Eur J Clin Microbiol Infect Dis ; 35(9): 1463-8, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27259712

RESUMO

Epidemic clones of Acinetobacter baumannii, described as European clones I, II, and III, are associated with hospital epidemics throughout the world. We aimed to determine the molecular characteristics and genetic diversity between European clones I, II, and III from Turkey and Azerbaijan. In this study, a total of 112 bloodstream isolates of carbapenem-resistant Acinetobacter spp. were collected from 11 hospitals across Turkey and Azerbaijan. The identification of Acinetobacter spp. using conventional and sensitivity tests was performed by standard criteria. Multiplex polymerase chain reaction (PCR) was used to detect OXA carbapenemase-encoding genes (bla OXA-23-like, bla OXA-24-like, bla OXA-51-like, and bla OXA-58-like). Pulsed-field gel electrophoresis (PFGE) typing was used to investigate genetic diversity. The bla OXA-51-like gene was present in all 112 isolates, 75 (67 %) carried bla OXA-23-like, 7 (6.2 %) carried bla OXA-58-like genes, and 5 (4.5 %) carried bla OXA-24-like genes. With a 90 % similarity cut-off value, 15 clones and eight unique isolates were identified. The largest clone was cluster D, with six subtypes. Isolates from clusters D and I were widely spread in seven different geographical regions throughout Turkey. However, F cluster was found in the northern and eastern regions of Turkey. EU clone I was grouped within J cluster with three isolates found in Antalya, Istanbul, and Erzurum. EU clone II was grouped in the U cluster with 15 isolates and found in Kayseri and Diyarbakir. The bla OXA-24-like gene in carbapenemases was identified rarely in Turkey and has been reported for the first time from Azerbaijan. Furthermore, this is the first multicenter study in Turkey and Azerbaijan to identify several major clusters belonging to European clones I and II of A. baumannii.


Assuntos
Infecções por Acinetobacter/epidemiologia , Infecções por Acinetobacter/microbiologia , Acinetobacter baumannii/efeitos dos fármacos , Antibacterianos/farmacologia , Carbapenêmicos/farmacologia , Resistência beta-Lactâmica , Acinetobacter baumannii/classificação , Acinetobacter baumannii/genética , Acinetobacter baumannii/isolamento & purificação , Azerbaijão/epidemiologia , Análise por Conglomerados , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/microbiologia , Eletroforese em Gel de Campo Pulsado , Variação Genética , Genótipo , Hospitais , Humanos , Testes de Sensibilidade Microbiana , Epidemiologia Molecular , Tipagem Molecular , Reação em Cadeia da Polimerase Multiplex , Turquia/epidemiologia , beta-Lactamases/genética
2.
J Clin Monit Comput ; 30(6): 985-994, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26563187

RESUMO

Increased extravascular lung water (EVLW) may contribute to respiratory failure in neonates. Accurate measurement of EVLW in these patients is limited due to the lack of bedside methods. The aim of this pilot study was to investigate the reliability of the transpulmonary ultrasound dilution (TPUD) technique as a possible method for estimating EVLW in a neonatal animal model. Pulmonary edema was induced in 11 lambs by repeated surfactant lavages. In between the lavages, EVLW indexed by bodyweight was estimated by TPUD (EVLWItpud) and transpulmonary dye dilution (EVLWItpdd) (n = 22). Final EVLWItpud measurements were also compared with EVLWI estimations by gold standard post mortem gravimetry (EVLWIgrav) (n = 6). EVLWI was also measured in two additional lambs without pulmonary edema. Bland-Altman plots showed a mean bias between EVLWItpud and EVLWItpdd of -3.4 mL/kg (LOA ± 25.8 mL/kg) and between EVLWItpud and EVLWIgrav of 1.7 mL/kg (LOA ± 8.3 mL/kg). The percentage errors were 109 and 43 % respectively. The correlation between changes in EVLW measured by TPUD and TPDD was r2 = 0.22. Agreement between EVLWI measurements by TPUD and TPDD was low. Trending ability to detect changes between these two methods in EVLWI was questionable. The accuracy of EVLWItpud was good compared to the gold standard gravimetric method but the TPUD lacked precision in its current prototype. Based on these limited data, we believe that TPUD has potential for future use to estimate EVLW after adaptation of the algorithm. Larger studies are needed to support our findings.


Assuntos
Água Extravascular Pulmonar , Termodiluição/métodos , Algoritmos , Animais , Débito Cardíaco , Cateterismo , Artéria Femoral/patologia , Hemodinâmica , Lesão Pulmonar/patologia , Edema Pulmonar/terapia , Reprodutibilidade dos Testes , Ovinos , Termogravimetria , Ultrassonografia
3.
Br J Anaesth ; 108(3): 409-16, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22171359

RESUMO

BACKGROUND: Cardiac output (CO) monitoring remains complex in newborns as most of the current technologies fail to accurately measure systemic blood flow in the presence of shunts. We validated CO measurements using transpulmonary ultrasound dilution (TPUD) in a neonatal lamb model with a left-to-right shunt. METHODS: Regular arterial and central venous catheters were inserted into seven lambs (3.5-8.3 kg). A surgically constructed left-to-right aorto-pulmonary Gore-Tex(®) shunt was intermittently opened and closed, while CO was manipulated by creating haemorrhagic hypotension. CO measurements with TPUD (COtpud) were compared with those obtained by an ultrasonic transit-time flow probe positioned around the main pulmonary artery (COufp). RESULTS: We performed 72 sessions of three paired CO measurements. The mean COufp was 1.00 litre min(-1) (range 0.47-1.75 litre min(-1)) and mean COtpud 1.05 litre min(-1) (range 0.54-1.87 litre min(-1)). With an open shunt, the mean Qp/Qs ratio was 1.8 (range 1.3-2.6). A comparison between COufp and COtpud showed a mean bias (sd) of 0.03 (0.09) and 0.07 (0.10) litre min(-1), respectively, for measurements with a closed and an open shunt. The percentage error was 18% and 20% for measurements with a closed and an open shunt. Polar plot analysis showed good trending ability for both closed and open shunt groups. CONCLUSIONS: TPUD is a reliable technology to measure CO in the presence of a left-to-right shunt.


Assuntos
Débito Cardíaco/fisiologia , Permeabilidade do Canal Arterial/diagnóstico por imagem , Técnicas de Diluição do Indicador , Animais , Animais Recém-Nascidos , Cateterismo Cardíaco/métodos , Modelos Animais de Doenças , Permeabilidade do Canal Arterial/fisiopatologia , Estudos de Viabilidade , Modelos Animais , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Fluxo Sanguíneo Regional/fisiologia , Carneiro Doméstico , Ultrassonografia
4.
Br J Anaesth ; 109(6): 870-8, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22907338

RESUMO

BACKGROUND: Transpulmonary ultrasound dilution (TPUD) is a promising method for cardiac output (CO) measurement in severely ill neonates. The incidence of lung injury in this population is high, which might influence CO measurement using TPUD because of altered lung perfusion. We evaluated the influence of lung injury on the accuracy and precision of CO measurement using TPUD in an animal model. METHODS: In nine neonatal lambs, central venous and arterial catheters were inserted and connected to the TPUD monitor. Repeated lavages with warmed isotonic saline were performed to gradually induce lung injury. CO measurements with TPUD (COtpud) were compared with those obtained by an ultrasonic transit-time flow probe around the main pulmonary artery (COufp). An increase in oxygenation index was used as an indicator of induced lung injury during the experiment. Post-mortem lung injury was confirmed by histopathological examination. RESULTS: Fifty-five sessions of three paired CO measurements were analysed. The mean COufp was 1.53 litre min(-1) (range 0.66-2.35 litre min(-1)), and the mean COtpud was 1.65 litre min(-1) (range 0.78-2.91 litre min(-1)). The mean bias (standard deviation) between the two methods was 0.13 (0.15) litre min(-1) with limits of agreement of ±0.29 litre min(-1). The overall percentage error was 19.1%. The accuracy and precision did not change significantly during progressive lung injury. Histopathological severity scores were consistent with heterogeneous lung injury. The capability to track changes in CO using TPUD was moderate to good. CONCLUSIONS: The accuracy and precision of CO measurement using TPUD is not influenced in the presence of heterogeneous lung injury in an animal model.


Assuntos
Débito Cardíaco , Lesão Pulmonar/veterinária , Monitorização Fisiológica/métodos , Monitorização Fisiológica/veterinária , Ultrassonografia/veterinária , Animais , Animais Recém-Nascidos , Cateterismo Venoso Central/instrumentação , Cateterismo Venoso Central/veterinária , Cateterismo Periférico/instrumentação , Cateterismo Periférico/veterinária , Modelos Animais de Doenças , Técnicas de Diluição do Indicador/instrumentação , Técnicas de Diluição do Indicador/veterinária , Lesão Pulmonar/fisiopatologia , Artéria Pulmonar/fisiopatologia , Reprodutibilidade dos Testes , Carneiro Doméstico , Ultrassonografia/instrumentação
5.
Pract Lab Med ; 31: e00291, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35860389

RESUMO

Explaining hypoglycaemia, especially in patients without diabetes mellitus, is challenging. Here we present a case, where the added value for clinical diagnosis of insulin determination with liquid chromatography-mass spectrometry (LC-MS/MS) is shown. By the use of LC-MS/MS the different insulin analogues can be identified. The confirmation of an insulin analogue present during hypoglycaemia facilitated in our case the discussion with the patient and his family about what happened.

6.
Br J Anaesth ; 107(3): 336-43, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21642643

RESUMO

BACKGROUND: The transpulmonary thermodilution (TPTD) technique for measuring cardiac output (CO) has never been validated in the presence of a left-to-right shunt. METHODS: In this experimental, paediatric animal model, nine lambs with a surgically constructed aorta-pulmonary left-to-right shunt were studied under various haemodynamic conditions. CO was measured with closed and open shunt using the TPTD technique (CO(TPTD)) with central venous injections of ice-cold saline. An ultrasound transit time perivascular flow probe around the main pulmonary artery served as the standard reference measurement (CO(MPA)). RESULTS: Seven lambs were eligible for further analysis. Mean (sd) weight was 6.6 (1.6) kg. The mean CO(MPA) was 1.21 litre min(-1) (range 0.61-2.06 l min(-1)) with closed shunt and 0.93 litre min(-1) (range 0.48-1.45 litre min(-1)) with open shunt. The open shunt resulted in a mean Q(p)/Q(s) ratio of 1.8 (range 1.6-2.4). The bias between the two CO methods was 0.17 litre min(-1) [limits of agreement (LOA) of 0.27 litre min(-1)] with closed shunt and 0.14 litre min(-1) (LOA of 0.32 litre min(-1)) with open shunt. The percentage errors were 22% with closed shunt and 34% with open shunt. The correlation (r) between the two methods was 0.93 (P<0.001) with closed shunt and 0.86 (P<0.001) with open shunt. The correlation (r) between the two methods in tracking changes in CO (ΔCO) during the whole experiment was 0.94 (P<0.0001). CONCLUSIONS: The TPTD technique is a feasible method of measuring CO in paediatric animals with a left-to-right shunt.


Assuntos
Débito Cardíaco , Cardiopatias Congênitas/fisiopatologia , Termodiluição/métodos , Animais , Aorta/fisiologia , Modelos Animais de Doenças , Circulação Pulmonar , Ovinos , Choque Hemorrágico/fisiopatologia
7.
Antimicrob Resist Infect Control ; 10(1): 31, 2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-33546759

RESUMO

BACKGROUND: Central line-associated bloodstream infections (CLABSI) are a main focus of infection prevention and control initiatives in neonatal care. Standardised surveillance of neonatal CLABSI enables intra- and interfacility comparisons which can contribute to quality improvement. To date, there is no national registration system for CLABSI in neonatal care in the Netherlands and several criteria are used for local monitoring of CLABSI incidence rates. To achieve standardised CLABSI surveillance we conducted a consensus procedure with regard to nationwide neonatal CLABSI surveillance criteria (SC). METHODS: A modified Delphi consensus procedure for the development of nationwide neonatal CLABSI SC was performed between January 2016 and January 2017 in the Netherlands. An expert panel was formed by members of the Working Group on Neonatal Infectious Diseases of the Section of Neonatology of the Dutch Paediatric Society. The consensus procedure consisted of three expert panel rounds. RESULTS: The expert panel achieved consensus on Dutch neonatal CLABSI SC. Neonatal CLABSI is defined as a bloodstream infection occurring more than 72 h after birth, associated with an indwelling central venous or arterial line and laboratory confirmed by one or more blood cultures. In addition, the blood culture finding should not be related to an infection at another site and one of the following criteria can be applied: 1. a bacterial or fungal pathogen is identified from one or more blood cultures; 2. the patient has clinical symptoms of sepsis and 2A) a common commensal is identified in two separate blood cultures or 2B) a common commensal is identified by one blood culture and C-reactive protein level is above 10 mg/L in the first 36 h following blood culture collection. CONCLUSIONS: The newly developed Dutch neonatal CLABSI SC are concise, specified to the neonatal population and comply with a single blood culture policy in actual neonatal clinical practice. International agreement upon neonatal CLABSI SC is needed to identify best practices for infection prevention and control.


Assuntos
Infecções Relacionadas a Cateter/diagnóstico , Cateterismo Venoso Central , Consenso , Técnica Delphi , Humanos , Recém-Nascido , Controle de Infecções , Países Baixos , Sepse/diagnóstico
8.
J Hosp Infect ; 105(4): 686-690, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32339616

RESUMO

In the Netherlands, the PREZIES surveillance is used for registration and surveillance of central venous catheter (CVC) -related bloodstream infections (CRBSI). We investigated how this Dutch definition correlated with internationally used definitions for CRBSI, central line-associated bloodstream infections (CLABSI) and mucosal barrier injury laboratory-confirmed bloodstream infections (MBI-LCBI). We determined that the Dutch PREZIES definition of CRBSI is appropriate for surveillance control of CVC care bundle use in haemato-oncology patients managed with multi-lumen CVCs.


Assuntos
Infecções Relacionadas a Cateter/microbiologia , Cateterismo Venoso Central/efeitos adversos , Monitoramento Epidemiológico , Neoplasias Hematológicas/complicações , Sepse/microbiologia , Adulto , Idoso , Infecções Relacionadas a Cateter/etiologia , Feminino , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Estudos Retrospectivos , Sepse/etiologia
9.
Sci Rep ; 10(1): 2619, 2020 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-32060342

RESUMO

We observed an increase in methicillin-susceptible Staphylococcus aureus (MSSA) infections at a Dutch neonatal intensive care unit. Weekly neonatal MSSA carriage surveillance and cross-sectional screenings of health care workers (HCWs) were available for outbreak tracing. Traditional clustering of MSSA isolates by spa typing and Multiple-Locus Variable number tandem repeat Analysis (MLVA) suggested that nosocomial transmission had contributed to the infections. We investigated whether whole-genome sequencing (WGS) of MSSA surveillance would provide additional evidence for transmission. MSSA isolates from neonatal infections, carriage surveillance, and HCWs were subjected to WGS and bioinformatic analysis for identification and localization of high-quality single nucleotide polymorphisms, and in-depth analysis of subsets of isolates. By measuring the genetic diversity in background surveillance, we defined transmission-level relatedness and identified isolates that had been unjustly assigned to clusters based on MLVA, while spa typing was concordant but of insufficient resolution. Detailing particular subsets of isolates provided evidence that HCWs were involved in multiple outbreaks, yet it alleviated concerns about one particular HCW. The improved resolution and accuracy of genomic outbreak analyses substantially altered the view on outbreaks, along with apposite measures. Therefore, inclusion of the circulating background population has the potential to overcome current issues in genomic outbreak inference.


Assuntos
Infecção Hospitalar/epidemiologia , Staphylococcus aureus Resistente à Meticilina/genética , Repetições Minissatélites , Infecções Estafilocócicas/epidemiologia , Técnicas de Tipagem Bacteriana , Infecção Hospitalar/microbiologia , Infecção Hospitalar/transmissão , Estudos Transversais , Surtos de Doenças , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Epidemiologia Molecular , Polimorfismo de Nucleotídeo Único , Infecções Estafilocócicas/microbiologia , Infecções Estafilocócicas/transmissão , Sequenciamento Completo do Genoma
10.
J Hosp Infect ; 100(2): 236-241, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29772262

RESUMO

BACKGROUND: Antimicrobial resistance has become an urgent global health priority. Basic hygiene practices and cleaning and disinfection of the hospital environment are key in preventing pathogen cross-transmission. AIM: To our knowledge no studies have assessed the worldwide differences in cleaning and disinfection practices in healthcare facilities. The electronic survey described here was developed in order to evaluate differences in healthcare facility cleaning practices around the world. METHODS: The International Society of Antimicrobial Chemotherapy (ISAC, formerly ISC), Infection Prevention and Control work group developed a survey with 30 multiple-choice questions. The questions were designed to assess the current cleaning practices in healthcare settings around the world. FINDINGS: A total of 110 healthcare professionals, representing 23 countries, participated in the online survey. In 96% of the facilities a written cleaning policy was present. Training of cleaning staff occurred in 70% of the facilities at the start of employment. Cleaning practices and monitoring of these practices varied. CONCLUSIONS: The survey enabled assessment and recognition of widely differing global practices in approaches to environmental cleaning and disinfection. Development of guideline recommendations for cleaning and disinfection could improve practices and set minimum standards worldwide.


Assuntos
Descontaminação/métodos , Transmissão de Doença Infecciosa/prevenção & controle , Desinfecção/métodos , Instalações de Saúde , Saúde Global , Política de Saúde , Humanos , Capacitação em Serviço , Política Organizacional , Inquéritos e Questionários
11.
Artigo em Inglês | MEDLINE | ID: mdl-30564309

RESUMO

Background: Endoscopy related infections represent an important threat for healthcare systems worldwide. Recent outbreaks of infections with multidrug resistant micro-organisms have highlighted the problems of contaminated endoscopes. Endoscopes at highest risk for contamination have intricate mechanisms, multiple internal channels and narrow lumens that are especially problematic to clean. In light of raised awareness about the necessity for meticulous reprocessing of all types of endoscopes, a call for international collaboration is needed. An overview is presented on current practices for endoscope reprocessing in facilities worldwide. Method: An electronic survey was developed and disseminated by the International Society for Antimicrobials and Chemotherapy. The survey consisted of 50 questions aimed at assessing the reprocessing of flexible endoscopes internationally. It covered three core elements: stakeholder involvement, assessment of perceived risks, and reprocessing process. Results: The survey received a total of 165 completed responses from 39 countries. It is evident that most facilities, 82% (n = 136), have a standard operating procedure. There is, however a lot of variation within the flexible endoscope reprocessing practices observed. The need for regular training and education of reprocessing practitioners were identified by 50% (n = 83) of the respondents as main concerns that need to be addressed in order to increase patient safety in endoscope reprocessing procedures. Conclusion: This international survey on current flexible endoscope reprocessing identified a large variation for reprocessing practices among different health care facilities/countries. A standardised education and training programme with a competency assessment is essential to prevent reprocessing lapses and improve patient safety.


Assuntos
Endoscópios/microbiologia , Endoscopia/educação , Endoscopia/normas , Contaminação de Equipamentos , Infecção Hospitalar/prevenção & controle , Desinfecção/normas , Endoscopia/efeitos adversos , Endoscopia/economia , Humanos , Controle de Infecções/métodos , Garantia da Qualidade dos Cuidados de Saúde , Fatores de Risco
12.
J Hosp Infect ; 92(1): 14-8, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26607236

RESUMO

BACKGROUND: Hospital-associated infections (HAIs) are more frequently encountered in low- than in high-resource settings. There is a need to identify and implement feasible and sustainable approaches to strengthen HAI prevention in low-resource settings. AIM: To evaluate the biological contamination of routinely cleaned mattresses in both high- and low-resource settings. METHODS: In this two-stage observational study, routine manual bed cleaning was evaluated at two university hospitals using adenosine triphosphate (ATP). Standardized training of cleaning personnel was achieved in both high- and low-resource settings. Qualitative analysis of the cleaning process was performed to identify predictors of cleaning outcome in low-resource settings. FINDINGS: Mattresses in low-resource settings were highly contaminated prior to cleaning. Cleaning significantly reduced biological contamination of mattresses in low-resource settings (P < 0.0001). After training, the contamination observed after cleaning in both the high- and low-resource settings seemed comparable. Cleaning with appropriate type of cleaning materials reduced the contamination of mattresses adequately. Predictors for mattresses that remained contaminated in a low-resource setting included: type of product used, type of ward, training, and the level of contamination prior to cleaning. CONCLUSION: In low-resource settings mattresses were highly contaminated as noted by ATP levels. Routine manual cleaning by trained staff can be as effective in a low-resource setting as in a high-resource setting. We recommend a multi-modal cleaning strategy that consists of training of domestic services staff, availability of adequate time to clean beds between patients, and application of the correct type of cleaning products.


Assuntos
Trifosfato de Adenosina/análise , Leitos/microbiologia , Pesquisa sobre Serviços de Saúde , Zeladoria Hospitalar/métodos , Infecção Hospitalar/prevenção & controle , Hospitais Universitários , Humanos , Controle de Infecções/métodos
13.
Am J Infect Control ; 44(11): 1203-1207, 2016 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-27160981

RESUMO

BACKGROUND: Hand hygiene (HH) is essential in preventing nosocomial infection. The emergency department (ED) is an open portal of entry for pathogens into the hospital system, hence the important sentinel function of the ED personnel. The main objective of this study was to assess the effect of a multimodal improvement strategy on hand hygiene compliance in the ED. METHODS: Our study was a prospective before-and-after study to determine the effect of a multimodal improvement strategy on the compliance of HH in the ED according to the My 5 Moments of Hand Hygiene defined by the World Health Organization. Interventions such as education, reminders, and regular feedback on HH performance and role models were planned during the 3 intervention weeks. RESULTS: In total, 57 ED nurses and ED physicians were observed in this study, and approximately 1,000 opportunities for handrubs were evaluated during the 3 intervention periods. HH compliance increased significantly from baseline from 18% (74/407) to 41% (77/190) after the first intervention and stabilized to 50% (99/200) and 46% (96/210) after the second and third interventions, respectively. CONCLUSIONS: Implementing a multimodal HH improvement program significantly improved the HH compliance of ED personnel.


Assuntos
Infecção Hospitalar/prevenção & controle , Serviço Hospitalar de Emergência , Fidelidade a Diretrizes/estatística & dados numéricos , Higiene das Mãos/métodos , Estudos Controlados Antes e Depois , Humanos , Estudos Prospectivos
14.
J Hosp Infect ; 90(2): 142-6, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25804978

RESUMO

BACKGROUND: Cleaning regimens for hospital beds were evaluated in the context of a rising prevalence of highly resistant micro-organisms and increasing financial pressure on healthcare systems. Dutch hospitals have to choose between standardized, mechanical bed-washers advised in national guidance and manual cleaning. AIM: To evaluate the quality of mechanical and manual bed-cleaning regimens. METHODS: The multi-faceted analysis of bed-cleaning regimens consisted of three steps. In Step 1, the training of the domestic service team was evaluated. In Step 2, the cleaning quality of manual and mechanical regimens was assessed. Soiled beds, obtained at random, from different departments were evaluated using microbiological analysis (N = 40) and ATP (N = 20). ATP and microbiological contamination were measured in five predetermined locations on all beds. In Step 3, manual cleaning was introduced over a two-month pilot study at the surgical short-stay unit, and beds from other departments were processed according to the 'gold standard' mechanical cleaning. ATP levels were evaluated in three locations on 300 beds after cleaning. FINDINGS: Training was found to improve the quality of cleaning significantly. Mechanical cleaning resulted in significantly lower ATP levels than manual cleaning. CONCLUSIONS: Mechanical cleaning shows less variation and results in consistently lower ATP levels than manual cleaning.


Assuntos
Leitos/microbiologia , Infecção Hospitalar/prevenção & controle , Desinfecção/métodos , Zeladoria Hospitalar/métodos , Controle de Infecções/métodos , Humanos , Países Baixos , Projetos Piloto , Estudos Prospectivos
15.
J Sch Psychol ; 53(1): 87-103, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25636262

RESUMO

The goal of this study was to explore relations between teacher characteristics (i.e., competence and wellbeing); social classroom relationships (i.e., teacher-child and peer interactions); and children's social, emotional, and behavioral classroom adjustment. These relations were explored at both the individual and classroom levels among 414 children with emotional and behavioral disorders placed in special education. Two models were specified. In the first model, children's classroom adjustment was regressed on social relationships and teacher characteristics. In the second model, reversed links were examined by regressing teacher characteristics on social relationships and children's adjustment. Results of model 1 showed that, at the individual level, better social and emotional adjustment of children was predicted by higher levels of teacher-child closeness and better behavioral adjustment was predicted by both positive teacher-child and peer interactions. At the classroom level, positive social relationships were predicted by higher levels of teacher competence, which in turn were associated with lower classroom levels of social problems. Higher levels of teacher wellbeing were directly associated with classroom adaptive and maladaptive child outcomes. Results of model 2 showed that, at the individual and classroom levels, only the emotional and behavioral problems of children predicted social classroom relationships. At the classroom level, teacher competence was best predicted by positive teacher-child relationships and teacher wellbeing was best predicted by classroom levels of prosocial behavior. We discuss the importance of positive teacher-child and peer interactions for children placed in special education and suggest ways of improving classroom processes by targeting teacher competence.


Assuntos
Comportamento Infantil/psicologia , Ajustamento Emocional , Docentes , Relações Interpessoais , Ajustamento Social , Comportamento Social , Adolescente , Criança , Pré-Escolar , Educação Inclusiva , Emoções , Feminino , Humanos , Masculino , Instituições Acadêmicas , Meio Social
16.
Artigo em Inglês | MEDLINE | ID: mdl-26613018

RESUMO

BACKGROUND: Attempts to increase compliance with infection control practices are complex and are - in part - based on attempts to change behaviour. In particular, the behaviour of significant peers (role models) has been shown to be a strong motivator. While role models within the working environment are obviously the most important, some experts suggest that media and public display cannot be ignored. The aim of this present study was to examine the display of technique recommended by current infection control guidelines including the "bare below the elbow" principle, which is considered a basic requirement for good infection control in many countries, in sets of professional stock photos. FINDINGS: From 20 random photo-stock websites we selected pictures with search terms "doctor and patient" and "nurse and patient". In all selected photos a doctor or nurse and a patient were presented, healthcare workers (HCWs) were wearing white coats or uniforms, and their arms were visible. Each photo was evaluated with regard to: closure of white coat, sleeve length, personal clothing covered, hairstyle and presence of a wristwatch, bracelet and/or ring. Overall, 1600 photos were evaluated. The most common mistakes were with regard to HCWs' white coats/uniforms. Eighty-nine percent of the photos containing doctor's images were considered incorrect while 28 % of nurse-containing photos were incorrect. CONCLUSIONS: The results seem to reflect the real world with only 40 % displaying correct behaviour with doctors being worse than nurses. It seems that the stereotypical image of a doctor does not agree with the current infection control guidelines. If we aim for higher compliance rates of HCWs, we need to change the social image of doctors and improve production, selection and display of stock photo images.

17.
J Abnorm Child Psychol ; 43(4): 787-99, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25212230

RESUMO

In mainstream education, positive relationships with teachers and peers have been found to positively influence children's behavioral development. However, high levels of classroom behavior problems may hinder the formation of such positive relationships. Therefore, findings from mainstream education cannot be generalized to special education. The present study investigated the developmental links between disobedience and positive as well as negative relationships with teachers and peers among boys in restrictive special educational settings. At three assessment waves across one school year, teacher-reports of teacher-child closeness and conflict, and peer-reports of peer acceptance, rejection and disobedience were collected among 340 boys (mean age = 10.1 years, SD = 1.58, range = 5-13) with psychiatric disorders receiving special education. Autoregressive cross-lagged models were fitted to explore the nature of these developmental links. The impact of boys' age was examined using multiple group analyses. Findings supported the importance of teacher-child conflict, but not closeness, and positive and negative peer relationships for the development of boys' disobedience, with a stronger effect of negative than positive relationships. However, teacher-child and peer relationships were not longitudinally related and the effect of boys' age was minimal. This study extends prior research by suggesting that, despite differences in educational setting and severity of behavior problems between children in mainstream and special education, reducing negative classroom interactional patterns is most important in preventing the development of problematic classroom behavior in boys with severe social-emotional and behavioral difficulties.


Assuntos
Transtornos do Comportamento Infantil/psicologia , Educação Inclusiva , Relações Interpessoais , Transtornos Mentais/psicologia , Comportamento Social , Adolescente , Criança , Pré-Escolar , Conflito Psicológico , Docentes , Humanos , Masculino , Grupo Associado
18.
Pediatrics ; 95(4): 555-61, 1995 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-7700758

RESUMO

OBJECTIVE: To investigate cerebral oxygenation and hemodynamics in relation to changes in some relevant physiologic variables during induction of extracorporeal membrane oxygenation (ECMO) in newborn infants. METHODS: Twenty-four newborn infants requiring ECMO were studied from cannulation until 60 minutes after starting ECMO. Concentration changes of oxyhemoglobin (cO2Hb), deoxyhemoglobin (cHHb), total hemoglobin (ctHb), and (oxidized-reduced) cytochrome aa3 (cCyt.aa3) in cerebral tissue were measured continuously by near infrared spectrophotometry. Heart rate (HR), transcutaneous partial pressures of oxygen and carbon dioxide (tcPO2 and tcPCO2), arterial O2 saturation (saO2), and mean arterial blood pressure (MABP) were measured simultaneously. Intravascular hemoglobin concentration (cHb) was measured before and after starting ECMO. In 18 of the 24 infants, mean blood flow velocity (MBFV) and pulsatility index (PI) in the internal carotid and middle cerebral arteries were also measured before and after starting ECMO using pulsed Doppler ultrasound. RESULTS: After carotid ligation, cO2Hb decreased whereas cHHb increased. After jugular ligation, no changes in cerebral oxygenation were found. At 60 minutes after starting ECMO, the values of cO2Hb, saO2, tcPO2, and MABP were significantly higher than the precannulation values, whereas the value of cHHb was lower. There were no changes in cCyt.aa3, tcPCO2, and HR, whereas cHb decreased. The MBFV was significantly increased in the major cerebral arteries except the right middle cerebral artery, whereas PI was decreased in all measured arteries. Cerebral blood volume, calculated from changes in ctHb and cHb, was increased in 20 of 24 infants after starting ECMO. Using multivariate regression models, a positive correlation of delta ctHb (representative of changes in cerebral blood volume) with delta MABP and a negative correlation with delta tcPO2 were found. CONCLUSIONS: The alterations in cerebral oxygenation after carotid artery ligation might reflect increased O2 extraction. Despite increase of the cerebral O2 supply after starting ECMO, no changes in intracellular O2 availability were found, probably because of sufficient preservation of intracellular cerebral oxygenation in the pre-ECMO period despite prolonged hypoxemia. The increase in cerebral blood volume and cerebral MBFV may result from the following: (1) reactive hyperperfusion, (2) loss of autoregulation because of prolonged hypoxemia before ECMO and/or decreased arterial pulsatility, or (3) compensation for hemodilution related to the ECMO procedure.


Assuntos
Encéfalo/irrigação sanguínea , Oxigenação por Membrana Extracorpórea , Oxigênio/sangue , Circulação Cerebrovascular/fisiologia , Ecoencefalografia , Feminino , Hemodinâmica , Humanos , Recém-Nascido , Masculino , Análise de Regressão , Insuficiência Respiratória/terapia , Espectrofotometria , Ultrassonografia Doppler
19.
Am J Cardiol ; 78(12): 1394-9, 1996 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-8970413

RESUMO

Noninvasive determination of pulmonary hemodynamics is important for the management of congenital heart disease complicated by pulmonary hypertension. Flow deceleration is less influenced by right ventricular function and would allow more accurate estimation of pulmonary hemodynamics than acceleration. Respiratory influences on pulmonary blood flow are exaggerated by mechanical ventilation. Doppler-derived pulmonary artery (PA) blood flow velocity characteristics were therefore compared with pulmonary hemodynamic parameters in 42 mechanically ventilated children, aged 0.2 to 14.8 years (mean +/- SD 6.7 +/- 4.9). Mean PA pressure ranged from 11 to 47 mm Hg (21 +/- 9 mm Hg). Pulmonary hypertension was present in 14 patients. Significant differences were found between patients with and without pulmonary hypertension in maximal velocity (1.03 +/- 0.22 vs 0.88 +/- 0.18 m/s), acceleration time (119 +/- 39 vs 136 +/- 29 ms), maximal acceleration (17.6 +/- 6.4 vs 13.1 +/- 4.0 m/s2), mean acceleration (9.3 +/- 2.6 vs 6.7 +/- 2.0 m/s2), and mean deceleration (4.5 +/- 1.0 vs 3.8 +/- 0.8 m/s2). In contrast to our hypothesis of the deceleration phase-derived parameters, only maximal deceleration correlated with PA pressure. Acceleration parameters showed closer relations with PA pressures, but correlations were generally low and did not permit accurate prediction of PA pressure (SEE 5 to 11 mm Hg), PA resistance (SEE 1.14 U. m2) or PA driving force (SEE 7 mm Hg). An analysis that took respiratory phase into account did not improve correlations. Measurement of mean acceleration, maximal deceleration, and rate-corrected preejection period permitted for accurate discrimination between the presence or absence of pulmonary hypertension, with positive and negative predictive values being 92% and 90%. In mechanically ventilated children with congenital heart disease, accurate noninvasive PA pressure assessment is not possible. Accurate predictions for the presence of pulmonary hypertension can be made by measurement of both acceleration and deceleration parameters.


Assuntos
Ecocardiografia Doppler , Cardiopatias Congênitas/fisiopatologia , Hipertensão Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Respiração Artificial , Resistência Vascular , Adolescente , Velocidade do Fluxo Sanguíneo , Criança , Pré-Escolar , Estudos de Viabilidade , Humanos , Hipertensão Pulmonar/fisiopatologia , Lactente
20.
Am J Cardiol ; 61(11): 891-4, 1988 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-3281428

RESUMO

The total intrinsic variability of pulsed Doppler spectra of mitral blood flow was evaluated in this study. Doppler examinations were performed in 10 normal volunteers (7 men, 3 women), ages 29 to 57 years (mean 41) with an interval period of 3 months. The recordings were made in the apical 4-chamber view, using a 2.25-MHz transducer. The sample was placed approximately 1 cm proximal (left atrium) and 1 cm distal (left ventricle) from the middle of the anulus of the mitral valve at the onset of diastole. Processing of the raw Doppler spectra was done in a way that avoided subjective manipulation by the investigators. Mitral peak velocities, accelerations and spectral widths were measured in early diastole and late diastole. From the parameters under investigation, maximal velocities showed the best reproducibility with a range of coefficients of variation of 9 to 13%. Peak acceleration in early diastole and spectral widths showed rather large coefficients of variation, ranging from 19 to 30 and 14 to 24%, respectively. Mitral pulsed Doppler spectra in the left atrium were more reproducible than in the left ventricle.


Assuntos
Ecocardiografia , Valva Mitral/fisiologia , Adulto , Velocidade do Fluxo Sanguíneo , Diagnóstico por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade