Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Sensors (Basel) ; 23(12)2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37420700

RESUMO

This communication investigated the dust effect on microelectromechanical system (MEMS) thermal wind sensors, with an aim to evaluate performance in practical applications. An equivalent circuit was established to analyze the temperature gradient influenced by dust accumulation on the sensor's surface. The finite element method (FEM) simulation was carried out to verify the proposed model using COMSOL Multiphysics software. In experiments, dust was accumulated on the sensor's surface by two different methods. The measured results indicated that the output voltage for the sensor with dust on its surface was a little smaller than that of the sensor without dust at the same wind speed, which can degrade the measurement sensitivity and accuracy. Compared to the sensor without dust, the average voltage was reduced by about 1.91% and 3.75% when the dustiness was 0.04 g/mL and 0.12 g/mL, respectively. The results can provide a reference for the actual application of thermal wind sensors in harsh environments.


Assuntos
Poeira , Sistemas Microeletromecânicos , Poeira/análise , Vento , Temperatura , Software
2.
Sensors (Basel) ; 23(11)2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-37299917

RESUMO

Parity-time (PT) symmetry challenges the long-held theoretical basis that only Hermitian operators correspond to observable phenomena in quantum mechanics. Non-Hermitian Hamiltonians satisfying PT symmetry also have a real-valued energy spectrum. In the field of inductor-capacitor (LC) passive wireless sensors, PT symmetry is mainly used for improving performance in terms of multi-parameter sensing, ultrahigh sensitivity, and longer interrogation distance. For example, the proposal of both higher-order PT symmetry and divergent exceptional points can utilize a more drastic bifurcation process around exceptional points (EPs) to accomplish a significantly higher sensitivity and spectral resolution. However, there are still many controversies regarding the inevitable noise and actual precision of the EP sensors. In this review, we systematically present the research status of PT-symmetric LC sensors in three working areas: exact phase, exceptional point, and broken phase, demonstrating the advantages of non-Hermitian sensing concerning classical LC sensing principles.


Assuntos
Registros , Feminino , Gravidez , Humanos , Paridade
3.
J Nanobiotechnology ; 20(1): 171, 2022 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-35361237

RESUMO

BACKGROUND: Budding yeast, Saccharomyces cerevisiae, has been extensively favored as a model organism in aging and age-related studies, thanks to versatile microfluidic chips for cell dynamics assay and replicative lifespan (RLS) determination at single-cell resolution. However, previous microfluidic structures aiming to immobilize haploid yeast may impose excessive spatial constraint and mechanical stress on cells, especially for larger diploid cells that sprout in a bipolar pattern. RESULTS: We developed a high-throughput microfluidic chip for diploid yeast long-term culturing (DYLC), optical inspection and cell-aging analysis. The DYLC chip features 1100 "leaky bowl"-shaped traps formatted in an array to dock single cells under laminar-perfused medium and effectively remove daughter cells by hydraulic shear forces. The delicate microstructures of cell traps enable hydrodynamic rotation of newborn buds, so as to ensure bud reorientation towards downstream and concerted daughter dissection thereafter. The traps provide sufficient space for cell-volume enlargement during aging, and thus properly alleviate structural compression and external stress on budding yeast. Trapping efficiency and long-term maintenance of single cells were optimized according to computational fluid dynamics simulations and experimental characterization in terms of critical parameters of the trap and array geometries. Owing to the self-filling of daughter cells dissected from traps upstream, an initial trapping efficiency of about 70% can rapidly reach a high value of over 92% after 4-hour cell culturing. During yeast proliferation and aging, cellular processes of growth, budding and daughter dissection were continuously tracked for over 60 h by time-lapse imaging. Yeast RLS and budding time interval (BTI) were directly calculated by the sequential two-digit codes indicating the budding status in images. With the employed diploid yeast strain, we obtained an RLS of 24.29 ± 3.65 generations, and verified the extension of BTI in the first couple of generations after birth and the last several generations approaching death, as well as cell de-synchronization along diploid yeast aging. CONCLUSIONS: The DYLC chip offers a promising platform for reliable capture and culturing of diploid yeast cells and for life-long tracking of cell dynamics and replicative aging processes so that grasping comprehensive insights of aging mechanism in complex eukaryotic cells.


Assuntos
Microfluídica , Saccharomyces cerevisiae , Divisão Celular , Diploide , Humanos , Recém-Nascido , Longevidade , Microfluídica/métodos
4.
Electrophoresis ; 42(20): 1996-2009, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33938013

RESUMO

High-resolution microscopic imaging may cause intensive image processing and potential impact of light irradiation on yeast replicative lifespan (RLS). Electrical impedance spectroscopy (EIS) could be alternatively used to perform high-throughput and label-free yeast RLS assays. Prior to fabricating EIS-integrated microfluidic devices for yeast RLS determination, systematic modeling and theoretical investigation are crucial for device design and optimization. Here, we report three-dimensional (3D) finite-element modeling and simulations of EIS measurement in a microfluidic single yeast in situ impedance array (SYIIA), which is designed by patterning an electrode matrix underneath a cell-trapping array. SYIIA was instantiated and modeled as a 5 × 5 sensing array comprising 25 units for cell immobilization, culturing, and time-lapse EIS recording. Simulations of yeast growing and budding in a sensing unit demonstrated that EIS signals enable the characterization of cell growth and daughter-cell dissections. In the 5 × 5 sensing array, simulation results indicated that when monitoring a target cell, daughter dissections in its surrounding traps may induce variations of the recorded EIS signals, which could cause mistakes in identifying target daughter-cell dissections. To eliminate the mis-identifications, electrode array pitch was optimized. Therefore, the results could conduct the design and optimization of microfluidic electrode-array-integrated devices for high-throughput and accurate yeast RLS assays.


Assuntos
Microfluídica , Saccharomyces cerevisiae , Impedância Elétrica , Eletrodos , Análise de Célula Única
5.
Sensors (Basel) ; 21(15)2021 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-34372356

RESUMO

Porous polytetrafluoroethylene (PTFE) is physically flexible, thermally and chemically stable, relatively inexpensive, and commercially available. It is attractive for various flexible sensors. This paper has studied flexible capacitive humidity sensors fabricated on porous PTFE substrates. Graphene oxide (GO) was used as a sensing material, both hydrophobic and hydrophilic porous PTFE as the substrates, and interdigitated electrodes on the PTFE substrates were screen-printed. SEM and Raman spectrum were utilized to characterize GO and PTFE. An ethanol soak process is developed to increase the yield of the humidity sensors based on hydrophobic porous PTFE substrates. Static and dynamic properties of these sensors are tested and analyzed. It demonstrates that the flexible capacitive humidity sensors fabricated on the ethanol-treated hydrophobic PTFE exhibit high sensitivity, small hysteresis, and fast response/recovery time.

6.
Sensors (Basel) ; 21(23)2021 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-34884058

RESUMO

This article presents a method for detecting rotational speed by LC (inductor-capacitor) wireless sensors. The sensing system consists of two identical LC resonant tanks. One is mounted on the rotating part and the other, as a readout circuit, is placed right above the rotating part. When the inductor on the rotating part is coaxially aligned with the readout inductor during rotation, the mutual coupling between them reaches the maximum, resulting in a peak amplitude induced at the readout LC tank. The period of the readout signal corresponds to the rotation speed. ADS (Advanced Design System) software was used to simulate and optimize the sensing system. A synchronous detection circuit was designed. The rotational speed of an electric was measured to validate this method experimentally, and the results indicated that the maximum error of the rotation speed from 16 rps to 41 rps was 0.279 rps.


Assuntos
Eletricidade , Tecnologia sem Fio
7.
Sensors (Basel) ; 17(11)2017 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-29117096

RESUMO

A microstructure beam is one of the fundamental elements in MEMS devices like cantilever sensors, RF/optical switches, varactors, resonators, etc. It is still difficult to precisely predict the performance of MEMS beams with the current available simulators due to the inevitable process deviations. Feasible numerical methods are required and can be used to improve the yield and profits of the MEMS devices. In this work, process deviations are considered to be stochastic variables, and a newly-developed numerical method, i.e., generalized polynomial chaos (GPC), is applied for the simulation of the MEMS beam. The doubly-clamped polybeam has been utilized to verify the accuracy of GPC, compared with our Monte Carlo (MC) approaches. Performance predictions have been made on the residual stress by achieving its distributions in GaAs Monolithic Microwave Integrated Circuit (MMIC)-based MEMS beams. The results show that errors are within 1% for the results of GPC approximations compared with the MC simulations. Appropriate choices of the 4-order GPC expansions with orthogonal terms have also succeeded in reducing the MC simulation labor. The mean value of the residual stress, concluded from experimental tests, shares an error about 1.1% with that of the 4-order GPC method. It takes a probability around 54.3% for the 4-order GPC approximation to attain the mean test value of the residual stress. The corresponding yield occupies over 90 percent around the mean within the twofold standard deviations.

8.
Sensors (Basel) ; 16(8)2016 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27490546

RESUMO

Passive wireless sensors have the advantages of operating without a power supply and remote sensing capability. Hence, they are very suitable for some harsh environments, such as hermetic environments, rotating parts, or very high temperature environments. The spray painting workshop is such a harsh environment, containing a large amount of flammable paint mist and organic gas. Aiming at this special environment of spray painting workshop, a passive wireless hermetic environment monitoring system was designed, fabricated, and demonstrated. The proposed system is composed of a transponder and a reader, and the circuit design of each part is given in detail in this paper. The power and the data transmission between the transponder and the reader are realized by the inductive coupling mechanism. Utilizing the back scatter modulation and channel multiplexing, the frequency signals generated by three different environmental sensors-together with their interfaces in the transponder-are wirelessly read out by the reader. Because of the harsh environment of the spray painting room, the package of the monitoring system is quite important. Three different kinds of filter films for the system package were compared. The experimental results show that the composite filter film aluminum anodic oxide/polytetrafluoroethylene (AAO/PTFE) has the best performance. After fabrication, the measured temperature, humidity, and pressure sensitivities were measured and found to be 180 Hz/°C in the range of 0~60 °C, 100 Hz/%RH in the range of 15~95 %RH, and 42 Hz/hPa in the range of 600~1100 hPa, respectively. Additionally, the remote sensing distance of the monitoring system reaches 4 cm. Finally, the passive wireless hermetic environment monitoring system was installed on the glass wall of the spray painting workshop and was successfully demonstrated.

9.
Sensors (Basel) ; 15(12): 29871-81, 2015 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-26633398

RESUMO

For a two-dimensional solid silicon thermal wind sensor with symmetrical structure, the wind speed and direction information can be derived from the output voltages in two orthogonal directions, i.e., the north-south and east-west. However, the output voltages in these two directions will vary linearly with the ambient temperature. Therefore, in this paper, a temperature model to study the temperature effect on the wind direction measurement has been developed. A theoretical analysis has been presented first, and then Finite Element Method (FEM) simulations have been performed. It is found that due to symmetrical structure of the thermal wind sensor, the temperature effects on the output signals in the north-south and east-west directions are highly similar. As a result, the wind direction measurement of the thermal wind sensor is approximately independent of the ambient temperature. The experimental results fit the theoretical analysis and simulation results very well.

10.
Clin Cosmet Investig Dermatol ; 17: 649-652, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38505807

RESUMO

We describe a case involving a 19-year-old female with who presented with bilateral nipple-areola brown patches persisting for five years. The diagnosis of hyperkeratosis of the nipple and areola (HNA) was established through dermoscopy and histopathology. The findings highlight the value of dermoscopy in the diagnosis and differentiation of HNA.

11.
Clin Cosmet Investig Dermatol ; 17: 117-123, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38250638

RESUMO

Superficial Acral fibroma (SAF), also known as osteofibroma, is a rare fibromatous tumor primarily involving superficial soft tissues. Clinically, SAF typically manifests as a slow-growing, solitary, well-defined nodule or mass. Although these lesions are generally asymptomatic, some cases may present with associated pain, often linked to a history of trauma. SAF lesions commonly exhibit hemispherical, polypoid, or warty growths, with occasional occurrences of ulceration and bleeding.The majority of SAFs express CD34 and CD99, but in the two cases we report, there was diffuse expression of CD34 and focal positive expression of CD68. CD68 positivity suggests a propensity for tumor cells to metastasize to secondary sites. Notably, previously reported cases of single SAF did not display positive CD68 expression, indicating a potential association with other aggressive tumors. However, the current clinical and pathological manifestations do not clarify the diagnosis of additional malignant tumors. Consequently, regular postoperative monitoring of the patient from the aforementioned two cases is essential to detect the presence of other malignant tumors. The significance of CD68-positive expression in this case lies in its potential association with such tumors.

12.
Microsyst Nanoeng ; 10: 12, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38261878

RESUMO

Exceptional points (EPs) have recently emerged as a new method for engineering the response of open physical systems, that is, systems that interact with the environment. The systems at the EPs exhibit a strong response to a small perturbation. Here, we show a method by which the sensitivity of silicon resonant sensors can be enhanced when operated at EPs. In our experiments, we use a pair of mechanically coupled silicon micromechanical resonators constituting a parity-time (PT)-symmetric dimer. Small perturbations introduced on the mechanically coupled spring cause the frequency to split from the EPs into the PT-symmetric regime without broadening the two spectrum linewidths, and this frequency splitting scales with the square root of the perturbation strength. The overall signal-to-noise ratio is still greatly enhanced, although the measured noise spectral density of the EP sensing scheme has a slight increase comparable to the traditional counterpart. Our results pave the way for resonant sensors with ultrahigh sensitivity.

13.
Micromachines (Basel) ; 15(5)2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38793229

RESUMO

Partial discharge (PD) is the dominant insulating defect in Gas-Insulated Switchgear (GIS). The existing detection methods are mainly divided into built-in wire-connected disk antennas with destructive drilling and external ultra-high frequency antennas with poor anti-interference ability. This research introduces a passive wireless PD sensor implanted inside GIS on the observation window. The sensor is implemented by a sheeting branch-inductor with multiple resonances which is able to enhance detection sensitivity. A coaxially aligned readout circuit, positioned outside the GIS, interrogates the PD sensor to wirelessly obtain the PD signal. The proposed sensing scheme improves signal-to-noise ratio and ensures minimal disruption to the electric field distribution inside GIS. An experimental setup was established in a controlled laboratory environment to benchmark the multi-resonant sensor against the commercial UHF sensor. A 2.5-times enhancement of signal strength was observed. Since our sensor was implanted inside the GIS, a high signal-to-noise ratio (68.82 dB) was obtained. Moreover, we constructed a wireless calibration test to investigate the accuracy of the proposed sensor. The precision of the signal test was as high as 0.72 pC. The pulse phase distribution information was collected to demonstrate a phase-resolved partial discharge (PRPD) pattern. The experiment results validate the effectiveness of the proposed method and demonstrate excellent performance in PD detection.

14.
Nanoscale ; 15(8): 4045-4052, 2023 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-36728990

RESUMO

In recent years, two-dimensional (2D) multifunctional materials have become a research hotpot for their wide application range. In this work, PbGe(CN)2 and PbGe(C2H)2 are predicted to realize the piezoelectricity, quantum spin Hall (QSH) insulator, and Rashba effects simultaneously. The topological bandgaps of PbGe(CN)2 and PbGe(C2H)2 are 0.418 and 0.405 eV, respectively, which are much larger than the recently reported value of 0.165 eV for InTeO that can also attain both the piezoelectricity and QSH insulator (PQSHI) effects. The in-plane and out-of-plane piezoelectric effects coexist in both PbGe(CN)2 and PbGe(C2H)2 with the in-plane piezoelectric coefficients d11 of 8.823 and 2.913 pm V-1 and out-of-plane piezoelectric coefficients d31 of 0.638 and 0.608 pm V-1. It is worth noting that there are significant Rashba SOC effects in PbGe(CN)2 and PbGe(C2H)2 and their Rashba splitting parameters are 2.576 and 2.184 eV Å, respectively. The prominent Rashba effects, which don't exist in other PQSHI materials, make PbGe(CN)2 and PbGe(C2H)2 more suitable for application in spintronic devices. Besides, the topological properties can remain robust under the uniaxial strain within the range of -6% to 6%. Our results imply that PbGe(CN)2 and PbGe(C2H)2 qualify as potential candidates for low-power, highly sensitive piezoelectric devices, such as pressure sensors for converting mechanical energy into electrical energy.

15.
Clin Cosmet Investig Dermatol ; 16: 1019-1023, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37089910

RESUMO

We describe a 39-year-old woman with a 1-month-old linear erythema diagnosed with cutaneous larva migrans by reflectance confocal microscopy (RCM). This case reveals that the great significance of diagnosing and treating cutaneous larva migrans (CLM) by RCM and dermoscopy, which might provide novel insights into dermatological clinical practice.

16.
Micromachines (Basel) ; 11(11)2020 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-33138304

RESUMO

Due to the increasing complexity of microelectromechanical system (MEMS) devices, the accuracy and precision of two-dimensional microstructures of SU-8 negative thick photoresist have drawn more attention with the rapid development of UV lithography technology. This paper presents a high-precision lithography simulation model for thick SU-8 photoresist based on waveguide method to calculate light intensity in the photoresist and predict the profiles of developed SU-8 structures in two dimension. This method is based on rigorous electromagnetic field theory. The parameters that have significant influence on profile quality were studied. Using this model, the light intensity distribution was calculated, and the final resist morphology corresponding to the simulation results was examined. A series of simulations and experiments were conducted to verify the validity of the model. The simulation results were found to be in good agreement with the experimental results, and the simulation system demonstrated high accuracy and efficiency, with complex cases being efficiently handled.

17.
ACS Sens ; 5(7): 2036-2043, 2020 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-32519548

RESUMO

Currently, the use of electrical readout methods for the investigation of microtissue spheroids in combination with lab automation tools is hindered by the cable connections that are required to interrogate the on-chip-integrated electrodes. To overcome this limitation, we developed a wireless sensor scheme, which can detect the size variation of microtissues during long-term culturing and drug exposure assays. The sensor system includes an interrogation board, which is composed of an inductor-capacitor (LC) readout circuit, and the tissue culture platform with integrated split-ring sensors. The magnetic coupling between the LC circuit and the sensors enables the interrogation of the on-chip sensors without any wire connection to the culture platform. By optimizing the sensor dimensions and the LC resonance frequencies, we were able to avoid cross talk between neighboring sensors. We integrated 12 tissue compartments on a standard microscopy slide with a sensor-to-sensor pitch of 9 mm, which is in accordance with standard 96-well plate dimensions. As a proof-of-concept experiment for the developed system, we monitored continuously and during more than four days the growth inhibition of colon cancer microtissue spheroids that had been exposed to different concentrations of doxorubicin, a chemotherapeutic compound. The stability of the measurements during long-term culturing and the compatibility of the sensor scheme with standard lab equipment offer great potential for automated electrical microtissue spheroid characterization.

18.
Sensors (Basel) ; 9(4): 2746-59, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-22574043

RESUMO

In order to design and optimize high-sensitivity silicon nanowire-field-effect transistor (SiNW FET) pressure sensors, this paper investigates the effects of channel orientations and the uniaxial stress on the ballistic hole transport properties of a strongly quantized SiNW FET placed near the high stress regions of the pressure sensors. A discrete stress-dependent six-band k.p method is used for subband structure calculation, coupled to a two-dimensional Poisson solver for electrostatics. A semi-classical ballistic FET model is then used to evaluate the ballistic current-voltage characteristics of SiNW FETs with and without strain. Our results presented here indicate that [110] is the optimum orientation for the p-type SiNW FETs and sensors. For the ultra-scaled 2.2 nm square SiNW, due to the limit of strong quantum confinement, the effect of the uniaxial stress on the magnitude of ballistic drive current is too small to be considered, except for the [100] orientation. However, for larger 5 nm square SiNW transistors with various transport orientations, the uniaxial tensile stress obviously alters the ballistic performance, while the uniaxial compressive stress slightly changes the ballistic hole current. Furthermore, the competition of injection velocity and carrier density related to the effective hole masses is found to play a critical role in determining the performance of the nanotransistors.

19.
Micromachines (Basel) ; 10(10)2019 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-31581644

RESUMO

Various multilayered thin films are extensively used as the basic component of some micro-electro-mechanical systems, requiring an efficient measurement method for material parameters, such as Young's modulus, residual stress, etc. This paper developed a novel measurement method to extract the Young's moduli and residual stresses for individual layers in multilayered thin films, based on the first resonance frequency measurements of both cantilever beams and doubly-clamped beams. The fabrication process of the test structure, the corresponding modeling and the material parameter extraction process are introduced. To verify this method, the test structures with gold/polysilicon bilayer beams are fabricated and tested. The obtained Young's moduli of polysilicon films are from 151.38 GPa to 154.93GPa, and the obtained Young's moduli of gold films are from 70.72 GPa to 75.34GPa. The obtained residual stresses of polysilicon films are from -14.86 MPa to -13.11 MPa (compressive stress), and the obtained residual stresses of gold films are from 16.27 to 23.95 MPa (tensile stress). The extracted parameters are within the reasonable ranges, compared with the available results or the results obtained by other test methods.

20.
Sci Adv ; 5(8): eaav9653, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31414044

RESUMO

Wearable human-machine interfaces (HMIs) are an important class of devices that enable human and machine interaction and teaming. Recent advances in electronics, materials, and mechanical designs have offered avenues toward wearable HMI devices. However, existing wearable HMI devices are uncomfortable to use and restrict the human body's motion, show slow response times, or are challenging to realize with multiple functions. Here, we report sol-gel-on-polymer-processed indium zinc oxide semiconductor nanomembrane-based ultrathin stretchable electronics with advantages of multifunctionality, simple manufacturing, imperceptible wearing, and robust interfacing. Multifunctional wearable HMI devices range from resistive random-access memory for data storage to field-effect transistors for interfacing and switching circuits, to various sensors for health and body motion sensing, and to microheaters for temperature delivery. The HMI devices can be not only seamlessly worn by humans but also implemented as prosthetic skin for robotics, which offer intelligent feedback, resulting in a closed-loop HMI system.


Assuntos
Nanoestruturas/química , Semicondutores , Dispositivos Eletrônicos Vestíveis , Géis , Índio , Polímeros , Óxido de Zinco
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa