1.
Magn Reson Med ; 91(5): 1936-1950, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38174593

RESUMO

PURPOSE: Widely used conventional 2D T2 * approaches that are based on breath-held, electrocardiogram (ECG)-gated, multi-gradient-echo sequences are prone to motion artifacts in the presence of incomplete breath holding or arrhythmias, which is common in cardiac patients. To address these limitations, a 3D, non-ECG-gated, free-breathing T2 * technique that enables rapid whole-heart coverage was developed and validated. METHODS: A continuous random Gaussian 3D k-space sampling was implemented using a low-rank tensor framework for motion-resolved 3D T2 * imaging. This approach was tested in healthy human volunteers and in swine before and after intravenous administration of ferumoxytol. RESULTS: Spatial-resolution matched T2 * images were acquired with 2-3-fold reduction in scan time using the proposed T2 * mapping approach relative to conventional T2 * mapping. Compared with the conventional approach, T2 * images acquired with the proposed method demonstrated reduced off-resonance and flow artifacts, leading to higher image quality and lower coefficient of variation in T2 *-weighted images of the myocardium of swine and humans. Mean myocardial T2 * values determined using the proposed and conventional approaches were highly correlated and showed minimal bias. CONCLUSION: The proposed non-ECG-gated, free-breathing, 3D T2 * imaging approach can be performed within 5 min or less. It can overcome critical image artifacts from undesirable cardiac and respiratory motion and bulk off-resonance shifts at the heart-lung interface. The proposed approach is expected to facilitate faster and improved cardiac T2 * mapping in those with limited breath-holding capacity or arrhythmias.


Assuntos
Coração , Miocárdio , Humanos , Animais , Suínos , Coração/diagnóstico por imagem , Respiração , Suspensão da Respiração , Imagem Cinética por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Imageamento Tridimensional/métodos
2.
Magn Reson Med ; 89(4): 1496-1505, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36336794

RESUMO

PURPOSE: To extend the MR MultiTasking-based Multidimensional Assessment of Cardiovascular System (MT-MACS) technique with larger spatial coverage and water-fat separation for comprehensive aortocardiac assessment. METHODS: MT-MACS adopts a low-rank tensor image model for 7D imaging, with three spatial dimensions for volumetric imaging, one cardiac motion dimension for cine imaging, one respiratory motion dimension for free-breathing imaging, one T2-prepared inversion recovery time dimension for multi-contrast assessment, and one T2*-decay time dimension for water-fat separation. Nine healthy subjects were recruited for the 3T study. Overall image quality was scored on bright-blood (BB), dark-blood (DB), and gray-blood (GB) contrasts using a 4-point scale (0-poor to 3-excellent) by two independent readers, and their interreader agreement was evaluated. Myocardial wall thickness and left ventricular ejection fraction (LVEF) were quantified on DB and BB contrasts, respectively. The agreement in these metrics between MT-MACS and conventional breath-held, electrocardiography-triggered 2D sequences were evaluated. RESULTS: MT-MACS provides both water-only and fat-only images with excellent image quality (average score = 3.725/3.780/3.835/3.890 for BB/DB/GB/fat-only images) and moderate to high interreader agreement (weighted Cohen's kappa value = 0.727/0.668/1.000/1.000 for BB/DB/GB/fat-only images). There were good to excellent agreements in myocardial wall thickness measurements (intraclass correlation coefficients [ICC] = 0.781/0.929/0.680/0.878 for left atria/left ventricle/right atria/right ventricle) and LVEF quantification (ICC = 0.716) between MT-MACS and 2D references. All measurements were within the literature range of healthy subjects. CONCLUSION: The refined MT-MACS technique provides multi-contrast, phase-resolved, and water-fat imaging of the aortocardiac systems and allows evaluation of anatomy and function. Clinical validation is warranted.


Assuntos
Imageamento Tridimensional , Água , Humanos , Volume Sistólico , Imageamento Tridimensional/métodos , Função Ventricular Esquerda , Ventrículos do Coração , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética
3.
Magn Reson Med ; 89(1): 161-176, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36128892

RESUMO

PURPOSE: To develop an MR multitasking-based dynamic imaging for cerebrovascular evaluation (MT-DICE) technique for simultaneous quantification of permeability and leakage-insensitive perfusion with a single-dose contrast injection. METHODS: MT-DICE builds on a saturation-recovery prepared multi-echo fast low-angle shot sequence. The k-space is randomly sampled for 7.6 min, with single-dose contrast agent injected 1.5 min into the scan. MR multitasking is used to model the data into six dimensions, including three spatial dimensions for whole-brain coverage, a saturation-recovery time dimension, and a TE dimension for dynamic T 1 $$ {\mathrm{T}}_1 $$ and T 2 * $$ {\mathrm{T}}_2^{\ast } $$ quantification, respectively, and a contrast dynamics dimension for capturing contrast kinetics. The derived pixel-wise T 1 / T 2 * $$ {\mathrm{T}}_1/{\mathrm{T}}_2^{\ast } $$ time series are converted into contrast concentration-time curves for calculation of kinetic metrics. The technique was assessed for its agreement with reference methods in T 1 $$ {\mathrm{T}}_1 $$ and T 2 * $$ {\mathrm{T}}_2^{\ast } $$ measurements in eight healthy subjects and, in three of them, inter-session repeatability of permeability and leakage-insensitive perfusion parameters. Its feasibility was also demonstrated in four patients with brain tumors. RESULTS: MT-DICE T 1 / T 2 * $$ {\mathrm{T}}_1/{\mathrm{T}}_2^{\ast } $$ values of normal gray matter and white matter were in excellent agreement with reference values (intraclass correlation coefficients = 0.860/0.962 for gray matter and 0.925/0.975 for white matter ). Both permeability and perfusion parameters demonstrated good to excellent intersession agreement with the lowest intraclass correlation coefficients at 0.694. Contrast kinetic parameters in all healthy subjects and patients were within the literature range. CONCLUSION: Based on dynamic T 1 / T 2 * $$ {\mathrm{T}}_1/{\mathrm{T}}_2^{\ast } $$ mapping, MT-DICE allows for simultaneous quantification of permeability and leakage-insensitive perfusion metrics with a single-dose contrast injection.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Perfusão , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Permeabilidade
4.
Magn Reson Med ; 86(2): 637-647, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33768617

RESUMO

PURPOSE: (1) To investigate the effect of internal localized movement on 3DMR intracranial vessel wall imaging and (2) to develop a novel motion-compensation approach combining volumetric navigator (vNav) and self-gating (SG) to simultaneously compensate for bulk and localized movements. METHODS: A 3D variable-flip-angle turbo spin-echo (ie, SPACE) sequence was modified to incorporate vNav and SG modules. The SG signals from the center k-space line are acquired at the beginning of each TR to detect localized motion-affected TRs. The vNavs from low-resolution 3D EPI are acquired to identify bulk head motion. Fifteen healthy subjects and 3 stroke patients were recruited in this study. Overall image quality (0-poor to 4-excellent) and vessel wall sharpness were compared among the scenarios with and without bulk and/or localized motion and/or the proposed compensation strategies. RESULTS: Localized motion reduced wall sharpness, which was significantly mitigated by SG (ie, outer boundary of basilar artery: 0.68 ± 0.27 vs 0.86 ± 0.17; P = .037). When motion occurred, the overall image quality and vessel wall sharpness obtained with vNav-SG SPACE were significantly higher than those obtained with conventional SPACE (ie, basilarartery outer boundary sharpness: 0.73 ± 0.24 vs 0.94 ± 0.24; P = .033), yet comparable to those obtained in motion-free scans (ie, basilarartery outer boundary sharpness: 0.94 ± 0.24 vs 0.96 ± 0.31; P = .815). CONCLUSION: Localized movements can induce considerable artifacts in intracranial vessel wall imaging. The vNav-SG approach is capable of compensating for both bulk and localized motions.


Assuntos
Aumento da Imagem , Angiografia por Ressonância Magnética , Artefatos , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Movimento (Física)
5.
Magn Reson Med ; 84(5): 2376-2388, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32301164

RESUMO

PURPOSE: To develop an MR multitasking-based multidimensional assessment of cardiovascular system (MT-MACS) with electrocardiography-free and navigator-free data acquisition for a comprehensive evaluation of thoracic aortic diseases. METHODS: The MT-MACS technique adopts a low-rank tensor image model with a cardiac time dimension for phase-resolved cine imaging and a T2 -prepared inversion-recovery dimension for multicontrast assessment. Twelve healthy subjects and 2 patients with thoracic aortic diseases were recruited for the study at 3 T, and both qualitative (image quality score) and quantitative (contrast-to-noise ratio between lumen and wall, lumen and wall area, and aortic strain index) analyses were performed in all healthy subjects. The overall image quality was scored based on a 4-point scale: 3, excellent; 2, good; 1, fair; and 0, poor. Statistical analysis was used to test the measurement agreement between MT-MACS and its corresponding 2D references. RESULTS: The MT-MACS images reconstructed from acquisitions as short as 6 minutes demonstrated good or excellent image quality for bright-blood (2.58 ± 0.46), dark-blood (2.58 ± 0.50), and gray-blood (2.17 ± 0.53) contrast weightings, respectively. The contrast-to-noise ratios for the three weightings were 49.2 ± 12.8, 20.0 ± 5.8 and 2.8 ± 1.8, respectively. There were good agreements in the lumen and wall area (intraclass correlation coefficient = 0.993, P < .001 for lumen; intraclass correlation coefficient = 0.969, P < .001 for wall area) and strain (intraclass correlation coefficient = 0.947, P < .001) between MT-MACS and conventional 2D sequences. CONCLUSION: The MT-MACS technique provides high-quality, multidimensional images for a comprehensive assessment of the thoracic aorta. Technical feasibility was demonstrated in healthy subjects and patients with thoracic aortic diseases. Further clinical validation is warranted.


Assuntos
Aorta Torácica , Doenças da Aorta , Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Estudos de Viabilidade , Humanos , Espectroscopia de Ressonância Magnética , Reprodutibilidade dos Testes
6.
Ther Adv Cardiovasc Dis ; 16: 17539447221107737, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35762763

RESUMO

Intracardiac thrombus in the left atrium and atrial appendage (LA/LAA) and left ventricle (LV) increases the risk of systemic thromboembolism and causes potentially devastating diseases such as ischemic stroke and acute ischemia in abdominal organs and lower extremities. Detecting the presence and monitoring the resolution of left heart intracardiac thrombus are of vital importance for stratifying patients and guiding treatment decisions. Currently, echocardiography is the most frequently used method for the above clinical needs, followed by computed tomography. An increasing number of studies have been performed to investigate the value of cardiac magnetic resonance (CMR) as an alternative imaging modality given its several unique strengths. This article provides an overview of the clinical relevance of the LA/LAA and LV thrombus as well as the diagnostic performance of the current imaging modalities and emerging CMR techniques.


Assuntos
Apêndice Atrial , Cardiopatias , Trombose , Apêndice Atrial/patologia , Átrios do Coração , Cardiopatias/diagnóstico por imagem , Cardiopatias/terapia , Humanos , Espectroscopia de Ressonância Magnética/efeitos adversos , Trombose/diagnóstico por imagem
7.
Phys Med Biol ; 67(13)2022 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-35697010

RESUMO

Objective.To develop and test the feasibility of a novel Single ProjectIon DrivEn Real-time Multi-contrast (SPIDERM) MR imaging technique that can generate real-time 3D images on-the-fly with flexible contrast weightings and a low latency.Approach.In SPIDERM, a 'prep' scan is first performed, with sparse k-space sampling periodically interleaved with the central k-space line (navigator data), to learn a subject-specific model, incorporating a spatial subspace and a linear transformation between navigator data and subspace coordinates. A 'live' scan is then performed by repeatedly acquiring the central k-space line only to dynamically determine subspace coordinates. With the 'prep'-learned subspace and 'live' coordinates, real-time 3D images are generated on-the-fly with computationally efficient matrix multiplication. When implemented based on a multi-contrast pulse sequence, SPIDERM further allows for data-driven image contrast regeneration to convert real-time contrast-varying images into contrast-frozen images at user's discretion while maintaining motion states. Both digital phantom andin-vivoexperiments were performed to evaluate the technical feasibility of SPIDERM.Main results.The elapsed time from the input of the central k-space line to the generation of real-time contrast-frozen 3D images was approximately 45 ms, permitting a latency of 55 ms or less. Motion displacement measured from SPIDERM and reference images showed excellent correlation (R2≥0.983). Geometric variation from the ground truth in the digital phantom was acceptable as demonstrated by pancreas contour analysis (Dice ≥ 0.84, mean surface distance ≤ 0.95 mm). Quantitative image quality metrics showed good consistency between reference images and contrast-varying SPIDREM images inin-vivostudies (meanNMRSE=0.141,PSNR=30.12,SSIM=0.88).Significance.SPIDERM is capable of generating real-time multi-contrast 3D images with a low latency. An imaging framework based on SPIDERM has the potential to serve as a standalone package for MR-guided radiation therapy by offering adaptive simulation through a 'prep' scan and real-time image guidance through a 'live' scan.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Abdome , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Imagens de Fantasmas
8.
Front Cardiovasc Med ; 9: 833257, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35310971

RESUMO

The aim of this study is to simultaneously quantify T1/T2 across three slices of the left-ventricular myocardium without breath-holds or ECG monitoring, all within a 3 min scan. Radial simultaneous multi-slice (SMS) encoding, self-gating, and image reconstruction was incorporated into the cardiovascular magnetic resonance (CMR) Multitasking framework to simultaneously image three short-axis slices. A T2prep-IR FLASH sequence with two flip angles was designed and implemented to allow B1+-robust T1 and T2 mapping. The proposed Multitasking-SMS method was validated in a standardized phantom and 10 healthy volunteers, comparing T1 and T2 measurements and scan-rescan repeatability against corresponding reference methods in one layer of phantom vials and in 16 American Heart Association (AHA) myocardial segments. In phantom, Multitasking-SMS T1/T2 measurements showed substantial correlation (R 2 > 0.996) and excellent agreement [intraclass correlation coefficients (ICC) ≥ 0.999)] with reference measurements. In healthy volunteers, Multitasking-SMS T1/T2 maps reported similar myocardial T1/T2 values (1,215 ± 91.0/41.5 ± 6.3 ms) to the reference myocardial T1/T2 values (1,239 ± 67.5/42.7 ± 4.1 ms), with P = 0.347 and P = 0.296, respectively. Bland-Altman analyses also demonstrated good in vivo repeatability in both the multitasking and references, with segment-wise coefficients of variation of 4.7% (multitasking T1), 8.9% (multitasking T2), 2.4% [modified look-locker inversion recovery (MOLLI)], and 4.6% (T2-prep FLASH), respectively. In summary, multitasking-SMS is feasible for free-breathing, non-ECG, myocardial T1/T2 quantification in 16 AHA segments over 3 short-axis slices in 3 min. The method shows the great potential for reducing exam time for quantitative CMR without ECG or breath-holds.

SELEÇÃO DE REFERÊNCIAS