Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Klin Monbl Augenheilkd ; 233(2): 148-53, 2016 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-26878730

RESUMO

BACKGROUND: The goal of glaucoma treatment is to maintain the patient's visual function and related quality of life, at a sustainable cost. In this review, methods of measuring quality of life are presented, together with their impact in clinical practice. METHODS: Searches were from the inception of the database to date. Electronic databases searched included Medline (Ovid), Medline In-Process (Ovid), and Embase (Ovid). In a semistructured approach, the articles were checked for their eligibility to provide information about the measurement and application of quality of life in glaucoma patients. RESULTS: Well established questionnaires are available to measure quality of life in glaucoma patients, as well as instruments to measure benefits. Performance-based measures are more time-consuming. The Glaucoma Activity Limitation-9 Questionnaire (GAL-9) is a glaucoma-specific questionnaire in German, with a Rasch analysis. In eye diseases with central visual field defects, it is the better eye that determines the patient's quality of life, whereas in glaucoma patients with peripheral defects, it is the worse eye that has a stronger influence. Structural changes in glaucoma are less well correlated with quality of life than are functional impairments. There have been a few initial reports of patterns of visual field defects that correlate with subjective impairments. CONCLUSIONS: The data can help to improve our understanding of individual patient impairment and support our efforts to improve the medical advice and therapy that these patients receive.


Assuntos
Glaucoma/diagnóstico , Glaucoma/psicologia , Indicadores Básicos de Saúde , Psicometria/métodos , Qualidade de Vida/psicologia , Nível de Saúde , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Inquéritos e Questionários
2.
Ophthalmologie ; 119(6): 599-604, 2022 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-34860282

RESUMO

PURPOSE: The quality of life (QoL) of glaucoma patients is affected by many factors. In particular, patient activity is compromised by the chronicity of the disease. In this study, we evaluated the change in QoL and its impact on activities over a period of 8 years. METHODS: A total of 43 patients with glaucomatous optic nerve damage were enrolled in this retrospective longitudinal observational study. Changes in intraocular pressure (IOP), best-corrected visual acuity (BCVA) and visual field (VF) parameters, number of IOP-lowering eye drops and IOP-lowering surgery were assessed over a period of 8 years. Assessment of QoL was obtained by patient-reported visual functioning using the Rasch-calibrated glaucoma activity limitation 9 (GAL-9) questionnaire at baseline and after 8 years. RESULTS: The BCVA of the better eye changed from 0.16 ± 0.22 to 0.21 ± 0.14 logMAR, whereas there was a change from 0.27 ± 0.25 to 1.39 ± 1.1 logMAR in the worse eye. The VF parameter mean deviation (MD) of the better eye changed from -2.39 ± 4.55 dB to -4.83 ± 5.09 dB, while it altered significantly from -8.86 ± 5.86 dB to -12.05 ± 8.07 dB in the worse eye. Values of GAL­9 changed from -2.39 ± 2.14 to -1.38 ± 2.78 (in the Rasch analysis, more negative values account for a better QoL), according to a sum score change from 79.17 ± 19.63 to 69.22 ± 27.95. This change showed a highly significant correlation with the MD at follow-up, especially with the worse eye (r = 0.43). The impact of the MD at follow-up on QoL could also be well predicted in a regression model. CONCLUSION: The QoL of glaucoma patients decreased significantly over time. Changes in the VF, particularly of the worse eye, have a great impact on reported functioning. Careful treatment, especially of the eye with greater glaucomatous damage, is mandatory.


Assuntos
Glaucoma , Qualidade de Vida , Humanos , Pressão Intraocular , Estudos Retrospectivos , Campos Visuais
3.
Klin Monbl Augenheilkd ; 228(10): 892-9, 2011 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-21432767

RESUMO

BACKGROUND: Light-induced oxidative stress is an suggested reason for retinal pigment epithelium (RPE) degeneration in age-related macular degeneration (AMD). This study investigates the influence of light on intracellular reactive oxygen species (ROS) and apoptosis in the human RPE and potential cytoprotective effects of the tetracycline antibiotic minocycline. METHODS: Primary human RPE cells were either pre- or post-incubated with minocycline and then exposed to white light or oxidative stress (600 µM, H(2)O(2)). Then viability, induction of intracellular reactive oxygen species (ROS), apoptosis and cell death was determined. Expression of apoptotic BAX and anti-apoptotic Bcl-2 protein and their mRNA were determined by RT-PCR and Western blot analysis. RESULTS: Both light exposure and oxidative stress decreased RPE cell viability and Bcl-2 expression and increased intracellular ROS, apoptotic cell death, and BAX expression. Minocycline reduced these effects under certain conditions. CONCLUSIONS: This study demonstrates that minocycline effectively protects human RPE cells against oxidative damage. However, in the light of minocycline's photosensitising properties its potential role in AMD treatment needs further evaluation.


Assuntos
Antibacterianos/uso terapêutico , Citoproteção/efeitos dos fármacos , Degeneração Macular/tratamento farmacológico , Degeneração Macular/fisiopatologia , Minociclina/uso terapêutico , Antibacterianos/efeitos adversos , Apoptose/efeitos dos fármacos , Apoptose/fisiologia , Western Blotting , Morte Celular/efeitos dos fármacos , Morte Celular/fisiologia , Proliferação de Células , Células Cultivadas/efeitos dos fármacos , Humanos , Luz/efeitos adversos , Degeneração Macular/diagnóstico , Degeneração Macular/genética , Minociclina/efeitos adversos , Epitélio Pigmentado Ocular/efeitos dos fármacos , Epitélio Pigmentado Ocular/fisiopatologia , Proteínas Proto-Oncogênicas c-bcl-2/genética , RNA Mensageiro/genética , Espécies Reativas de Oxigênio/metabolismo , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Proteína X Associada a bcl-2/genética
4.
Klin Monbl Augenheilkd ; 226(5): 396-403, 2009 May.
Artigo em Alemão | MEDLINE | ID: mdl-19507086

RESUMO

OBJECTIVE: The aim of this study is to provide the best available evidence on how to disinfect contact Goldman tonometers. METHODS: A systematic review of all articles on disinfection of contact tonometers was conducted. Articles published up to July 2008 were identified in Medline, Embase and references from included articles. Two observers participated in the data retrieval and assessment of the studies identified. RESULTS: A total of 89 articles was retrieved, of which 58 could be included. Of those, 18 were clinical studies, 17 experimental microbiological studies, 8 expert assessments or guidelines and 15 reviews, surveys, descriptions of new methods. The clinical studies illustrate the importance of the problem, possible side effects of some disinfection methods but yield inconclusive results regarding efficacy. Experimental studies investigated a variety of bacterial and virological questions as well as material damage by disinfection. Both chlorine-based and hydrogen peroxide-based liquid disinfection were shown to be effective if applied for 5 min. Inconsistent results exist for alcohol wipes and UV disinfection - material damage has been described for both. The US guidelines and most expert recommendations are supported by evidence of the existing data. CONCLUSIONS: Chlorine-based and hydrogen peroxide-based liquid disinfections for 5 minutes are effective and relatively safe for disinfecting contact tonometers.


Assuntos
Desinfecção/instrumentação , Desinfecção/métodos , Contaminação de Equipamentos/prevenção & controle , Tonometria Ocular/instrumentação
5.
Ophthalmologe ; 115(8): 670-675, 2018 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-28900712

RESUMO

BACKGROUND: The STARflo Glaucoma Device (iSTAR Medical, Wavre, Belgium) offers a new approach to bleb-free filtering surgery in which the intraocular pressure (IOP) is lowered by supporting outflow of the aqueous humor into the suprachoroidal space. MATERIALS AND METHODS: On the basis of a case series of 9 patients with open-angle glaucoma (OAG) unmanageable by drug-based treatment, intra- and postoperative experiences with the implant are presented. The implant, the implantation procedure, and the first results 6 months postoperatively are described. RESULTS: No intraoperative complications were observed. Postoperative complications such as increased astigmatism or ocular hypotony were rare and transient. After 6 months there was an IOP reduction from 29.1 mm Hg ± 6.1 mm Hg with 2.7 ± 1.1 local IOP-lowering medications to 16.1 ± 4.1 mm Hg (IOP reduction of 44.7%) with additional 2.0 ± 0.8 local IOP-lowering medications. DISCUSSION: The new STARflo Glaucoma Device shows promising results in reducing the IOP of medically uncontrolled OAG. Further investigations concerning the long-time efficacy of the implant and additional IOP-lowering medication are still ongoing.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Drenagem , Glaucoma/cirurgia , Humanos , Pressão Intraocular , Tonometria Ocular , Resultado do Tratamento
6.
Ophthalmology ; 113(12): 2176-80, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16996598

RESUMO

PURPOSE: Cost-utility and cost-effectiveness analyses are of increasing importance to clinicians and health policy experts. This study determines the costs in Germany and other countries in relation to gain of utility for patients with bilateral poor vision owing to corneal disease undergoing penetrating keratoplasty (PK) in 1 eye. DESIGN: A cost-utility analysis was performed using retrospective clinical data and high-level evidence-based data. PARTICIPANTS: Sixty patients (mean age, 46.3 years) with bilateral poor vision who underwent PK for corneal disease. METHODS: Visual acuity and utility values were obtained before and 1 year after PK and after suture removal. A 10-year graft survival rate of 80% was assumed. Expenses included costs for the corneal transplant and surgery, medication, and optical rehabilitation. A discount rate of 5% was applied for costs and quality-adjusted life years (QALYs). Cost-utility analysis encompassed a 10-year period after surgery. MAIN OUTCOME MEASURES: The number of QALYs was calculated for the study group undergoing PK. This was divided into the cost of the procedure to get the number of euros spent per QALY gained. RESULTS: Median binocular preoperative visual acuity was -log mean angle of resolution (-logMAR) 0.91+/-0.53 (Snellen equivalent 20/160) yielding a utility value of 0.67. After suture removal and optical rehabilitation, binocular visual acuity increased to median -logMAR 0.36+/-0.36 (20/46) with a utility value of 0.79. Over the 10 years after surgery and considering graft survival and discounting, a cost utility of 9551 euros per QALY was gained (equivalent to US11,557 dollars). One-way sensitivity analysis yielded a range from 7706 euros to 12874 euros per QALY, highlighting the robustness of the model. CONCLUSIONS: Although an expensive procedure, PK is cost effective in patients with bilateral poor vision.


Assuntos
Custos de Cuidados de Saúde , Ceratoplastia Penetrante/economia , Anos de Vida Ajustados por Qualidade de Vida , Transtornos da Visão/economia , Visão Binocular , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças da Córnea/economia , Efeitos Psicossociais da Doença , Análise Custo-Benefício , Feminino , Pesquisa sobre Serviços de Saúde/economia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acuidade Visual
7.
Circ Res ; 87(9): 825-30, 2000 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-11055988

RESUMO

Both cGMP-dependent and -independent mechanisms have been implicated in the regulation of vascular tone by NO. We analyzed acetylcholine (ACh)- and NO-induced relaxation in pressurized small arteries and aortic rings from wild-type (wt) and cGMP kinase I-deficient (cGKI(-/-)) mice. Low concentrations of NO and ACh decreased the spontaneous myogenic tone in wt but not in cGKI(-/-) arteries. However, contractions of cGKI(-/-) arteries and aortic rings were reduced by high concentrations (10 micromol/L) of 2-(N:, N-diethylamino)-diazenolate-2-oxide (DEA-NO). Iberiotoxin, a specific blocker of Ca(2+)-activated K(+) (BK(Ca)) channels, only partially prevented the relaxation induced by DEA-NO or ACh in pressurized vessels and aortic rings. DEA-NO increased the activity of BK(Ca) channels only in vascular smooth muscle cells isolated from wt cGKI(+/+) mice. These results suggest that low physiological concentrations of NO decrease vascular tone through activation of cGKI, whereas high concentrations of DEA-NO relax vascular smooth muscle independent of cGKI and BK(Ca). NO-stimulated, cGKI-independent relaxation was antagonized by the inhibition of soluble guanylyl cyclase or cAMP kinase (cAK). DEA-NO increased cGMP to levels that are sufficient to activate cAK. cAMP-dependent relaxation was unperturbed in cGKI(-/-) vessels. In conclusion, low concentrations of NO relax vessels by activation of cGKI, whereas in the absence of cGKI, NO can relax small and large vessels by cGMP-dependent activation of cAK.


Assuntos
Proteínas Quinases Dependentes de GMP Cíclico/deficiência , GMP Cíclico/farmacologia , Músculo Liso Vascular/efeitos dos fármacos , Óxido Nítrico/farmacologia , Vasodilatação/efeitos dos fármacos , Acetilcolina , Animais , Aorta , AMP Cíclico/análise , GMP Cíclico/análise , Hidrazinas , Técnicas In Vitro , Masculino , Camundongos , Músculo Liso Vascular/enzimologia , Óxidos de Nitrogênio , Peptídeos/farmacologia
8.
Ophthalmologe ; 103(6): 493-500, 2006 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-16763866

RESUMO

PURPOSE: Value-based medicine (VBM) unifies costs and patient-perceived value (improvement in quality of life, length of life, or both) of an intervention. Value-based ophthalmology is of increasing importance for decisions in eye care. METHODS: The methods of VBM are explained and definitions for a specific terminology in this field are given. The cost-utility analysis as part of health care economic analyses is explained. RESULTS: VBM exceeds evidence-based medicine by incorporating parameters of cost and benefits from an ophthalmological intervention. The benefit of the intervention is defined as an increase or maintenance of visual quality of life and can be determined by utility analysis. The time trade-off method is valid and reliable for utility analysis. The resources expended for the value gained in VBM are measured with cost-utility analysis in terms of cost per quality-adjusted life years gained (euros/QALY). Numerous cost-utility analyses of different ophthalmological interventions have been published. CONCLUSION: The fundamental instrument of VBM is cost-utility analysis. The results in cost per QALY allow estimation of cost effectiveness of an ophthalmological intervention. Using the time trade-off method for utility analysis allows the comparison of ophthalmological cost-utility analyses with those of other medical interventions. VBM is important for individual medical decision making and for general health care.


Assuntos
Atenção à Saúde/economia , Oftalmopatias/economia , Modelos Econômicos , Oftalmologia/economia , Oftalmologia/métodos , Garantia da Qualidade dos Cuidados de Saúde/economia , Garantia da Qualidade dos Cuidados de Saúde/métodos , Comportamento do Consumidor , Efeitos Psicossociais da Doença , Análise Custo-Benefício/economia , Análise Custo-Benefício/métodos , Custos e Análise de Custo , Técnicas de Apoio para a Decisão , Alemanha
9.
Ophthalmologe ; 103(2): 109-13, 2006 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-16078065

RESUMO

PURPOSE: To date, the increase of visual acuity and morphological parameters have been used to assess the benefit of a surgical intervention. The aim of this prospective study was to evaluate changes in patients' visual quality of life due to vitreoretinal surgery for epiretinal membranes. PATIENTS AND METHODS: Twenty patients with unilateral epiretinal membrane and good visual acuity of the fellow eye were included. Best corrected visual acuity and visual quality of life assessed by the visual function index (VF-14) were obtained preoperatively and 3 months after pars plana vitrectomy and peeling. RESULTS: Median visual acuity increased from 0.28 to 0.4 postoperatively. Visual quality of life (VF-14 values) rose from 72.8+/-4.7 (SEM) to 83.3+/-2.9 (p<0.05). Analysis revealed that patients with preoperatively low VF-14 values and preoperatively low visual acuity notably profited from surgery. The increase of visual quality of life can be predicted better than increase of visual acuity. Combined cataract surgery had no significant influence. CONCLUSION: In addition to best corrected visual acuity, quality of life measurements are important predictive and outcome parameters to estimate the value of vitreoretinal surgery.


Assuntos
Membrana Epirretiniana/diagnóstico , Membrana Epirretiniana/cirurgia , Avaliação de Resultados em Cuidados de Saúde/métodos , Qualidade de Vida , Transtornos da Visão/diagnóstico , Transtornos da Visão/prevenção & controle , Vitrectomia , Idoso , Membrana Epirretiniana/complicações , Feminino , Humanos , Masculino , Recuperação de Função Fisiológica , Resultado do Tratamento , Transtornos da Visão/etiologia
10.
Ophthalmologe ; 113(6): 469-77, 2016 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-27222127

RESUMO

BACKGROUND: Smart Data means intelligent data accumulation and the evaluation of large data sets. This is particularly important in ophthalmology as more and more data are being created. Increasing knowledge and personalized therapies are expected by combining clinical data from electronic health records (EHR) with measurement data. OBJECTIVE: In this study we investigated the possibilities to consolidate data from measurement devices and clinical data in a data warehouse (DW). MATERIAL AND METHODS: An EHR was adjusted to the needs of ophthalmology and the contents of referral letters were extracted. The data were imported into a DW overnight. Measuring devices were connected to the EHR by an HL7 standard interface and the use of a picture archiving and communications system (PACS). Data were exported from the review software using a self-developed software. For data analysis the software was modified to the specific requirements of ophthalmology. RESULTS: In the EHR 12 graphical user interfaces were created and the data from 32,234 referral letters were extracted. A total of 23 diagnostic devices could be linked to the PACS and 85,114 optical coherence tomography (OCT) scans, 19,098 measurements from IOLMaster as well as 5,425 pentacam examinations were imported into the DW including over 300,000 patients. Data discovery software was modified providing filtering methods. CONCLUSION: By building a DW a foundation for clinical and epidemiological studies could be implemented. In the future, decision support systems and strategies for personalized therapies can be based on such a database.


Assuntos
Conjuntos de Dados como Assunto/estatística & dados numéricos , Registros Eletrônicos de Saúde/estatística & dados numéricos , Oftalmopatias/diagnóstico , Oftalmopatias/epidemiologia , Armazenamento e Recuperação da Informação/métodos , Sistemas de Informação em Radiologia/estatística & dados numéricos , Sistema de Registros/estatística & dados numéricos , Alemanha/epidemiologia , Humanos , Registro Médico Coordenado/métodos , Prevalência , Fatores de Risco
11.
Ophthalmologe ; 102(2): 158-62, 2005 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-15290200

RESUMO

PURPOSE: The aim of this study was to evaluate patients' acceptance and intraocular pressure (IOP) readings of a new digital mobile tonometer (TGDc-01) and compare it to Goldmann applanation tonometry. METHOD: Measurements repeated five times with the TGDc-01 and three times with Goldmann tonometry were performed in 100 eyes of 100 patients by two independent investigators. Patients' acceptance of both techniques was evaluated by a visual analogue scale (VAS). RESULTS: The mean IOP with the TGDc-01 yielded 15.4 mmHg for investigator 1 and 12.7 mmHg for investigator 2 (range: 4-43 mmHg). Results of the measurements with Goldmann tonometry showed 17.6 mmHg for investigator 1 and 17.3 mmHg for investigator 2 (9-42 mmHg). The IOP difference of the two tonometry methods was highly significant (p<0.001). The intraobserver variability was 29% for investigator 1 and 8% for investigator 2. Mean IOP values of the two investigators taken with the TGDc-01 differed significantly (p<0.01) from each other by a mean of 2.6 mmHg. CONCLUSIONS: The new mobile tonometer TGDc-01 is better accepted by patients but IOP values are significantly lower compared to Goldmann tonometry and variability is high. Regarding glaucoma diagnostics it seems to be less suitable than Goldmann tonometry.


Assuntos
Análise de Falha de Equipamento , Glaucoma/diagnóstico , Pressão Intraocular , Aceitação pelo Paciente de Cuidados de Saúde , Tonometria Ocular/instrumentação , Transtornos da Visão/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Glaucoma/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Miniaturização , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tonometria Ocular/métodos , Transtornos da Visão/etiologia
12.
Ophthalmologe ; 100(12): 1091-7, 2003 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-14704825

RESUMO

BACKGROUND: The assessment of patient's quality of life is not only of vital importance for clinical trials of new therapies but also becomes more and more implemented into daily clinical therapeutical decisions. METHODS: Different methods for evaluating quality of life are available. A well-known questionnaire for measuring global quality of life is the Short Form 36 (SF 36). However, in ophthalmology more specific instruments for measuring visual quality of life are needed. We review the usefulness of specific questionnaires such as the Visual Function 14 (VF-14) or the National Eye Institute Visual Function Questionnaire (NEI-VFQ) in their application to common ophthalmologic diseases such as cataract, age-related macular degeneration and glaucoma. Studies applying these methods were identified by a search in the Medline database. RESULTS: Several instruments to measure visual life quality in ophthalmologic patients are available. Internal consistency and validity are shown. CONCLUSIONS: Evaluating visual quality of life is an important parameter for assessing ophthalmologic diseases and the value of different therapies. It is an important outcome variable in clinical studies. Furthermore, individual visual quality of life should be considered in individual therapeutic decisions and helps to assess the economic effect of current and new therapies.


Assuntos
Oftalmopatias , Oftalmologia , Qualidade de Vida , Inquéritos e Questionários , Visão Ocular , Idoso , Extração de Catarata , Transplante de Córnea , Glaucoma , Humanos , Degeneração Macular , Doenças Retinianas , Acuidade Visual
14.
Ophthalmologe ; 111(3): 241-6, 2014 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-23604252

RESUMO

BACKGROUND: Goldmann applanation tonometry (GAT) is still the gold standard for measuring the intraocular pressure (IOP). Usually fluorescein eye drops are used additional to topical anesthesia to gain the best visualization results. The present study evaluated the differences in the results of GAT with and without fluorescein. METHODS: A total of 400 eyes of 200 patients without known glaucoma were enrolled in this study and randomized to two groups: group A (first measurement without, second measurement with fluorescein) and group B (first measurement with fluorescein, second without). All measurements were performed by the same examiner with the same slit lamp. Results were analyzed by Bland-Altman plots and Spearman's correlation test. RESULTS: The examined groups showed no significant differences regarding patient age, astigmatism or reason for consulting. In both groups performing GAT without the application of fluorescein led to significantly lower measurement results. The differences were 1.5 ± 1.7 mmHg SD in group A, 1.2 ± 1.6 mmHg SD in group B and 1.4 ± 1.65 mmHg SD for all eyes. The intraocular pressure (IOP) and the differences between the groups were independent of patient age, astigmatism, reason of consulting or IOP level. Both groups showed outliers up to 10 mmHg difference because of corneal edema. CONCLUSIONS: Measurements from GAT without fluorescein differed significantly from measurements with fluorescein, independently of patient age, astigmatism, reason for consulting or IOP level. The mean difference of 1.4 mmHg may seem negligible in daily routine but can lead to serious consequences in borderline cases.


Assuntos
Fluoresceína , Pressão Intraocular/fisiologia , Manometria/métodos , Feminino , Corantes Fluorescentes , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Ophthalmologe ; 111(8): 791-802, 2014 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-25092025

RESUMO

Screening is a strategy used in a systematic approach to identify an unrecognized disease or risk factors in individuals in a population without signs or symptoms. The test characteristics (specificity and sensitivity) and the prevalence of the disease are of vital importance for the achievable quality of prediction. Multidimensional decision-making must not only consider the benefits of screening but also its potential disadvantages, such as overtreatment, diagnostics of unclear findings and the psychological impact on healthy individuals. Besides medical, ethical and test theoretical considerations, economic considerations also have to be included in decision-making on a screening program. In Germany, a nationwide screening for diabetic retinopathy and regional programs for amblyopia screening exist. Screening for glaucoma or age-related macular degeneration is currently not funded by the statutory health insurance.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Oftalmopatias/diagnóstico , Oftalmopatias/prevenção & controle , Programas de Rastreamento/métodos , Programas de Rastreamento/organização & administração , Oftalmologia/organização & administração , Diagnóstico Precoce , Alemanha , Humanos
16.
Ophthalmologe ; 111(5): 420-7, 2014 May.
Artigo em Alemão | MEDLINE | ID: mdl-24838862

RESUMO

BACKGROUND: Eye diseases that are relevant regarding their macroeconomic costs and their impact on society include cataract, diabetic retinopathy, age-related maculopathy, glaucoma and refractive errors. OBJECTIVES: The aim of this article is to provide a comprehensive overview of direct and indirect costs for major eye disease categories for Germany, based on existing literature and data sources. METHODS: A semi-structured literature search was performed in the databases Medline and Embase and in the search machine Google for relevant original papers and reviews on costs of eye diseases with relevance for or transferability to Germany (last research date October 2013). In addition, manual searching was performed in important national databases and information sources, such as the Federal Office of Statistics and scientific societies. RESULTS: The direct costs for these diseases add up to approximately 2.6 billion Euros yearly for the Federal Republic of Germany, including out of the pocket payments from patients but excluding optical aids (e.g. glasses). In addition to those direct costs there are also indirect costs which are caused e.g. by loss of employment or productivity or by a reduction in health-related quality of life. These indirect costs can only be roughly estimated. Including the indirect costs for the eye diseases investigated, a total yearly macroeconomic cost ranging between 4 and 12 billion Euros is estimated for Germany. CONCLUSION: The costs for the eye diseases cataract, diabetic retinopathy, age-related maculopathy, glaucoma and refractive errors have a macroeconomic relevant dimension. Based on the predicted demographic changes with an ageing society an increase of the prevalence and thus also an increase of costs for eye diseases is expected in the future.


Assuntos
Efeitos Psicossociais da Doença , Oftalmopatias/economia , Custos de Cuidados de Saúde/estatística & dados numéricos , Gastos em Saúde/estatística & dados numéricos , Renda/estatística & dados numéricos , Oftalmologia/estatística & dados numéricos , Desemprego/estatística & dados numéricos , União Europeia , Oftalmopatias/epidemiologia , Alemanha/epidemiologia , Avaliação do Impacto na Saúde , Humanos , Modelos Econômicos , Prevalência , Perfil de Impacto da Doença
17.
Ophthalmologe ; 109(7): 692-8, 2012 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-22532038

RESUMO

PURPOSE: The aim of this study was to investigate the accuracy of a navigated laser photocoagulator in clinically significant macular edema (CSME). METHODS: Focal laser treatment for diabetic macular edema (DME) in 36 patients was digitally planned on fundus images and performed with navigation using NAVILAS® (OD-OS, Teltow, Germany). Treatment intensity was controlled visually during treatment so the laser spots applied were barely directly visible after treatment. Using color images (CI) and optical coherence tomography (OCT) 4,137 laser spots (mean 115 per eye) were analyzed at 1 month follow-up and accuracy of spot placement was determined. RESULTS: In total 79% of laser spots were visible on CI of which 96% were within 100 µm of the planned target position. On an intention-to-treat (ITT) basis, 76% of the laser spots were placed and visible within the 100 µm target and OCT confirmed that laser effects were limited to the outer retina. The mean time for focal treatment was < 7 min (±3 min). CONCLUSIONS: After NAVILAS treatment for DME a high percentage of laser effects could be visualized on post-treatment color images and the location showed high concordance with the preplanning target.


Assuntos
Retinopatia Diabética/diagnóstico , Retinopatia Diabética/cirurgia , Fotocoagulação a Laser/instrumentação , Fotocoagulação a Laser/métodos , Edema Macular/diagnóstico , Edema Macular/cirurgia , Retinopatia Diabética/complicações , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Edema Macular/etiologia , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
18.
Ophthalmologe ; 108(10): 939-46, 2011 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-21779960

RESUMO

INTRODUCTION: Glaucoma is one of the leading causes of irreversible blindness worldwide and can have a significant impact on patient quality of life and vision-related functioning. The Glaucoma Quality of Life 15 (GQL-15) questionnaire is a disease-specific instrument to evaluate and quantify functional impairment of patients with glaucoma. This study evaluated the German version of the GQL-15 including correlations with perimetric parameters. METHODS: A German version of the GQL-15 containing 15 items was developed and evaluated in 98 patients with glaucoma in different stages of the disease. The GQL-15 results were correlated with the perimetric parameters mean deviation (MD) and pattern standard deviation (PSD) of the better and worse eye. Classical and probabilistic test analyses (Rasch model) were performed. RESULTS: The mean GQL-15 value was 77.3 ± 21.7 (SD) and most items of the GQL-15 correlated significantly with the MD of the worse eye (r = -0.416; p = 0.0014) and the better eye (r = -0.304; p = 0.02). There was also a highly significant correlation between glaucoma-specific QoL and visual acuity. A short version containing nine items yielding a higher psychometric performance can also be used. CONCLUSIONS: The German version of the GQL-15 is a potent instrument to evaluate impairment in vision-specific functioning of patients with glaucoma. The GQL-15 values are better correlated with the sensitivity of the eye with the more severe glaucomatous damage. The data can help for a better understanding of individual patient impairment to improve medical advice and therapy of patients with glaucoma.


Assuntos
Glaucoma/complicações , Glaucoma/diagnóstico , Perfil de Impacto da Doença , Inquéritos e Questionários , Transtornos da Visão/diagnóstico , Transtornos da Visão/etiologia , Idoso , Feminino , Alemanha , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto , Testes Visuais
19.
Ophthalmologe ; 108(2): 117-23, 2011 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-20683601

RESUMO

OBJECTIVE: The aim of the study was to compare the diagnostic properties of a non-mydriatic 200° ultra-widefield scanning laser ophthalmoscope (SLO) with mydriatic ETDRS 7-field fundus photography for diabetic retinopathy screening. METHODS: A consecutive series of 66 eyes from 34 patients with different levels of diabetic retinopathy (DR) were examined. Grading of DR and macular edema (ME) obtained from mydriatic ETDRS 7-field fundus photography were compared with grading obtained from Optomap Panoramic 200MA SLO images. All SLOs were performed with an undilated pupil and no additional clinical information was used for evaluation of images by two independent, masked experts. RESULTS: A total of 14 eyes from ETDRS 7-field fundus photography and 11 eyes from Optomap could not be graded by at least one grader due to poor image quality, yielding 48 eyes for comparison purposes. Of the 48 ETDRS 7-field fundus photographs, 9 (11 for grader 2) eyes had no or mild DR (ETDRS levels ≤20) and 17 (23 for grader 2) eyes had no ME. Agreement of Optomap retinopathy grading with ETDRS 7-field fundus photography was good, kappa 0.70 for grader 1 and kappa 0.66 for grader 2. There was good agreement between both techniques for ME, grader 1 kappa 0.68 and grader 2 kappa 0.74. CONCLUSIONS: Grading of DR levels from Optomap Panoramic 200MA non-mydriatic images showed a good correlation with mydriatic ETDRS 7-field fundus photography. Both techniques are of sufficient quality for a valid assessment of DR. Optomap Panoramic 200MA images cover a larger retinal area and might therefore offer additional diagnostic properties.


Assuntos
Retinopatia Diabética/patologia , Angiofluoresceinografia/instrumentação , Microscopia Confocal/instrumentação , Fotografação/instrumentação , Retinoscópios , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Ophthalmologe ; 108(5): 445-51, 2011 May.
Artigo em Alemão | MEDLINE | ID: mdl-21253747

RESUMO

BACKGROUND: Cumulative light exposure is significantly associated with progression of age-related macular degeneration (AMD). Inhibition of vascular endothelial growth factor A (VEGF) is the main target of current antiangiogenic treatment strategies for AMD. Previous reports indicated that sorafenib, an oral multikinase inhibitor, might have beneficial effects on exudative AMD. This study investigates the effects of sorafenib on light-induced overexpression of VEGF and its receptors VEGFR1 and 2 in human retinal pigment epithelial (RPE) cells. METHODS: The effects of sorafenib on VEGFR1 and 2 expression of primary human RPE cells was investigated by reverse transcription polymerase chain reaction (RT-PCR), immunohistochemistry and western blotting. In addition, RPE cells were exposed to white light and incubated with sorafenib. Viability, expression of VEGF and its mRNA were determined by RT-PCR, immunohistochemistry, western blotting, and enzyme-linked immunosorbent assays. RESULTS: Sorafenib reduced VEGFR1 and 2 expression of RPE cells. Light exposure decreased cell viability and increased expression and secretion of VEGF. These light-induced effects were significantly reduced when cells were treated with sorafenib at a dose of 1 µg/ml. CONCLUSION: The results show that sorafenib has promising properties as a potential antiangiogenic treatment for AMD.


Assuntos
Benzenossulfonatos/farmacologia , Piridinas/farmacologia , Epitélio Pigmentado da Retina/efeitos dos fármacos , Epitélio Pigmentado da Retina/metabolismo , Receptor 1 de Fatores de Crescimento do Endotélio Vascular/metabolismo , Receptor 2 de Fatores de Crescimento do Endotélio Vascular/metabolismo , Adulto , Inibidores da Angiogênese/farmacologia , Citoproteção/efeitos dos fármacos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Niacinamida/análogos & derivados , Compostos de Fenilureia , Inibidores de Proteínas Quinases/farmacologia , Sorafenibe , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa