Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Ultrasound Med ; 40(2): 341-350, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32710577

RESUMO

OBJECTIVES: Handheld ultrasound devices (HUDs) have previously been limited to grayscale imaging without options for left ventricle (LV) quantification. We aimed to study the feasibility and reliability of automatic measurements of mitral annular plane systolic excursion (MAPSE) by HUDs. METHODS: An algorithm that automatically measured MAPSE from live grayscale recordings was implemented in a HUD. Twenty patients at a university hospital were examined by either a cardiologist or a sonographer. Standard echocardiography using a high-end scanner was performed. The apical 4-chamber view was recorded 4 times by both echocardiography and the HUD. MAPSE was measured by M-mode and color tissue Doppler (cTD) during echocardiography and automatically by the HUD. RESULTS: The automatic method underestimated mean MAPSE ± SD versus M-mode (9.6 ± 2.2 versus 10.9 ± 2.6 mm; difference, 1.2 ± 1.4 mm, P < .005). The difference between the automatic and cTD measurements was not significant (0.8 ± 1.8 mm; P = .073). The intraclass correlation coefficients (ICCs) between automatic and M-mode measurements was 0.85, and 0.81 for cTD measurements. There was good agreement between the methods, and the intra- and inter-rater ICCs were excellent for all methods (≥0.86). CONCLUSIONS: In this novel study evaluating automatic quantification of LV longitudinal function by HUD, we showed the high feasibility and reliability of the method. Compared to M-mode imaging, the automatic method underestimated MAPSE by 8% to 10%, but the difference with cTD imaging was nonsignificant. We conclude that this study's method for automatic quantitative assessment of LV function can be integrated in HUDs.


Assuntos
Disfunção Ventricular Esquerda , Estudos de Viabilidade , Humanos , Valva Mitral/diagnóstico por imagem , Projetos Piloto , Reprodutibilidade dos Testes , Sístole
2.
J Ultrasound Med ; 39(12): 2313-2323, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32436616

RESUMO

OBJECTIVES: To study the feasibility and accuracy of focused echocardiography by nurses supported by near-real-time interpretation via telemedicine by an experienced cardiologist. METHODS: Fifty consecutive patients were included from an outpatient heart failure (HF) clinic. Limited echocardiography was performed by 1 of 3 specialized nurses. The echocardiograms were transferred by a secure transfer model for near-real-time interpretation to 1 out-of-hospital cardiologist, assessing, among others, the left ventricular (LV) internal diameter, end-diastolic volume, ejection fraction, left atrial (LA) indexed end-systolic volume, mitral early inflow velocity (E), the ratio of E to mitral late inflow, and the ratio of E to the mitral annular early diastolic velocity. The reference method was echocardiography by 1 of 4 experienced cardiologists. RESULTS: The median age of the population (46% women) was 79 (range, 33-95) years. The assessment and quantification of LA and LV dimensions, volumes, and functional indices were feasible in 94% or more via the telemedical approach. The agreement with reference measurements was very high by the telemedical approach. The mean duration ± SD of the complete telemedical approach from the start of echocardiography until the cardiologist's report was received by the caregiving nurse was 1.32 ± 0.36 (range, 1.58) hours. The correlations with reference to the above-specified indices were r = 0.75 to 0.94. CONCLUSIONS: Limited echocardiography by nurses in an outpatient heart failure clinic, supported by interpretation by an out-of-hospital cardiologist, was feasible and reliable. This may reduce geographic disparities and allow more patients to benefit from the advantages of implementing focused echocardiography by noncardiologists in diagnostics and follow-up.


Assuntos
Insuficiência Cardíaca , Telemedicina , Disfunção Ventricular Esquerda , Adulto , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Volume Sistólico , Função Ventricular Esquerda
3.
Eur Heart J Imaging Methods Pract ; 2(1): qyad047, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39045176

RESUMO

Aims: To evaluate whether the characteristics of patients, operators, and image quality could explain the accuracy of heart failure (HF) diagnostics by general practitioners (GPs) using handheld ultrasound devices (HUDs) with automatic decision-support software and telemedical support. Methods and results: Patients referred to an outpatient cardiac clinic due to symptoms indicating HF were examined by one of five GPs after dedicated training. In total, 166 patients were included [median (inter-quartile range) age 73 (63-78) years; mean ± standard deviation ejection fraction 53 ± 10%]. The GPs considered whether the patients had HF in four diagnostic steps: (i) clinical examination, (ii) adding focused cardiac HUD examination, (iii) adding automatic decision-support software measuring mitral annular plane systolic excursion (autoMAPSE) and ejection fraction (autoEF), and (iv) adding telemedical support. Overall, the characteristics of patients, operators, and image quality explained little of the diagnostic accuracy. Except for atrial fibrillation [lower accuracy for HUD alone and after adding autoEF (P < 0.05)], no patient characteristics influenced the accuracy. Some differences between operators were found after adding autoMAPSE (P < 0.05). Acquisition errors of the four-chamber view and a poor visualization of the mitral plane were associated with reduced accuracy after telemedical support (P < 0.05). Conclusion: The characteristics of patients, operators, and image quality explained just minor parts of the modest accuracy of GPs' HF diagnostics using HUDs with and without decision-support software. Atrial fibrillation and not well-standardized recordings challenged the diagnostic accuracy. However, the accuracy was only modest in well-recorded images, indicating a need for refinement of the technology.

4.
Ultrasound Med Biol ; 49(5): 1137-1144, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36804210

RESUMO

Early and correct heart failure (HF) diagnosis is essential to improvement of patient care. We aimed to evaluate the clinical influence of handheld ultrasound device (HUD) examinations by general practitioners (GPs) in patients with suspected HF with or without the use of automatic measurement of left ventricular (LV) ejection fraction (autoEF), mitral annular plane systolic excursion (autoMAPSE) and telemedical support. Five GPs with limited ultrasound experience examined 166 patients with suspected HF (median interquartile range = 70 (63-78) y; mean ± SD EF = 53 ± 10%). They first performed a clinical examination. Second, they added an examination with HUD, automatic quantification tools and, finally, telemedical support by an external cardiologist. At all stages, the GPs considered whether the patients had HF. The final diagnosis was made by one of five cardiologists using medical history and clinical evaluation including a standard echocardiography. Compared with the cardiologists' decision, the GPs correctly classified 54% by clinical evaluation. The proportion increased to 71% after adding HUDs, and to 74 % after telemedical evaluation. Net reclassification improvement was highest for HUD with telemedicine. There was no significant benefit of the automatic tools (p ≥ 0.58). Addition of HUD and telemedicine improved the GPs' diagnostic precision in suspected HF. Automatic LV quantification added no benefit. Refined algorithms and more training may be needed before inexperienced users benefit from automatic quantification of cardiac function by HUDs.


Assuntos
Insuficiência Cardíaca , Telemedicina , Humanos , Ultrassonografia , Ecocardiografia , Função Ventricular Esquerda , Insuficiência Cardíaca/diagnóstico por imagem , Volume Sistólico
5.
BMJ Open ; 12(10): e063793, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-36229153

RESUMO

OBJECTIVES: To evaluate the feasibility and reliability of hand-held ultrasound (HUD) examinations with real-time automatic decision-making software for ejection fraction (autoEF) and mitral annular plane systolic excursion (autoMAPSE) by novices (general practitioners), intermediate users (registered cardiac nurses) and expert users (cardiologists), respectively, compared to reference echocardiography by cardiologists in an outpatient cohort with suspected heart failure (HF). DESIGN: Feasibility study of a diagnostic test. SETTING AND PARTICIPANTS: 166 patients with suspected HF underwent HUD examinations with autoEF and autoMAPSE measurements by five novices, three intermediate-skilled users and five experts. HUD results were compared with a reference echocardiography by experts. A blinded cardiologist scored all HUD recordings with automatic measurements as (1) discard, (2) accept, but adjust the measurement or (3) accept the measurement as it is. PRIMARY OUTCOME MEASURE: The feasibility of automatic decision-making software for quantification of left ventricular function. RESULTS: The users were able to run autoEF and autoMAPSE in most patients. The feasibility for obtaining accepted images (score of ≥2) with automatic measurements ranged from 50% to 91%. The feasibility was lowest for novices and highest for experts for both autoEF and autoMAPSE (p≤0.001). Large coefficients of variation and wide coefficients of repeatability indicate moderate agreement. The corresponding intraclass correlations (ICC) were moderate to good (ICC 0.51-0.85) for intra-rater and poor (ICC 0.35-0.51) for inter-rater analyses. The findings of modest to poor agreement and reliability were not explained by the experience of the users alone. CONCLUSION: Novices, intermediate and expert users were able to record four-chamber views for automatic assessment of autoEF and autoMAPSE using HUD devices. The modest feasibility, agreement and reliability suggest this should not be implemented into clinical practice without further refinement and clinical evaluation. TRIAL REGISTRATION NUMBER: NCT03547076.


Assuntos
Cardiologistas , Clínicos Gerais , Insuficiência Cardíaca , Testes Diagnósticos de Rotina , Estudos de Viabilidade , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes , Função Ventricular Esquerda
6.
J Clin Endocrinol Metab ; 103(2): 740-747, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-29165598

RESUMO

Context: Metformin is used in an attempt to reduce pregnancy complications associated with polycystic ovary syndrome (PCOS). Little is known about the effect of metformin on fetal development and growth. Objectives: To compare the effect of metformin versus placebo on fetal growth and birth anthropometrics in PCOS offspring compared with a reference population in relation to maternal body mass index (BMI). Design: Post hoc analysis of a randomized controlled trial. Setting: Double-blind, placebo-controlled, multicenter study. Patients: 258 offspring born to mothers with PCOS. Intervention: 2000 mg metformin (n = 131) or placebo (n = 121) from first trimester to delivery. Main Outcome Measures: Mean abdominal diameter and biparietal diameter (BPD) at gestational weeks 19 and 32. Head circumference (HC), birth length, and weight related to a reference population of healthy offspring, expressed as gestational age- and sex-adjusted z-scores. Results: Metformin- versus placebo-exposed offspring had larger heads at gestational week 32 (BPD, 86.1 mm versus 85.2 mm; P = 0.03) and at birth (HC, 35.6 cm versus 35.1 cm; P < 0.01). Analyses stratified by maternal prepregnancy BMI, larger heads were observed only among offspring of overweight/obese mothers. Among normal-weight mothers, the effect of metformin compared with placebo was reduced length (z-score = -0.96 versus -0.42, P = 0.04) and weight (z-score = -0.44 versus 0.02; P = 0.03). Compared with the reference population, offspring born to PCOS mothers (placebo group) had reduced length (z-score = -0.40; 95% confidence interval, -0.60 to -0.40), but similar birth weight and HC. Conclusions: Metformin exposure resulted in larger head size in offspring of overweight mothers, traceable already in utero. Maternal prepregnancy BMI modified the effect of metformin on offspring anthropometrics. Anthropometrics of offspring born to PCOS mothers differed from those of the reference population.


Assuntos
Peso ao Nascer/efeitos dos fármacos , Desenvolvimento Fetal/efeitos dos fármacos , Metformina/uso terapêutico , Síndrome do Ovário Policístico/tratamento farmacológico , Complicações na Gravidez/tratamento farmacológico , Efeitos Tardios da Exposição Pré-Natal/induzido quimicamente , Adulto , Método Duplo-Cego , Feminino , Humanos , Recém-Nascido , Mães , Gravidez , Efeitos Tardios da Exposição Pré-Natal/fisiopatologia , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa