BMC Musculoskelet Disord ; 25(1): 212, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38475756

RESUMO

BACKGROUND: In terms of the optics used for Knee arthroscopy, a large number of different endoscopes are currently available. However, the use of the 30° optics in knee arthroscopy has been established as the standard procedure for many years. As early as the 1990s, needle arthroscopy was occasionally used as a diagnostic tool. In addition to the development of conventional optics technology in terms of camera and resolution, needle arthroscopes are now available with chip-on-tip image sensor technology. To date, no study has compared the performance of this kind of needle arthroscopy versus standard arthroscopy in the clinical setting in terms of the visibility of anatomical landmarks. In this monocentric prospective feasibility study, our aim was to evaluate predefined anatomical landmarks of the knee joint using needle arthroscopy (0° optics) and conventional knee arthroscopy (30° optics) and compare their performance during knee surgery. METHODS: Examinations were performed on eight cadavers and seven patients who required elective knee arthroscopy. Two surgeons independently performed the examinations on these 15 knee joints, so that we were able to compare a total of 30 examinations. The focus was on the anatomical landmarks that could be visualized during a conventional diagnostic knee arthroscopy procedure. The quality of visibility was evaluated using a questionnaire. RESULTS: In summary, the average visibility for all the anatomic landmarks was rated 4.98/ 5 for the arthroscopy using 30° optics. For needle arthroscopy, an average score of 4.89/ 5 was obtained. Comparatively, the needle arthroscope showed slightly limited visibility of the retropatellar gliding surface in eight (4.5/ 5 vs. 5/ 5), medial rim of the patella in four (4.85/ 5 vs. 5/ 5), and suprapatellar recess in four (4.83/ 5 vs. 5/ 5) cases. Needle arthroscopy was slightly better at visualizing the posterior horn of the medial meniscus in four knee joints (4.9/ 5 vs. 4.85/ 5). CONCLUSION: Needle arthroscopy is a promising technology with advantages in terms of minimally invasive access and good visibility of anatomical landmarks. However, it also highlights some limitations, particularly in cases with challenging anatomy or the need for a wide field of view.


Assuntos
Artroscopia , Articulação do Joelho , Humanos , Artroscopia/métodos , Estudos Prospectivos , Estudos de Viabilidade , Articulação do Joelho/cirurgia , Artroscópios
2.
BMC Health Serv Res ; 23(1): 1313, 2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38017443

RESUMO

BACKGROUND: Due to the growing economic pressure, there is an increasing interest in the optimization of operational processes within surgical operating rooms (ORs). Surgical departments are frequently dealing with limited resources, complex processes with unexpected events as well as constantly changing conditions. In order to use available resources efficiently, existing workflows and processes have to be analyzed and optimized continuously. Structural and procedural changes without prior data-driven analyses may impair the performance of the OR team and the overall efficiency of the department. The aim of this study is to develop an adaptable software toolset for surgical workflow analysis and perioperative process optimization in arthroscopic surgery. METHODS: In this study, the perioperative processes of arthroscopic interventions have been recorded and analyzed subsequently. A total of 53 arthroscopic operations were recorded at a maximum care university hospital (UH) and 66 arthroscopic operations were acquired at a special outpatient clinic (OC). The recording includes regular perioperative processes (i.a. patient positioning, skin incision, application of wound dressing) and disruptive influences on these processes (e.g. telephone calls, missing or defective instruments, etc.). For this purpose, a software tool was developed ('s.w.an Suite Arthroscopic toolset'). Based on the data obtained, the processes of the maximum care provider and the special outpatient clinic have been analyzed in terms of performance measures (e.g. Closure-To-Incision-Time), efficiency (e.g. activity duration, OR resource utilization) as well as intra-process disturbances and then compared to one another. RESULTS: Despite many similar processes, the results revealed considerable differences in performance indices. The OC required significantly less time than UH for surgical preoperative (UH: 30:47 min, OC: 26:01 min) and postoperative phase (UH: 15:04 min, OC: 9:56 min) as well as changeover time (UH: 32:33 min, OC: 6:02 min). In addition, these phases result in the Closure-to-Incision-Time, which lasted longer at the UH (UH: 80:01 min, OC: 41:12 min). CONCLUSION: The perioperative process organization, team collaboration, and the avoidance of disruptive factors had a considerable influence on the progress of the surgeries. Furthermore, differences in terms of staffing and spatial capacities could be identified. Based on the acquired process data (such as the duration for different surgical steps or the number of interfering events) and the comparison of different arthroscopic departments, approaches for perioperative process optimization to decrease the time of work steps and reduce disruptive influences were identified.


Assuntos
Artroscopia , Salas Cirúrgicas , Humanos , Fluxo de Trabalho , Hospitais Universitários
3.
BMC Musculoskelet Disord ; 24(1): 790, 2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37798626

RESUMO

BACKGROUND: Glenoid bone loss is among the most important risk factors for recurrent anterior shoulder instability, and a bony reconstruction is recommended in cases of critical bone loss (> 15%). The commonly used surgical techniques, including coracoid transfer, are associated with considerable complications. The aim of this study was to assess the motion at the glenoid-bone-block interface after coracoid and spina-scapula bone-block reconstruction of the anterior glenoid. METHODS: Twelve cadaveric shoulders were tested. A 20% bone defect of the anterior glenoid was created, and the specimens were randomly assigned for glenoid augmentation using a coracoid bone block (n = 6) or a scapular spine bone block (n = 6). The glenoid-bone interface was cyclically loaded for 5000 cycles with a force of 170 N. The micromotion was tracked using an optical measurement system (GOM ARMIS) and was evaluated with the GOM Correlate Pro software. RESULTS: The most dominant motion component was medial irreversible displacement for the spina-scapula (1.87 mm; SD: 1.11 mm) and coracoid bone blocks (0.91 mm; SD: 0.29 mm) (n.s.). The most medial irreversible displacement took place during the first nine cycles. The inferior reversible displacement was significantly greater for spina-scapula bone blocks (0.28 mm, SD: 0.16 mm) compared to coracoid bone blocks (0.06 mm, SD: 0.10 mm) (p = 0.02). CONCLUSIONS: The medial irreversible displacement is the dominant motion component in a bone-block reconstruction after a critical bone loss of the anterior glenoid. The spina-scapula and coracoid bone blocks are comparable in terms of primary stability and extent of motion. Thus, spina-scapula bone blocks may serve as alternatives in bony glenoid reconstruction from a biomechanical point of view.


Assuntos
Instabilidade Articular , Articulação do Ombro , Humanos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Instabilidade Articular/etiologia , Instabilidade Articular/cirurgia , Transplante Ósseo/métodos , Escápula/diagnóstico por imagem , Escápula/cirurgia , Cadáver
4.
Arch Orthop Trauma Surg ; 143(12): 7123-7132, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37691046

RESUMO

INTRODUCTION: Combined PCL injuries involving the posteromedial/-lateral corner (PMC/PLC) usually require surgical management. Literature shows controversy regarding the standards of treatment. Suture-augmented repair leads to excellent results in acute knee dislocations but has not been investigated clinically in combined PCL injuries. The purpose of this multicentre study was to evaluate the clinical outcome of this technique in acute combined PCL injuries. MATERIALS & METHODS: N = 33 patients with acute combined PCL injuries involving the PMC/PLC were treated by one-stage suture repair with ligament bracing of the PCL and suture repair of the accompanying PMC/PLC injuries with/without ligament bracing or primary augmentation by semitendinosus autograft. Outcome was assessed by IKDC questionnaire, Lysholm Score, Tegner Activity Scale and KOOS. Additional PCL stress-radiography was performed. RESULTS: N = 31 patients with combined PCL injuries (female: male = 7:24; age 39.1 ± 13.8 years) with a follow-up of 16.8 ± 9.6 months were finally evaluated. 18 had PMC injuries, 13 PLC injuries. 32.2% presented with accompanying meniscal tears (70% medial meniscus). 19.4% showed cartilage injuries grade III-IV. Complications included one infection and four knee stiffnesses. Three had symptomatic postoperative instability, all affiliated to the PLC group. The IKDC was 69.8 ± 16.5, Lysholm score 85 ± 14.4 and KOOS 89.7 ± 8.1. Median loss of activity (Tegner) was 0.89 ± 1.31. Comparing PMC and PLC, all scores showed a tendency towards more favourable outcomes in the PMC group (n.s.). Stress-radiography showed an overall side-to-side difference of 3.7 ± 3.8 mm. Subgroup evaluation showed statistically significant better results (p = 0.035) of PMC (2.5 ± 1.5 mm) versus PLC (5.8 ± 5.6 mm). CONCLUSIONS: One-stage suture repair with ligament bracing is a viable technique for acute combined PCL injuries and predominantly leads to good and excellent clinical outcomes. Patients with PLC injuries show a tendency towards inferior outcomes and higher instability rates compared to PMC injuries. These results may help in therapy planning and counselling patients with these rare injury pattern. LEVEL OF EVIDENCE: Level II.


Assuntos
Lesões do Ligamento Cruzado Anterior , Instabilidade Articular , Ligamento Cruzado Posterior , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Articulação do Joelho/cirurgia , Ligamento Cruzado Posterior/cirurgia , Ligamento Cruzado Posterior/lesões , Lesões do Ligamento Cruzado Anterior/cirurgia , Instabilidade Articular/cirurgia , Ligamento Cruzado Anterior/cirurgia , Resultado do Tratamento , Seguimentos
5.
Medicina (Kaunas) ; 59(1)2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-36676737

RESUMO

Background and Objectives: Combined fractures of the humeral head and shaft (FHS) are rare but frequently involve an intermuscular fracture as its characteristic pattern. The aim of this retrospective study was to investigate intramedullary nailed and plated FHS in terms of outcomes and complications. Materials and Methods: The present study included patients with FHS, treated via either intramedullary nailing or plating within a period of 10 years, with a minimum follow-up of 12 months. Functional outcome was assessed using the age- and sex-adapted Constant-Murley Score (CMS-K). Rates of complications and revision surgeries were registered. Results: Twenty-five patients (18 females, 7 males, age 60.1 ± 14.2 years, range 23-76 years) were included in the study. Nailing was performed in 16 patients (12 females, 4 males, age 62.6 ± 12.4 years), whereas plating was executed in nine patients (6 females, 3 males, age 55.8 ± 17.0 years). Follow-up among all patients was 45.1 ± 26.3 months (range 12-97 months). CMS-K was 70.3 ± 32.3 in the nailing group, with reoperation in four cases, and 76.0 ± 31.0 in the plating group, with one reoperation (p = 0.42). Patients with no metaphyseal fragment displacement (n = 19; CMS-K 76.7 ± 17.3) demonstrated significantly better functional outcomes versus those with secondary displacement of the metaphyseal fragments (n = 6; CMS-K 60.0 ± 17.1), p = 0.046. Conclusions: Comparable acceptable clinical outcome is obtained when comparing nailing with additional open cerclage or lag-screw fixation techniques versus plating with open reduction. However, a higher revision rate was observed after nailing. The correct metaphyseal fragment fixation seems to be crucial to avoid loss of reduction and hence the need for revision surgery, as well as a worse outcome.


Assuntos
Fixação Intramedular de Fraturas , Fraturas do Úmero , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Fixação Intramedular de Fraturas/métodos , Cabeça do Úmero , Estudos Retrospectivos , Fraturas do Úmero/etiologia , Fraturas do Úmero/cirurgia , Placas Ósseas/efeitos adversos , Resultado do Tratamento
6.
BMC Musculoskelet Disord ; 23(1): 196, 2022 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-35236325

RESUMO

BACKGROUND: In the context of the German contact restrictions due to the COVID-19 pandemic of March 2020, an online-based consultation system was established in our university orthopedic outpatient department to maintain patient care. As a basis for contact-minimizing communication, this was continued after the contact restrictions were lifted. The aim of this prospective pilot study was to assess the effectiveness, technical feasibility, and patient flow in this system under lockdown conditions and in the period afterwards. METHODS: The evaluation took place from the beginning of the first lockdown on March 13, 2020, until May 31, 2021. For each patient encounter, the quality of the sound and video connections was documented. The outcomes of the consultations were recorded. Four categories were distinguished: 1) no follow-up necessary, 2) follow-up via online consultation, 3) referral for surgical therapy, and 4) follow-up in the outpatient clinic for physical examination. A comparison was made between an early cohort right after implementation of the online consultation and and a late cohort after establishment of the consultation. RESULTS: There were 408 patient encounters via online consultation. A total of 360 (88%) consultations were uninterrupted. Initial presentations accounted for 124 (30%) consultations. In 75 (18%) patients, no further follow-up was necessary. Follow-up via online consultation was scheduled in 82 (20%) patients, direct referral for surgery was made in 86 (21%) patients, and a follow-up for physical examination was arranged in 165 (40%) patients. When comparing the early and late cohort, there was no difference in the duration of the conversation (p = 0.23). A significant difference was found in the type of further treatment. In the late cohort, conservative therapy was used more often (p < 0.01), resulting in a lower number of follow-up visits for clinical examination (p < 0.01). CONCLUSION: While a definite decision for further procedure was possible solely by online consultation in a large percentage of cases, 40% of patients still needed an additional in-person consultation for physical examination. A learning curve could be observed regarding the selection of patients suited for online consultation. Overall, online consultation is a useful measure to manage patient volume and to visibly support direct doctor-patient contact.


Assuntos
COVID-19 , Telemedicina , Instituições de Assistência Ambulatorial , COVID-19/epidemiologia , Controle de Doenças Transmissíveis , Humanos , Curva de Aprendizado , Pandemias , Projetos Piloto , Estudos Prospectivos , Encaminhamento e Consulta , SARS-CoV-2
7.
Arch Orthop Trauma Surg ; 142(4): 641-648, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33884453

RESUMO

PURPOSE: Horizontal instability is a common problem after acromioclavicular joint injuries. The aim of this study was to evaluate if there is a difference regarding horizontal stability between an anatomical and a non-anatomical configuration of the double tunnel coraco-clavicular ligament reconstruction of the acromioclavicular joint. METHODS: Thirteen acromioclavicular joints of human cadaveric shoulders in ethanol-glycerin fixation were included in the study and underwent cyclic anterior and posterior translational testing at a load of 70 N using an electromechanical uniaxial testing machine. The shoulders were randomly assigned to the following groups: double coraco-clavicular tunnel technique in an anatomical configuration (DCTa) and double coraco-clavicular tunnel technique in an inverse configuration of the anatomical position (DCTb). The dislocation was recorded with a 3D optical measuring system. RESULTS: The total horizontal displacement (p10 = 0.0221; p5000 = 0.082) was significantly higher for the non-anatomical reconstruction (DCTb) compared to the anatomical reconstruction (DCTa) after every measured amount of cycles. The increase in displacement for DCTb group was overall higher than the increase in displacement for DCTa group but without significance. CONCLUSION: Reconstruction of the CC ligaments in an anatomical configuration with two suture devices results in a significantly higher stability of the AC joint in the horizontal plane than reconstruction of the CC ligaments in a non-anatomical configuration. Based on the results of this biomechanical in vitro study, the use of a double coraco-clavicular reconstruction should focus on an anatomically correct position of the suture devices.


Assuntos
Articulação Acromioclavicular , Artroplastia de Substituição , Luxações Articulares , Articulação Acromioclavicular/lesões , Articulação Acromioclavicular/cirurgia , Fenômenos Biomecânicos , Cadáver , Clavícula/lesões , Humanos , Luxações Articulares/cirurgia , Ligamentos Articulares/cirurgia
8.
Arch Orthop Trauma Surg ; 142(10): 2701-2709, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34258658

RESUMO

INTRODUCTION: This study aimed to investigate the influence of epidemiologic parameters on complications that needed operative revision of operatively treated proximal humerus fractures. METHODS: We performed a retrospective single-center study in a level 1 trauma center. We included all patients with operatively treated proximal humerus fractures from January 1 2005 to December 31 2015. We characterized our cohort and subgroup using descriptive statistics. The primary outcome was postoperative complications. For this purpose, postoperative complications were defined in advance, an operative revision was necessary on a general rule. The secondary outcome was a model of the risk factors for complications created with multiple logistic regression. RESULTS: We included 1109 patients. The average age was 67.2 years (± 16.4), and 71.4% of the fractures occurred in women. A total of 644 patients (58.1%) had between one to three comorbidities, and 27.8% had four or more. The fracture morphology was as follows: 3 part 41.8%, 4 part 26.9%, 2 part 24.3%, and dislocation fracture 6.7%. Complications occurred in 150 patients (13.5%). The number of comorbidities [odds ratio (OR) 2.85, p < 0.01], body weight (OR 1.15, p = 0.02), and substance abuse (OR 1.82, p = 0.04) significantly correlated with the risk of complications. We achieved a sensitivity of 48% and a specificity of 74% for the variables body weight, substance abuse, age, and comorbidities CONCLUSION: The epidemiologic parameters, comorbidities, substance abuse, weight, and age are independent risk factors for complications. If these factors are present, one can predict a postoperative complication requiring surgical revision with low sensitivity and moderate specificity. Therefore, concerning the high number of multi-morbid patients with proximal humerus fractures, an increased postoperative complication rate can be expected. LEVEL OF EVIDENCE: Level of evidence IV.


Assuntos
Fraturas do Ombro , Transtornos Relacionados ao Uso de Substâncias , Idoso , Peso Corporal , Feminino , Fixação Interna de Fraturas/efeitos adversos , Humanos , Úmero/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Fatores de Risco , Fraturas do Ombro/epidemiologia , Fraturas do Ombro/cirurgia , Transtornos Relacionados ao Uso de Substâncias/etiologia , Resultado do Tratamento
9.
Arch Orthop Trauma Surg ; 142(7): 1385-1393, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33484306

RESUMO

INTRODUCTION: Inferior tendon quality, wide retraction, and tendon stumps that cannot be mobilized define the limits of what is technically feasible for open and arthroscopic rotator cuff reconstruction. The aim of this study was to develop a procedure that enables the open reconstruction of otherwise non-reconstructable rotator cuff tears. METHODS: From 2014 to 2018, 23 operations were performed on 21 patients (mean age 63) using open procedure involving separating the infraspinatus tendon from the point of insertion on the greater tubercle and mobilizing it proximally and ventrally into the defective area. Any remaining defects were augmented using an autologous biceps tendon interposition graft. This augmentation was performed to achieve complete closure of the defect. Furthermore, the augmentation of the rupture zone was intended to strengthen the tendon stumps of the SSP and ISP to better neutralize the initial tensile forces. After a postoperative period of 12 months-4 years, clinical examination and functional tests were carried out, the Constant score was determined, and radiological and magnetic resonance imaging check-up examinations were performed. RESULTS: The technique resulted in a low-tension closure of an otherwise "non-repairable" superior rotator cuff defect. All patients experienced a significant functional improvement, a reduction in pain, and an increase in muscle strength. An improvement in the Constant score from 48 points preoperatively to 87 points postoperatively (p < 0.05) was observed. In 19 patients (90%), the magnetic resonance image showed an intact reconstruction. Re-rupture was seen in three patients (14%). CONCLUSION: The surgical procedure using infraspinatus tendon shift and autologous biceps tendon interposition grafts resulted in the successful reconstruction of otherwise non-reconstructable massive rotator cuff lesions. The complete closure of the defect was observed.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Artroscopia/métodos , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Manguito Rotador/patologia , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/patologia , Lesões do Manguito Rotador/cirurgia , Ruptura , Tendões/cirurgia , Resultado do Tratamento
10.
Arch Orthop Trauma Surg ; 142(11): 3213-3220, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34363523

RESUMO

INTRODUCTION: Incongruent stabilization of the distal tibiofibular joint (syndesmosis) results in poorer long-term outcome in malleolar fractures. The aim was to analyze whether the orientation of the syndesmotic stabilization would affect the immediate reduction imaged in computed tomography (CT). MATERIALS AND METHODS: The syndesmotic congruity in 114 ankle fractures with stabilization of the syndesmosis were retrospectively analyzed in the post-operative bilateral CT scans. The incisura device angle (IDA) was defined and correlated with the side-to-side difference of Leporjärvi clear-space (ΔLCS), anterior tibiofibular distance (ΔantTFD) and Nault talar dome angle (ΔNTDA) regardless of the stabilization technique and separately for suture button system and syndesmotic screw. Asymmetric reduction was defined as ΔLCS > 2 mm and |ΔantTFD|> 2 mm. RESULTS: Regardless of the stabilization technique, no correlation between the IDA and the ΔLCS (r = 0.069), the ΔantTFD (r = 0.019) nor the ΔNTDA (r = 0.177) could be observed. There were no differences between suture button system and syndesmotic screw. Asymmetrical reduction was detected in 46% of the cases, while sagittal asymmetry was most common. No association was found between the orientation of stabilization device and occurrence of asymmetrical reduction (p > 0.05). The results of suture button system and syndesmotic screw were comparable in this respect (p > 0.05). CONCLUSION: Poor correlation between the orientation of the stabilization device and the immediate post-operative congruity of the syndesmosis could be shown. In contrast to current literature, this study did not show difference of suture button system over syndesmotic screw in this regard. Careful adjustment of the fibula in anteroposterior orientation should be given special attention.


Assuntos
Fraturas do Tornozelo , Traumatismos do Tornozelo , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Traumatismos do Tornozelo/diagnóstico por imagem , Traumatismos do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Parafusos Ósseos , Fíbula/cirurgia , Fixadores , Fixação Interna de Fraturas/métodos , Humanos , Estudos Retrospectivos
11.
BMC Med Imaging ; 21(1): 41, 2021 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-33676399

RESUMO

BACKGROUND: Assessment of tibiofibular reduction presents an intra- and postoperative challenge. Numerous two-dimensional measurement methods have been described, most of them highly dependent on leg orientation and rater. Aim of the present work was to develop a standardized and orientation-independent 3D based method for the assessment of syndesmotic joint position. METHODS: In a retrospective single center study, 3D models of bilateral ankle joints, either after unilateral syndesmosis stabilization (operative group) or with no injury (native group) were superimposed (best fit matching) and aligned uniformly. Based on center of gravity calculations three orientation- and rater-independent parameters were determined: tibiofibular clears space (CS), vertical offset between both fibulae, and translation angle of the fibulae about tibia axis. RESULTS: Bilateral CT datasets of 57 native and 47 postoperative patients were analyzed. In the native group mean CS was 2.7 (SD, 0.8; range, 0.7-4.9) mm, mean CS side difference was 0.62 (SD, 0.45) mm and mean translation angle was 1.6 (SD, 1.4) degrees regarding absolute values. The operative group was found to show a significantly higher CS side difference of 0.88 (SD, 0.75) mm compared to native group (P = .046). Compared to the healthy contralateral side, operated fibulae showed mean proximal displacement of 0.56 (SD, 1.67) mm (P = .025), dorsal displacement of 1.5 (SD 4.1) degrees (P = .017). CONCLUSION: By using 3D best fit matching, orientation- and rater-dependent errors can be minimized. Large interindividual and small intraindividual differences of uninjured couples support previous recommendations for bilateral imaging. TRIAL REGISTRATION: AZ 131/18-ek; AZ 361/19-ek LEVEL OF EVIDENCE: Level III.


Assuntos
Traumatismos do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/diagnóstico por imagem , Imageamento Tridimensional , Tomografia Computadorizada por Raios X/métodos , Traumatismos do Tornozelo/cirurgia , Articulação do Tornozelo/anatomia & histologia , Conjuntos de Dados como Assunto , Feminino , Humanos , Masculino , Modelos Anatômicos , Período Pós-Operatório , Estudos Retrospectivos
12.
BMC Musculoskelet Disord ; 22(1): 528, 2021 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-34107940

RESUMO

BACKGROUND: The purpose of this study was to present a navigated image-free augmentation technique for the acromioclavicular joint (ACJ) and coracoclavicular (CC) ligaments and to report the clinical and radiological outcomes. METHODS: From 2013 to 2018, 35 eligible patients were treated with our navigated image-free ACJ- and CC-augmentation technique. The average follow-up was 3 years. Follow-up evaluations included the Constant-Murley Score, subjective shoulder value, Taft score, and the acromioclavicular joint instability (ACJI) score. The patients' quality of life was assessed using the EuroQol-5D (EQ-5D) questionnaire. In addition, in accordance with the instability criteria, radiographs were evaluated before surgery, after surgery, and during follow-up. RESULTS: Overall, 25 patients (71%) suffered an acute type V disruption, 5 (14%) had a type IV disruption, and 5 (14%) had an acute Rockwood type IIIb injury. The mean Constant-Murley Score was 90 (range: 56-100; p = 0.53) on the injured side, and the mean subjective shoulder value was 92% (range: 80-100%). The mean Taft and ACJI scores were 10 (range: 4-12) and 86 (range: 34-100), respectively and the mean EQ-5D was 86 (range: 2-100). The mean CC difference of the injured side was 4 mm (range: 1.9-9.1 mm) at follow-up, which was not significantly different than that of the healthy side (p = 0.06). No fractures in the area of the clavicle or the coracoid were reported. CONCLUSIONS: The arthroscopic- and navigation-assisted treatment of high-grade ACJ injuries in an anatomical double-tunnel configuration yields similar clinical and radiological outcomes as the conventional technique using an aiming device. Precise positioning of the navigation system prevents multiple drillings, which avoids fractures.


Assuntos
Articulação Acromioclavicular , Luxações Articulares , Articulação Acromioclavicular/diagnóstico por imagem , Articulação Acromioclavicular/cirurgia , Artroscopia , Humanos , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/cirurgia , Ligamentos Articulares/diagnóstico por imagem , Ligamentos Articulares/cirurgia , Qualidade de Vida , Resultado do Tratamento
13.
BMC Musculoskelet Disord ; 22(1): 531, 2021 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-34107953

RESUMO

BACKGROUND: Surgical site infection (SSI) occurs in 3-10 % of patients with surgically treated tibial plateau fractures. This study aimed to evaluate the impact of SSI on patients' outcome after fixation of tibial plateau fractures. METHODS: We conducted a retrospective multicenter study in seven participating level I trauma centers between January 2005 and December 2014. All participating centers followed up with patients with SSI. In addition, three centers followed up with patients without SSI as a reference group. Descriptive data and follow-up data with patient-reported outcome scores (Knee Injury and Osteoarthritis Outcome Score [KOOS] and Lysholm knee scoring scale score) were evaluated. RESULTS: In summary, 287 patients (41 with SSI and 246 without SSI; average 50.7 years) with an average follow-up of 75.9 ± 35.9 months were included in this study. Patients with SSI had a significantly poorer overall KOOS (KOOS5) (48.7 ± 23.2 versus [vs.] 71.5 ± 23.5; p < 0.001) and Lysholm knee scoring scale score (51.4 ± 24.0 vs. 71.4 ± 23.5; p < 0.001) than patients without SSI. This significant difference was also evident in the KOOS subscores for pain, symptoms, activities of daily living (ADL), and quality of life (QoL). SSI remained an important factor in multivariable models after adjusting for potential confounders. Clinically relevant differences in the KOOS5 and KOOS subscores for symptoms, pain, and ADL were found between those with SSI and without SSI even after adjustment. Furthermore, the number of previous diseases, Arbeitsgemeinschaft für Osteosynthesefragen Foundation (AO) C fractures, and compartment syndrome were found to be additional factors related to poor outcome. CONCLUSIONS: Compared to previous studies, validated patient-reported outcome scores demonstrated that the impact of SSI in patients with surgically treated tibial plateau fractures is dramatic, in terms of not only pain and symptoms but also in ADL and QoL, compared to that in patients without SSI.


Assuntos
Qualidade de Vida , Fraturas da Tíbia , Atividades Cotidianas , Fixação Interna de Fraturas/efeitos adversos , Humanos , Estudos Retrospectivos , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/etiologia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Resultado do Tratamento
14.
BMC Musculoskelet Disord ; 22(1): 970, 2021 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-34809628

RESUMO

BACKGROUND: Inadequate reduction of syndesmotic injuries can result in disabling clinical outcomes. The aim of the study was to compare syndesmosis congruity after fixation by syndesmotic screws (SYS) or a suture button system (SBS) using three-dimensional (3D) computed imaging techniques. METHODS: In a retrospective single-center study, patients with unilateral stabilization of an ankle fracture with a syndesmotic injury and post-operative bilateral CT scans were analyzed using a recently established 3D method. The side-to-side differences were compared for tibio-fibular clear space (∆CS), translation angle (∆α), and vertical offset (∆z) among patients stabilized with syndesmotic screws or suture button system. Syndesmotic malreduction was defined for ∆CS > 2 mm and for |∆α| > 5°. ∆CS and ∆α were correlated with two-dimensional (2D) measurements. RESULTS: Eighteen patients stabilized with a syndesmosis screw and 29 stabilized with a suture button system were analyzed. After stabilization, both groups revealed mild diastasis (SYS: mean ∆CS 0.3 mm, SD 1.1 mm vs SBS: mean ∆CS 0.2 mm, SD 1.2 mm, p = 0.710). In addition, both stabilization methods showed slight dorsalization of the fibula (SYS: mean ∆α 0.5°, SD 4.6° vs SBS: mean ∆α 2.1°, SD 3.7°, p = 0.192). Also, restoration of the fibula-to-tibia length ratio also did not differ between the two groups (SYS: mean Δz of 0.5 mm, SD 2.4 mm vs SBS: mean Δz of 0 mm, SD 1.2 mm; p = 0.477). Malreduction according to high ∆α was most common (26% of cases), with equal distribution between the groups (p = 0.234). ∆CS and ∆α showed good correlation with 2D measurements (ρ = 0.567; ρ = 0.671). CONCLUSION: This in vivo analysis of post-operative 3D models showed no differences in immediate post-operative alignment after syndesmotic screws or suture button system. Special attention should be paid to syndesmotic malreduction in the sagittal orientation of the fibula in relation to the tibia in radiological control of the syndesmotic congruity as well as intra-operatively.


Assuntos
Fraturas do Tornozelo , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Parafusos Ósseos , Fixação Interna de Fraturas , Humanos , Imageamento Tridimensional , Estudos Retrospectivos , Técnicas de Sutura , Suturas
15.
Int Orthop ; 44(10): 2095-2100, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32440814

RESUMO

PURPOSE: To define a new parameter in CT that could make imaging of the contralateral ankle dispensable evaluating the position of the fibula after syndesmotic injury. METHODS: Thirty bilateral CTs of 30 patients were included. Five parameters were defined in axial CT for the injured (_inju) and uninjured (_unin) ankle. Reproducibility was examined for inter-observer and intra-observer reliability. Comparisons for all parameters were performed between the CT scans of both ankles. RESULTS: All measurements had a high agreement for the inter-observer and intra-observer correlation coefficients. A large interindividual variance could be found between all parameters. If the difference of the anterior tibiofibular distance antTFD_unin and antTFD_inju was less than 2 mm, there was a strong significant pairwise correlation between all parameters between both sides. CONCLUSION: Bilateral CT is still to be recommended, as it is the only way to exactly assess anterior posterior reduction of the fibula.


Assuntos
Traumatismos do Tornozelo , Tornozelo , Traumatismos do Tornozelo/diagnóstico por imagem , Traumatismos do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Fíbula/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes
16.
Arch Orthop Trauma Surg ; 140(4): 511-516, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31980876

RESUMO

PURPOSE: Numerous techniques have been described for the tibial-sided graft preparation in anterior cruciate ligament (ACL) reconstruction. The use of less suture material for graft preparation is thought to improve ingrowth and to reduce the risk for infection. At the same time, the suture construct should be strong enough to resist the surgeon's pull during tensioning of the transplant. METHODS: In total, 39 fresh-frozen procine deep flexor tendons were used and prepared as four-strand grafts. In the three-suture group (n = 19), graft preparation was performed using three tibial-sided sutures, with each tendon end sutured separately. In the one-suture group (n = 20), a modified graft preparation using only one tibial-sided suture was applied. Each sample underwent load-to-failure testing (Nmax) after cyclic pre-loading. To estimate intraoperative tension forces acting on the tibial-sided suture constructs, the maximal tension force of 26 volunteers on such a construct was measured using a load cell. RESULTS: The biomechanical testing of the two different suture constructs showed a significantly higher load-to-failure for the three-suture group (711 N ± 91 N) compared to the one-suture group (347 N ± 24 N) (p = 0.0001). In both groups, the mode of failure was a tear of the suture in all samples. A failure of the suture-tendon interface was not observed in any case. The median maximal tension force on the construct applied by the 26 volunteers was 134 N (range 73-182 N). CONCLUSION: The presented single-suture tendon graft preparation resisted to smaller failure loads than the conventional three-suture technique. However, no failures in the suture-tendon interface were seen and the failure loads observed were far beyond the tension forces that can be expected intraoperatively. Hence, the single-suture graft preparation technique may be a valuable alternative to the conventional technique.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirurgia , Técnicas de Sutura , Tendões/transplante , Tíbia/cirurgia , Animais , Suínos
17.
BMC Musculoskelet Disord ; 20(1): 262, 2019 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-31142297

RESUMO

BACKGROUND: Due to the high anatomical variability and limited visualization of the scapula, optimal screw placement for baseplate anchorage in reversed total shoulder arthroplasty (rTSA) is challenging. Image quality plays a key role regarding the decision of an appropriate implant position. However, these data a currently missing for rTSA and were investigated in the present study. Furthermore, the rate of required K-wire changes for the central peg as well as post-implantation inclination and version were assessed. METHODS: In ten consecutive patients (8 female, 86 years, range 74-94) with proximal humeral fracture and indication for rTSA, an intraoperative 3D-scan of the shoulder with a 3D image intensifier (Ziehm Vision FD Vario 3D© [Ziehm Imaging GmbH, Nürnberg, Germany]) was performed after resection of the humeral head. Using the Vectorvision© Software (Brainlab AG, Feldkirchen, Germany), the virtual anatomy was compared to the visible anatomical landmarks. After implantation of the baseplate, a 3D scan was performed. All 3D scans included multiplanar reconstruction (MPR) and the cinemode to examine screw and baseplate placement. The rate of required K-wire changes was assessed. The intraoperative 3D image quality (modified visual analogue scale [VAS] and point system) was assessed before and after implantation of the glenoid component. Inclination and version were determined in post-implantation scans. RESULTS: The virtually presented anatomical landmarks always correlated to the anatomical visible points indicating an good virtual accuracy. The central K-wire position was corrected in three cases due to a deviation from the face plane technique position. The VAS was higher for the pre-implantation MPR (6.7, range 5-8) compared to the post-implantation acquired MPR (5.1, range 4-6; p = 0.0002). The point system showed a reduced quality in all subcategories, especially regarding the grading of the articular surfaces. The preoperative (7.9, range 6-9) and post-implantation (7.9, range 6-9) cinemode displayed no significant differences (p = 0.6). CONCLUSION: The present study underlines the need for the improvement of 3D image intensifiers algorithms to reduce artifact associated impaired image quality to enhance the benefit of real-time intraoperative 3D scans and navigation.


Assuntos
Artroplastia do Ombro/métodos , Imageamento Tridimensional , Intensificação de Imagem Radiográfica/métodos , Articulação do Ombro/diagnóstico por imagem , Cirurgia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluoroscopia/métodos , Humanos , Período Intraoperatório , Masculino , Estudos Retrospectivos , Articulação do Ombro/cirurgia
18.
Knee Surg Sports Traumatol Arthrosc ; 27(12): 3827-3834, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31420689

RESUMO

PURPOSE: Horizontal instability-especially in the posterior plane-is a common problem after acromioclavicular joint injuries. The purpose was to compare the stability of a single coraco-clavicular tunnel technique and a double coraco-clavicular tunnel technique for coraco-clavicular ligament reconstruction and to examine the influence of an additional acromioclavicular cerclage on the horizontal stability in the acromioclavicular joint. METHODS: 21 acromioclavicular joints of human cadaveric shoulders were randomly assigned to the following groups: single coraco-clavicular tunnel technique with horizontal augmented acromioclavicular cerclage (SCT + AC); double coraco-clavicular tunnel technique (DCT); double coraco-clavicular tunnel technique and acromioclavicular cerclage (DCT + AC). The specimens underwent cyclic horizontal testing and were recorded using a 3D optical measuring system. RESULTS: The displacement and the increase in displacement in relation to the displacement after precondition for SCT + AC were significantly higher after every measured amount of cycles than for DCT (p10 = 0.0023; p5000 = 0.0012) and DCT + AC (p10 = 0.0006; p5000 = 0.0012). There was no significant difference in the total displacement, or in the increase in total displacement between double coraco-clavicular tunnel reconstructed groups with and without additional acromioclavicular cerclage. CONCLUSION: Double coraco-clavicular tunnel technique with and without additional acromioclavicular cerclage results in a significant higher stability regarding the horizontal plane in comparison to single coraco-clavicular tunnel technique with acromioclavicular cerclage. Based on the results of this biomechanical in vitro study, the use of an additional acromioclavicular cerclage with single coraco-clavicular tunnel technique may not be indicated in most cases. The effect of an additional acromioclavicular cerclage seems to be negligible, at least in presence of a double-coraco-clavicular tunnel technique reconstruction. Techniques of AC joint reconstruction should focus on the use of double coraco-clavicular tunnel devices.


Assuntos
Articulação Acromioclavicular/cirurgia , Artroscopia/métodos , Instabilidade Articular/cirurgia , Idoso de 80 Anos ou mais , Cadáver , Humanos
19.
BMC Med Imaging ; 17(1): 47, 2017 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-28764643

RESUMO

BACKGROUND: The purpose of this study was to investigate the accuracy of perforation detection with multiplanar reconstructions using a mobile 3D image intensifier. METHODS: In 12 paired human humeri, K-wires perforating the subchondral bone and placed just below the cartilage level were directed toward five specific regions in the humeral head. Image acquisition was initiated by a fluoroscopy scan. Within a range of 90°, 45° external rotation (ER) and 45° internal rotation (IR). The number and percentage of detected perforating screws were grouped and analyzed. Furthermore, the fluoroscopic images were converted into multiplanar CT-like reconstructions. Each K-wire perforation was characterized as "detected" or "not detected". RESULTS: In the series of fluoroscopy images in the standard neutral position at 30° internal rotation, and 30° external rotation, the perforations of all K-wires (n = 56) were detected. Twenty-nine (51.8%) of them were detected in one AP view, 22 (39.3%) in two AP views, and five (8.9%) in three AP views. All K-wire perforations (100%, n = 56) were detected in multiplanar reconstructions. CONCLUSION: In order to reveal all of the intraoperative and postoperative screw perforations in a "five screw configuration", conventional AP images should be established in both the neutral positions (0°), at 30° internal rotation and 30° external rotation. Alternatively, the intraoperative 3D scan with multiplanar reconstructions enables a 100% rate of detection of the screw perforations.


Assuntos
Fixação Interna de Fraturas/efeitos adversos , Imageamento Tridimensional/métodos , Fraturas do Ombro/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Parafusos Ósseos , Cadáver , Feminino , Fixação Interna de Fraturas/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Óptica , Fraturas do Ombro/cirurgia , Cirurgia Assistida por Computador/métodos
20.
BMC Musculoskelet Disord ; 18(1): 481, 2017 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-29162084

RESUMO

BACKGROUND: To systematically review all available studies of operatively treated proximal tibia fractures and to report the incidence of superficial or deep infection and subsequent outcomes. METHODS: A systematic review of the literature in Medline, Cochrane, Embase and GoogleScholar was conducted to identify studies with cohorts of patients with infection after surgical treatment of proximal tibia fractures. Studies were included according to predefined inclusion and exclusion criteria. The studies were analysed for methodological deficiencies and quality of outcome reporting based on the Level of Evidence (LOE) and Coleman Methodology Scoring (CMS.) RESULTS: In total 32 studies were included. There was heterogeneity between the studies, in terms of subject of the studies, outcome criteria, fracture type and classification, surgical techniques and length of follow-up. Therefore, no meta-analysis could be performed. The average CMS was 54.2 (range 36-75). The included studies were 25 case series (LOE IV), 6 were prospective cohort studies (LOE III) and one was a prospective randomized trial (LOE I). 203 (12.3%, range: 2.6-45.0%) infections occurred in the overall population (n = 2063). Those were divided into 129 deep infections and 74 superficial infections. Revision due to infection was reported in 29 studies, microbiological results in 6, respectively. 72 (55,8%) of 129 cases reporting outcome after deep infection had an unsatisfactory outcome with substantial limitations of the affected joint and leg. CONCLUSIONS: Postoperative infections are a challenge, sometimes requiring several revisions and often with a worse outcome. Further studies with structured study protocols should be performed for a better understanding of risk factors to improve treatment outcomes.


Assuntos
Fixação de Fratura/efeitos adversos , Infecção da Ferida Cirúrgica/epidemiologia , Fraturas da Tíbia/cirurgia , Fixação de Fratura/métodos , Fixação de Fratura/estatística & dados numéricos , Humanos , Incidência , Complicações Pós-Operatórias , Reoperação/estatística & dados numéricos , Fatores de Risco , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/microbiologia , Tíbia/lesões , Tíbia/cirurgia , Fraturas da Tíbia/epidemiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa