Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
J Natl Compr Canc Netw ; 22(3): 158-166, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38626807

RESUMO

BACKGROUND: Pancreatic adenocarcinoma (PC) is a highly lethal malignancy with a survival rate of only 12%. Surveillance is recommended for high-risk individuals (HRIs), but it is not widely adopted. To address this unmet clinical need and drive early diagnosis research, we established the Pancreatic Cancer Early Detection (PRECEDE) Consortium. METHODS: PRECEDE is a multi-institutional international collaboration that has undertaken an observational prospective cohort study. Individuals (aged 18-90 years) are enrolled into 1 of 7 cohorts based on family history and pathogenic germline variant (PGV) status. From April 1, 2020, to November 21, 2022, a total of 3,402 participants were enrolled in 1 of 7 study cohorts, with 1,759 (51.7%) meeting criteria for the highest-risk cohort (Cohort 1). Cohort 1 HRIs underwent germline testing and pancreas imaging by MRI/MR-cholangiopancreatography or endoscopic ultrasound. RESULTS: A total of 1,400 participants in Cohort 1 (79.6%) had completed baseline imaging and were subclassified into 3 groups based on familial PC (FPC; n=670), a PGV and FPC (PGV+/FPC+; n=115), and a PGV with a pedigree that does not meet FPC criteria (PGV+/FPC-; n=615). One HRI was diagnosed with stage IIB PC on study entry, and 35.1% of HRIs harbored pancreatic cysts. Increasing age (odds ratio, 1.05; P<.001) and FPC group assignment (odds ratio, 1.57; P<.001; relative to PGV+/FPC-) were independent predictors of harboring a pancreatic cyst. CONCLUSIONS: PRECEDE provides infrastructure support to increase access to clinical surveillance for HRIs worldwide, while aiming to drive early PC detection advancements through longitudinal standardized clinical data, imaging, and biospecimen captures. Increased cyst prevalence in HRIs with FPC suggests that FPC may infer distinct biological processes. To enable the development of PC surveillance approaches better tailored to risk category, we recommend adoption of subclassification of HRIs into FPC, PGV+/FPC+, and PGV+/FPC- risk groups by surveillance protocols.


Assuntos
Adenocarcinoma , Neoplasias Pancreáticas , Humanos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/epidemiologia , Detecção Precoce de Câncer/métodos , Estudos Prospectivos , Predisposição Genética para Doença , Imageamento por Ressonância Magnética
2.
AJR Am J Roentgenol ; 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38809122

RESUMO

Pancreatic ductal adenocarcinoma (PDA) is one of the most aggressive cancers. It has a poor 5-year survival rate of 12%, partly because most cases are diagnosed at advanced stages, precluding curative surgical resection. Early-stage PDA has significantly better prognoses due to increased potential for curative interventions, making early detection of PDA critically important to improved patient outcomes. We examine current and evolving early detection concepts, screening strategies, diagnostic yields among high-risk individuals, controversies, and limitations of standard-of-care imaging.

3.
AJR Am J Roentgenol ; 219(6): 903-914, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35856454

RESUMO

Pancreatic ductal adenocarcinoma (PDAC) is one of the most aggressive malignancies, with a dismal survival rate. Screening the general population for early detection of PDAC is not recommended, but because early detection improves survival, high-risk individuals, defined as those meeting criteria based on a family history of PDAC and/or the presence of known pathogenic germline variant genes with PDAC risk, are recommended to undergo screening with MRI and/or endoscopic ultrasound at regular intervals. The Pancreatic Cancer Early Detection (PRECEDE) Consortium was formed in 2018 and is composed of gastroenterologists, geneticists, pancreatic surgeons, radiologists, statisticians, and researchers from 40 sites in North America, Europe, and Asia. The overarching goal of the PRECEDE Consortium is to facilitate earlier diagnosis of PDAC for high-risk individuals to increase survival of the disease. A standardized MRI protocol and reporting template are needed to enhance the quality of screening examinations, improve consistency of clinical management, and facilitate multiinstitutional research. We present a consensus statement to standardize MRI screening and reporting for individuals with elevated risk of pancreatic cancer.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Humanos , Detecção Precoce de Câncer , Carcinoma Ductal Pancreático/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/genética , Imageamento por Ressonância Magnética , Padrões de Referência , Neoplasias Pancreáticas
4.
AJR Am J Roentgenol ; 217(2): 347-358, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32936014

RESUMO

Ileal pouch-anal anastomosis (IPAA) surgery is the reference standard surgical procedure for treatment of ulcerative colitis and most patients with familial adenomatous polyposis. This procedure allows preservation of fecal continence and gastrointestinal continuity. However, it is associated with a wide variety of complications, which often have nonspecific and overlapping clinical presentations, making imaging an important part of workup for pouch dysfunction. The purpose of this article is to propose structured reporting templates for MRI and water-soluble contrast enema (WSCE), based on our referral pouch center's experience, in patients who have undergone IPAA surgery. We review salient surgical technique, pouch anatomy, and imaging protocols, with an emphasis on a systematic search pattern for evaluation of ileal pouch complications using proposed structured reporting templates for MRI and WSCE.


Assuntos
Meios de Contraste , Enema/métodos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Proctocolectomia Restauradora , Colo/diagnóstico por imagem , Humanos , Reto/diagnóstico por imagem , Encaminhamento e Consulta
5.
Magn Reson Med ; 83(1): 94-108, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31400028

RESUMO

PURPOSE: To propose a highly accelerated, high-resolution dynamic contrast-enhanced MRI (DCE-MRI) technique called GRASP-Pro (golden-angle radial sparse parallel imaging with imProved performance) through a joint sparsity and self-calibrating subspace constraint with automated selection of contrast phases. METHODS: GRASP-Pro reconstruction enforces a combination of an explicit low-rank subspace-constraint and a temporal sparsity constraint. The temporal basis used to construct the subspace is learned from an intermediate reconstruction step using the low-resolution portion of radial k-space, which eliminates the need for generating the basis using auxiliary data or a physical signal model. A convolutional neural network was trained to generate the contrast enhancement curve in the artery, from which clinically relevant contrast phases are automatically selected for evaluation. The performance of GRASP-Pro was demonstrated for high spatiotemporal resolution DCE-MRI of the prostate and was compared against standard GRASP in terms of overall image quality, image sharpness, and residual streaks and/or noise level. RESULTS: Compared to GRASP, GRASP-Pro reconstructed dynamic images with enhanced sharpness, less residual streaks and/or noise, and finer delineation of the prostate without prolonging reconstruction time. The image quality improvement reached statistical significance (P < 0.05) in all the assessment categories. The neural network successfully generated contrast enhancement curves in the artery, and corresponding peak enhancement indexes correlated well with that from the manual selection. CONCLUSION: GRASP-Pro is a promising method for rapid and continuous DCE-MRI. It enables superior reconstruction performance over standard GRASP and allows reliable generation of artery enhancement curve to guide the selection of desired contrast phases for improving the efficiency of GRASP MRI workflow.


Assuntos
Automação , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Próstata/diagnóstico por imagem , Algoritmos , Artérias/diagnóstico por imagem , Artefatos , Calibragem , Meios de Contraste/farmacologia , Compressão de Dados , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Masculino , Reconhecimento Automatizado de Padrão , Estudos Retrospectivos
6.
Radiographics ; 40(2): 354-375, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31951512

RESUMO

Representatives from the Society of Abdominal Radiology Crohn's Disease-Focused Panel, the Society for Pediatric Radiology, the American Gastroenterological Association, and other international experts recently reported consensus recommendations for standardized nomenclature for the interpretation and reporting of CT enterography and MR enterography findings of small bowel Crohn disease. The consensus recommendations included CT enterography and MR enterography bowel wall findings that are associated with Crohn disease, findings that occur with penetrating Crohn disease, and changes that occur in the mesentery related to Crohn disease. Also included were recommended radiology report impression statements that summarize the findings of small bowel Crohn disease at CT enterography and MR enterography. This article, authored by the Society of Abdominal Radiology Crohn's Disease-Focused Panel, illustrates the imaging findings and recommended radiology report impression statements described in the consensus recommendations with examples of CT enterography and MR enterography images. Additional interpretation guidelines for reporting CT enterography and MR enterography examinations are also presented. The recommended standardized nomenclature can be used to generate radiology report dictations that will help guide medical and surgical management for patients with small bowel Crohn disease. Online supplemental material is available for this article. ©RSNA, 2020See discussion on this article by Heverhagen.


Assuntos
Doença de Crohn/diagnóstico por imagem , Intestino Delgado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Terminologia como Assunto , Tomografia Computadorizada por Raios X , Humanos
7.
J Magn Reson Imaging ; 50(5): 1633-1640, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30854767

RESUMO

BACKGROUND: Quantifying the biomechanical properties of pancreatic tumors could potentially help with assessment of tumor aggressiveness, prognosis, and prediction of therapy response. PURPOSE: To quantify respiratory-induced deformation in the pancreas and pancreatic lesions using XD-GRASP (eXtra-Dimensional Golden-angle RAdial Sparse Parallel), MRI. STUDY TYPE: Retrospective study where patients undergoing clinically indicated abdominal MRI which included free-breathing radial T1 -weighted (T1 W) imaging were studied. SUBJECTS: Thirty-two patients (12 male and 20 female) including nine with pancreatic lesions constituted our study cohort. FIELD STRENGTH/SEQUENCE: 3.0 T with T1 WI contrast-enhanced gradient echo radial free-breathing acquisition. ASSESSMENT: Using the XD-GRASP imaging technique, the acquired free-breathing radial data were sorted and binned into 10 consecutive respiratory motion states that were jointly reconstructed. 3D deformation fields along the respiratory dimension were computed using an optical flow method and were analyzed in the pancreas. STATISTICAL TESTS: The Wilcoxon signed-rank test was used to assess the difference in average displacement across pancreatic regions, while the Wilcoxon rank-sum test was used for displacement differences between patients with and without tumors. The interclass correlation coefficient (ICC) was computed to assess consistency between observers for each image quality measure. RESULTS: There was a significantly larger displacement in the pancreatic tail compared with the head (8.2 ± 3.7 mm > 5.8 ± 2.4 mm; P < 0.001) and body regions (8.2 ± 3.7 mm > 6.6 ± 2.9 mm; P < 0.001). Furthermore, there was reduced normalized average displacement in patients with pancreatic lesions compared with subjects without lesions (0.33 ± 0.1 < 0.69 ± 0.26, P < 0.001 for the head; 0.30 ± 0.1 < 0.84 ± 0.31, P < 0.001 for the body; and 0.44 ± 0.31 < 1.08 ± 0.53, P < 0.001 for the tail, respectively). DATA CONCLUSION: Free-breathing respiratory motion-sorted XD-GRASP MRI has the potential to noninvasively characterize the biomechanical properties of the pancreas by quantifying breathing-induced mechanical displacement. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:1633-1640.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Pâncreas/diagnóstico por imagem , Pâncreas/fisiopatologia , Neoplasias Pancreáticas/diagnóstico por imagem , Idoso , Algoritmos , Artefatos , Suspensão da Respiração , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Neoplasias Pancreáticas/fisiopatologia , Prognóstico , Respiração , Estudos Retrospectivos
8.
J Magn Reson Imaging ; 50(5): 1614-1619, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30990941

RESUMO

BACKGROUND: Evaluation of prostate MRI relies on diffusion-weighted imaging (DWI), commonly distorted by susceptibility artifacts, thereby creating a need for approaches to correct such distortion. PURPOSE: To compare geometric distortion on prostate MRI between standard DWI and a geometric distortion correction method for DWI described as static distortion correction DWI (SDC DWI). STUDY TYPE: Retrospective case study. POPULATION: Thirty patients (ages 31-81 years) undergoing prostate MRI. SEQUENCE: Geometric distortions from echo planar imaging were corrected with the SDC DWI protocol, which first acquires a B0 -field map to estimate geometric distortions. ASSESSMENT: Contours of the prostate were placed on axial T2 -weighted imaging (T2 WI) as an anatomic standard. Pixel shifts and apparent diffusion coefficient (ADC) values were compared between prostate contours applied to the SDC DWI and standard DWI sequences. Detailed characterization of the impact of SDC DWI was performed in three representative patients. STATISTICAL TESTS: One-way analysis of variance (ANOVA) test, Spearman correlation test, and Bland-Altman plots were calculated. RESULTS: There was significantly greater overlap of the SDC DWI prostate region of interest (ROI) with T2 WI than standard DWI with T2 WI (10.56 cm2 ± 3.14, P < 0.05). R2 of ADC values from standard DWI vs. SDC DWI in the 30 patients ranged from 0.02-0.94 (mean 0.60). A patient without susceptibility artifact demonstrated minimal pixel shift ranging from 0.6-1.3 mm and high correlation of ADC values (R2 = 0.89) between SDC DWI and standard DWI. A patient with rectal gas showed greater pixel shift (range: -2.5 to -0.5 mm) and less ADC value correlation (R2 = 0.69). A patient with a pelvic phlebolith adjacent to the prostate showed an even greater pixel shift (range: 10-16 mm) and decreased ADC correlation (R2 = 0.21). DATA CONCLUSION: SDC DWI appears to correct for susceptibility-related pixel shifts in the prostate compared with standard DWI, which may have value for assessing prostate lesions obscured by geometric warping. Level of Evidence 4 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2019;50:1614-1619.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Ultrassonografia
9.
J Magn Reson Imaging ; 49(7): e282-e294, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30637854

RESUMO

BACKGROUND: Uterine fibroids are a common benign tumor and can be symptomatic, necessitating resection. Surgical myomectomy is an effective treatment option with a risk of disseminating occult uterine leiomyosarcoma (LMS), creating a need for an effective presurgical screening protocol. Clinical collaboration with contrast-enhanced MRI including T2 and diffusion-weighted imaging (DWI) can be utilized as a screening exam. PURPOSE: To review the accuracy and feasibility of an interdisciplinary prospective contrast-enhanced MRI pelvis with DWI screening system for LMS prior to fibroid resection. STUDY TYPE: Retrospective cohort study. POPULATION: In all, 1960 adult female patients aged 18-87 undergoing screening MRI pelvis prior to uterine fibroid resection. FIELD STRENGTH/SEQUENCE: T1 and T2 -weighted imaging, DWI, and contrast-enhanced images were acquired at 1.5 T and 3.0 T. ASSESSMENT: Each radiologist at the time of clinical study prospectively designated a confidence level of presence of LMS in the impression, which was reviewed retrospectively. A separate retrospective evaluation of the histologically proven LMS and the false positives was performed for the presence of five MRI features of LMS including low ADC values, intermediate/high T2 signal intensity, irregular margins, hemorrhage, and necrosis. A preliminary cost-effectiveness analysis was performed, comparing the costs of treatment of uterine fibroids with vs. without a collaborative screening protocol using MRI. STATISTICAL TESTS: Sensitivity, specificity, positive predictive value, and negative predictive value were obtained from the prospective evaluations. Student's t-tests were used to compare demographics and apparent diffusion coefficient values between LMS and false-positive results. RESULTS: We prospectively identified LMS patients with 100% sensitivity and 97% specificity. Preliminary cost analysis demonstrated that the MR screening protocol increased life expectancy by 0.04 years at a cost of $12,937 per life-year gained. DATA CONCLUSION: MRI is an effective and potentially economic screening test, especially with standardized reporting and coordination with clinicians. LEVEL OF EVIDENCE: 3 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2019.


Assuntos
Leiomioma/diagnóstico por imagem , Leiomiossarcoma/diagnóstico por imagem , Imageamento por Ressonância Magnética , Neoplasias Uterinas/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
10.
Magn Reson Med ; 80(1): 286-293, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29193380

RESUMO

PURPOSE: Golden-angle radial sparse parallel (GRASP) MRI reconstruction requires gridding and regridding to transform data between radial and Cartesian k-space. These operations are repeatedly performed in each iteration, which makes the reconstruction computationally demanding. This work aimed to accelerate GRASP reconstruction using self-calibrating GRAPPA operator gridding (GROG) and to validate its performance in clinical imaging. METHODS: GROG is an alternative gridding approach based on parallel imaging, in which k-space data acquired on a non-Cartesian grid are shifted onto a Cartesian k-space grid using information from multicoil arrays. For iterative non-Cartesian image reconstruction, GROG is performed only once as a preprocessing step. Therefore, the subsequent iterative reconstruction can be performed directly in Cartesian space, which significantly reduces computational burden. Here, a framework combining GROG with GRASP (GROG-GRASP) is first optimized and then compared with standard GRASP reconstruction in 22 prostate patients. RESULTS: GROG-GRASP achieved approximately 4.2-fold reduction in reconstruction time compared with GRASP (∼333 min versus ∼78 min) while maintaining image quality (structural similarity index ≈ 0.97 and root mean square error ≈ 0.007). Visual image quality assessment by two experienced radiologists did not show significant differences between the two reconstruction schemes. With a graphics processing unit implementation, image reconstruction time can be further reduced to approximately 14 min. CONCLUSION: The GRASP reconstruction can be substantially accelerated using GROG. This framework is promising toward broader clinical application of GRASP and other iterative non-Cartesian reconstruction methods. Magn Reson Med 80:286-293, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Idoso , Algoritmos , Calibragem , Meios de Contraste , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Imagens de Fantasmas , Radiologia , Cintilografia , Estudos Retrospectivos , Software
11.
Magn Reson Med ; 80(1): 77-89, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29193260

RESUMO

PURPOSE: To develop and evaluate a novel dynamic contrast-enhanced imaging technique called RACER-GRASP (Respiratory-weighted, Aortic Contrast Enhancement-guided and coil-unstReaking Golden-angle RAdial Sparse Parallel) MRI that extends GRASP to include automatic contrast bolus timing, respiratory motion compensation, and coil-weighted unstreaking for improved imaging performance in liver MRI. METHODS: In RACER-GRASP, aortic contrast enhancement (ACE) guided k-space sorting and respiratory-weighted sparse reconstruction are performed using aortic contrast enhancement and respiratory motion signals extracted directly from the acquired data. Coil unstreaking aims to weight multicoil k-space according to streaking artifact level calculated for each individual coil during image reconstruction, so that coil elements containing a high level of streaking artifacts contribute less to the final results. Self-calibrating GRAPPA operator gridding was applied as a pre-reconstruction step to reduce computational burden in the subsequent iterative reconstruction. The RACER-GRASP technique was compared with standard GRASP reconstruction in a group of healthy volunteers and patients referred for clinical liver MR examination. RESULTS: Compared with standard GRASP, RACER-GRASP significantly improved overall image quality (average score: 3.25 versus 3.85) and hepatic vessel sharpness/clarity (average score: 3.58 versus 4.0), and reduced residual streaking artifact level (average score: 3.23 versus 3.94) in different contrast phases. RACER-GRASP also enabled automatic timing of the arterial phases. CONCLUSIONS: The aortic contrast enhancement-guided sorting, respiratory motion suppression and coil unstreaking introduced by RACER-GRASP improve upon the imaging performance of standard GRASP for free-breathing dynamic contrast-enhanced MRI of the liver. Magn Reson Med 80:77-89, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Aorta/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Respiração , Adulto , Algoritmos , Artefatos , Suspensão da Respiração , Análise por Conglomerados , Simulação por Computador , Meios de Contraste , Compressão de Dados , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Adulto Jovem
13.
AJR Am J Roentgenol ; 210(1): 113-117, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29045185

RESUMO

OBJECTIVE: The purpose of this study was to compare the reproducibility and diagnostic performance of 2D and 3D ROIs for prostate apparent diffusion coefficient (ADC) measurements. MATERIALS AND METHODS: The study included 56 patients with prostate cancer undergoing 3-T MRI including DWI (b = 50 and 1000 s/mm2) before radical prostatectomy. Histologic findings from prostatectomy specimens were reviewed to denote each patient's dominant tumor and a benign region with visually decreased ADC. Three readers independently measured the ADCs of both areas using an ROI placed on a single slice through the lesion (2D) and an ROI encompassing all slices through the lesion (3D). Readers repeated measurements after 3 weeks. Assessment included Bland-Altman analysis (coefficient of repeatability [CR] in which lower values indicated higher reliability) and ROC analysis. RESULTS: For intrareader variability, the CRs across readers for all ROIs were 9.9% for 2D and 9.3% for 3D. For tumor ROIs the CRs were 10.6% for 2D and 9.6% for 3D. For interreader variability, the CRs across readers for all ROIs were 17.1% for 2D and 20.5% for 3D and for tumor ROIs were 17.9% for 2D and 22.2% for 3D. For combined reader data, the AUCs for benign and malignant findings were 0.77 for 2D and 0.78 for 3D (p = 0.146). For differentiating Gleason score (GS) 3 + 3 from GS > 3 + 3 tumors, the AUCs were 0.92 for 2D and 0.92 for 3D ROIs (p = 0.649). For differentiating GS ≤ 3 + 4 from GS ≥ 4 + 3 tumors, the AUCs were 0.70 for 2D and 0.67 for 3D ROIs (p = 0.004). CONCLUSION: Use of a 3D ROI did not improve intrareader or interreader reproducibility or diagnostic performance compared with use of a 2D ROI for prostate ADC measurements. Interreader reproducibility of 2D ROIs was suboptimal nonetheless.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Prostatectomia , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos
14.
Abdom Radiol (NY) ; 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38935092

RESUMO

Acute and chronic bowel pathologies can often be mistaken for manifestations of inflammatory bowel disease (IBD), and there are many entities with imaging and clinical features that overlap with IBD, making diagnosis difficult. We describe multiple inflammatory, infectious, neoplastic, and vascular entities with imaging and clinical features that may mimic IBD, and highlight differentiating features to assist in diagnosis.

15.
Abdom Radiol (NY) ; 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630314

RESUMO

PURPOSE: To compare the inter-reader agreement of pancreatic adenocarcinoma resectability assessment at pancreatic protocol photon-counting CT (PCCT) with conventional energy-integrating detector CT (EID-CT). METHODS: A retrospective single institution database search identified all contrast-enhanced pancreatic mass protocol abdominal CT performed at an outpatient facility with both a PCCT and EID-CT from 4/11/2022 to 10/30/2022. Patients without pancreatic adenocarcinoma were excluded. Four fellowship-trained abdominal radiologists, blinded to CT type, independently assessed vascular tumor involvement (uninvolved, abuts ≤ 180°, encases > 180°; celiac, superior mesenteric artery (SMA), common hepatic artery (CHA), superior mesenteric vein (SMV), main portal vein), the presence/absence of metastases, overall tumor resectability (resectable, borderline resectable, locally advanced, metastatic), and diagnostic confidence. Fleiss's kappa was used to calculate inter-reader agreement. CTDIvol was recorded. Radiation dose metrics were compared with a two-sample t-test. A p < .05 indicated statistical significance. RESULTS: 145 patients (71 men, mean[SD] age: 66[9] years) were included. There was substantial inter-reader agreement, for celiac artery, SMA, and SMV involvement at PCCT (kappa = 0.61-0.69) versus moderate agreement at EID-CT (kappa = 0.56-0.59). CHA had substantial inter-reader agreement at both PCCT (kappa = 0.67) and EIDCT (kappa = 0.70). For metastasis identification, radiologists had substantial inter-reader agreement at PCCT (kappa = 0.78) versus moderate agreement at EID-CT (kappa = 0.56). CTDIvol for PCCT and EID-CT were 16.9[7.4]mGy and 29.8[26.6]mGy, respectively (p < .001). CONCLUSION: There was substantial inter-reader agreement for involvement of 4/5 major peripancreatic vessels (celiac artery, SMA, CHA, and SMV) at PCCT compared with 2/5 for EID-CT. PCCT also afforded substantial inter-reader agreement for metastasis detection versus moderate agreement at EID-CT with statistically significant radiation dose reduction.

16.
Abdom Radiol (NY) ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38888739

RESUMO

OBJECTIVE: To retrospectively compare inter- and intra-reader agreement of abbreviated MRCP (aMRCP) with comprehensive MRI (cMRCP) protocol for detection of worrisome features, high-risk stigmata, and concomitant pancreatic cancer in pancreatic cyst surveillance. METHODS: 151 patients (104 women, mean age: 69[10] years) with baseline and follow-up contrast-enhanced MRIs were included. This comprised 138 patients under cyst surveillance with 5-year follow-up showing no pancreatic ductal adenocarcinoma (PDAC), 6 with pancreatic cystic lesion-derived malignancy, and 7 with concomitant PDAC. The aMRCP protocol used four sequences (axial and coronal Half-Fourier Single-shot Turbo-spin-Echo, axial T1 fat-saturated pre-contrast, and 3D-MRCP), while cMRCP included all standard sequences, including post-contrast. Three blinded abdominal radiologists assessed baseline cyst characteristics, worrisome features, high-risk stigmata, and PDAC signs using both aMRCP and cMRCP, with a 2-week washout period. Intra- and inter-reader agreement were calculated using Fleiss' multi-rater kappa and Intra-class Correlation Coefficient (ICC). 95% confidence intervals (CI) were calculated. RESULTS: Cyst size, growth, and abrupt main pancreatic duct transition had strong intra- and inter-reader agreement. Intra-reader agreement was ICC = 0.93-0.99 for cyst size, ICC = 0.71-1.00 for cyst growth, and kappa = 0.83-1.00 for abrupt duct transition. Inter-reader agreement for cyst size was ICC = 0.86 (aMRCP) and ICC = 0.83 (cMRCP), and for abrupt duct transition was kappa = 0.84 (aMRCP) and kappa = 0.69 (cMRCP). Thickened cyst wall, mural nodule and cyst-duct communication demonstrated varying intra-reader agreements and poor inter-reader agreements. CONCLUSION: aMRCP showed high intra- and inter-reader agreement for most pancreatic cyst parameters that highly rely on T2-weighted sequences.

17.
J Am Coll Radiol ; 21(6S): S249-S267, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38823948

RESUMO

Cervical cancer is a common gynecological malignancy worldwide. Cervical cancer is staged based on the International Federation of Gynecology and Obstetrics (FIGO) classification system, which was revised in 2018 to incorporate radiologic and pathologic data. Imaging plays an important role in pretreatment assessment including initial staging and treatment response assessment of cervical cancer. Accurate determination of tumor size, local extension, and nodal and distant metastases is important for treatment selection and for prognostication. Although local recurrence can be diagnosed by physical examination, imaging plays a critical role in detection and follow-up of local and distant recurrence and subsequent treatment selection. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Assuntos
Sociedades Médicas , Neoplasias do Colo do Útero , Humanos , Feminino , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/patologia , Estados Unidos , Invasividade Neoplásica , Estadiamento de Neoplasias , Medicina Baseada em Evidências
18.
Abdom Radiol (NY) ; 48(9): 2944-2955, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36740604

RESUMO

Ileal pouch surgery is the surgical gold standard treatment for patients with ulcerative colitis (UC) and familial adenomatous polyposis (FAP). However, ileal pouch surgery is a technically challenging procedure and is associated with high morbidity. Clinical presentations of pouch complications are often nonspecific but imaging can identify many of these complications and is essential in clinical management. This paper will focus on magnetic resonance imaging (MRI) of the ileal pouch, including recommended MRI protocol and approach to imaging interpretation with an emphasis on those ileal pouch complications particularly well evaluated with MRI.


Assuntos
Polipose Adenomatosa do Colo , Colite Ulcerativa , Bolsas Cólicas , Proctocolectomia Restauradora , Humanos , Proctocolectomia Restauradora/métodos , Bolsas Cólicas/efeitos adversos , Polipose Adenomatosa do Colo/diagnóstico por imagem , Polipose Adenomatosa do Colo/cirurgia , Polipose Adenomatosa do Colo/etiologia , Colite Ulcerativa/diagnóstico por imagem , Colite Ulcerativa/cirurgia , Imageamento por Ressonância Magnética
19.
Magn Reson Imaging ; 97: 56-67, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36577458

RESUMO

This work aimed to develop a modified stack-of-stars golden-angle radial sampling scheme with variable-density acceleration along the slice (kz) dimension (referred to as VD-stack-of-stars) and to test this new sampling trajectory with multi-coil compressed sensing reconstruction for rapid motion-robust 3D liver MRI. VD-stack-of-stars sampling implements additional variable-density undersampling along the kz dimension, so that slice resolution (or volumetric coverage) can be increased without prolonging scan time. The new sampling trajectory (with increased slice resolution) was compared with standard stack-of-stars sampling with fully sampled kz (with standard slice resolution) in both non-contrast-enhanced free-breathing liver MRI and dynamic contrast-enhanced MRI (DCE-MRI) of the liver in volunteers. For both sampling trajectories, respiratory motion was extracted from the acquired radial data, and images were reconstructed using motion-compensated (respiratory-resolved or respiratory-weighted) dynamic radial compressed sensing reconstruction techniques. Qualitative image quality assessment (visual assessment by experienced radiologists) and quantitative analysis (as a metric of image sharpness) were performed to compare images acquired using the new and standard stack-of-stars sampling trajectories. Compared to standard stack-of-stars sampling, both non-contrast-enhanced and DCE liver MR images acquired with VD-stack-of-stars sampling presented improved overall image quality, sharper liver edges and increased hepatic vessel clarity in all image planes. The results have suggested that the proposed VD-stack-of-stars sampling scheme can achieve improved performance (increased slice resolution or volumetric coverage with better image quality) over standard stack-of-stars sampling in free-breathing DCE-MRI without increasing scan time. The reformatted coronal and sagittal images with better slice resolution may provide added clinical value.


Assuntos
Aumento da Imagem , Imageamento Tridimensional , Humanos , Imageamento Tridimensional/métodos , Aumento da Imagem/métodos , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Respiração , Artefatos
20.
Gastrointest Endosc Clin N Am ; 33(3): 497-518, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37245932

RESUMO

The detection of incidental pancreatic cystic lesions has increased over time. It is crucial to separate benign from potentially malignant or malignant lesions to guide management and reduce morbidity and mortality. The key imaging features used to fully characterize cystic lesions are optimally assessed by contrast-enhanced magnetic resonance imaging/magnetic resonance cholangiopancreatography, with pancreas protocol computed tomography offering a complementary role. While some imaging features have high specificity for a particular diagnosis, overlapping imaging features between diagnoses may require further investigation with follow-up diagnostic imaging or tissue sampling.


Assuntos
Cisto Pancreático , Neoplasias Pancreáticas , Humanos , Imageamento por Ressonância Magnética/métodos , Neoplasias Pancreáticas/patologia , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Colangiopancreatografia por Ressonância Magnética , Cisto Pancreático/diagnóstico por imagem , Cisto Pancreático/patologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa