Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Electrophoresis ; 38(18): 2232-2241, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28543881

RESUMO

Metabolomics has been found to be applicable to a wide range of clinical studies, bringing a new era for improving clinical diagnostics, early disease detection, therapy prediction and treatment efficiency monitoring. A major challenge in metabolomics, particularly untargeted studies, is the extremely diverse and complex nature of biological specimens. Despite great advances in the field there still exist fundamental needs for considering pre-analytical variability that can introduce bias to the subsequent analytical process and decrease the reliability of the results and moreover confound final research outcomes. Many researchers are mainly focused on the instrumental aspects of the biomarker discovery process, and sample related variables sometimes seem to be overlooked. To bridge the gap, critical information and standardized protocols regarding experimental design and sample handling and pre-processing are highly desired. Characterization of a range variation among sample collection methods is necessary to prevent results misinterpretation and to ensure that observed differences are not due to an experimental bias caused by inconsistencies in sample processing. Herein, a systematic discussion of pre-analytical variables affecting metabolomics studies based on blood derived samples is performed. Furthermore, we provide a set of recommendations concerning experimental design, collection, pre-processing procedures and storage conditions as a practical review that can guide and serve for the standardization of protocols and reduction of undesirable variation.


Assuntos
Coleta de Amostras Sanguíneas , Metabolômica , Humanos
2.
Metabolites ; 11(4)2021 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-33805952

RESUMO

Arrhythmogenic cardiomyopathy (ACM) is a genetic-based cardiac disease accompanied by severe ventricular arrhythmias and a progressive substitution of the myocardium with fibro-fatty tissue. ACM is often associated with sudden cardiac death. Due to the reduced penetrance and variable expressivity, the presence of a genetic defect is not conclusive, thus complicating the diagnosis of ACM. Recent studies on human induced pluripotent stem cells-derived cardiomyocytes (hiPSC-CMs) obtained from ACM individuals showed a dysregulated metabolic status, leading to the hypothesis that ACM pathology is characterized by an impairment in the energy metabolism. However, despite efforts having been made for the identification of ACM specific biomarkers, there is still a substantial lack of information regarding the whole metabolomic profile of ACM patients. The aim of the present study was to investigate the metabolic profiles of ACM patients compared to healthy controls (CTRLs). The targeted Biocrates AbsoluteIDQ® p180 assay was used on plasma samples. Our analysis showed that ACM patients have a different metabolome compared to CTRLs, and that the pathways mainly affected include tryptophan metabolism, arginine and proline metabolism and beta oxidation of fatty acids. Altogether, our data indicated that the plasma metabolomes of arrhythmogenic cardiomyopathy patients show signs of endothelium damage and impaired nitric oxide (NO), fat, and energy metabolism.

3.
Appl Spectrosc ; 70(11): 1910-1915, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27324420

RESUMO

Energy-dispersive X-ray fluorescence (ED-XRF) spectroscopy with data treatment via chemometric tools was explored as an analytical protocol to discriminate between authentic and counterfeit revenue stamps. Untreated samples were directly analyzed, and the discrimination was based on the characterization of constituent elements present in the inks and paper. Authentic samples and samples that were suspected of being counterfeit were analyzed at three different areas on their surfaces: the ink-printed area, the non-printed area, and the holographic area. Principal component analysis (PCA) was applied to the data to discriminate between authentic and counterfeit revenue stamps. Major differences in the elemental composition were noted (according to chemometrics and t-test, p < 0.05), and ED-XRF spectroscopy plus PCA protocol is proposed for use by non-specialist operators to screen for counterfeit stamps.

4.
Forensic Sci Int ; 249: 156-64, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25700111

RESUMO

Ammonium nitrate fuel oil (ANFO) is an explosive used in many civil applications. In Brazil, ANFO has unfortunately also been used in criminal attacks, mainly in automated teller machine (ATM) explosions. In this paper, we describe a detailed characterization of the ANFO composition and its two main constituents (diesel and a nitrate explosive) using high resolution and accuracy mass spectrometry performed on an FT-ICR-mass spectrometer with electrospray ionization (ESI(±)-FTMS) in both the positive and negative ion modes. Via ESI(-)-MS, an ion marker for ANFO was characterized. Using a direct and simple ambient desorption/ionization technique, i.e., easy ambient sonic-spray ionization mass spectrometry (EASI-MS), in a simpler, lower accuracy but robust single quadrupole mass spectrometer, the ANFO ion marker was directly detected from the surface of banknotes collected from ATM explosion theft.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa