Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Sensors (Basel) ; 24(4)2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38400239

RESUMO

This paper addresses the challenging issue of achieving high spatial resolution in temperature monitoring of printed circuit boards (PCBs) without compromising the operation of electronic components. Traditional methods involving numerous dedicated sensors such as thermocouples are often intrusive and can impact electronic functionality. To overcome this, this study explores the application of ultrasonic guided waves, specifically utilising a limited number of cost-effective and unobtrusive Piezoelectric Wafer Active Sensors (PWAS). Employing COMSOL multiphysics, wave propagation is simulated through a simplified PCB while systematically varying the temperature of both components and the board itself. Machine learning algorithms are used to identify hotspots at component positions using a minimal number of sensors. An accuracy of 97.6% is achieved with four sensors, decreasing to 88.1% when utilizing a single sensor in a pulse-echo configuration. The proposed methodology not only provides sufficient spatial resolution to identify hotspots but also offers a non-invasive and efficient solution. Such advancements are important for the future electrification of the aerospace and automotive industries in particular, as they contribute to condition-monitoring technologies that are essential for ensuring the reliability and safety of electronic systems.

2.
J Acoust Soc Am ; 149(6): 4228, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34241474

RESUMO

A portable device for the rapid concentration of Bacillus subtilis var niger spores, also known as Bacillus globigii (BG), using a thin-reflector acoustofluidic configuration is described. BG spores form an important laboratory analog for the Bacillus anthracis spores, a serious health and bioterrorism risk. Existing systems for spore detection have limitations on detection time and detection that will benefit from the combination with this technology. Thin-reflector acoustofluidic devices can be cheaply and robustly manufactured and provide a more reliable acoustic force than previously explored quarter-wave resonator systems. The system uses the acoustic forces to drive spores carried in sample flows of 30 ml/h toward an antibody functionalized surface, which captures and immobilizes them. In this implementation, spores were fluorescently labeled and imaged. Detection at concentrations of 100 CFU/ml were demonstrated in an assay time of 10 min with 60% capture. We envisage future systems to incorporate more advanced detection of the concentrated spores, leading to rapid, sensitive detection in the presence of significant noise.


Assuntos
Bacillus anthracis , Bacillus , Acústica , Esporos Bacterianos
3.
Sensors (Basel) ; 21(21)2021 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-34770696

RESUMO

The computer modelling of condition monitoring sensors can aide in their development, improve their performance, and allow for the analysis of sensor impact on component operation. This article details the development of a COMSOL model for a guided wave-based temperature monitoring system, with a view to using the technology in the future for the temperature monitoring of nozzle guide vanes, found in the hot section of aeroengines. The model is based on an experimental test system that acts as a method of validation for the model. Piezoelectric wedge transducers were used to excite the S0 Lamb wave mode in an aluminium plate, which was temperature controlled using a hot plate. Time of flight measurements were carried out in MATLAB and used to calculate group velocity. The results were compared to theoretical wave velocities extracted from dispersion curves. The assembly and validation of such a model can aide in the future development of guided wave based sensor systems, and the methods provided can act as a guide for building similar COMSOL models. The results show that the model is in good agreement with the experimental equivalent, which is also in line with theoretical predictions.


Assuntos
Som , Transdutores , Simulação por Computador , Temperatura
4.
J Acoust Soc Am ; 145(2): 945, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30823821

RESUMO

Steering micro-objects using acoustic radiation forces is challenging for several reasons: resonators tend to create fixed force distributions that depend primarily on device geometry, and even when using switching schemes, the forces are hard to predict a priori. In this paper an active approach is developed that measures forces from a range of acoustic resonances during manipulation using a computer controlled feedback loop based in matlab, with a microscope camera for particle imaging. The arrangement uses a planar resonator where the axial radiation force is used to hold particles within a levitation plane. Manipulation is achieved by summing the levitation frequency with an algorithmically chosen second resonance frequency, which creates lateral forces derived from gradients in the kinetic energy density of the acoustic field. Apart from identifying likely resonances, the system does not require a priori knowledge of the structure of the acoustic force field created by each resonance. Manipulation of 10 µm microbeads is demonstrated over 100 s µm. Manipulation times are of order 10 s for paths of 200 µm length. The microfluidic device used in this work is a rectangular glass capillary with a 6 mm wide and 300 µm high fluid chamber.

5.
J Vasc Interv Radiol ; 28(2): 260-268.e2, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27641675

RESUMO

PURPOSE: To investigate material density, flow, and viscosity effects on microsphere distribution within an in vitro model designed to simulate hepatic arteries. MATERIALS AND METHODS: A vascular flow model was used to compare distribution of glass and resin surrogates in a clinically derived flow range (60-120 mL/min). Blood-mimicking fluid (BMF) composed of glycerol and water (20%-50% vol/vol) was used to simulate a range of blood viscosities. Microsphere distribution was quantified gravimetrically, and injectate solution was dyed to enable quantification by UV spectrophotometry. Microsphere injection rate (5-30 mL/min) and the influence of contrast agent dilution of injection solution (0%-60% vol/vol) were also investigated. RESULTS: No significant differences in behavior were observed between the glass and resin surrogate materials under any tested flow conditions (P = .182; n = 144 injections). Microspheres tend to align more consistently with the saline injection solution (r2 = 0.5712; n = 144) compared with total BMF flow distribution (r2 = 0.0104; n = 144). The most predictable injectate distribution (ie, greatest alignment with BMF flow, < 5% variation) was demonstrated with > 10-mL/min injection rates of pure saline solution, although < 20% variation with glass microsphere distribution was observed with injection solution containing as much as 30% contrast medium when injected at > 20 mL/min. CONCLUSIONS: Glass and resin yttrium-90 surrogates demonstrated similar distribution in a range of clinically relevant flow conditions, suggesting that microsphere density does not have a significant influence on microsphere distribution. Injection parameters that enhanced the mixing of the spheres with the BMF resulted in the most predictable distribution.


Assuntos
Embolização Terapêutica/métodos , Vidro/química , Artéria Hepática/fisiopatologia , Circulação Hepática , Neoplasias Hepáticas/terapia , Modelos Anatômicos , Modelos Cardiovasculares , Compostos Radiofarmacêuticos/administração & dosagem , Resinas Sintéticas/química , Radioisótopos de Ítrio/administração & dosagem , Velocidade do Fluxo Sanguíneo , Viscosidade Sanguínea , Glicerol/química , Artéria Hepática/patologia , Humanos , Neoplasias Hepáticas/irrigação sanguínea , Microesferas , Fluxo Sanguíneo Regional , Técnicas de Réplica , Água/química
6.
Phys Chem Chem Phys ; 18(26): 17311-9, 2016 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-27326792

RESUMO

Ni/Al2O3, Co/Al2O3 and bimetallic Ni(Co)/Al2O3 catalysts were prepared using an impregnation method and employed in CO2 dry reforming of methane under coking-favored conditions. The spent catalysts were carefully characterized using typical characterization technologies and inelastic neutron scattering spectroscopy. The bimetallic catalyst exhibited a superior activity and anti-coking performance compared to Ni/Al2O3, while the most resistant to coking behavior was Co/Al2O3. The enhanced activity of the Ni(Co)/Al2O3 bimetallic catalyst is attributed to the reduced particle size of metallic species and resistance to forming stable filamentous carbon. The overall carbon deposition on the spent bimetallic catalyst is comparable to that of the spent Ni/Al2O3 catalyst, whereas the carbon deposited on the bimetallic catalyst is mainly less-stable carbonaceous species as confirmed by SEM, TPO, Raman and INS characterization. This study provides an in depth understanding of alloy effects in catalysts, the chemical nature of coked carbon on spent Ni-based catalysts and, hopefully, inspires the creative design of a new bimetallic catalyst for dry reforming reactions.

7.
J Mater Sci Mater Med ; 26(11): 258, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26449448

RESUMO

We have recently reported on the development of a biomimetic vein model to measure the performance of sclerosing foams. In this study we employed the model to compare the commercially-available Varithena(®) (polidocanol injectable foam) 1% varicose vein treatment (referred to as polidocanol endovenous microfoam, or PEM) with physician compounded foams (PCFs) made using different foam generation methods (Double Syringe System and Tessari methods) and different foam formulations [liquid to gas ratios of 1:3 or 1:7; gas mixtures composed of 100% CO2, various CO2:O2 mixtures and room air (RA)]. PCFs produced using the DSS method had longer dwell times (DTs) (range 0.54-2.21 s/cm in the 4 mm diameter vein model) than those of the corresponding PCFs produced by the Tessari technique (range 0.29-0.94 s/cm). PEM had the longest DT indicating the best cohesive stability of any of the foams produced (2.92 s/cm). Other biomimetic model variables investigated included effect of vessel size, delayed injection and rate of plug formation (injection speed). When comparing the 4 and 10 mm vessel diameters, the DTs seen in the 10 mm vessel were higher than those observed for the 4 mm vessel, as the vein angle had been reduced to 5° to allow for foam plug formation. PCF foam performance was in the order RA > CO2:O2 (35:65) ≅ CO2:O2 (65:35) > CO2; PEM had a longer DT than all PCFs (22.10 s/cm) except that for RA made by DSS which was similar but more variable. The effect of delayed injection was also investigated and the DT for PEM remained the longest of all foams with the lowest percentage deviation with respect to the mean values, indicating a consistent foam performance. When considering rate of plug formation, PEM consistently produced the longest DTs and this was possible even at low plug expansion rates (mean 29.5 mm/s, minimum 20.9 mm/s). The developed vein model has therefore demonstrated that PEM consistently displays higher foam stability and cohesiveness when compared to PCFs, over a range of clinically-relevant operational variables.


Assuntos
Biomimética , Modelos Biológicos , Veias
8.
Sensors (Basel) ; 14(8): 14806-38, 2014 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-25123465

RESUMO

An emerging demand for the precise manipulation of cells and particles for applications in cell biology and analytical chemistry has driven rapid development of ultrasonic manipulation technology. Compared to the other manipulation technologies, such as magnetic tweezing, dielectrophoresis and optical tweezing, ultrasonic manipulation has shown potential in a variety of applications, with its advantages of versatile, inexpensive and easy integration into microfluidic systems, maintenance of cell viability, and generation of sufficient forces to handle particles, cells and their agglomerates. This article briefly reviews current practice and reports our development of various ultrasonic standing wave manipulation devices, including simple devices integrated with high frequency (>20 MHz) ultrasonic transducers for the investigation of biological cells and complex ultrasonic transducer array systems to explore the feasibility of electronically controlled 2-D and 3-D manipulation. Piezoelectric and passive materials, fabrication techniques, characterization methods and possible applications are discussed. The behavior and performance of the devices have been investigated and predicted with computer simulations, and verified experimentally. Issues met during development are highlighted and discussed. To assist long term practical adoption, approaches to low-cost, wafer level batch-production and commercialization potential are also addressed.


Assuntos
Acústica/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Sobrevivência Celular/fisiologia , Simulação por Computador , Desenho de Equipamento/instrumentação , Microfluídica/instrumentação , Transdutores , Ultrassom/instrumentação
9.
J Nanobiotechnology ; 11: 20, 2013 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-23809777

RESUMO

BACKGROUND: In ultrasonic micro-devices, contrast agent micro-bubbles are known to initiate cavitation and streaming local to cells, potentially compromising cell viability. Here we investigate the effects of US alone by omitting contrast agent and monitoring cell viability under moderate-to-extreme ultrasound-related stimuli. RESULTS: Suspended H9c2 cardiac myoblasts were exposed to ultrasonic fields within a glass micro-capillary and their viability monitored under different US-related stimuli. An optimal injection flow rate of 2.6 mL/h was identified in which, high viability was maintained (~95%) and no mechanical stress towards cells was evident. This flow rate also allowed sufficient exposure of cells to US in order to induce bioeffects (~5 sec), whilst providing economical sample collection and processing times. Although the transducer temperature increased from ambient 23°C to 54°C at the maximum experimental voltage (29 Vpp), computational fluid dynamic simulations and controls (absence of US) revealed that the cell medium temperature did not exceed 34°C in the pressure nodal plane. Cells exposed to US amplitudes ranging from 0-29 Vpp, at a fixed frequency sweep period (tsw = 0.05 sec), revealed that viability was minimally affected up to ~15 Vpp. There was a ~17% reduction in viability at 21 Vpp, corresponding to the onset of Rayleigh-like streaming and a ~60% reduction at 29 Vpp, corresponding to increased streaming velocity or the potential onset of cavitation. At a fixed amplitude (29 Vpp) but with varying frequency sweep period (tsw = 0.02-0.50 sec), cell viability remained relatively constant at tsw ≥ 0.08 sec, whilst viability reduced at tsw < 0.08 sec and minimum viability recorded at tsw = 0.05 sec. CONCLUSION: The absence of CA has enabled us to investigate the effect of US alone on cell viability. Moderate-to-extreme US-related stimuli of cells have allowed us to discriminate between stimuli that maintain high viability and stimuli that significantly reduce cell viability. Results from this study may be of potential interest to researchers in the field of US-induced intracellular drug delivery and ultrasonic manipulation of biological cells.


Assuntos
Microfluídica/métodos , Miócitos Cardíacos/citologia , Ultrassom , Animais , Sobrevivência Celular , Oscilometria , Ratos , Reologia , Temperatura
10.
J Mater Sci Mater Med ; 24(6): 1417-23, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23512153

RESUMO

A novel analysis system for the quantification of sclerosing foam properties under clinically relevant conditions was developed with the purpose of establishing a robust methodology for comparative characterisation of different foam formulations and production strategies. The developed biomimetic-inspired model comprised of 4 or 10 mm inner diameter polytetrafluoroethylene tubing, filled with a blood substitute and fixed to a platform with an adjustable inclination angle. Sclerosing foams were produced by mixing polidocanol with either atmospheric air or 100 % CO2, using a double-syringe system method. Individual foams were injected into the tube, while videos were captured simultaneously. Videos were then transferred to an in-house computational foam analysis system (CFAS) which performed a sequence of semi-automated operations, allowing quantitative characterisation of sclerosing foam dynamic behaviour. Using CFAS, degradation rates of different foams were measured and the effect of gas composition, liquid sclerosant concentration and time delay between foam production and injection were evaluated.


Assuntos
Biomimética/instrumentação , Biomimética/métodos , Gases/uso terapêutico , Teste de Materiais/instrumentação , Reologia/instrumentação , Soluções Esclerosantes/química , Soluções Esclerosantes/uso terapêutico , Varizes/terapia , Desenho de Equipamento , Humanos , Varizes/fisiopatologia , Viscosidade
11.
J Acoust Soc Am ; 133(4): 1885-93, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23556558

RESUMO

A finite element based method is presented for calculating the acoustic radiation force on arbitrarily shaped elastic and fluid particles. Importantly for future applications, this development will permit the modeling of acoustic forces on complex structures such as biological cells, and the interactions between them and other bodies. The model is based on a non-viscous approximation, allowing the results from an efficient, numerical, linear scattering model to provide the basis for the second-order forces. Simulation times are of the order of a few seconds for an axi-symmetric structure. The model is verified against a range of existing analytical solutions (typical accuracy better than 0.1%), including those for cylinders, elastic spheres that are of significant size compared to the acoustic wavelength, and spheroidal particles.


Assuntos
Análise de Elementos Finitos , Modelos Teóricos , Som , Ultrassom , Simulação por Computador , Elasticidade , Desenho de Equipamento , Modelos Lineares , Movimento (Física) , Análise Numérica Assistida por Computador , Pressão , Espalhamento de Radiação , Fatores de Tempo , Ultrassom/instrumentação
12.
Biomed Microdevices ; 14(1): 153-63, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21987002

RESUMO

A microfluidic based device has been developed for the characterisation of embolisation behaviour with polyvinyl alcohol (PVA) hydrogel beads within a microchannel network with bifurcations which mimic the blood vessel network. Both distal and proximal embolisations were achieved within the PMMA-made microdevice exhibiting comparable embolisation characteristics with those observed in vivo. Results showed that small beads allowed more distal embolisations with a reduced control of the spatial location of occlusion sites. In contrast, large beads generated effective proximal embolisations with an improved reproducibility of embolisation performance. Embolic bead hydrodynamics, partitioning at bifurcations, penetration through microchannels and embolisation locations across the channel network were characterised by quantifying the effects of embolic bead size, bead concentration, channel geometry and fluidic conditions. This development provided further insights into the physical principles governing embolisation performances within the constructed microdevices allowing the improvement of the predictability and controllability of the clinical process outcomes. Furthermore, it can potentially provide a useful platform for preclinical research as an alternative to animal models, with an ultimate goal to reduce the amount of animal testing.


Assuntos
Biomimética , Embolização Terapêutica/instrumentação , Técnicas Analíticas Microfluídicas , Álcool de Polivinil/química , Humanos
13.
Nanotechnology ; 23(37): 375602, 2012 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-22922560

RESUMO

Microreactors have been shown to be a powerful tool for the production of nanoparticles (NPs); however, there is still a lack of understanding of the role that the microfluidic environment plays in directing the nanoprecipitation process. Here we investigate the mechanism of nanoprecipitation of block copolymer stabilized organic NPs using a microfluidic-based reactor in combination with computational fluid dynamics (CFD) modelling of the microfluidic implementation. The latter also accounts for the complex interplay between molecular and hydrodynamic phenomena during the nanoprecipitation process, in order to understand the hydrodynamics and its influence on the NP formation process. It is demonstrated that the competitive reactions result in the formation of two types of NPs, i.e., either with or without loading organic actives. The obtained results are interpreted by taking into consideration a new parameter representing the mismatching between the aggregations of the polymers and actives, which plays a decisive role in determining the size and polydispersity of the prepared hybrid NPs. These results expand the current understanding of the co-nanoprecipitation mechanism of active and block copolymer stabilizer, and on the role exerted by the microfluidic environment, giving information that could be translated to the emerging fields of microfluidic formation of NPs and nanomedicine.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Nanopartículas/química , Nanotecnologia/instrumentação , Poloxâmero/química , Precipitação Química , Desenho de Equipamento , Hidrodinâmica , Nanopartículas/ultraestrutura , beta Caroteno/química
14.
Ultrasound Med Biol ; 48(9): 1888-1898, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35798625

RESUMO

The aim of this research was to explore the interaction between ultrasound-activated microbubbles (MBs) and Pseudomonas aeruginosa biofilms, specifically the effects of MB concentration, ultrasound exposure and substrate properties on bactericidal efficacy. Biofilms were grown using a Centre for Disease Control (CDC) bioreactor on polypropylene or stainless-steel coupons as acoustic analogues for soft and hard tissue, respectively. Biofilms were treated with different concentrations of phospholipid-shelled MBs (107-108 MB/mL), a sub-inhibitory concentration of gentamicin (4 µg/mL) and 1-MHz ultrasound with a continuous or pulsed (100-kHz pulse repetition frequency, 25% duty cycle, 0.5-MPa peak-to-peak pressure) wave. The effect of repeated ultrasound exposure with intervals of either 15- or 60-min was also investigated. With polypropylene coupons, the greatest bactericidal effect was achieved with 2 × 5 min of pulsed ultrasound separated by 60 min and a microbubble concentration of 5 × 107 MBs/mL. A 0.76 log (83%) additional reduction in the number of bacteria was achieved compared with the use of an antibiotic alone. With stainless-steel coupons, a 67% (0.46 log) reduction was obtained under the same exposure conditions, possibly due to enhancement of a standing wave field which inhibited MB penetration in the biofilm. These findings demonstrate the importance of treatment parameter selection in antimicrobial applications of MBs and ultrasound in different tissue environments.


Assuntos
Microbolhas , Pseudomonas aeruginosa , Acústica , Antibacterianos/farmacologia , Biofilmes , Impedância Elétrica , Gentamicinas/farmacologia , Polipropilenos/farmacologia , Aço Inoxidável/farmacologia
15.
Top Curr Chem ; 304: 27-68, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21526435

RESUMO

Micromixing is a crucial process within microfluidic systems such as micro total analysis systems (µTAS). A state-of-art review on microstructured mixing devices and their mixing phenomena is given. The review first presents an overview of the characteristics of fluidic behavior at the microscale and their implications in microfluidic mixing processes. According to the two basic principles exploited to induce mixing at the microscale, micromixers are generally classified as being passive or active. Passive mixers solely rely on pumping energy, whereas active mixers rely on an external energy source to achieve mixing. Typical types of passive micromixers are discussed, including T- or Y-shaped, parallel lamination, sequential, focusing enhanced mixers, and droplet micromixers. Examples of active mixers using external forces such as pressure field, electrokinetic, dielectrophoretic, electrowetting, magneto-hydrodynamic, and ultrasound to assist mixing are presented. Finally, the advantages and disadvantages of mixing in a microfluidic environment are discussed.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Microfluídica/instrumentação , Microfluídica/métodos
16.
Sci Rep ; 9(1): 9880, 2019 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-31285447

RESUMO

Since the first reports on foam sclerotherapy, multiple studies have been conducted to determine the physical properties and behavior of foams, but relatively little is known about their biological effects on the endothelial cells lining the vessel wall. Moreover, a systematic comparison of the biological performance of foams produced with different methods has not been carried out yet. Herein, a 2D in vitro method was developed to compare efficacy of commercially available polidocanol injectable foam (PEM, Varithena) and physician-compounded foams (PCFs). Endothelial cell attachment upon treatment with foam was quantified as an indicator of therapeutic efficacy, and was correlated with foam physical characteristics and administration conditions. An ex vivo method was also developed to establish the disruption and permeabilisation of the endothelium caused by sclerosing agents. It relied on the quantitation of extravasated bovine serum albumin conjugated to Evans Blue, as an indicator of endothelial permeability. In our series of comparisons, PEM presented a greater overall efficacy compared to PCFs, across the different biological models, which was attributed to its drainage dynamics and gas formulation. This is consistent with earlier studies that indicated superior physical cohesiveness of PEM compared to PCFs.


Assuntos
Soluções Esclerosantes/farmacologia , Varizes/terapia , Aerossóis/farmacologia , Células Cultivadas , Células Endoteliais/efeitos dos fármacos , Células Endoteliais da Veia Umbilical Humana , Humanos , Modelos Biológicos , Permeabilidade , Polidocanol/farmacologia , Escleroterapia/métodos
17.
Sci Rep ; 9(1): 9789, 2019 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-31278312

RESUMO

Engineering tissue structures that mimic those found in vivo remains a challenge for modern biology. We demonstrate a new technique for engineering composite structures of cells comprising layers of heterogeneous cell types. An acoustofluidic bioreactor is used to assemble epithelial cells into a sheet-like structure. On transferring these cell sheets to a confluent layer of fibroblasts, the epithelial cells cover the fibroblast surface by collective migration maintaining distinct epithelial and fibroblast cell layers. The collective behaviour of the epithelium is dependent on the formation of cell-cell junctions during levitation and contrasts with the behaviour of mono-dispersed epithelial cells where cell-matrix interactions dominate and hinder formation of discrete cell layers. The multilayered tissue model is shown to form a polarised epithelial barrier and respond to apical challenge. The method is useful for engineering a wide range of layered tissue types and mechanistic studies on collective cell migration.


Assuntos
Engenharia Tecidual , Acústica , Animais , Biomarcadores , Reatores Biológicos , Adesão Celular , Impedância Elétrica , Células Epiteliais , Fibroblastos , Humanos
18.
Biomicrofluidics ; 13(1): 014112, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30867882

RESUMO

Ultrasonic standing wave systems have previously been used for the generation of 3D constructs for a range of cell types. In the present study, we cultured cells from the human hepatoma Huh7 cell line in a Bulk Acoustic Wave field and studied their viability, their functions, and their response to the anti-cancer drug, 5 Fluorouracil (5FU). We found that cells grown in the acoustofluidic bioreactor (AFB) expressed no reduction in viability up to 6 h of exposure compared to those cultured in a conventional 2D system. In addition, constructs created in the AFB and subsequently cultured outside of it had improved functionality including higher albumin and urea production than 2D or pellet cultures. The viability of Huh7 cells grown in the ultrasound field to 5FU anti-cancer drug was comparable to that of cells cultured in the 2D system, showing rapid diffusion into the aggregate core. We have shown that AFB formed 3D cell constructs have improved functionality over the conventional 2D monolayer and could be a promising model for anti-cancer drug testing.

19.
Artigo em Inglês | MEDLINE | ID: mdl-31165068

RESUMO

Foam sclerotherapy is clinically employed to treat varicose veins. It involves intravenous injection of foamed surfactant agents causing endothelial wall damage and vessel shrinkage, leading to subsequent neovascularization. Foam production methods used clinically include manual techniques, such as the Double Syringe System (DSS) and Tessari (TSS) methods. Pre-clinical in-vitro studies are conducted to characterize the performance of sclerosing agents; however, the experimental models used often do not replicate physiologically relevant physical and biological conditions. In this study, physical vein models (PVMs) were developed and employed for the first time to characterize the flow behavior of sclerosing foams. PVMs were fabricated in polydimethylsiloxane (PDMS) by replica molding, and were designed to mimic qualitative geometrical characteristics of veins. Foam behavior was investigated as a function of different physical variables, namely (i) geometry of the vein model (i.e., physiological vs. varicose vein), (ii) foam production technique, and (iii) flow rate of a blood surrogate. The experimental set-up consisted of a PVM positioned on an inclined platform, a syringe pump to control the flow rate of a blood substitute, and a pressure transducer. The static pressure of the blood surrogate at the PVM inlet was measured upon foam administration. The recorded pressure-time curves were analyzed to quantify metrics of foam behavior, with a particular focus on foam expansion and degradation dynamics. Results showed that DSS and TSS foams had similar expansion rate in the physiological PVM, whilst DSS foam had lower expansion rate in the varicose PVM compared to TSS foam. The degradation rate of DSS foam was lower than TSS foam, in both model architectures. Moreover, the background flow rate had a significant effect on foam behavior, enhancing foam displacement rate in both types of PVM.

20.
J Acoust Soc Am ; 124(4): 2042-52, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19062844

RESUMO

Sound reproduction via a noncontact surface mapping technique has great potential for sound archives, aiming to digitize content from early sound recordings such as wax cylinders, which may otherwise be "unplayable" with a stylus. If the noncontact techniques are to be considered a viable solution for sound archivists, a method for quantifying the quality of the reproduced signal needs to be developed. In this study, a specially produced test cylinder recording, encoded with sinusoids, provides the basis for the first quantitative analysis of signal reproduction from the noncontact full surface mapping method. The sampling and resolution of the measurement system are considered with respect to the requirements for digital archiving of cylinder recordings. Two different methods of audio signal estimation from a discrete groove cross section are described and rated in terms of signal-to-noise ratio and total harmonic distortion. Noncontact and stylus methods of sound reproduction are then compared using the same test cylinder. It is shown that noncontact methods appear to have distinct advantages over stylus reproduction, in terms of reduced harmonic distortion and lower frequency modulation.


Assuntos
Acústica , Modelos Teóricos , Processamento de Sinais Assistido por Computador , Espectrografia do Som , Som , Acústica/instrumentação , Arquivos , Simulação por Computador , Desenho de Equipamento , Análise de Fourier
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa