1.
Biotechnol Bioeng ; 120(10): 2989-3000, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37309984

RESUMO

The implementation of continuous processing in the biopharmaceutical industry is hindered by the scarcity of process analytical technologies (PAT). To monitor and control a continuous process, PAT tools will be crucial to measure real-time product quality attributes such as protein aggregation. Miniaturizing these analytical techniques can increase measurement speed and enable faster decision-making. A fluorescent dye (FD)-based miniaturized sensor has previously been developed: a zigzag microchannel which mixes two streams under 30 s. Bis-ANS and CCVJ, two established FDs, were employed in this micromixer to detect aggregation of the biopharmaceutical monoclonal antibody (mAb). Both FDs were able to robustly detect aggregation levels starting at 2.5%. However, the real-time measurement provided by the microfluidic sensor still needs to be implemented and assessed in an integrated continuous downstream process. In this work, the micromixer is implemented in a lab-scale integrated system for the purification of mAbs, established in an ÄKTA™ unit. A viral inactivation and two polishing steps were reproduced, sending a sample of the product pool after each phase directly to the microfluidic sensor for aggregate detection. An additional UV sensor was connected after the micromixer and an increase in its signal would indicate that aggregates were present in the sample. The at-line miniaturized PAT tool provides a fast aggregation measurement, under 10 min, enabling better process understanding and control.


Assuntos
Anticorpos Monoclonais , Produtos Biológicos , Tecnologia
2.
Biotechnol Bioeng ; 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37458361

RESUMO

The methodology for production of biologics is going through a paradigm shift from batch-wise operation to continuous production. Lot of efforts are focused on integration, intensification, and continuous operation for decreased foot-print, material, equipment, and increased productivity and product quality. These integrated continuous processes with on-line analytics become complex processes, which requires automation, monitoring, and control of the operation, even unmanned or remote, which means bioprocesses with high level of automation or even autonomous capabilities. The development of these digital solutions becomes an important part of the process development and needs to be assessed early in the development chain. This work discusses a platform that allows fast development, advanced studies, and validation of digital solutions for integrated continuous downstream processes. It uses an open, flexible, and extendable real-time supervisory controller, called Orbit, developed in Python. Orbit makes it possible to communicate with a set of different physical setups and on the same time perform real-time execution. Integrated continuous processing often implies parallel operation of several setups and network of Orbit controllers makes it possible to synchronize complex process system. Data handling, storage, and analysis are important properties for handling heterogeneous and asynchronous data generated in complex downstream systems. Digital twin applications, such as advanced model-based and plant-wide monitoring and control, are exemplified using computational extensions in Orbit, exploiting data and models. Examples of novel digital solutions in integrated downstream processes are automatic operation parameter optimization, Kalman filter monitoring, and model-based batch-to-batch control.

3.
Biotechnol Bioeng ; 119(8): 2152-2166, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35470430

RESUMO

In this study, we demonstrated the first, to our knowledge, integrated continuous bioprocess (ICB) designed for the production of acid-sensitive monoclonal antibodies, prone to aggregate at low pH, on pilot scale. A high cell density perfusion culture, stably maintained at 100 × 106 cells/ml, was integrated with the downstream process, consisting of a capture step with the recently developed Protein A ligand, ZCa ; a solvent/detergent-based virus inactivation; and two ion-exchange chromatography steps. The use of a mild pH in the downstream process makes this ICB suitable for the purification of acid-sensitive monoclonal antibodies. Integration and automation of the downstream process were achieved using the Orbit software, and the same equipment and control system were used in initial small-scale trials and the pilot-scale downstream process. High recovery yields of around 90% and a productivity close to 1 g purified antibody/L/day were achieved, with a stable glycosylation pattern and efficient removal of impurities, such as host cell proteins and DNA. Finally, negligible levels of antibody aggregates were detected owing to the mild conditions used throughout the process. The present work paves the way for future industrial-scale integrated continuous biomanufacturing of all types of antibodies, regardless of acid stability.


Assuntos
Anticorpos Monoclonais , Animais , Anticorpos Monoclonais/biossíntese , Anticorpos Monoclonais/química , Reatores Biológicos , Células CHO , Cricetinae , Cricetulus , Proteína Estafilocócica A/química
4.
J Chromatogr A ; 1695: 463942, 2023 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-37015183

RESUMO

Buffer management for biopharmaceutical purification processes include buffer preparation, storage of buffers and restocking the buffers when needed. This is usually performed manually by the operators for small scale operations. However, buffer management can become a bottleneck when running integrated continuous purification processes for prolonged times, even at small scale. To address this issue, a buffer management system for the application in continuous lab-scale bioprocessing is presented in this paper. For this purpose, an ÄKTA™ explorer chromatography system was reconfigured to perform the buffer formulation. The system formulated all buffers from stock solutions and water according to pre-specified recipes. A digital twin of the physical system was introduced in the research software Orbit, written in python. Orbit was also used for full automation and control of the buffer system, which could run independently without operator input and handle buffer management for one or several connected buffer-consuming purification systems. The developed buffer management system performed automatic monitoring of buffer volumes, buffer order handling as well as buffer preparation and delivery. To demonstrate the capability of the developed system, it was integrated with a continuous downstream process and supplied all 9 required buffers to the process equipment during a 10-day operation. The buffer management system processed 55 orders and delivered 38 L of buffers, corresponding to 20% of its capacity. The pH and conductivity profiles observed during the purification steps were consistent across the cycles. The deviation in conductivity and pH from the measured average value was within ±0.89% in conductivity and ±0.045 in pH, well within the typical specification for buffer release, indicating that the prepared buffers had the correct composition. The operation of the developed buffer management system was robust and fully automated, and provides one solution to the buffer management bottleneck on lab scale for integrated continuous downstream bioprocessing.


Assuntos
Cromatografia , Água , Soluções Tampão , Cromatografia/métodos , Automação
5.
J Chromatogr A ; 1664: 462806, 2022 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-35033788

RESUMO

Monoclonal antibodies (mAb) are used as therapeutics and for diagnostics of a variety of diseases, and novel antibodies are continuously being developed to find treatments for new diseases. Therefore, the manufacturing process must accommodate a range of mAb characteristics. Acid-sensitive mAbs can severely compromise product purity and yield in the purification process due to the potential formation of aggregates. To address this problem, we have developed an integrated downstream process for the purification of pH-sensitive mAbs at mild conditions. A calcium-dependent Protein A-based ligand, called ZCa, was used in the capture step in a 3-column periodic counter-current chromatography operation. The binding of ZCa to antibodies is regulated by calcium, meaning that acidic conditions are not needed to break the interaction and elute the antibodies. Further, the virus inactivation was achieved by a solvent/detergent method, where the pH could remain unchanged. The polishing steps included a cation and an anion exchange chromatography step, and screening of the capture and polishing steps was performed to allow for a seamless integration of the process steps. The process was implemented at laboratory scale for 9 days obtaining a high yield, and a consistently pure drug substance, including high reduction values of the host cell protein and DNA concentrations, as well as aggregate levels below the detection limit, which is attributed to the mild conditions used in the process.


Assuntos
Anticorpos Monoclonais , Proteína Estafilocócica A , Animais , Células CHO , Cálcio , Cromatografia , Cricetinae , Ligantes
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa