESULTS: The scan time was similar between the methods (dNAVG : 6:32 ± 1:09 vs. iNAV-CRUISE: 6:58 ± 0:17, P = not significant). However, the vessel sharpness of the RCA (dNAVG : 60.2 ± 10.1 vs. iNAV-CRUISE: 71.8 ± 8.9, P = 0.001) and LAD (dNAVG : 58.0 ± 8.0 vs. iNAV-CRUISE: 67.4 ± 7.1, P = 0.008) were significantly improved using iNAV-CRUISE. The visual score of the RCA was higher using iNAV-CRUISE compared to dNAVG (dNAVG : 3,4,3 vs. iNAV-CRUISE: 4,4,3, P < 0.01). CONCLUSION: The iNAV-CRUISE approach out-performs the conventional respiratory motion compensation technique in healthy subjects. Although scan time was comparable, the image quality was improved using iNAV-CRUISE. Magn Reson Med 79:416-422, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Assuntos
Angiografia Coronária , Coração/diagnóstico por imagem , Angiografia por Ressonância Magnética , Adulto , Algoritmos , Artérias/diagnóstico por imagem , Artefatos , Vasos Coronários/diagnóstico por imagem , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Movimento (Física) , Respiração
14.
J Cardiovasc Magn Reson ; 20(1): 76, 2018 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-30474554

RESUMO

BACKGROUND: Volumetric black-blood cardiovascular magnetic resonance (CMR) has been hampered by long scan times and flow sensitivity. The purpose of this study was to assess the feasibility of black-blood, electrocardiogram (ECG)-triggered and respiratory-navigated 3D fast spin echo (3D FSE) for the visualization of the whole heart and great vessels. METHODS: The implemented 3D FSE technique used slice-selective excitation and non-selective refocusing pulses with variable flip angles to achieve constant echo signal for tissue with T1 (880 ms) and T2 (40 ms) similar to the vessel wall. Ten healthy subjects and 21 patients with congenital heart disease (CHD) underwent 3D FSE and conventional 3D balanced steady-state free precession (bSSFP). The sequences were compared in terms of ability to perform segmental assessment, local signal-to-noise ratio (SNRl) and local contrast-to-noise ratio (CNRl). RESULTS: In both healthy subjects and patients with CHD, 3D FSE showed superior pulmonary vein but inferior coronary artery origin visualisation compared to 3D bSFFP. However, in patients with CHD the combination of 3D bSSFP and 3D FSE whole-heart imaging improves the success rate of cardiac morphological diagnosis to 100% compared to either technique in isolation (3D FSE, 23.8% success rate, 3D bSSFP, 5% success rate). In the healthy subjects SNRl for 3D bSSFP was greater than for 3D FSE (30.1 ± 7.3 vs 20.9 ± 5.3; P = 0.002) whereas the CNRl was comparable (17.3 ± 5.6 vs 17.4 ± 4.9; P = 0.91) between the two scans. CONCLUSIONS: The feasibility of 3D FSE for whole-heart black-blood CMR imaging has been demonstrated. Due to their high success rate for segmental assessment, the combination of 3D bSSFP and 3D FSE may be an attractive alternative to gadolinium contrast enhanced morphological CMR in patients with CHD.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Cardiopatias Congênitas/diagnóstico por imagem , Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Eletrocardiografia , Estudos de Viabilidade , Feminino , Coração/fisiopatologia , Cardiopatias Congênitas/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Circulação Pulmonar , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Adulto Jovem
15.
BMC Med Imaging ; 18(1): 36, 2018 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-30326847

RESUMO

BACKGROUND: Dual-phase 3-dimensional whole-heart acquisition allows simultaneous imaging during systole and diastole. Respiratory navigator gating and tracking of the diaphragm is used with limited accuracy. Prolonged scan time is common, and navigation often fails in patients with erratic breathing. Image-navigation (iNAV) tracks movement of the heart itself and is feasible in single phase whole heart imaging. To evaluate its diagnostic ability in congenital heart disease, we sought to apply iNAV to dual-phase sequencing. METHODS: Healthy volunteers and patients with congenital heart disease underwent dual-phase imaging using the conventional diaphragmatic-navigation (dNAV) and iNAV. Acquisition time was recorded and image quality assessed. Sharpness and length of the right coronary (RCA), left anterior descending (LAD), and circumflex (LCx) arteries were measured in both cardiac phases for both approaches. Qualitative and quantitative analyses were performed in a blinded and randomized fashion. RESULTS: In volunteers, there was no significant difference in vessel sharpness between approaches (p > 0.05). In patients, analysis showed equal vessel sharpness for LAD and RCA (p > 0.05). LCx sharpness was greater with dNAV (p < 0.05). Visualized length with iNAV was 0.5 ± 0.4 cm greater than that with dNAV for LCx in diastole (p < 0.05), 1.0 ± 0.3 cm greater than dNAV for LAD in diastole (p < 0.05), and 0.8 ± 0.7 cm greater than dNAV for RCA in systole (p < 0.05). Qualitative scores were similar between modalities (p = 0.71). Mean iNAV scan time was 5:18 ± 2:12 min shorter than mean dNAV scan time in volunteers (p = 0.0001) and 3:16 ± 1:12 min shorter in patients (p = 0.0001). CONCLUSIONS: Image quality of iNAV and dNAV was similar with better distal vessel visualization with iNAV. iNAV acquisition time was significantly shorter. Complete cardiac diagnosis was achieved. Shortened acquisition time will improve clinical applicability and patient comfort.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Distribuição Aleatória
16.
Magn Reson Med ; 77(5): 1894-1908, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27221073

RESUMO

PURPOSE: To develop a respiratory motion correction framework to accelerate free-breathing three-dimensional (3D) whole-heart coronary lumen and coronary vessel wall MRI. METHODS: We developed a 3D flow-independent approach for vessel wall imaging based on the subtraction of data with and without T2-preparation prepulses acquired interleaved with image navigators. The proposed method corrects both datasets to the same respiratory position using beat-to-beat translation and bin-to-bin nonrigid corrections, producing coregistered, motion-corrected coronary lumen and coronary vessel wall images. The proposed method was studied in 10 healthy subjects and was compared with beat-to-beat translational correction (TC) and no motion correction for the left and right coronary arteries. Additionally, the coronary lumen images were compared with a 6-mm diaphragmatic navigator gated and tracked scan. RESULTS: No significant differences (P > 0.01) were found between the proposed method and the gated and tracked scan for coronary lumen, despite an average improvement in scan efficiency to 96% from 59%. Significant differences (P < 0.01) were found in right coronary artery vessel wall thickness, right coronary artery vessel wall sharpness, and vessel wall visual score between the proposed method and TC. CONCLUSION: The feasibility of a highly efficient motion correction framework for simultaneous whole-heart coronary lumen and vessel wall has been demonstrated. Magn Reson Med 77:1894-1908, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Vasos Coronários/diagnóstico por imagem , Coração/diagnóstico por imagem , Imageamento Tridimensional/métodos , Algoritmos , Endotélio Vascular/diagnóstico por imagem , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Angiografia por Ressonância Magnética/métodos , Masculino , Movimento (Física) , Respiração , Técnicas de Imagem de Sincronização Respiratória/métodos
17.
J Magn Reson Imaging ; 46(1): 218-227, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28152227

RESUMO

PURPOSE: To propose a 3D quantitative high-resolution T1 mapping technique, called 3D SASHA (saturation-recovery single-shot acquisition), which combines a saturation recovery pulse with 1D-navigator-based-respiratory motion compensation to acquire the whole volume of the heart in free breathing. The sequence was tested and validated both in a T1 phantom and in healthy subjects. MATERIALS AND METHODS: The 3D SASHA method was implemented on a 1.5T scanner. A diaphragmatic navigator was used to allow free-breathing acquisition and the images were acquired with a resolution of 1.4 × 1.4 × 8 mm3 . For assessment of accuracy and precision the sequence was compared with the reference gold-standard inversion-recovery spin echo (IRSE) pulse sequence in a T1 phantom, while for the in vivo studies (10 healthy volunteers) 3D SASHA was compared with the clinically used 2D MOLLI (3-3-5) and 2D SASHA protocols. RESULTS: There was good agreement between the T1 values measured in a T1 phantom with 3D SASHA and the reference IRSE pulse sequences (1111.6 ± 31 msec vs. 1123.6 ± 8 msec, P = 0.9947). Mean and standard deviation of the myocardial T1 values in healthy subjects measured with 2D MOLLI, 2D SASHA, and 3D SASHA sequences were 881 ± 40 msec, 1181.3 ± 32 msec, and 1153.6 ± 28 msec respectively. CONCLUSION: The proposed 3D SASHA sequence allows for high-resolution free-breathing whole-heart T1 -mapping with T1 values in good agreement with the 2D SASHA and improved precision. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:218-227.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Ventrículos do Coração/anatomia & histologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imagem Cinética por Ressonância Magnética/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Processamento de Sinais Assistido por Computador , Adulto , Algoritmos , Técnicas de Imagem Cardíaca/instrumentação , Feminino , Humanos , Aumento da Imagem/métodos , Imagem Cinética por Ressonância Magnética/instrumentação , Masculino , Modelos Biológicos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
J Magn Reson Imaging ; 45(6): 1675-1683, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27801994

RESUMO

PURPOSE: To assess the diagnostic value of three-dimensional late enhancement (3D-LGE) for the detection of myocardial necrosis in a routine clinical setting. 3D-LGE has been proposed as a novel magnetic resonance (MR) technique for the accurate detection of myocardial scar in both the ventricles and atria. Its performance in clinical practice has been poorly examined. MATERIALS AND METHODS: Fifty-seven patients referred for cardiac MR examination including scar imaging were prospectively enrolled. Gadolinium enhanced single breathhold 3D T1-weighted gradient-echo inversion recovery sequence and a conventional 2D-LGE sequence were performed using a 1.5 Tesla clinical MR imaging system. The presence, pattern and transmurality of LGE, diagnostic accuracy and level of diagnostic confidence as well as image quality (median quality, mean LGE signal intensity, sharpness, virtual scan time) were graded on a 4-point scale. RESULTS: Interpretable images were obtained in 52/57 2D-LGE and in 47/57 3D high-resolution exams. LGE was detected in 10 patients with ischemic pattern, 9 with nonischemic pattern, while it was absent in 28, resulting in a total of 47 complete datasets. The detection of global and segmental LGE as well as its transmural extent were similar for both techniques (P = 0.65, P = 0.305, and P = 0.15, respectively). Image quality (median quality, LGE/ myocardial and LGE/ blood pool sharpness) was similar for both techniques (P = 0.740, P = 0.34, and P = 1.00, respectively), but LGE signal intensity was higher with 2D (P = 0.020). CONCLUSION: 3D-LGE diagnostic and quality scores were comparable to 2D-LGE in a routine clinical setting. Further technical refinement is required for 3D LGE to offer a reliable alternative for high quality scar imaging. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;45:1675-1683.


Assuntos
Algoritmos , Meios de Contraste/administração & dosagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Isquemia Miocárdica/diagnóstico por imagem , Miocárdio Atordoado/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Isquemia Miocárdica/patologia , Miocárdio Atordoado/etiologia , Miocárdio Atordoado/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
19.
J Cardiovasc Magn Reson ; 19(1): 68, 2017 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-28893296

RESUMO

BACKGROUND: The use of coronary MR angiography (CMRA) in patients with coronary artery disease (CAD) remains limited due to the long scan times, unpredictable and often non-diagnostic image quality secondary to respiratory motion artifacts. The purpose of this study was to evaluate CMRA with image-based respiratory navigation (iNAV CMRA) and compare it to gold standard invasive x-ray coronary angiography in patients with CAD. METHODS: Consecutive patients referred for CMR assessment were included to undergo iNAV CMRA on a 1.5 T scanner. Coronary vessel sharpness and a visual score were assigned to the coronary arteries. A diagnostic reading was performed on the iNAV CMRA data, where a lumen narrowing >50% was considered diseased. This was compared to invasive x-ray findings. RESULTS: Image-navigated CMRA was performed in 31 patients (77% male, 56 ± 14 years). The iNAV CMRA scan time was 7 min:21 s ± 0 min:28 s. Out of a possible 279 coronary segments, 26 segments were excluded from analysis due to stents or diameter less than 1.5 mm, resulting in a total of 253 coronary segments. Diagnostic image quality was obtained for 98% of proximal coronary segments, 94% of middle segments, and 91% of distal coronary segments. The sensitivity and specificity was 86% and 83% per patient, 80% and 92% per vessel and 73% and 95% per segment. CONCLUSION: In this study, iNAV CMRA offered a very good diagnostic performance when compared against invasive x-ray angiography. Due to the short and predictable scan time it can add clinical value as a part of a comprehensive CAD assessment protocol.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Angiografia por Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Adulto , Idoso , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
20.
J Cardiovasc Magn Reson ; 19(1): 97, 2017 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-29202776

RESUMO

BACKGROUND: Image-navigated 3-dimensional late gadolinium enhancement (iNAV-3D LGE) is an advanced imaging technique that allows for direct respiratory motion correction of the heart. Its feasibility in a routine clinical setting has not been validated. METHODS: Twenty-three consecutive patients referred for cardiovascular magnetic resonance (CMR) examination including late gadolinium enhancement (LGE) imaging were prospectively enrolled. Image-navigated free-breathing 3-dimensional (3D) T1-weighted gradient-echo LGE and two-dimensional (2D LGE) images were acquired in random order on a 1.5 T CMR system. Images were assessed for global, segmental LGE detection and transmural extent. Objective image quality including signal-to-noise (SNR), contrast-to-noise (CNR) and myocardial/blood sharpness were performed. RESULTS: Interpretable images were obtained in all 2D-LGE and in 22/23 iNAV-3D LGE exams, resulting in a total of 22 datasets and 352 segments. LGE was detected in 5 patients with ischemic pattern, in 7 with non-ischemic pattern, while it was absent in 10 cases. There was an excellent agreement between 2D and 3D data sets with regard to global, segmental LGE detection and transmurality. Blood-myocardium sharpness measurements were also comparable between the two techniques. SNRblood and CNRblood-myo was significantly higher for 2D LGE (P < 0.001, respectively), while SNRmyo was not statistically significant between 2D LGE and iNAV-3D LGE. CONCLUSION: Diagnostic performance of iNAV-3D LGE was comparable to 2D LGE in a prospective clinical setting. SNRblood and CNRblood-myo was significantly lower in the iNAV-3D LGE group.


Assuntos
Meios de Contraste/administração & dosagem , Cardiopatias/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/patologia , Compostos Organometálicos/administração & dosagem , Estudos de Viabilidade , Cardiopatias/patologia , Cardiopatias/fisiopatologia , Humanos , Necrose , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa