1.
Artif Organs ; 26(2): 200-8, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11879250

RESUMO

The aim of this study was to prepare a DNA immunoadsorbent for the specific, extracorporeal removal of anti-DNA antibodies from the blood of patients with systemic lupus erythematosus (SLE) and rheumatoid arthritis (RA). Two kinds of cellulose beads were applied as a carrier. Calf thymus DNA was covalently coupled to the carrier using the epichlorohydrin method. Efforts were focused on optimization of conditions for activation and coupling, trying to couple as much DNA as possible to a certain amount of carrier. It was found that the activation level increased with the increase of NaOH concentration and the amount of epichlorohydrin used. The mole of epichlorohydrin must be in excess of that of NaOH because excess NaOH could react further with the epoxy groups in the beads resulting in a decrease of activation level. High activation level could be obtained in a medium of 3.0 M NaOH. The DNA coupling was found to be mainly temperature and pH dependent. Using 0.1 M Tris-HCl buffer, pH 8 at a temperature of 50-90 degrees C, more than 3 mg of DNA could be coupled to 1 ml of wet beads. Prolonging the coupling reaction under 50 degrees C to 72 h resulted in the same coupling capacity as that obtained under 90 degrees C. To evaluate the adsorption ability for anti-DNA of this immunoadsorbent, batch and circulation tests were applied using SLE patient plasma. The immunoadsorbents showed excellent adsorption capacity, especially the cellulose with smaller size (200-300 microm). The incubation of 20 ml of patient's plasma with 1 ml of adsorbent resulted in an 80% decline in the anti-DNA antibody level. In the circulation tests, 30 ml of plasma was circulated through a column containing 3 ml of adsorbent. The maximum decline in anti-DNA level, 80%, was obtained after 60 min. Such high adsorption capacity and high adsorption rate suggest this immunoadsorbent may be used for treatment. For comparison, 1,4-butanediol diglycidyl ether activation method and other DNA sources were tested with the same protocol.


Assuntos
Artrite Reumatoide/terapia , Celulose , Imunoadsorventes , Lúpus Eritematoso Sistêmico/terapia , Adsorção , DNA/imunologia , Humanos , Tamanho da Partícula , Sefarose/uso terapêutico
2.
Artif Organs ; 26(2): 124-32, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11879240

RESUMO

The principle of a patient-specific immunoadsorber (PsIA) is demonstrated. Studies with model systems (HSA/anti-HSA) on immobilization, stability, and leakage form the basis for the presented fast-performance liquid chromatography (FPLC) and batch experiments, which were conducted using two different protein A adsorbers and autologous and heterologous PsIA systems. Experiments to determine the binding capacity of protein A adsorbers and PsIAs are described. In all experiments, the adsorption of plasma IgG, total protein, and C1q and C3d circulating immune complexes were measured. Plasma of patients with autoimmune diseases (rheumatoid arthritis, systemic lupus erythematosus) was investigated. Analysis was performed in both the initial plasma and the flow-through or supernatant. Results of the investigations using FPLC and batch experiments were compared. Autologous PsIA systems are suitable for the selective removal of elevated levels of circulating immune complexes in the plasma.


Assuntos
Complexo Antígeno-Anticorpo/sangue , Remoção de Componentes Sanguíneos , Técnicas de Imunoadsorção , Imunoadsorventes , Cromatografia Líquida , Humanos , Imunoglobulina G
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa