Resultados 1 - 20 de 62
Filtrar
1.
Acta Radiol ; 65(6): 654-662, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38623647

RESUMO

BACKGROUND: Post-contrast T1-Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions (SPACE) is the preferred 3D T1 spin-echo sequence for evaluating brain metastases, regardless of the prolonged scan time. PURPOSE: To evaluate the application of accelerated post-contrast T1-SPACE with iterative denoising (ID) for intracranial enhancing lesions in oncologic patients. MATERIAL AND METHODS: For evaluation of intracranial lesions, 108 patients underwent standard and accelerated T1-SPACE during the same imaging session. Two neuroradiologists evaluated the overall image quality, artifacts, degree of enhancement, mean contrast-to-noise ratiolesion/parenchyma, and number of enhancing lesions for standard and accelerated T1-SPACE without ID. RESULTS: Although there was a significant difference in the overall image quality and mean contrast-to-noise ratiolesion/parenchyma between standard and accelerated T1-SPACE without ID and accelerated SPACE with and without ID, there was no significant difference between standard and accelerated T1-SPACE with ID. Accelerated T1-SPACE showed more artifacts than standard T1-SPACE; however, accelerated T1-SPACE with ID showed significantly fewer artifacts than accelerated T1-SPACE without ID. Accelerated T1-SPACE without ID showed a significantly lower number of enhancing lesions than standard- and accelerated T1-SPACE with ID; however, there was no significant difference between standard and accelerated T1-SPACE with ID, regardless of lesion size. CONCLUSION: Although accelerated T1-SPACE markedly decreased the scan time, it showed lower overall image quality and lesion detectability than the standard T1-SPACE. Application of ID to accelerated T1-SPACE resulted in comparable overall image quality and detection of enhancing lesions in brain parenchyma as standard T1-SPACE. Accelerated T1-SPACE with ID may be a promising replacement for standard T1-SPACE.


Assuntos
Artefatos , Neoplasias Encefálicas , Meios de Contraste , Estudos de Viabilidade , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Humanos , Neoplasias Encefálicas/diagnóstico por imagem , Feminino , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Idoso , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Adulto , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Razão Sinal-Ruído , Idoso de 80 Anos ou mais , Aumento da Imagem/métodos
2.
Medicina (Kaunas) ; 60(5)2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38792912

RESUMO

Background and Objectives: No comparative study has evaluated the inter-method agreement and reliability between Heuron AD and other clinically available brain volumetric software packages. Hence, we aimed to investigate the inter-method agreement and reliability of three clinically available brain volumetric software packages: FreeSurfer (FS), NeuroQuant® (NQ), and Heuron AD (HAD). Materials and Methods: In this study, we retrospectively included 78 patients who underwent conventional three-dimensional (3D) T1-weighed imaging (T1WI) to evaluate their memory impairment, including 21 with normal objective cognitive function, 24 with mild cognitive impairment, and 33 with Alzheimer's disease (AD). All 3D T1WI scans were analyzed using three different volumetric software packages. Repeated-measures analysis of variance, intraclass correlation coefficient, effect size measurements, and Bland-Altman analysis were used to evaluate the inter-method agreement and reliability. Results: The measured volumes demonstrated substantial to almost perfect agreement for most brain regions bilaterally, except for the bilateral globi pallidi. However, the volumes measured using the three software packages showed significant mean differences for most brain regions, with consistent systematic biases and wide limits of agreement in the Bland-Altman analyses. The pallidum showed the largest effect size in the comparisons between NQ and FS (5.20-6.93) and between NQ and HAD (2.01-6.17), while the cortical gray matter showed the largest effect size in the comparisons between FS and HAD (0.79-1.91). These differences and variations between the software packages were also observed in the subset analyses of 45 patients without AD and 33 patients with AD. Conclusions: Despite their favorable reliability, the software-based brain volume measurements showed significant differences and systematic biases in most regions. Thus, these volumetric measurements should be interpreted based on the type of volumetric software used, particularly for smaller structures. Moreover, users should consider the replaceability-related limitations when using these packages in real-world practice.


Assuntos
Encéfalo , Software , Humanos , Masculino , Feminino , Reprodutibilidade dos Testes , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Doença de Alzheimer/diagnóstico por imagem , Disfunção Cognitiva/diagnóstico , Imageamento por Ressonância Magnética/métodos , Idoso de 80 Anos ou mais
3.
Acta Radiol ; 64(7): 2245-2252, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36575592

RESUMO

BACKGROUND: Computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) is highly affected by respiratory motion; however, respiratory motion of target nodule during the PTNB and its effect on CT-guided lung biopsy have not been studied. PURPOSE: To investigate the effect of the respiratory motion of pulmonary nodules on CT-guided PTNB. MATERIAL AND METHODS: We retrospectively reviewed the procedural CT scans of 426 pulmonary nodules that underwent PTNB during quiet breathing. Maximal and average respiratory motions were measured using the difference of table position of the targeted nodule between multiple procedural scans. Diagnostic performance, complications, and technical factors of PTNB in nodules with large motion (maximal motion >1 cm) were compared with those in nodules with small motion (≤1 cm). RESULTS: The mean maximal and average respiratory motions between tidal volume breathing were 5.4 ± 4.4 and 2.7 ± 2.6 mm, respectively. Sensitivity and accuracy were 93.1% and 96.1% in nodules with large motion, compared with 94.7% and 95.9% in nodules with small motion, respectively. Respiratory targeting (P < 0.001), needle modulation (P < 0.001), motion artifact of target (P < 0.001), target disappearance from scans (P < 0.001), and number of performed CT scans (P < 0.001) were significantly higher in the large motion group, with no significant difference in radiation dose and complications between the groups. CONCLUSION: The respiratory motion of pulmonary nodules during CT-guided PTNB may cause technical difficulties but does not affect diagnostic performance nor complications associated with PTNB.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Humanos , Neoplasias Pulmonares/patologia , Estudos Retrospectivos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Biópsia por Agulha/métodos , Biópsia Guiada por Imagem/métodos , Radiografia Intervencionista/métodos
4.
AJR Am J Roentgenol ; 218(6): 1062-1073, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34985311

RESUMO

BACKGROUND. Isotropic 3D T1-weighted imaging has long acquisition times, potentially leading to motion artifact and altered brain volume measurements. Acquisition times may be greatly shortened using an isotropic ultrafast 3D echo-planar imaging (EPI) T1-weighted sequence. OBJECTIVE. The purpose of this article was to compare automated brain volume measurements between conventional 3D T1-weighted imaging and ultrafast 3D EPI T1-weighted imaging. METHODS. This retrospective study included 36 patients (25 women, 11 men; mean age, 68.4 years) with memory impairment who underwent 3-T brain MRI. Examinations included both conventional 3D T1-weighted imaging using inversion recovery gradient-recalled echo sequence (section thickness, 1.0 mm; acquisition time, 3 minutes 4 seconds) and, in patients exhibiting motion, an isotropic ultrafast 3D EPI T1-weighted sequence (section thickness, 1.2 mm; acquisition time, 30 seconds). The 36-patient sample excluded five patients in whom severe motion artifact rendered the conventional sequence of insufficient quality for volume measurements. Automated brain volumetry was performed using NeuroQuant (version 3.0, CorTechs Laboratories) and FreeSurfer (version 7.1.1, Harvard University) software. Volume measurements were compared between sequences for nine regions in each hemisphere. RESULTS. Volumes showed substantial to almost perfect agreement between the two sequences for most regions bilaterally. However, most regions showed significant mean differences between sequences, and Bland-Altman analyses showed consistent systematic biases and wide limits of agreement (LOA). For example, for the left hemisphere using NeuroQuant, volume was significantly greater for the ultrafast sequence in four regions and significantly greater for the conventional sequence in three regions, whereas standardized effect size between sequences was moderate for four regions and large for one region. Using NeuroQuant, mean bias (ultrafast minus conventional) and 95% LOA were greatest in cortical gray matter bilaterally (-50.61 cm3 [-56.27 cm3, -44.94 cm3] for the left hemisphere; -50.02 cm3 [-54.88 cm3, -45.16 cm3] for the right hemisphere). The variation between the two sequences was observed in subset analyses of 16 patients with and 20 patients without Alzheimer disease. CONCLUSION. Brain volume measurements show significant differences and systematic biases between the conventional and ultrafast sequences. CLINICAL IMPACT. In patients in whom severe motion artifact precludes use of the conventional sequence, the ultrafast sequence may be useful to enable brain volume-try. However, the current conventional 3D T1-weighted sequence remains preferred in patients who can tolerate the standard examination.


Assuntos
Imagem Ecoplanar , Imageamento por Ressonância Magnética , Idoso , Encéfalo/diagnóstico por imagem , Imagem Ecoplanar/métodos , Feminino , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software
5.
J Comput Assist Tomogr ; 46(2): 294-299, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35297585

RESUMO

OBJECTIVE: The aim of the study was to retrospectively evaluate the safety and accuracy of computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) of lung lesions during quiet breathing. METHODS: We investigated the diagnostic performance and complication rate of 585 procedures in 563 patients (357 men; mean age, 67.7 years), who underwent CT-guided PTNBs during quiet breathing, aided by a respiratory targeting technique from May 2017 to July 2019. Differences between the cases with and without respiratory targeting were analyzed. Logistic regression analyses were performed to examine the development of pneumothorax and hemoptysis. RESULTS: Percutaneous transthoracic needle biopsy samples were successfully obtained in 574 of 585 procedures (98.1%). Final diagnoses included: 410 malignant cases, 119 benign cases, and 45 indeterminate cases. The sensitivity, specificity, and accuracy of diagnosis were 94.4%, 100%, and 95.7%, respectively. Use of respiratory targeting was associated with younger age (P = 0.004), smaller lesion size (P < 0.001), peripheral location (P = 0.003), shorter distance from the diaphragm (P < 0.001), lower lobe location (P < 0.001), prone position (P = 0.004), and visible motion artifact (P < 0.001). Pneumothorax and hemoptysis rates were 22.9% and 7.9%, respectively. Upon multivariate analysis, emphysema (P = 0.002) was the only independent risk factor for pneumothorax, whereas distance from the pleura greater than 2 cm (P < 0.001), tissue sampling 3 times or more (P = 0.003), and a less experienced operator (P < 0.001) were risk factors for hemoptysis. CONCLUSIONS: Computed tomography-guided PTNB during quiet breathing with respiratory targeting yielded high diagnostic performance with a slightly higher rate of complications. Free-breathing PTNB can be applied in clinical practice, based on lesion location and risk factors for complications.


Assuntos
Biópsia Guiada por Imagem , Neoplasias Pulmonares , Radiografia Intervencionista , Idoso , Humanos , Biópsia Guiada por Imagem/métodos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
6.
Acta Radiol ; 62(9): 1193-1199, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32867507

RESUMO

BACKGROUND: Although time-of-flight magnetic resonance angiography (TOF-MRA) is widely used, it has limited usefulness for follow-up after stent-assisted coil embolization. Contrast-enhanced MRA (CE-MRA) and ultrashort echo time MRA have been suggested as alternative methods for visualization after this procedure. PURPOSE: To compare efficacy and usefulness of pointwise encoding time reduction with radial acquisition (PETRA) sequence in subtraction-based MRA (qMRA), TOF-MRA, and CE-MRA during the follow-up after Neuroform Atlas stent-assisted coil embolization for intracranial aneurysms. MATERIAL AND METHODS: This retrospective study included 23 patients with 24 aneurysms who underwent Neuroform Atlas stent-assisted coil embolization for intracranial aneurysms. All patients were evaluated with PETRA qMRA, TOF-MRA, and CE-MRA at the same follow-up session. The flow within stents, occlusion status, and presence of pseudo-stenosis were evaluated; inter-observer and intermodality agreements for the three methods were also graded. RESULTS: The mean score for flow visualization within the stents was significantly higher for PETRA qMRA and CE-MRA than for TOF-MRA (although no significant difference was found between PETRA qMRA and CE-MRA). Good inter-observer agreement was observed for each modality. PETRA qMRA and CE-MRA were more consistent with digital subtraction angiography (DSA) than TOF-MRA for aneurysm occlusion status. The intermodality agreement was better between PETRA qMRA and DSA, and between CE-MRA and DSA, than between DSA and TOF-MRA. Pseudo-stenosis was most frequently observed in TOF-MRA, followed by CE-MRA and PETRA qMRA. CONCLUSION: PETRA qMRA is useful for evaluating the parent artery patency and occlusion status of aneurysms after Neuroform Atlas stent-assisted coil embolization.


Assuntos
Angiografia Digital/métodos , Angiografia Cerebral/métodos , Embolização Terapêutica/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Angiografia por Ressonância Magnética/métodos , Stents , Adulto , Idoso , Meios de Contraste , Feminino , Seguimentos , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tempo , Resultado do Tratamento
7.
Neuroradiology ; 62(6): 723-731, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32055943

RESUMO

PURPOSE: Acute vertebrobasilar occlusion (VBO) has a grave clinical course; however, thrombectomy in VBO patients has rarely been reported. We retrospectively evaluated the clinical and radiological outcomes of thrombectomy in VBO patients. METHODS: From March 2010 to December 2017, 38 patients with 40 acute VBOs underwent thrombectomy at our hospital. Thrombectomy was performed using catheter aspiration (n = 11, 26.8%) or a stent retriever (n = 29, 70.7%). RESULTS: Good clinical outcomes (3-month modified Rankin scale (mRS) of 2 or lower) were achieved in 9 cases (22.5%), and successful recanalization (thrombolysis in cerebral infarction (TICI) grade of 2b or 3) was achieved in 35 cases (87.5%). Good clinical outcomes were significantly related to aetiologies other than atherosclerosis (p = 0.020) and lower National Institutes of Health Stroke Scale (NIHSS) scores on admission (p = 0.025). The clinical and radiological outcomes did not differ significantly between catheter aspiration and stent retriever thrombectomy (p = 1.000 and p = 0.603, respectively); however, stent retriever thrombectomy had a shorter procedure time than catheter aspiration (59.7 ± 31.2 vs. 84.5 ± 35.1 min, p = 0.037). CONCLUSION: In our series, good clinical outcomes were associated with a lower NIHSS score on admission and stroke aetiologies other than atherosclerosis. The two thrombectomy modalities showed similar clinical and radiological outcomes. However, stent retrievers seemed to allow more rapid recanalization than catheter aspiration in VBO.


Assuntos
Trombectomia/métodos , Insuficiência Vertebrobasilar/diagnóstico por imagem , Insuficiência Vertebrobasilar/cirurgia , Idoso , Feminino , Humanos , Masculino , Estudos Retrospectivos
8.
Br J Neurosurg ; 34(3): 333-338, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31650871

RESUMO

Purpose: The Neuroform Atlas is a self-expandable and low-profiled stent that is used for aneurysm neck scaffolding and has been recently approved for clinical practice in Korea. We present our initial experiences of endovascular coiling using the Neuroform Atlas stent.Materials and methods: All cerebral aneurysms treated by stent-assisted coiling with a Neuroform atlas stent in two institutions between February and May 2018 were retrospectively evaluated. Fifty-one patients with 55 un-ruptured saccular cerebral aneurysms (mean size: 4.72 ± 1.81 mm, mean neck diameter: 3.82 ± 1.23 mm, mean dome-to-neck ratio: 1.21) were included in our study (40 females, mean age: 59.29 ± 11.96 years). Patient demographics, aneurysm characteristics, initial angiographic post procedural outcomes, and clinical and angiographic follow-up data were analysed.Results: There was one case of procedural failure due to a downward slip during stent deployment. The technical success rate was 98.2% (54/55). A post-procedure control angiogram showed complete occlusion in 27 (50%), residual neck in 16 (29.6%) and residual sac in 11 (20.4%) aneurysms. There were no procedure-related complications. In one case, a symptomatic thromboembolism with left hand grip weakness (grade IV) was observed two days after the procedure and resolved at discharge. The modified Rankin scale score at discharge was 0 in all patients. Angiographic follow-up data at a mean of 4.8 months were available for 51/54 (94.4%) aneurysms. Among them, 27 aneurysms (52.9%) were stable, 20 aneurysms (39.2%) showed progressive occlusion and 4 aneurysms showed an increased modified Raymond Roy occlusion classification score (only one of these patients was included in the recanalization criteria).Conclusion: Our findings suggest the Neuroform Atlas stent can be useful for the coiling of cerebral aneurysms without significant complications regardless of aneurysm location.


Assuntos
Aneurisma Intracraniano , Stents , Idoso , Angiografia Cerebral , Embolização Terapêutica , Feminino , Força da Mão , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , República da Coreia , Estudos Retrospectivos , Resultado do Tratamento
9.
J Neuroradiol ; 47(2): 151-160, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30951770

RESUMO

BACKGROUND AND PURPOSE: We investigated the clinical feasibility of synthetic MRI with a 4-min single scan using a 48-channel head coil as a routine neuroimaging protocol in daily practice by assessing its diagnostic image quality. METHODS: We retrospectively reviewed the imaging data of 89 patients who underwent routine brain MRI using synthetic MRI acquisition between February 2017 and April 2017. Image quality assessments were performed by two independent readers on synthetic T1 fluid-attenuated inversion recovery (FLAIR), T2-weighted, T2 FLAIR, and phase-sensitive inversion recovery sequences acquired using multiple-dynamic multiple-echo imaging. Interobserver reliability between the two readers was assessed using kappa (κ) statistics. RESULTS: On a 4-point assessment scale, the overall image quality and anatomical delineation provided by synthetic brain MRI were found to be good with scores of more than 3 points for all sequences except for the T2 FLAIR sequence. The synthetic T2 FLAIR sequence provided sufficient image quality but showed more pronounced artifacts, especially the CSF pulsation artifact and linear hyperintensity along the brain surface. Interobserver agreement for evaluating image quality of all synthetic sequences was good to excellent (κ, 0.61-0.99; P < 0.001). CONCLUSION: Synthetic MRI can be acceptable as a routine clinical neuroimaging protocol with a short scan time. It can be helpful to design customized and flexible neuroimaging protocols for each institution.


Assuntos
Encéfalo/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Aumento da Imagem/métodos , Lactente , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
10.
Neuroradiology ; 61(7): 747-755, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30684114

RESUMO

PURPOSE: To evaluate the diagnostic performance, image quality, artifacts, and radiation doses of virtual non-contrast (VNC) images, relative to true non-contrast (TNC) images, in patients with surgically clipped aneurysms. METHODS: Seventy-six patients who underwent unenhanced computed tomography (CT) and dual-energy (DE)-CT angiography after surgical clipping of 85 intracranial aneurysms were included in the study. Diagnostic performances of VNC and TNC images were compared with respect to sensitivity, specificity, and positive and negative predictive values. The results of quantitative and qualitative analyses were compared between VNC and TNC images. Radiation doses were also compared between VNC and TNC images. RESULTS: Diagnostic performance of VNC images was lower than that of TNC images; however, addition of contrast-enhanced images improved diagnostic performance. Image noise and mean attenuation of VNC images were significantly higher than those of TNC images in the centrum semiovale, cerebellum, and pons. The quality of VNC images was excellent or sufficient (85.5% for observer 1, 85.5% for observer 2), and complete acceptance of VNC images was achieved in 64.5% for observer 1 and in 71.0% for observer 2; however, the addition of contrast-enhanced images increased the level of acceptance (92.0% for observer 1, 90.9% for observer 2). Clip artifacts were significantly lower in VNC images than in TNC images. CT dose index, dose-length product, and effective dose were significantly lower without TNC images. CONCLUSION: VNC images showed lower diagnostic performance and image quality, and higher image noise than TNC images; however, VNC images could reduce clip artifacts and radiation doses.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Meios de Contraste , Feminino , Humanos , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
11.
Medicina (Kaunas) ; 56(1)2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31906183

RESUMO

Background and Objectives: To investigate the diagnostic performance of F-18 fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) and subsequent ultrasonography (US) for determining cervical nodal metastasis in oncology patients. Materials and Methods: Fifty-nine cervical lymph nodes (LNs) initially detected by PET/CT with subsequent neck US were included in this retrospective study. All LNs were subjected to US-guided fine-needle aspiration or core needle biopsy. The maximum standardized uptake value (SUVmax) and sonographic features were assessed. Results: Forty-three of 59 cervical LNs detected by PET/CT were malignant. PET/CT alone showed a highest diagnostic value for metastatic LNs with 81.4% sensitivity, 68.8% specificity, and 78% accuracy when SUVmax ≥5.8 was applied as an optimal cut-off value. Combined PET/CT and subsequent US diagnoses for determining nodal metastasis showed the following diagnostic performance: 81.4% sensitivity, 87.5% specificity, and 83.1% accuracy. There was a significant difference in the diagnostic performance between the two diagnostic imaging approaches (p = 0.006). Conclusions: Combined diagnosis using subsequent US showed a significantly higher diagnostic performance for determining nodal metastasis in the neck. Therefore, we believe that our proposed diagnostic strategy using subsequent US can be helpful in evaluating cervical LNs on PET/CT. Moreover, our results clarify the need for US-guided tissue sampling in oncology patients.


Assuntos
Linfonodos/diagnóstico por imagem , Metástase Linfática/diagnóstico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Linfonodos/fisiopatologia , Metástase Linfática/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Pescoço/diagnóstico por imagem , Pescoço/fisiopatologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Retrospectivos , Ultrassonografia/métodos
12.
BMC Med Imaging ; 18(1): 12, 2018 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-29764382

RESUMO

BACKGROUND: This study aimed to assess the appropriate number of sessions and interval of routine follow-up ultrasonography (US) in patients who underwent total thyroidectomy for papillary thyroid carcinoma (PTC). METHODS: Between January 2008 and December 2009, 569 patients underwent total thyroidectomy for PTC. Of the 569 patients, 44 were excluded from the study because of no US follow-up data for the neck (n = 43) or owing to indeterminate tumor recurrence/persistence (n = 1). The follow-up US for all the patients was performed by a single radiologist. Based on the cytohistopathological results, tumor recurrence/persistence was determined. RESULTS: In the 525 patients, the mean interval to the last follow-up US was 54.7 months, and the mean number of follow-up US sessions was 4.4. Of the 525 patients, 31 (5.9%) showed nodal (n = 30) and non-nodal (n = 1) tumor recurrence/persistence. Patient age and N stage were independently associated with tumor recurrence/persistence. Among patients showing tumor recurrence/persistence after total thyroidectomy, the time at first detection of suspicious US findings on follow-up US was ≤8 months in 2 patients, between 10 and 23 months in 21, and ≥ 25 months in 8. In a receiver operating characteristic curve analysis, the number of sessions and interval of the provided follow-up US were inappropriate for the detection of tumor recurrence/persistence. CONCLUSIONS: For the detection of tumor recurrence/persistence after total thyroidectomy in PTC patients, routine US follow-up with a 1- or 2-year interval may be excessive.


Assuntos
Recidiva Local de Neoplasia/diagnóstico por imagem , Câncer Papilífero da Tireoide/diagnóstico por imagem , Câncer Papilífero da Tireoide/cirurgia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Testes Diagnósticos de Rotina , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/epidemiologia , Curva ROC , Câncer Papilífero da Tireoide/epidemiologia , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/cirurgia , Neoplasias da Glândula Tireoide/epidemiologia , Tireoidectomia , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia , Adulto Jovem
13.
Acta Neurochir (Wien) ; 160(12): 2411-2418, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30350184

RESUMO

BACKGROUND: Proximal middle cerebral artery (M1 segment) aneurysms are relatively deeply located in neighboring lenticulostriate arteries, which make them unsuitable for microsurgery. We aimed to investigate the clinical and radiological outcomes of endovascular coiling of M1 segment aneurysms. METHODS: Between January 2003 and December 2014, we retrospectively reviewed the medical records of 52 patients (52 aneurysms) from four institutions who underwent endovascular coiling of M1 segment aneurysms. Patients who underwent clinical and radiologic follow-up for more than a year after the procedure were evaluated. RESULTS: The aneurysms were located in the early frontal branch, early temporal branch, and lenticulostriate artery in 28, 15, and nine patients, respectively. Endovascular coiling was achieved in 51 cases and failed in one case. Of these 51 cases, 46 (90.2%) and five (9.8%) were non-ruptured and ruptured aneurysms, respectively. Initial angiographic results revealed complete occlusion in 26 (51.0%), residual neck in 16 (31.4%), and residual sac in nine (17.6%) cases. One failed case had a symptomatic procedural complication of thromboembolism. However, there was no permanent morbidity or mortality. Two major recanalization cases (3.9%) were retreated by endovascular coiling. On multivariable logistic regression analysis, aneurysmal recurrence was significantly related to aneurysm height (OR, 1.887; 95% CI, 1.107 to 3.217; p = 0.020), width (OR, 1.836; CI, 1.127 to 2.992; p = 0.015), and neck (OR, 4.017; CI, 1.220 to 13.232, p = 0.022). CONCLUSION: Endovascular coiling of M1 segment aneurysms appeared to be a feasible treatment option with a relatively low-retreatment rate. Aneurysm size was statistically significantly associated with recurrence.


Assuntos
Aneurisma Roto/cirurgia , Procedimentos Endovasculares/efeitos adversos , Aneurisma Intracraniano/cirurgia , Artéria Cerebral Média/cirurgia , Complicações Pós-Operatórias/epidemiologia , Adulto , Idoso , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Stents/efeitos adversos
14.
Surg Radiol Anat ; 40(7): 811-813, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29667029

RESUMO

Congenital absence of the internal carotid artery (ICA) is rare, and patients with such a condition are often asymptomatic throughout their lifetime, because of sufficient collateral circulation. Collateral flow is provided via various channels; however, the role of persistent embryonic vessels under conditions in which the ICA is absent or occluded is unknown. We report a rare case of congenital absence of the left ICA and describe the collateral pathway consisting of a persistent trigeminal artery.


Assuntos
Artéria Carótida Interna/anormalidades , Variação Anatômica , Artéria Basilar/anormalidades , Circulação Colateral , Humanos , Imageamento Tridimensional , Angiografia por Ressonância Magnética , Masculino , Adulto Jovem
15.
Surg Radiol Anat ; 40(2): 237-240, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28988293

RESUMO

Persistent trigeminal artery (PTA) is a rare cerebrovascular variation of remnant fetal carotid-vertebrobasilar anastomoses. The PTA variant terminates in the cerebellar artery with no direct connection to the basilar artery. We present a rare case of a PTA variant that terminated directly into the ipsilateral posterior inferior cerebellar artery.


Assuntos
Cerebelo/irrigação sanguínea , Artérias Cerebrais/anormalidades , Aneurisma Intracraniano/diagnóstico por imagem , Acidentes de Trânsito , Angiografia Digital , Feminino , Humanos , Imageamento Tridimensional , Angiografia por Ressonância Magnética , Pessoa de Meia-Idade
16.
Eur Radiol ; 27(7): 3022-3032, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27858213

RESUMO

OBJECTIVES: To determine if gemistocytic grade II astrocytoma (GemA) and its MR imaging characteristics are associated with a shorter time-to-progression (TTP) compared with non-gemistocytic grade II astrocytoma (non-GemA). MATERIALS AND METHODS: We enrolled 78 patients who were followed up more than 5 years (29 pathologically proven GemA and 49 non-GemA) during a 10-year period. Contrast-enhanced T1-weighted, diffusion-weighted imaging (DWI), dynamic susceptibility contrast (DSC), and MR spectroscopy (MRS) and clinical data were retrospectively reviewed. Clinical and MR imaging features were analyzed as possible prognostic factors of high-grade transformation, and multivariate analysis of TTP was performed using Cox proportional modeling. RESULTS: GemA showed more frequent high-grade features than non-GemA, including diffusion restriction (P < .001), increased choline/creatine (P = .02), and increased choline/NAA ratio (P = .015). Patients with GemA had a significantly shorter median TTP (53.1 vs 68 months; P < .001). A gemistocytic histopathology (hazard ratio = 3.42; P = .015) and low ADC (hazard ratio = 3.61; P = .001) were independently associated with a shorter TTP. CONCLUSIONS: GemA can present with MR imaging findings mimicking high-grade glioma at initial diagnosis and transforms to high-grade disease earlier than non-GemA. Low ADC on DWI might be useful in stratifying the risk of progression in patients with grade II astrocytoma. KEY POINTS: • Gemistocytic grade II astrocytoma (GemA) showed more frequent high-grade features than non-GemA. • Patients with GemA had a significantly shorter median TTP than non-GemA. • Gemistocytic histopathology and low ADC were independently associated with shorter TTP.


Assuntos
Astrocitoma/patologia , Neoplasias Encefálicas/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Gradação de Tumores/métodos , Adulto , Idoso , Progressão da Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fatores de Tempo
17.
J Comput Assist Tomogr ; 41(6): 937-940, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28448414

RESUMO

OBJECTIVE: No previous studies have investigated thyroid calcification on computed tomography (CT) quantitatively by using Hounsfield unit (HU) values. This study aimed to analyze quantitative HU values of thyroid calcification on preoperative neck CT and to assess the characteristics of benign and malignant calcified thyroid nodules (CTNs). MATERIALS AND METHODS: Two hundred twenty patients who underwent neck CT before thyroid surgery from January 2015 to June 2016 were included. On soft-tissue window CT images, CTNs with calcified components of 3 mm or larger in minimum diameter were included in this study. The HU values and types of CTNs were determined and analyzed. RESULTS: Of 61 CTNs in 49 patients, there were 42 malignant nodules and 19 benign nodules. The mean largest diameter of the calcified component was 5.3 (2.5) mm (range, 3.1-17.1 mm). A statistically significant difference was observed in the HU values of calcified portions between benign and malignant CTNs, whereas there was no significant difference in patient age or sex or in the size, location, or type of each CTN. Of the 8 CTNs with pure calcification, 3 exhibited a honeycomb pattern on bone window CT images, and these 3 CTNs were all diagnosed as papillary thyroid carcinoma on histopathological examination. CONCLUSIONS: Hounsfield unit values of CTNs may be helpful for differentiating malignancy from benignity.


Assuntos
Calcinose/diagnóstico por imagem , Doenças da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Calcinose/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Doenças da Glândula Tireoide/complicações , Nódulo da Glândula Tireoide/complicações
18.
Neuroradiology ; 57(9): 929-35, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26156865

RESUMO

INTRODUCTION: Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is an accepted treatment for advanced Parkinson's disease (PD). However, targeting the STN is difficult due to its relatively small size and variable location. The purpose of this study was to assess which of the following sequences obtained with the 3.0 T MR system can accurately delineate the STN: coronal 3D fluid-attenuated inversion recovery (FLAIR), 2D T2*-weighted fast-field echo (T2*-FFE) and 2D T2-weighted turbo spin-echo (TSE) sequences. METHODS: We included 20 consecutive patients with PD who underwent 3.0 T MR for DBS targeting. 3D FLAIR, 2D T2*-FFE and T2-TSE images were obtained for all study patients. Image quality and demarcation of the STN were analysed using 4-point scales, and contrast ratio (CR) of the STN and normal white matter was calculated. The Friedman test was used to compare the three sequences. RESULTS: In qualitative analysis, the 2D T2*-FFE image showed more artefacts than 3D FLAIR or 2D T2-TSE, but the difference did not reach statistical significance. 3D FLAIR images showed significantly superior demarcation of the STN compared with 2D T2*-FFE and T2-TSE images (P < 0.001, respectively). The CR of 3D FLAIR was significantly higher than that of 2D T2*-FFE or T2-TSE images in multiple comparison correction (P < 0.001), but there was no significant difference in the CR between 2D T2*-FFE and T2-TSE images. CONCLUSION: Coronal 3D FLAIR images showed the most accurate demarcation of the STN for DBS targeting among coronal 3D FLAIR, 2D T2*-FFE and T2-TSE images.


Assuntos
Estimulação Encefálica Profunda , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Doença de Parkinson/cirurgia , Núcleo Subtalâmico/anatomia & histologia , Adulto , Idoso , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
20.
Neurointervention ; 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38615689

RESUMO

PURPOSE: In this study, we determined whether there were significant differences in procedure time, radiation dose, fluoroscopy time, and total contrast media dose when unruptured wideneck bifurcation aneurysms (WNBAs) were treated with the Woven EndoBridge (WEB) device and stent-assisted coil (SAC) embolization. MATERIALS AND METHODS: The WEB device and SAC embolization (14:17) were used to treat 31 cases of internal carotid artery bifurcation, anterior communicating artery, middle cerebral artery bifurcation, and basilar bifurcation aneurysms between August 2021 and December 2022. The procedure time, radiation dose, fluoroscopy time, and total contrast medium dose between the 2 treatment groups were compared and analyzed. In the WEB device group, the results between operators were compared, and the follow-up radiologic outcomes were investigated. RESULTS: The procedure and fluoroscopy times were significantly shorter in the WEB device group. Radiation and total contrast media dose were also significantly smaller in the WEB device, but there was no significant difference in results between operators. The follow-up radiological outcome showed adequate occlusion in 83.3% (10/12) of cases. CONCLUSION: The WEB device can be used as an alternative treatment method among the available endovascular treatment methods for WNBAs to reduce radiation exposure and the dose of contrast media when used adequately with appropriate indications.