Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
1.
J Sep Sci ; 41(23): 4281-4285, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30267460

RESUMO

A liquid chromatographic chiral stationary phase, which contains two N-CH3 amide connecting groups, based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid was first applied to the resolution of methoxyphenamine (2-methoxy-N-methylamphetamine, a ß-adrenergic receptor agonist used as a bronchodilator). The resolution of methoxyphenamine on the chiral stationary phase containing two N-CH3 amide connecting groups was quite successful with the separation factor (α) of 1.42 and resolution (RS ) of 4.22 compared with those (α of 1.09 and RS of 1.55) on the chiral stationary phase containing two N-H amide connecting groups. In addition, the chiral stationary phase containing two N-CH3 amide connecting groups was applied to the resolution of methoxyphenamine analogues. From the comparison of the resolution results of methoxyphenamine with those of methoxyphenamine analogues on the chiral stationary phase containing two N-CH3 amide connecting groups, the N-methyl group and the 2-methoxyphenyl group of methoxyphenamine were elucidated to be the structurally essential parts for the resolution on the chiral stationary phase.


Assuntos
Éteres de Coroa/química , Metanfetamina/análogos & derivados , Cromatografia Líquida de Alta Pressão , Metanfetamina/química , Metanfetamina/isolamento & purificação , Estrutura Molecular
2.
J Sep Sci ; 41(6): 1192-1198, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29044998

RESUMO

Two liquid chromatographic chiral stationary phases based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid were applied to the resolution of the amide derivatives of cyclic α-amino acids including proline and pipecolic acid. Among the five amide derivatives of proline, aniline amide was resolved best on the first chiral stationary phase, which contains two N-H tethering amide groups, with the separation factor of 1.31 and the resolution of 2.60, and on the second chiral stationary phase, which contains two N-CH3 tethering amide groups, with the separation factor of 1.57 and the resolution of 5.50. Among the five amide derivatives of pipecolic acid, 2-naphthyl amide was resolved best on the first chiral stationary phase with the separation factor of 1.30 and the resolution of 1.75, but 1-naphthylmethyl amide was resolved best on the second chiral stationary phase with the separation factor of 1.30 and the resolution of 2.26. In general, the second chiral stationary phase was found to be better than the first chiral stationary phase in the resolution of the amide derivatives of cyclic α-amino acids. In this study, the second chiral stationary phase was first demonstrated to be useful for the resolution of secondary amino compounds.


Assuntos
Éteres de Coroa/química , Ácidos Pipecólicos/isolamento & purificação , Prolina/isolamento & purificação , Cromatografia Líquida de Alta Pressão , Estrutura Molecular , Ácidos Pipecólicos/química , Prolina/química , Estereoisomerismo
3.
Chirality ; 28(3): 253-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26726053

RESUMO

A new chiral stationary phase (CSP) based on macrocyclic amide receptor was prepared starting from (1R,2R)-1,2-diphenylethylenediamine. The new CSP was successfully applied to the resolution of various N-(substituted benzoyl)-α-amino amides with reasonably good separation factors and resolutions (α = 1.75 ~ 2.97 and RS = 2.89 ~ 6.82 for 16 analytes). The new CSP was also applied to the resolution of 3-substituted 1,4-benzodiazepin-2-ones and some diuretic chiral drugs including bendroflumethiazide and methylchlothiazide and metolazone. The resolution results for 3-substituted 1,4-benzodiazepin-2-ones and some diuretic chiral drugs were also reasonably good.

4.
Molecules ; 21(8)2016 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-27529205

RESUMO

Two new diastereomeric chiral stationary phases (CSPs) based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid as a chiral tethering group and a Π-basic chiral unit such as (R)-1-(1-naphthyl)ethylamine (CSP 1) or (S)-1-(1-naphthyl)ethylamine (CSP 2) were prepared. The two CSPs were applied to the enantiomeric separation of N-(3,5-dinitrobenzoyl)-1-phenylalkylamines and N-(3,5-dinitrobenzoyl)-α-amino acid derivatives using 20% isopropyl alcohol in hexane as a normal mobile phase. To elucidate the effect of the two chiral units on the chiral recognition, the chiral recognition abilities of the two CSPs were compared with each other and with that of a CSP (CSP 3) based on (R)-1-(1-naphthyl)ethylamine. From the chromatographic chiral recognition results, (R)-1-(1-naphthyl)ethylamine and (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid constituting CSP 1 were concluded to show a cooperative ("matched") effect on the chiral recognition while (S)-1-(1-naphthyl)ethylamine and (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid constituting CSP 2 were concluded to show an uncooperative ("mismatched") effect on the chiral recognition. From these results, it was concluded that (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid can be successfully used as a chiral tethering group for the preparation of new CSPs.


Assuntos
Éteres de Coroa/química , Etilaminas/química , Naftalenos/química , Cromatografia Líquida de Alta Pressão , Espectroscopia de Ressonância Magnética , Estrutura Molecular , Estereoisomerismo
5.
Chirality ; 27(9): 576-88, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26237013

RESUMO

Crown ether-based chiral stationary phases (CSPs) have been known to be useful for the resolution of racemic primary amino compounds. In particular, CSPs based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid have been reported to be useful for the resolution of secondary amino compounds as well as primary amino compounds. In this article, the process of developing various CSPs based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid to improve the chiral recognition efficiency and/or the stability of the CSPs and their applications to the resolution of various primary and nonprimary amino compounds are reviewed.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Éteres de Coroa/química , Estereoisomerismo
6.
Chirality ; 27(3): 268-73, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25626672

RESUMO

Valacyclovir, a potential prodrug for the treatment of patients with herpes simplex and herpes zoster, and its analogs were resolved on two chiral stationary phases (CSPs) based on (3,3'-diphenyl-1,1'-binaphthyl)-20-crown-6 covalently bonded to silica gel. In order to find out an appropriate mobile phase condition, various mobile phases consisting of various organic modifiers in water containing various acidic modifiers were applied to the resolution of valacyclovir and its analogs. When 30% acetonitrile in water containing any of 0.05 M, 0.10 M, or 0.15 M perchloric acid was used as a mobile phase, valacyclovir and its analogs were resolved quite well on the two CSPs with the separation factors (α) in the range of 2.49 ~ 6.35 and resolutions (RS ) in the range of 2.95 ~ 12.21. Between the two CSPs, the CSP containing residual silanol protecting n-octyl groups on the silica surface was found to be better than the CSP containing residual silanol groups.


Assuntos
Aciclovir/análogos & derivados , Aciclovir/química , Antivirais/química , Cromatografia Líquida de Alta Pressão/métodos , Valina/análogos & derivados , Ésteres/química , Concentração de Íons de Hidrogênio , Estereoisomerismo , Valaciclovir , Valina/química
7.
Analyst ; 139(6): 1420-5, 2014 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-24482801

RESUMO

Point-of-care testing (POCT) of biomarkers in clinical samples is of great importance for rapid and cost-effective diagnosis. However, it is extremely challenging to develop an electrochemical POCT technique retaining both ultrasensitivity and simplicity. We report an interference-free electrochemical lateral-flow immunoassay that enables one-step ultrasensitive detection with serum. The electrochemical-chemical-chemical (ECC) redox cycling combined with an enzymatic reaction of an enzyme label is used to obtain high signal amplification. The ECC redox cycling involving Ru(NH3)6(3+), enzyme product, and tris(3-carboxyethyl)phosphine (TCEP) depends on pH, because the formal potentials of an enzyme product and TCEP increase with decreasing pH although that of Ru(NH3)6(3+) is pH-independent. With consideration of the pH dependence of ECC redox cycling, a noble combination of enzyme label, substrate, and product [ß-galactosidase, 4-amino-1-naphthyl ß-D-galactopyranoside, and 4-amino-1-naphthol, respectively] is introduced to ensure fast and selective ECC redox cycling of the enzyme product along with a low background level. The selective ECC redox cycling at a low applied potential (0.05 V vs. Ag/AgCl) minimizes the interference effect of electroactive species (L-ascorbic acid, acetaminophen, and uric acid) in serum. A detection limit of 0.1 pg mL(-1) for troponin I is obtained only 11 min after serum dropping without the use of an additional solution. Moreover, the lateral-flow immunoassay is applicable to the analysis of real clinical samples.


Assuntos
Técnicas Eletroquímicas/instrumentação , Imunoensaio/instrumentação , Troponina I/sangue , Técnicas Biossensoriais/economia , Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/economia , Desenho de Equipamento , Humanos , Imunoensaio/economia , Limite de Detecção , Sistemas Automatizados de Assistência Junto ao Leito/economia
8.
Chirality ; 26(5): 272-8, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24677299

RESUMO

Mexiletine, an effective class IB antiarrhythmic agent, and its analogs were resolved on three different crown ether-based chiral stationary phases (CSPs), one (CSP 1) of which is based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid and the other two (CSP 2 and CSP 3) are based on (3,3'-diphenyl-1,1'-binaphthyl)-20-crown-6. Mexiletine was resolved with a resolution (R(S)) of greater than 1.00 on CSP 1 and CSP 3 containing residual silanol group-protecting n-octyl groups on the silica surface, but with a resolution (R(S)) of less than 1.00 on CSP 2. The chromatographic behaviors for the resolution of mexiletine analogs containing a substituted phenyl group at the chiral center on the three CSPs were quite dependent on the phenoxy group of analytes. Namely, mexiletine analogs containing 2,6-dimethylphenoxy, 3,4-dimethylphenoxy, 3-methylphenoxy, 4-methylphenoxy, and a simple phenoxy group were resolved very well on the three CSPs even though the chiral recognition efficiencies vary with the CSPs. However, mexiletine analogs containing 2-methylphenoxy group were not resolved at all or only slightly resolved. Among the three CSPs, CSP 3 was found to show the highest chiral recognition efficiencies for the resolution of mexiletine and its analogs, especially in terms of resolution (R(S)).


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Éteres de Coroa/química , Mexiletina/química , Mexiletina/isolamento & purificação , Mexiletina/análogos & derivados , Estereoisomerismo
9.
Molecules ; 19(12): 21386-97, 2014 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-25532838

RESUMO

Fendiline, an effective anti-anginal drug for the treatment of coronary heart diseases, and its sixteen analogues were resolved on a CSP based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid. Fendiline was resolved quite well with the separation factor (α) of 1.25 and resolution (RS) of 1.55 when a mobile phase consisting of methanol-acetonitrile-trifluoroacetic acid-triethylamine at a ratio of 80/20/0.1/0.5 (v/v/v/v) was used. The comparison of the chromatographic behaviors for the resolution of fendiline and its analogues indicated that the 3,3-diphenylpropyl group bonded to the secondary amino group of fendiline is important in the chiral recognition and the difference in the steric bulkiness between the phenyl group and the methyl group at the chiral center of fendiline is also important in the chiral recognition.


Assuntos
Fármacos Cardiovasculares/isolamento & purificação , Éteres de Coroa/química , Fendilina/análogos & derivados , Fendilina/isolamento & purificação , Acetonitrilas/química , Cromatografia Líquida , Etilaminas/química , Metanol/química , Solventes/química , Ácido Trifluoracético/química
10.
Anal Chem ; 85(3): 1631-6, 2013 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-23327094

RESUMO

Signal amplification by enzyme labels in enzyme-linked immunosorbent assays (ELISAs) is not sufficient for detecting a low number of bacterial pathogens. It is useful to employ approaches that involve multiple signal amplification such as enzymatic amplification plus redox cycling. An advantageous combination of an enzyme product [for fast electrochemical-chemical-chemical (ECC) redox cycling that involves the product] and an enzyme substrate (for slow side reactions and ECC redox cycling that involve the substrate) has been developed to obtain a low detection limit for E. coli O157:H7 in an electrochemical ELISA that employs redox cycling. In our search for an alkaline phosphatase substrate/product couple that is better than the most common couple of 4-aminophenyl phosphate (APP)/4-aminophenol (AP), we compared five couples: APP/AP, hydroquinone diphosphate (HQDP)/hydroquinone (HQ), L-ascorbic acid 2-phosphate/L-ascorbic acid, 4-amino-1-naphthyl phosphate/4-amino-1-naphthol, and 1-naphthyl phosphate/1-naphthol. In particular, we examined signal-to-background ratios in ECC redox cycling using Ru(NH(3))(6)(3+) and tris(2-carboxyethyl)phosphine as an oxidant and a reductant, respectively. The ECC redox cycling that involves HQ is faster than the cycling that involves AP, whereas the side reactions and ECC redox cycling that involve HQDP are negligible compared to the APP case. These results seem to be due to the fact that the formal potential of HQ is lower than that of AP and that the formal potential of HQDP is higher than that of APP. Enzymatic amplification plus ECC redox cycling based on a HQDP/HQ couple allows us to detect E. coli O157:H7 in a wide range of concentrations from 10(3) to 10(8) colony-forming units/mL.


Assuntos
Técnicas Eletroquímicas/métodos , Escherichia coli O157/isolamento & purificação , Escherichia coli O157/metabolismo , Hidroquinonas/metabolismo , Organofosfatos/metabolismo , Amplificação de Genes/fisiologia , Hidroquinonas/química , Organofosfatos/química , Oxirredução , Monoéster Fosfórico Hidrolases/química , Monoéster Fosfórico Hidrolases/metabolismo , Especificidade por Substrato/fisiologia
11.
Chirality ; 25(5): 294-300, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23620265

RESUMO

In the present work, we report a comprehensive vibrational circular dichroism (VCD) spectroscopic study of a chiral crown ether which features an axial chiral 3.3'-diphenyl-1,1'-binaphthyl group as chiral moiety. By comparing the experimental and calculated VCD spectra, we show that the presumably very flexible crown ether preferably adopts only one ring conformation. Conformational flexibility is observed in the 2,4-dinitrophenyl-diazophenol group, which was previously introduced for colorimetric detection of primary amines and amino alcohols (Cho et al., Chirality 2011;23:349-353). The VCD spectra of the host-guest complexes with phenyl glycinol (PG) and phenyl alaninol have been studied as well. Based on the spectra calculated, it is shown that the diastereomeric complexes in general can be differentiated using VCD spectroscopy. Furthermore, the experimental VCD spectra of the complexes of the host molecule with PG support the above finding.

12.
J Sep Sci ; 36(23): 3682-7, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24106082

RESUMO

A liquid chromatographic chiral stationary phase based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid was applied to the resolution of 15 analytes, including racemic rasagiline, a chiral drug for the treatment of Parkinson's disease, and its analogues. The composition of mobile phase was optimized to be ethanol/acetonitrile/acetic acid/triethylamine (80:20:0.2:0.3, v/v/v/v) by evaluating the chromatographic results for the resolution of five selected analytes under various mobile phase conditions. Under the optimized mobile phase conditions, racemic rasagiline was resolved quite well with a separation factor of 1.48 and resolution of 2.71 and its 14 analogues were also resolved reasonably well with separation factors of 1.06-1.54 and resolutions of 0.54-2.11. Among 15 analytes, racemic rasagiline was resolved best except for just one analyte. The analyte structure-enantioselectivity relationship indicated that racemic rasagiline has the most appropriate structural characteristics for resolution on the chiral stationary phase.


Assuntos
Cromatografia Líquida , Éteres de Coroa/química , Indanos/química , Antiparkinsonianos/química , Estrutura Molecular , Estereoisomerismo
13.
J Sep Sci ; 36(8): 1349-55, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23420568

RESUMO

A new ligand exchange chiral stationary phase (new CSP) containing residual silanol group-protecting n-octyl groups on the silica surface was prepared by treating a ligand exchange CSP (original CSP) based on sodium N-[(R)-2-hydroxy-1-phenylethyl]-N-undecylaminoacetate bonded to silica gel with excess n-octyltriethoxysilane. The new and original CSPs containing an identical amount of chiral selector were applied to the resolution of α-amino acids and proton pump inhibitors (PPIs) including omeprazole, pantoprazole, lansoprazole, and rabeprazole. The separation factors (α) and resolutions (RS) were greater on the new CSP than on the original CSP except for the resolution of asparagine. The trends of the retention factors (k1) for the resolution of α-amino acids on the new and original CSPs with the variation of the organic modifier content in aqueous mobile phase were opposite to those for the resolution of PPIs. Removal of the nonenantioselective interactions between the residual silanol groups and the analytes and the improved lipophilicity of the new CSP were proposed to be responsible for the improved chiral recognition ability of the new CSP and the different retention behaviors of the enantiomers between the new and original CSPs.


Assuntos
Aminoácidos/química , Cromatografia Líquida/métodos , Inibidores da Bomba de Prótons , Silanos/química , Ligantes
14.
J Sep Sci ; 36(8): 1335-42, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23512817

RESUMO

The application of a chiral ligand-exchange column for the direct high-performance liquid chromatographic enantioseparation of unusual ß-amino acids with a sodium N-((R)-2-hydroxy-1-phenylethyl)-N-undecylaminoacetate-Cu(II) complex as chiral selector is reported. The investigated amino acids were isoxazoline-fused 2-aminocyclopentanecarboxylic acid analogs. The chromatographic conditions were varied to achieve optimal separation. The effects of temperature were studied at constant mobile phase compositions in the temperature range 5-45°C, and thermodynamic parameters were calculated from plots of lnk or lnα versus 1/T. Δ(ΔH°) ranged from -2.3 to 2.2 kJ/mol, Δ(ΔS°) from -3.0 to 7.8 J mol(-1) K(-1) and -Δ(ΔG°) from 0.1 to 1.7 kJ/mol, and both enthalpy- and entropy-controlled enantioseparations were observed. The latter was advantageous with regard to the shorter retention and greater selectivity at high temperature. Some mechanistic aspects of the chiral recognition process are discussed with respect to the structures of the analytes. The sequence of elution of the enantiomers was determined in all cases.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cicloleucina/análogos & derivados , Isoxazóis/química , Cicloleucina/química , Ligantes , Estereoisomerismo , Termodinâmica
15.
Chirality ; 24(5): 406-11, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22514035

RESUMO

A new 7-nitrobenz-2-oxa-1,3-diazole (NBD)-based fluorescent chiral chemosensor (NBD-1) was prepared and applied to the recognition of the two enantiomers of the tetrabutylammonium salts of N-t-Boc-α-amino acids and chiral carboxylic acids including naproxen. In particular, the chiral recognition by the new fluorescent chiral chemosensor for the two enantiomers of N-t-Boc-threonine (tetrabutylammonium salt) was quite excellent, the Stern-Volmer constant ratio (K(D)/K(L)) for the two enantiomers being as high as 4.89.


Assuntos
Aminoácidos/análise , Ácidos Carboxílicos/análise , Técnicas de Química Analítica/métodos , Corantes Fluorescentes/química , Aminoácidos/química , Ácidos Carboxílicos/química , Estrutura Molecular , Naproxeno/análise , Naproxeno/química , Oxidiazóis/química , Compostos de Amônio Quaternário/química , Espectrofotometria Ultravioleta , Estereoisomerismo , Treonina/química
16.
Chirality ; 24(5): 427-31, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22508444

RESUMO

3-Amino-5-phenyl (or 5-methyl)-1,4-benzodiazepin-2-ones, which are chiral precursors of anti-respiratory syncytial virus active agents, were resolved on three different chiral stationary phases (CSPs) based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid or (3,3'-diphenyl-1,1'-binaphthyl)-20-crown-6. Among the three CSPs, the CSP that is based on (3,3'-diphenyl-1,1'-binaphthyl)-20-crown-6 and containing residual silanol group-protecting n-octyl groups on the silica surface was found to be most effective with the use of 80% ethanol in water containing perchloric acid (10 mM) and ammonium acetate (1.0 mM) as a mobile phase. The separation factors (α) and resolutions (R(S) ) were in the range of 1.90-3.21 and 2.79-5.96, respectively. From the relationship between the analyte structure and the chromatographic resolution behavior, the chiral recognition mechanism on the CSP based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid was proposed to be different from that on the CSP based on (3,3'-diphenyl-1,1'-binaphthyl)-20-crown-6. In addition, the chromatographic resolution behavior of the most effective CSP was investigated as a function of the composition of aqueous mobile phase containing organic and acidic modifier and ammonium acetate.


Assuntos
Benzodiazepinas/química , Cromatografia Líquida/métodos , Éteres de Coroa/química , Acetatos/química , Estrutura Molecular , Silanos/química , Estereoisomerismo
17.
Chirality ; 24(10): 817-24, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22847684

RESUMO

The enantiomers of four unusual isoxazoline-fused 2-aminocyclopentanecarboxylic acids were directly separated on chiral stationary phases containing (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid as chiral selector. The nature of the alcoholic modifier (MeOH, EtOH, IPA) exerted a great effect on the retention, whereas the selectivity and resolution did not change substantially. Two types of dependence of retention on alcohol content were detected: k(1) increased continuously with increasing alcohol content or a U-shaped retention curve was observed. A comparison of the chromatographic data obtained with HCOOH, AcOH, TFA, HClO(4), H(2)SO(4), or H(3)PO(4) as acidic modifier at a constant concentration demonstrated that in most cases, larger k values were obtained on the application of AcOH or HCOOH, and an increase of the acid content resulted in a decrease of retention. Some mechanistic aspects of the chiral recognition process are discussed with respect to the structures of the analytes and selector. The sequence of elution of the enantiomers was determined in all cases.


Assuntos
Cromatografia Líquida de Alta Pressão , Éteres de Coroa/química , Cicloleucina/química , Peptídeos Cíclicos/química , Estereoisomerismo
18.
Anal Chem ; 83(10): 3926-33, 2011 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-21486093

RESUMO

The authors herein report optimized conditions for ultrasensitive phosphatase-based immunosensors (using redox cycling by a reducing agent) that can be simply prepared and readily applied to microfabricated electrodes. The optimized conditions were applied to the ultrasensitive detection of cardiac troponin I in human serum. The preparation of an immunosensing layer was based on passive adsorption of avidin (in carbonate buffer (pH 9.6)) onto indium-tin oxide (ITO) electrodes. The immunosensing layer allows very low levels of nonspecific binding of proteins. The optimum conditions for the enzymatic reaction were investigated in terms of the type of buffer solution, temperature, and concentration of MgCl(2), and the optimum conditions for antigen-antibody binding were determined in terms of incubation time, temperature, and concentration of phosphatase-conjugated IgG. Very importantly, the antigen-antibody binding at 4 °C is extremely important in obtaining reproducible results. Among the four phosphatase substrates (L-ascorbic acid 2-phosphate (AAP), 4-aminophenyl phosphate, 1-naphthyl phosphate, 4-amino-1-naphthyl phosphate) and four phosphatase products (L-ascorbic acid (AA), 4-aminophenol, 1-naphthol, 4-amino-1-naphthol), AAP and AA meet the requirements most for obtaining easy dissolution and high signal-to-background ratios. More importantly, fast AA electrooxidation at the ITO electrodes does not require modification with any electrocatalyst or electron mediator. Furthermore, tris(2-carboxyethyl)phosphine (TCEP) as a reducing agent allows fast redox cycling, along with very low anodic currents at the ITO electrodes. Under these optimized conditions, the detection limit of an immunosensor for troponin I obtained without redox cycling of AA by TCEP is ca. 100 fg/mL, and with redox cycling it is ca. 10 fg/mL. A detection limit of 10 fg/mL was also obtained even when an immunosensing layer was simply formed on a micropatterned ITO electrode. From a practical point of view, it is of great importance that ultralow detection limits can be obtained with simply prepared enzyme-based immunosensors.


Assuntos
Técnicas Biossensoriais/métodos , Imunoensaio/métodos , Monoéster Fosfórico Hidrolases/metabolismo , Troponina I/sangue , Fosfatase Alcalina/química , Fosfatase Alcalina/metabolismo , Anticorpos/imunologia , Avidina/química , Técnicas Eletroquímicas/métodos , Eletrodos , Humanos , Cloreto de Magnésio/química , Oxirredução , Monoéster Fosfórico Hidrolases/química , Temperatura , Compostos de Estanho/química
19.
Chirality ; 23 Suppl 1: E16-21, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21365690

RESUMO

The two enantiomers of N-acyl amide and N-ureide derivatives of 3-amino-5-phenyl-1,4-benzodiazepin-2-ones, which have been known to show anti-respiratory syncytial virus (RSV) activity, were resolved on seven different Pirkle-type chiral stationary phases (CSPs) with the use of 10% isopropyl alcohol in hexane as a mobile phase. Among the seven Pirkle-type CSPs, the one based on (S)-leucine derivative named as N-Phe-L-Leu was found to be most successful, the separation factors (α) and the resolutions (R(S) ) for seven analytes being in the range of 1.78-4.21 and 5.94-15.08, respectively. By resolving N-benzyloxycarbonyl derivatives of 3-amino-5-phenyl(or 5-methyl)-1,4-benzodiazepin-2-ones on Pirkle-type CSPs, the phenyl ring at the 5-position and the NH hydrogen at the 1-position of analytes were found to play an important role in the chiral recognition.


Assuntos
Benzodiazepinas/química , Benzodiazepinonas/química , Cromatografia Líquida/métodos , Álcoois/química , Cromatografia/métodos , Cromatografia Líquida de Alta Pressão/métodos , Hidrogênio/química , Leucina/química , Modelos Químicos , Nitrogênio/química , Espectrofotometria Ultravioleta/métodos , Estereoisomerismo
20.
Chirality ; 23(4): 281-6, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20928896

RESUMO

(R)-N-3,5-dinitrobenzoyl (DNB) leucine derived chiral selector was used as an HPLC chiral stationary phase for the resolution of various racemic amino acids derivatives. In this study, determination of optical purity of an amino acid derivative was performed by chiral high performance liquid chromatography and 1H and 13C NMR spectroscopy by using the DNB leucine derived chiral selector. The accuracy and precision of each optical purity value are calculated and the data are compared to each other.


Assuntos
Aminoácidos/química , Cromatografia Líquida de Alta Pressão/métodos , Hidrogênio/química , Leucina/análogos & derivados , Espectroscopia de Ressonância Magnética/métodos , Aminoácidos/síntese química , Isótopos de Carbono/química , Cromatografia/métodos , Dinitrobenzenos , Indicadores e Reagentes , Cinética , Leucina/química , Estrutura Molecular , Sensibilidade e Especificidade , Estereoisomerismo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa