1.
Cytometry A ; 103(10): 786-795, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37334483

RESUMO

High throughput and efficient separation/isolation of nanoparticles such as exosomes remain a challenge owing to their small size. Elasto-inertial approaches have a new potential to be leveraged because of the ability to achieve fine control over the forces that act on extremely small particles. That is, the viscoelasticity of fluid that helps carry biological particles such as extracellular vesicles (EVs) and cells through microfluidic channels can be tailored to optimize how different-sized particles move within the chip. In this contribution, we demonstrate through computational fluid dynamics (CFD) simulations the ability to separate nanoparticles with a size comparable to exosomes from larger spheres with physical properties comparable to cells and larger EVs. Our current design makes use of an efficient flow-focusing geometry at the inlet of the device in which two side channels deliver the sample, while the inner channel injects the sheath flow. Such flow configuration results in an efficient focusing of all the particles near the sidewalls of the channel at the inlet. By dissolving a minute amount of polymer in the sample and sheath fluid, the elastic lift force arises and the initially focused particle adjacent to the wall will gradually migrate toward the center of the channel. This results in larger particles experiencing larger elastic forces, thereby migrating faster toward the center of the channel. By adjusting the size and location of the outlets, nanoparticles comparable to the size of exosomes (30-100 nm) will be effectively separated from other particles. Furthermore, the influence of different parameters such as channel geometry, flow rate, and fluid rheology on the separation process is evaluated by computational analysis.

2.
Cytometry A ; 99(2): 164-169, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33508166

RESUMO

The active metabolite of tamoxifen, 4-hydroxytamoxifen, functions as an anti-estrogen in breast cancer cells and thus inhibits proliferation. While tamoxifen continues to be successfully used to treat estrogen-dependent breast cancer, most patients receiving treatment will develop chemoresistance over time. Two commonly reported biomarkers of tamoxifen resistance are decreased expression of insulin-like growth factor 1 receptor (IGF-1R) and increased expression of epidermal growth factor receptor (EGFR). In prior work we have shown that these receptors facilitate chemoresistance and have unique regulatory functions measurable in resistant cell lines compared with nonresistant. Thus, we hypothesized that these receptors and a newly identified biomarker, integrin ß1, may be used to search for the presence of resistant breast cancer cells within a population of cells that are sensitive to tamoxifen therapy. We tested this by designing a straightforward cell-labeling approach to measure differences in the receptor expression of resistant vs. sensitive cells cytometrically. Our results show that separation is possible when observing the expression of IGF-1R as well as integrin ß1. Interestingly, we found no detectable difference in EGFR expression between tamoxifen resistant and -sensitive cells when measured with cytometry despite the fact that EGFR is upregulated in resistant cells. Our long-term goal is to utilize sorting to isolate tamoxifen resistant subpopulations of cells by receptor expression level. Isolating rare resistant cells that reside within a population of drug-sensitive cells will offer new insights into why chemoresistance occurs.


Assuntos
Neoplasias da Mama , Antineoplásicos Hormonais/farmacologia , Antineoplásicos Hormonais/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Linhagem Celular Tumoral , Resistencia a Medicamentos Antineoplásicos , Feminino , Citometria de Fluxo , Humanos , Tamoxifeno/farmacologia , Tamoxifeno/uso terapêutico
3.
Cytometry A ; 97(12): 1265-1275, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32790129

RESUMO

Caspase-3 is a well-described protease with many roles that impact the fate of a cell. During apoptosis, caspase-3 acts as an executioner caspase with important proteolytic functions that lead to the final stages of programmed cell death. Owing to this key role, caspase-3 is exploited intracellularly as a target of control of apoptosis for therapeutic outcomes. Yet the activation of caspase-3 during apoptosis is challenged by other roles and functions (e.g., paracrine signaling). This brief report presents a way to track caspase-3 levels using a flow cytometer that measures excited state fluorescence lifetimes and a signal processing approach that leads to a graphical phasor-based interpretation. An established Förster resonance energy transfer (FRET) bioprobe was used for this test; the connected donor and acceptor fluorophore is cleavable by caspase-3 during apoptosis induction. With the cell-by-cell decay kinetic data and phasor analyses we generate a caspase activation trajectory, which is used to interpret activation throughout apoptosis. When lifetime-based cytometry is combined with a FRET bioprobe and phasor analyses, enzyme activation can be simplified and quantified with phase and modulation data. We envision extrapolating this approach to high content screening, and reinforce the power of phasor approaches with cytometric data. Analyses such as these can be used to cluster cells by their phase and modulation "lifetime fingerprint" when the intracellular fluorescent probe is utilized as a sensor of enzyme activity. © 2020 The Authors. Cytometry Part A published by Wiley Periodicals LLC on behalf of International Society for Advancement of Cytometry.


Assuntos
Transferência Ressonante de Energia de Fluorescência , Corantes Fluorescentes , Apoptose , Caspase 3 , Humanos , Microscopia de Fluorescência
4.
Cytometry A ; 95(1): 70-79, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30369063

RESUMO

Autofluorescence from the intracellular metabolite, NAD(P)H, is a biomarker that is widely used and known to reliably screen and report metabolic activity as well as metabolic fluctuations within cells. As a ubiquitous endogenous fluorophore, NAD(P)H has a unique rate of fluorescence decay that is altered when bound to coenzymes. In this work we measure the shift in the fluorescence decay, or average fluorescence lifetime (1-3 ns), of NAD(P)H and correlate this shift to changes in metabolism that cells undergo during apoptosis. Our measurements are made with a flow cytometer designed specifically for fluorescence lifetime acquisition within the ultraviolet to violet spectrum. Our methods involved culture, treatment, and preparation of cells for cytometry and microscopy measurements. The evaluation we performed included observations and quantification of the changes in endogenous emission owing to the induction of apoptosis as well as changes in the decay kinetics of the emission measured by flow cytometry. Shifts in NAD(P)H fluorescence lifetime were observed as early as 15 min post-treatment with an apoptosis inducing agent. Results also include a phasor analysis to evaluate free to bound ratios of NAD(P)H at different time points. We defined the free to bound ratios as the ratio of 'short-to-long' (S/L) fluorescence lifetime, where S/L was found to consistently decrease with an increase in apoptosis. With a quantitative framework such as phasor analysis, the short and long lifetime components of NAD(P)H can be used to map the cycling of free and bound NAD(P)H during the early-to-late stages of apoptosis. The combination of lifetime screening and phasor analyses provides the first step in high throughput metabolic profiling of single cells and can be leveraged for screening and sorting for a range of applications in biomedicine. © 2018 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of International Society for Advancement of Cytometry.


Assuntos
Apoptose , Citometria de Fluxo/métodos , NADP/metabolismo , Fluorescência , Células HeLa , Humanos , Cinética , Microscopia de Fluorescência
5.
Cytometry A ; 99(2): 127-128, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33522092
6.
Opt Express ; 24(13): 14596-607, 2016 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-27410612

RESUMO

Interest in time resolved flow cytometry is growing. In this paper, we collect time-resolved flow cytometry data and use it to create polar plots showing distributions that are a function of measured fluorescence decay rates from individual fluorescently-labeled cells and fluorescent microspheres. Phasor, or polar, graphics are commonly used in fluorescence lifetime imaging microscopy (FLIM). In FLIM measurements, the plotted points on a phasor graph represent the phase-shift and demodulation of the frequency-domain fluorescence signal collected by the imaging system for each image pixel. Here, we take a flow cytometry cell counting system, introduce into it frequency-domain optoelectronics, and process the data so that each point on a phasor plot represents the phase shift and demodulation of an individual cell or particle. In order to demonstrate the value of this technique, we show that phasor graphs can be used to discriminate among populations of (i) fluorescent microspheres, which are labeled with one fluorophore type; (ii) Chinese hamster ovary (CHO) cells labeled with one and two different fluorophore types; and (iii) Saccharomyces cerevisiae cells that express combinations of fluorescent proteins with different fluorescence lifetimes. The resulting phasor plots reveal differences in the fluorescence lifetimes within each sample and provide a distribution from which we can infer the number of cells expressing unique single or dual fluorescence lifetimes. These methods should facilitate analysis time resolved flow cytometry data to reveal complex fluorescence decay kinetics.


Assuntos
Microscopia de Fluorescência/métodos , Microesferas , Animais , Células CHO , Cricetulus , Corantes Fluorescentes , Cinética , Imagem Óptica
7.
Cytometry A ; 95(6): 655-656, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31207048
8.
Cytometry A ; 85(12): 999-1010, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25274073

RESUMO

Fluorescence lifetime measurements provide information about the fluorescence relaxation, or intensity decay, of organic fluorophores, fluorescent proteins, and other inorganic molecules that fluoresce. The fluorescence lifetime is emerging in flow cytometry and is helpful in a variety of multiparametric, single cell measurements because it is not impacted by nonlinearity that can occur with fluorescence intensity measurements. Yet time-resolved cytometry systems rely on major hardware modifications making the methodology difficult to reproduce. The motivation of this work is, by taking advantage of the dynamic nature of flow cytometry sample detection and applying digital signal processing methods, to measure fluorescence lifetimes using an unmodified flow cytometer. We collect a new lifetime-dependent parameter, referred to herein as the fluorescence-pulse-delay (FPD), and prove it is a valid representation of the average fluorescence lifetime. To verify we generated cytometric pulses in simulation, with light emitting diode (LED) pulsation, and with true fluorescence measurements of cells and microspheres. Each pulse is digitized and used in algorithms to extract an average fluorescence lifetime inherent in the signal. A range of fluorescence lifetimes is measurable with this approach including standard organic fluorophore lifetimes (∼1 to 22 ns) as well as small, simulated shifts (0.1 ns) under standard conditions (reported herein). This contribution demonstrates how digital data acquisition and signal processing can reveal time-dependent information foreshadowing the exploitation of full waveform analysis for quantification of similar photo-physical events within single cells.


Assuntos
Citometria de Fluxo/métodos , Microscopia de Fluorescência/métodos , Modelos Teóricos , Processamento de Sinais Assistido por Computador , Animais , Células CHO , Cricetulus , Citometria de Fluxo/instrumentação
10.
Electrophoresis ; 35(12-13): 1846-54, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24668857

RESUMO

Flow cytometers are powerful high-throughput devices that capture spectroscopic information from individual particles or cells. These instruments provide a means of multi-parametric analyses for various cellular biomarkers or labeled organelles and cellular proteins. However, the spectral overlap of fluorophores limits the number of fluorophores that can be used simultaneously during experimentation. Time-resolved parameters enable the quantification of fluorescence decay kinetics, thus circumventing common issues associated with intensity-based measurements. This contribution introduces fluorescence lifetime excitation cytometry by kinetic dithering (FLECKD) as a method to capture multiple fluorescence lifetimes using a hybrid time-domain approach. The FLECKD approach excites fluorophores by delivering short pulses of light to cells or particles by rapid dithering and facilitates measurement of complex fluorescence decay kinetics by flow cytometry. Our simulations demonstrated a resolvable fluorescence lifetime value as low as 1.8 ns (±0.3 ns) with less than 20% absolute error. Using the FLECKD instrument, we measured the shortest average fluorescence lifetime value of 2.4 ns and found the system measurement error to be ±0.3 ns (SEM), from hundreds of monodisperse and chemically stable fluorescent microspheres. Additionally, we demonstrate the ability to detect two distinct excited state lifetimes from fluorophores in single cells using FLECKD. This approach presents a new ability to resolve multiple fluorescence lifetimes while retaining the fluidic throughput of a cytometry system. The ability to discriminate more than one average fluorescence lifetime expands the current capabilities of high-throughput and intensity-based cytometry assays as the need to tag one single cell with multiple fluorophores is now widespread.


Assuntos
Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Processamento de Sinais Assistido por Computador , Animais , Células CHO , Simulação por Computador , Cricetinae , Cricetulus , Corantes Fluorescentes/química , Cinética , Microesferas
11.
Micromachines (Basel) ; 15(7)2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-39064333

RESUMO

Recently, microfluidics deformability cytometry has emerged as a powerful tool for high-throughput mechanical phenotyping of large populations of cells. These methods characterize cells by their mechanical fingerprints by exerting hydrodynamic forces and monitoring the resulting deformation. These devices have shown great promise for label-free cytometry, yet there is a critical need to improve their accuracy and reconcile any discrepancies with other methods, such as atomic force microscopy. In this study, we employ computational fluid dynamics simulations and uncover how the elasticity of frequently used carrier fluids, such as methylcellulose dissolved in phosphate-buffered saline, is significantly influential to the resulting cellular deformation. We conducted CFD simulations conventionally used within the deformability cytometry field, which neglect fluid elasticity. Subsequently, we incorporated a more comprehensive model that simulates the viscoelastic nature of the carrier fluid. A comparison of the predicted stresses between these two approaches underscores the significance of the emerging elastic stresses in addition to the well-recognized viscous stresses along the channel. Furthermore, we utilize a two-phase flow model to predict the deformation of a promyelocyte (i.e., HL-60 cell type) within a hydrodynamic constriction channel. The obtained results highlight a substantial impact of the elasticity of carrier fluid on cellular deformation and raise questions about the accuracy of mechanical property estimates derived by neglecting elastic stresses.

12.
Methods Mol Biol ; 2779: 323-351, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38526793

RESUMO

This chapter focuses on applications and protocols that involve the measurement of the fluorescence lifetime as an informative cytometric parameter. The timing of fluorescence decay has been well-studied for cell counting, sorting, and imaging. Therefore, provided herein is an overview of the techniques used, how they enhance cytometry protocols, and the modern techniques used for lifetime analysis. The background and theory behind fluorescence decay kinetic measurements in cells is first discussed followed by the history of the development of time-resolved flow cytometry. These sections are followed by a review of applications that benefit from the quantitative nature of fluorescence lifetimes as a photophysical trait. Lastly, perspectives on the modern ways in which the fluorescence lifetime is scanned at high throughputs which include high-speed microscopy and machine learning are provided.


Assuntos
Corantes Fluorescentes , Literatura de Revisão como Assunto , Fluorescência , Citometria de Fluxo/métodos , Microscopia de Fluorescência/métodos , Cinética
13.
Nat Commun ; 15(1): 7376, 2024 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-39231964

RESUMO

Flow cytometry is a vital tool in biomedical research and laboratory medicine. However, its accuracy is often compromised by undesired fluctuations in fluorescence intensity. While fluorescence lifetime imaging microscopy (FLIM) bypasses this challenge as fluorescence lifetime remains unaffected by such fluctuations, the full integration of FLIM into flow cytometry has yet to be demonstrated due to speed limitations. Here we overcome the speed limitations in FLIM, thereby enabling high-throughput FLIM flow cytometry at a high rate of over 10,000 cells per second. This is made possible by using dual intensity-modulated continuous-wave beam arrays with complementary modulation frequency pairs for fluorophore excitation and acquiring fluorescence lifetime images of rapidly flowing cells. Moreover, our FLIM system distinguishes subpopulations in male rat glioma and captures dynamic changes in the cell nucleus induced by an anti-cancer drug. FLIM flow cytometry significantly enhances cellular analysis capabilities, providing detailed insights into cellular functions, interactions, and environments.


Assuntos
Citometria de Fluxo , Glioma , Citometria de Fluxo/métodos , Animais , Ratos , Glioma/diagnóstico por imagem , Glioma/patologia , Glioma/metabolismo , Masculino , Microscopia de Fluorescência/métodos , Linhagem Celular Tumoral , Imagem Óptica/métodos , Humanos , Núcleo Celular/metabolismo , Ensaios de Triagem em Larga Escala/métodos , Corantes Fluorescentes/química
14.
Opt Express ; 21(12): 14816-31, 2013 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-23787669

RESUMO

Flow cytometry is a well-established and powerful high- throughput fluorescence measurement tool that also allows for the sorting and enrichment of subpopulations of cells expressing unique fluorescence signatures. Owing to the reliance on intensity-only signals, flow cytometry sorters cannot easily discriminate between fluorophores that spectrally overlap. In this paper we demonstrate a new method of cell sorting using a fluorescence lifetime-dependent methodology. This approach, referred to herein as phase-filtered cell sorting (PFCS), permits sorting based on the average fluorescence lifetime of a fluorophore by separating fluorescence signals from species that emit differing average fluorescence lifetimes. Using lifetime-dependent hardware, cells and microspheres labeled with fluorophores were sorted with purities up to 90%. PFCS is a practical approach for separating populations of cells that are stained with spectrally overlapping fluorophores or that have interfering autofluorescence signals.


Assuntos
Separação Celular/instrumentação , Citometria de Fluxo/instrumentação , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Microscopia de Fluorescência por Excitação Multifotônica/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
16.
Front Phys ; 92021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34386487

RESUMO

Conventional flow cytometry is a valuable quantitative tool. Flow cytometers reveal physical and biochemical information from cells at a high throughput, which is quite valuable for many biomedical, biological, and diagnostic research fields. Flow cytometers range in complexity and typically provide multiparametric data for the user at rates of up to 50,000 cells measured per second. Cytometry systems are configured such that fluorescence or scattered light signals are collected per-cell, and the integrated optical signal at a given wavelength range indicates a particular cellular feature such as phenotype or morphology. When the timing of the optical signal is measured, the cytometry system becomes "time-resolved." Time-resolved flow cytometry (TRFC) instruments can detect fluorescence decay kinetics, and such measurements are consequential for Förster Resonance Energy Transfer (FRET) studies, multiplexing, and metabolic mapping, to name a few. TRFC systems capture fluorescence lifetimes at rates of thousands of cells per-second, however the approach is challenged at this throughput by terminal cellular velocities. High flow rates limit the total number of photons integrated per-cell, reducing the reliability of the average lifetime as a cytometric parameter. In this contribution, we examine an innovative approach to address this signal-to-noise issue. The technology merges time-resolved hardware with microfluidics and acoustics. We present an "acoustofluidic" time-resolved flow cytometer so that cellular velocities can be adjusted on the fly with a standing acoustic wave (SAW). Our work shows that acoustic control can be combined with time-resolved features to appropriately balance the throughput with the optical signals necessary for lifetime data.

17.
Front Phys ; 92021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34007839

RESUMO

Though much of the interest in fluorescence in the past has been on measuring spectral qualities such as wavelength and intensity, there are two other highly useful intrinsic properties of fluorescence: lifetime (or decay) and anisotropy (or polarization). Each has its own set of unique advantages, limitations, and challenges in detection when it comes to use in biological studies. This review will focus on the property of fluorescence lifetime, providing a brief background on instrumentation and theory, and examine the recent advancements and applications of measuring lifetime in the fields of high-throughput fluorescence lifetime imaging microscopy (HT-FLIM) and time-resolved flow cytometry (TRFC). In addition, the crossover of these two methods and their outlooks will be discussed.

18.
Cytometry A ; 77(9): 861-72, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20662090

RESUMO

Frequency-domain flow cytometry techniques are combined with modifications to the digital signal-processing capabilities of the open reconfigurable cytometric acquisition system (ORCAS) to analyze fluorescence decay lifetimes and control sorting. Real-time fluorescence lifetime analysis is accomplished by rapidly digitizing correlated, radiofrequency (RF)-modulated detector signals, implementing Fourier analysis programming with ORCAS' digital signal processor (DSP) and converting the processed data into standard cytometric list mode data. To systematically test the capabilities of the ORCAS 50 MS/sec analog-to-digital converter (ADC) and our DSP programming, an error analysis was performed using simulated light scatter and fluorescence waveforms (0.5-25 ns simulated lifetime), pulse widths ranging from 2 to 15 micros, and modulation frequencies from 2.5 to 16.667 MHz. The standard deviations of digitally acquired lifetime values ranged from 0.112 to >2 ns, corresponding to errors in actual phase shifts from 0.0142 degrees to 1.6 degrees. The lowest coefficients of variation (<1%) were found for 10-MHz modulated waveforms having pulse widths of 6 micros and simulated lifetimes of 4 ns. Direct comparison of the digital analysis system to a previous analog phase-sensitive flow cytometer demonstrated similar precision and accuracy on measurements of a range of fluorescent microspheres, unstained cells, and cells stained with three common fluorophores. Sorting based on fluorescence lifetime was accomplished by adding analog outputs to ORCAS and interfacing with a commercial cell sorter with a RF-modulated solid-state laser. Two populations of fluorescent microspheres with overlapping fluorescence intensities but different lifetimes (2 and 7 ns) were separated to approximately 98% purity. Overall, the digital signal acquisition and processing methods we introduce present a simple yet robust approach to phase-sensitive measurements in flow cytometry. The ability to simply and inexpensively implement this system on a commercial flow sorter will allow both better dissemination of this technology and better exploitation of the traditionally underutilized parameter of fluorescence lifetime.


Assuntos
Citometria de Fluxo/métodos , Processamento de Sinais Assistido por Computador , Animais , Células CHO , Simulação por Computador , Cricetinae , Cricetulus , Fluorescência , Corantes Fluorescentes/química , Microesferas , Coloração e Rotulagem/métodos
19.
Radiology ; 246(3): 734-41, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18223125

RESUMO

PURPOSE: To prospectively demonstrate the feasibility of using indocyanine green, a near-infrared (NIR) fluorophore at the minimum dose needed for noninvasive optical imaging of lymph nodes (LNs) in breast cancer patients undergoing sentinel lymph node mapping (SLNM). MATERIALS AND METHODS: Informed consent was obtained from 24 women (age range, 30-85 years) who received intradermal subcutaneous injections of 0.31-100 microg indocyanine green in the breast in this IRB-approved, HIPAA-compliant, dose escalation study to find the minimum microdose for imaging. The breast, axilla, and sternum were illuminated with NIR light and the fluorescence generated in the tissue was collected with an NIR-sensitive intensified charged-coupled device. Lymphoscintigraphy was also performed. Resected LNs were evaluated for the presence of radioactivity, blue dye accumulation, and fluorescence. The associations between the resected LNs that were fluorescent and (a) the time elapsed between NIR fluorophore administration and resection and (b) the dosage of NIR fluorophores were tested with the Spearman rank and Pearson product moment correlation tests, respectively. RESULTS: Lymph imaging consistently failed with indocyanine green microdosages between 0.31 and 0.77 microg. When indocyanine green dosages were 10 microg or higher, lymph drainage pathways from the injection site to LNs were imaged in eight of nine women; lymph propulsion was observed in seven of those eight. When propulsion in the breast and axilla regions was present, the mean apparent velocities ranged from 0.08 to 0.32 cm/sec, the time elapsed between "packets" of propelled fluid varied from 14 to 92 seconds. In patients who received 10 microg of indocyanine green or more, a weak negative correlation between the fluorescence status of resected LNs and the time between NIR fluorophore administration and LN resection was found. No statistical association was found between the fluorescence status of resected LNs and the dose of NIR fluorophore. CONCLUSION: NIR fluorescence imaging of lymph function and LNs is feasible in humans at microdoses that would be needed for future molecular imaging of cancer-positive LNs.


Assuntos
Neoplasias da Mama/patologia , Corantes Fluorescentes , Verde de Indocianina , Linfonodos/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Axila , Neoplasias da Mama/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Câmaras gama , Humanos , Linfonodos/diagnóstico por imagem , Metástase Linfática , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Cintilografia , Biópsia de Linfonodo Sentinela , Esterno
20.
Methods Mol Biol ; 1678: 421-446, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29071689

RESUMO

The focus of this chapter is time-resolved flow cytometry, which is broadly defined as the ability to measure the timing of fluorescence decay from excited fluorophores that pass through cytometers or high-throughput cell counting and cell sorting instruments. We focus on this subject for two main reasons: first, to discuss the nuances of hardware and software modifications needed for these measurements because currently, there are no widespread time-resolved cytometers nor a one-size-fits-all approach; and second, to summarize the application space for fluorescence lifetime-based cell counting/sorting owing to the recent increase in the number of investigators interested in this approach. Overall, this chapter is structured into three sections: (1) theory of fluorescence decay kinetics, (2) modern time-resolved flow cytometry systems, and (3) cell counting and sorting applications. These commentaries are followed by conclusions and discussion about new directions and opportunities for fluorescence lifetime measurements in flow cytometry.


Assuntos
Citometria de Fluxo , Corantes Fluorescentes , Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Fluorescência , Transferência Ressonante de Energia de Fluorescência , Cinética , Proteínas Luminescentes , Fatores de Tempo , Fluxo de Trabalho