Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Med Educ ; 23(1): 713, 2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37770858

RESUMO

BACKGROUNDS: Medical education has shifted from passive forms of teaching to more active learning strategies, particularly in response to the COVID-19 pandemic. Research has discussed the challenges and disadvantages associated with online education, but there is limited documentation on physicians' perceptions of this sudden and unexpected transformation in medical education. This study aimed to determine the effect of online interactive visual learning on physicians' perceptions of the effectiveness and their satisfaction with this online learning experience. METHODS: We routinely recruited 64 unclassified physicians in the hospital's postgraduate year (PGY) program between September 2021 and April 2022. PGY physicians received an online interactive visual learning course. Online (Google Form) testing and questionnaires before and after this course evaluated learning performance, learning attitude and satisfaction of these physicians. RESULTS: The interactive online learning tools facilitated the physicians' active learning processes by reducing their learning burden (burden vs. no burden: 4.69% vs. 68.75%) and increasing their learning interest (interest vs. no interest: 84.38% vs. 3.12%) in the online format. Post-test scores were significantly improved compared with pretest scores (post-test vs. pre-test: 5 vs. 4; p < 0.05) and their imaging recognition was markedly improved from baseline (post-test vs. pre-test: 85.19% vs. 61.11%). Levels of satisfaction correlated positively with the physicians' learning burden (rs = 0.541), learning interest (rs = 0.562), and perceived benefits of imaging recognition (post-course: rs = 0.508; future: rs = 0.563) (all p < 0.05). CONCLUSIONS: Our online course with interactive visual learning facilitated PGY physicians' learning performance, levels of satisfaction, interest, and perceived benefits of online learning. Hospitals and policymakers need to be aware that this learning approach can markedly enhance physicians' academic outcomes and levels of clinical practice.


Assuntos
COVID-19 , Educação a Distância , Médicos , Humanos , Educação a Distância/métodos , Taiwan , Pandemias , COVID-19/epidemiologia , Satisfação Pessoal
2.
Biosensors (Basel) ; 13(12)2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38131767

RESUMO

Portal hypertension-related complications pose a significant risk for liver failure post-transplantation. Thus, accurate monitoring of intraoperative portal venous pressure (PVP) is crucial. However, current PVP monitoring techniques requiring direct percutaneous puncture carry the risk of graft damage. In this study, we present an innovative non-puncture PVP monitoring device (PVPMD) using a 3D-printed prototype. PVPMD design is inspired by the sphygmomanometer principle, and strategically encompasses the portal vein and enables precise PVP measurement through blood flow ultrasonography after temporary occlusion. By a series of mini-pig experiments, the prototype PVPMD demonstrated a strong correlation with invasive catheter measurements in the main trunk of the portal vein (rs = 0.923, p = 0.000). There was a significant repeatability and reproducibility between the prototype PVPMD- and invasive catheter-measured PVP. This indicates that the PVPMD holds immense potential for direct application in liver transplantation and surgery. Moreover, it has the potential to replace catheter-based central venous pressure (CVP) measurements, thereby mitigating catheter-related complications during many surgeries. In conclusion, our innovative device represents a significant advancement in PVP monitoring during liver transplantation, with comprehensive validation from principle exploration to successful animal experiments. We anticipate that this groundbreaking PVPMD will attract the attention of researchers and clinicians, propelling the noninvasive measurement of PVP or other venous/arterial pressures into a new era of clinical practice.


Assuntos
Hipertensão , Transplante de Fígado , Animais , Suínos , Transplante de Fígado/métodos , Pressão na Veia Porta/fisiologia , Reprodutibilidade dos Testes , Porco Miniatura , Punções
3.
Diagnostics (Basel) ; 10(5)2020 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-32380731

RESUMO

Alterations in the switching defective/sucrose non-fermenting (SWI/SNF) chromatin-remodeling complex are enriched in advanced thyroid cancer. Integrase interactor 1 (INI1), encoded by the SMARCB1 gene on the long arm of chromosome 22, is one of the core subunits of the SWI/SNF complex. INI1 immunohistochemistry is frequently used for the diagnosis of malignant rhabdoid neoplasms. In the present study, we found normal and benign thyroid tissues generally had diffusely intense nuclear immunostaining. Loss of INI1 immunohistochemical expression was observed in 8% of papillary thyroid cancer and 30% of follicular thyroid cancer. Furthermore, loss of INI1 expression was associated with extrathyroidal extension (p < 0.001) and lymph node metastasis (p = 0.038). Analysis of The Cancer Genome Atlas database revealed that SMARCB1 underexpression was associated with the follicular variant subtype and aneuploidy in papillary thyroid cancer. We speculate that SMARCB1 is an important effector in addition to NF2 and CHEK2 inactivation among thyroid cancers with chromosome 22q loss.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa