Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 131(9): 091801, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37721818

RESUMO

We measured the nuclear-recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a monoenergetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4 keV down to 100 eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100 eV. These results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.

2.
Phys Rev Lett ; 127(6): 061801, 2021 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-34420312

RESUMO

We present limits on spin-independent dark matter-nucleon interactions using a 10.6 g Si athermal phonon detector with a baseline energy resolution of σ_{E}=3.86±0.04(stat)_{-0.00}^{+0.19}(syst) eV. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matter particle masses from 93 to 140 MeV/c^{2}, with a raw exposure of 9.9 g d acquired at an above-ground facility. This work illustrates the scientific potential of detectors with athermal phonon sensors with eV-scale energy resolution for future dark matter searches.

3.
Phys Rev Lett ; 127(8): 081802, 2021 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-34477436

RESUMO

The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to lightly ionizing particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the vertical intensity of cosmogenically produced LIPs with an electric charge smaller than e/(3×10^{5}), as well as the strongest limits for charge ≤e/160, with a minimum vertical intensity of 1.36×10^{-7} cm^{-2} s^{-1} sr^{-1} at charge e/160. These results apply over a wide range of LIP masses (5 MeV/c^{2} to 100 TeV/c^{2}) and cover a wide range of ßγ values (0.1-10^{6}), thus excluding nonrelativistic LIPs with ßγ as small as 0.1 for the first time.

4.
Phys Rev Lett ; 112(24): 241302, 2014 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-24996080

RESUMO

We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg days was analyzed for WIMPs with mass <30 GeV/c(2), with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2×10(-42) cm(2) at 8 GeV/c(2). This result is in tension with WIMP interpretations of recent experiments and probes new parameter space for WIMP-nucleon scattering for WIMP masses <6 GeV/c(2).

5.
Med J Aust ; 169(7): 385-6, 1998 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-9803253

RESUMO

Congenital cataracts can cause irreversible loss of sight unless surgery is performed soon after birth. In the case reported here an obstetric ultrasound detected congenital cataracts in an otherwise normal fetus without any history of familial syndrome, infection or metabolic disorder. The lens opacity was detectable on transabdominal ultrasound at 18 weeks' gestation and the appearance was unchanged near-term. An otherwise normal boy was delivered at term and underwent surgery in the first week of life. Prenatal detection of the cataracts by means of high quality obstetric ultrasound facilitated early surgery and preservation of sight.


Assuntos
Catarata/congênito , Ultrassonografia Pré-Natal , Adulto , Catarata/diagnóstico por imagem , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Cristalino/diagnóstico por imagem , Masculino , Gravidez
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa