Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Artif Organs ; 47(9): 1442-1451, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37376726

RESUMO

BACKGROUND: Extracorporeal organ assist devices provide lifesaving functions for acutely and chronically ill patients suffering from respiratory and renal failure, but their availability and use is severely limited by an extremely high level of operational complexity. While current hollow fiber-based devices provide high-efficiency blood gas transfer and waste removal in extracorporeal membrane oxygenation (ECMO) and hemodialysis, respectively, their impact on blood health is often highly deleterious and difficult to control. Further challenges are encountered when integrating multiple organ support functions, as is often required when ECMO and ultrafiltration (UF) are combined to deal with fluid overload in critically ill patients, necessitating an unwieldy circuit containing two separate cartridges. METHODS: We report the first laboratory demonstration of simultaneous blood gas oxygenation and fluid removal in single microfluidic circuit, an achievement enabled by the microchannel-based blood flow configuration of the device. Porcine blood is flowed through a stack of two microfluidic layers, one with a non-porous, gas-permeable silicone membrane separating blood and oxygen chambers, and the other containing a porous dialysis membrane separating blood and filtrate compartments. RESULTS: High levels of oxygen transfer are measured across the oxygenator, while tunable rates of fluid removal, governed by the transmembrane pressure (TMP), are achieved across the UF layer. Key parameters including the blood flow rate, TMP and hematocrit are monitored and compared with computationally predicted performance metrics. CONCLUSIONS: These results represent a model demonstration of a potential future clinical therapy where respiratory support and fluid removal are both realized through a single monolithic cartridge.


Assuntos
Oxigenação por Membrana Extracorpórea , Microfluídica , Humanos , Oxigenação por Membrana Extracorpórea/métodos , Oxigênio , Hemodinâmica/fisiologia , Silicones
2.
Hum Reprod ; 35(9): 2086-2096, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32756960

RESUMO

STUDY QUESTION: How does exposure to a testosterone rich environment affect the function and gene expression of human fallopian tube epithelium (hFTE)? SUMMARY ANSWER: Elevated testosterone level alters several gene transcripts that regulate cilia expression and negatively impacts the rate of cilia beating. WHAT IS KNOWN ALREADY: The presence of estrogen in the follicular phase of the menstrual cycle increases the human fallopian tube ciliary beating frequency. The luteal phase, triggered by ovulation and increasing progesterone, is marked by a decrease in ciliary beating. Women with polycystic ovarian syndrome (PCOS) may have twice the serum level of testosterone than ovulatory women. To date, the effect of elevated androgens on the function of the human fallopian tube is not well-understood. We chose to examine the impact of elevated testosterone on hFTE. STUDY DESIGN, SIZE, DURATION: A prospective basic science study of human fallopian tube specimens from reproductive-aged women undergoing benign gynecologic surgery was performed. Fallopian tube removal at a large US academic center was collected and provided to us to continue with epithelium isolation and culturing. A total of 12 patients were analyzed in the study. PARTICIPANTS/MATERIALS, SETTING, METHODS: Fallopian tube epithelium was isolated and exposed to two different conditions: normal with low testosterone concentration of 0.8 nM and PCOS-like, with high testosterone concentration of 2 nM. The study was conducted in both static and dynamic conditions in microfluidic devices for a total of 14 days, after which the tissue was collected for processing including RNA extraction, quantitative PCR and immunohistochemistry. After the first 7 days of each experiment, a sample of tissue from each condition was imaged to quantify cilia beating frequency. MAIN RESULTS AND THE ROLE OF CHANCE: hFTE exposed to the 2 nM testosterone displayed slower cilia beating, inhibited estrogen signaling and decreased expression of the ciliary marker FOXJ1 when compared to stimulation with 0.8 nM testosterone. LARGE SCALE DATA: N/A. LIMITATIONS, REASONS FOR CAUTION: The in vivo response to elevated testosterone may differ from in vitro studies. RNA amount was limited from tissue cultured in the microfluidic devices as compared to static culture. WIDER IMPLICATIONS OF THE FINDINGS: Understanding elevated testosterone in tubal function may explain an additional contribution to subfertility in women with PCOS and other hyper-androgen disorders, aside from oligo-ovulation. Furthermore, this adds to the body of literature of fallopian tube function using a microfluidic device. STUDY FUNDING/COMPETING INTEREST(S): NIH grants: UH3 ES029073 and R01 CA240301. There are no competing interests.


Assuntos
Tubas Uterinas , Síndrome do Ovário Policístico , Adulto , Cílios , Epitélio , Feminino , Expressão Gênica , Humanos , Estudos Prospectivos , Testosterona/farmacologia
3.
Proc Natl Acad Sci U S A ; 113(40): 11190-11195, 2016 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-27647912

RESUMO

Mechanical compliance has been demonstrated to be a key determinant of cell behavior, directing processes such as spreading, migration, and differentiation. Durotaxis, directional migration from softer to more stiff regions of a substrate, has been observed for a variety of cell types. Recent stiffness mapping experiments have shown that local changes in tissue stiffness in disease are often accompanied by an altered ECM composition in vivo. However, the importance of ECM composition in durotaxis has not yet been explored. To address this question, we have developed and characterized a polyacrylamide hydrogel culture platform featuring highly tunable gradients in mechanical stiffness. This feature, together with the ability to control ECM composition, allows us to isolate the effects of mechanical and biological signals on cell migratory behavior. Using this system, we have tracked vascular smooth muscle cell migration in vitro and quantitatively analyzed differences in cell migration as a function of ECM composition. Our results show that vascular smooth muscle cells undergo durotaxis on mechanical gradients coated with fibronectin but not on those coated with laminin. These findings indicate that the composition of the adhesion ligand is a critical determinant of a cell's migratory response to mechanical gradients.


Assuntos
Técnicas de Cultura de Células/métodos , Movimento Celular/genética , Matriz Extracelular/metabolismo , Estresse Mecânico , Resinas Acrílicas/química , Animais , Bovinos , Adesão Celular/genética , Diferenciação Celular/genética , Rastreamento de Células/métodos , Elasticidade , Matriz Extracelular/genética , Fibronectinas/química , Fibronectinas/metabolismo , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Laminina/química , Laminina/metabolismo , Ligantes , Músculo Liso Vascular/citologia , Músculo Liso Vascular/metabolismo , Transdução de Sinais
4.
Exp Cell Res ; 359(2): 361-366, 2017 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-28821395

RESUMO

Extracellular matrix composition and stiffness are known to be critical determinants of cell behavior, modulating processes including differentiation, traction generation, and migration. Recent studies have demonstrated that the ECM composition can modulate how cells migrate in response to gradients in environmental stiffness, altering a cell's ability to undergo durotaxis. These observations were limited to single varieties of extracellular matrix, but typically cells are exposed to environments containing complex mixtures of extracellular matrix proteins. Here, we investigate migration of NIH 3T3 fibroblasts on mechanical gradients coated with one or more type of extracellular matrix protein. Our results show that NIH 3T3 fibroblasts exhibit durotaxis on fibronectin-coated mechanical gradients but not on those coated with laminin, demonstrating that extracellular matrix type can act as a regulator of cell response to mechanical gradients. Interestingly, NIH 3T3 fibroblasts were also observed to migrate randomly on gradients coated with a mixture of both fibronectin and laminin, suggesting that there may be a complex interplay in the cellular response to mechanical gradients in the presence of multiple extracellular matrix signals. These findings indicate that specific composition of available adhesion ligands is a critical determinant of a cell's migratory response to mechanical gradients.


Assuntos
Matriz Extracelular/química , Fibronectinas/farmacologia , Laminina/farmacologia , Mecanotransdução Celular , Animais , Fenômenos Biomecânicos , Diferenciação Celular/efeitos dos fármacos , Movimento Celular/efeitos dos fármacos , Camundongos , Células NIH 3T3 , Estresse Mecânico
6.
ASAIO J ; 70(6): 535-544, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38165978

RESUMO

Microfluidic membrane oxygenators are designed to mimic branching vasculature of the native lung during extracorporeal lung support. To date, scaling of such devices to achieve clinically relevant blood flow and lung support has been a limitation. We evaluated a novel multilayer microfluidic blood oxygenator (BLOx) capable of supporting 750-800 ml/min blood flow versus a standard hollow fiber membrane oxygenator (HFMO) in vivo during veno-venous extracorporeal life support for 24 hours in anesthetized, mechanically ventilated uninjured swine (n = 3/group). The objective was to assess feasibility, safety, and biocompatibility. Circuits remained patent and operated with stable pressures throughout 24 hours. No group differences in vital signs or evidence of end-organ damage occurred. No change in plasma free hemoglobin and von Willebrand factor multimer size distribution were observed. Platelet count decreased in BLOx at 6 hours (37% dec, P = 0.03), but not in HFMO; however, thrombin generation potential was elevated in HFMO (596 ± 81 nM·min) versus BLOx (323 ± 39 nM·min) at 24 hours ( P = 0.04). Other coagulation and inflammatory mediator results were unremarkable. BLOx required higher mechanical ventilator settings and showed lower gas transfer efficiency versus HFMO, but the stable device performance indicates that this technology is ready for further performance scaling and testing in lung injury models and during longer use conditions.


Assuntos
Estudos de Viabilidade , Oxigenadores de Membrana , Animais , Suínos , Oxigenação por Membrana Extracorpórea/instrumentação , Oxigenação por Membrana Extracorpórea/métodos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Unidades de Terapia Intensiva , Microfluídica/métodos , Microfluídica/instrumentação
7.
Cancers (Basel) ; 15(7)2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-37046723

RESUMO

Fallopian tube epithelium (FTE) plays a critical role in reproduction and can be the site where High Grade Serous Ovarian Carcinoma (HGSOC) originates. Tumorigenic oviductal cells, which are the murine equivalent of human fallopian tube secretory epithelial cells (FTSEC), enhance testosterone secretion by the ovary when co-cultured with the ovary, suggesting that testosterone is part of the signaling axis between the ovary and FTSEC. Furthermore, testosterone promotes proliferation of oviductal cells. Oral contraceptives, tubal ligation, and salpingectomy, which are all protective against developing ovarian cancer, also decrease circulating levels of androgen. In the current study, we investigated the effect of increased testosterone on FTE and found that testosterone upregulates wingless-type MMTV integration family, member 4 (WNT4) and induces migration and invasion of immortalized human fallopian tube cells. We profiled primary human fallopian tissues grown in the microfluidic system SOLO-microfluidic platform -(MFP) by RNA sequencing and found that p53 and its downstream target genes, such as paired box gene 2 (PAX2), cyclin-dependent kinase inhibitor 1A (CDK1A or p21), and cluster of differentiation 82 (CD82 or KAI1) were downregulated in response to testosterone treatment. A microfluidic platform, the PREDICT-Multi Organ System (PREDICT-MOS) was engineered to support insert technology that allowed for the study of cancer cell migration and invasion through Matrigel. Using this system, we found that testosterone enhanced FTE migration and invasion, which was reversed by the androgen receptor (AR) antagonist, bicalutamide. Testosterone also enhanced FTSEC adhesion to the ovarian stroma using murine ovaries. Overall, these results indicate that primary human fallopian tube tissue and immortalized FTSEC respond to testosterone to shift expression of genes that regulate invasion, while leveraging a new strategy to study migration in the presence of dynamic fluid flow.

8.
Commun Biol ; 6(1): 92, 2023 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-36690695

RESUMO

Nearly half of American adults suffer from gum disease, including mild inflammation of gingival tissue, known as gingivitis. Currently, advances in therapeutic treatments are hampered by a lack of mechanistic understanding of disease progression in physiologically relevant vascularized tissues. To address this, we present a high-throughput microfluidic organ-on-chip model of human gingival tissue containing keratinocytes, fibroblast and endothelial cells. We show the triculture model exhibits physiological tissue structure, mucosal barrier formation, and protein biomarker expression and secretion over several weeks. Through inflammatory cytokine administration, we demonstrate the induction of inflammation measured by changes in barrier function and cytokine secretion. These states of inflammation are induced at various time points within a stable culture window, providing a robust platform for evaluation of therapeutic agents. These data reveal that the administration of specific small molecule inhibitors mitigates the inflammatory response and enables tissue recovery, providing an opportunity for identification of new therapeutic targets for gum disease with the potential to facilitate relevant preclinical drug efficacy and toxicity testing.


Assuntos
Gengivite , Microfluídica , Adulto , Humanos , Células Endoteliais , Citocinas , Inflamação
9.
Adv Sci (Weinh) ; 10(18): e2207455, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37092588

RESUMO

Recent global events such as COVID-19 pandemic amid rising rates of chronic lung diseases highlight the need for safer, simpler, and more available treatments for respiratory failure, with increasing interest in extracorporeal membrane oxygenation (ECMO). A key factor limiting use of this technology is the complexity of the blood circuit, resulting in clotting and bleeding and necessitating treatment in specialized care centers. Microfluidic oxygenators represent a promising potential solution, but have not reached the scale or performance required for comparison with conventional hollow fiber membrane oxygenators (HFMOs). Here the development and demonstration of the first microfluidic respiratory assist device at a clinical scale is reported, demonstrating efficient oxygen transfer at blood flow rates of 750 mL min⁻1 , the highest ever reported for a microfluidic device. The central innovation of this technology is a fully 3D branching network of blood channels mimicking key features of the physiological microcirculation by avoiding anomalous blood flows that lead to thrombus formation and blood damage in conventional oxygenators. Low, stable blood pressure drop, low hemolysis, and consistent oxygen transfer, in 24-hour pilot large animal experiments are demonstrated - a key step toward translation of this technology to the clinic for treatment of a range of lung diseases.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Animais , Humanos , Microfluídica , Pandemias , Oxigênio
10.
Bioengineering (Basel) ; 10(4)2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37106610

RESUMO

The human fallopian tube epithelium (hFTE) is the site of fertilization, early embryo development, and the origin of most high-grade serous ovarian cancers (HGSOCs). Little is known about the content and functions of hFTE-derived small extracellular vesicles (sEVs) due to the limitations of biomaterials and proper culture methods. We have established a microfluidic platform to culture hFTE for EV collection with adequate yield for mass spectrometry-based proteomic profiling, and reported 295 common hFTE sEV proteins for the first time. These proteins are associated with exocytosis, neutrophil degranulation, and wound healing, and some are crucial for fertilization processes. In addition, by correlating sEV protein profiles with hFTE tissue transcripts characterized using GeoMx® Cancer Transcriptome Atlas, spatial transcriptomics analysis revealed cell-type-specific transcripts of hFTE that encode sEVs proteins, among which, FLNA, TUBB, JUP, and FLNC were differentially expressed in secretory cells, the precursor cells for HGSOC. Our study provides insights into the establishment of the baseline proteomic profile of sEVs derived from hFTE tissue, and its correlation with hFTE lineage-specific transcripts, which can be used to evaluate whether the fallopian tube shifts its sEV cargo during ovarian cancer carcinogenesis and the role of sEV proteins in fallopian tube reproductive functions.

11.
Front Mol Biosci ; 10: 1160851, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37577751

RESUMO

Background: Tissue fibrosis is a major healthcare burden that affects various organs in the body for which no effective treatments exist. An underlying, emerging theme across organs and tissue types at early stages of fibrosis is the activation of pericytes and/or fibroblasts in the perivascular space. In hepatic tissue, it is well known that liver sinusoidal endothelial cells (EC) help maintain the quiescence of stellate cells, but whether this phenomenon holds true for other endothelial and perivascular cell types is not well studied. Methods: The goal of this work was to develop an organ-on-chip microvascular model to study the effect of EC co-culture on the activation of perivascular cells perturbed by the pro-fibrotic factor TGFß1. A high-throughput microfluidic platform, PREDICT96, that was capable of imparting physiologically relevant fluid shear stress on the cultured endothelium was utilized. Results: We first studied the activation response of several perivascular cell types and selected a cell source, human dermal fibroblasts, that exhibited medium-level activation in response to TGFß1. We also demonstrated that the PREDICT96 high flow pump triggered changes in select shear-responsive factors in human EC. We then found that the activation response of fibroblasts was significantly blunted in co-culture with EC compared to fibroblast mono-cultures. Subsequent studies with conditioned media demonstrated that EC-secreted factors play at least a partial role in suppressing the activation response. A Luminex panel and single cell RNA-sequencing study provided additional insight into potential EC-derived factors that could influence fibroblast activation. Conclusion: Overall, our findings showed that EC can reduce myofibroblast activation of perivascular cells in response to TGFß1. Further exploration of EC-derived factors as potential therapeutic targets in fibrosis is warranted.

12.
Front Cardiovasc Med ; 9: 884116, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36093160

RESUMO

Characterization of cardiovascular tissue geometry and mechanical properties of large animal models is essential when developing cardiovascular devices such as heart valve replacements. These datasets are especially critical when designing devices for pediatric patient populations, as there is often limited data for guidance. Here, we present a previously unavailable dataset capturing anatomical measurements and mechanical properties of juvenile Yorkshire (YO) and Yucatan (YU) porcine main pulmonary artery (PA) and pulmonary valve (PV) tissue regions that will inform pediatric heart valve design requirements for preclinical animal studies. In addition, we developed a novel radial balloon catheter-based method to measure tissue stiffness and validated it against a traditional uniaxial tensile testing method. YU piglets, which were significantly lower weight than YO counterparts despite similar age, had smaller PA and PV diameters (7.6-9.9 mm vs. 10.1-12.8 mm). Young's modulus (stiffness) was measured for the PA and the PV region using both the radial and uniaxial testing methods. There was no significant difference between the two breeds for Young's modulus measured in the elastic (YU PA 84.7 ± 37.3 kPa, YO PA 79.3 ± 15.7 kPa) and fibrous regimes (YU PA 308.6 ± 59.4 kPa, YO PA 355.7 ± 68.9 kPa) of the stress-strain curves. The two testing techniques also produced similar stiffness measurements for the PA and PV region, although PV data showed greater variation between techniques. Overall, YU and YO piglets had similar PA and PV diameters and tissue stiffness to previously reported infant pediatric patients. These results provide a previously unavailable age-specific juvenile porcine tissue geometry and stiffness dataset critical to the development of pediatric cardiovascular prostheses. Additionally, the data demonstrates the efficacy of a novel balloon catheter-based technique that could be adapted to non-destructively measure tissue stiffness in situ.

13.
Microsyst Nanoeng ; 8: 109, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36187891

RESUMO

Measurement of cell metabolism in moderate-throughput to high-throughput organ-on-chip (OOC) systems would expand the range of data collected for studying drug effects or disease in physiologically relevant tissue models. However, current measurement approaches rely on fluorescent imaging or colorimetric assays that are focused on endpoints, require labels or added substrates, and lack real-time data. Here, we integrated optical-based oxygen sensors in a high-throughput OOC platform and developed an approach for monitoring cell metabolic activity in an array of membrane bilayer devices. Each membrane bilayer device supported a culture of human renal proximal tubule epithelial cells on a porous membrane suspended between two microchannels and exposed to controlled, unidirectional perfusion and physiologically relevant shear stress for several days. For the first time, we measured changes in oxygen in a membrane bilayer format and used a finite element analysis model to estimate cell oxygen consumption rates (OCRs), allowing comparison with OCRs from other cell culture systems. Finally, we demonstrated label-free detection of metabolic shifts in human renal proximal tubule cells following exposure to FCCP, a drug known for increasing cell oxygen consumption, as well as oligomycin and antimycin A, drugs known for decreasing cell oxygen consumption. The capability to measure cell OCRs and detect metabolic shifts in an array of membrane bilayer devices contained within an industry standard microtiter plate format will be valuable for analyzing flow-responsive and physiologically complex tissues during drug development and disease research.

14.
Cancer Lett ; 543: 215779, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35697329

RESUMO

High grade serous ovarian cancers (HGSOC) predominantly arise in the fallopian tube epithelium (FTE) and colonize the ovary first, before further metastasis to the peritoneum. Ovarian cancer risk is directly related to the number of ovulations, suggesting that the ovary may secrete specific factors that act as chemoattractants for fallopian tube derived tumor cells during ovulation. We found that 3D ovarian organ culture produced a secreted factor that enhanced the migration of FTE non-tumorigenic cells as well as cells harboring specific pathway modifications commonly found in high grade serous cancers. Through size fractionation and a small molecule inhibitors screen, the secreted protein was determined to be 50-100kDa in size and acted through the Epidermal Growth Factor Receptor (EGFR). To correlate the candidates with ovulation, the PREDICT organ-on-chip system was optimized to support ovulation in a perfused microfluidic platform. Versican was found in the correct molecular weight range, contained EGF-like domains, and correlated with ovulation in the PREDICT system. Exogenous versican increased migration, invasion, and enhanced adhesion of both murine and human FTE cells to the ovary in an EGFR-dependent manner. The identification of a protein secreted during ovulation that impacts the ability of FTE cells to colonize the ovary provides new insights into the development of strategies for limiting primary ovarian metastasis.


Assuntos
Cistadenocarcinoma Seroso , Neoplasias das Tubas Uterinas , Neoplasias Ovarianas , Animais , Cistadenocarcinoma Seroso/patologia , Receptores ErbB , Neoplasias das Tubas Uterinas/patologia , Tubas Uterinas/patologia , Feminino , Humanos , Camundongos , Neoplasias Ovarianas/patologia , Ovulação , Versicanas/genética
15.
ASAIO J ; 68(10): 1312-1319, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-36194101

RESUMO

Extracorporeal membrane oxygenation (ECMO) has been advancing rapidly due to a combination of rising rates of acute and chronic lung diseases as well as significant improvements in the safety and efficacy of this therapeutic modality. However, the complexity of the ECMO blood circuit, and challenges with regard to clotting and bleeding, remain as barriers to further expansion of the technology. Recent advances in microfluidic fabrication techniques, devices, and systems present an opportunity to develop new solutions stemming from the ability to precisely maintain critical dimensions such as gas transfer membrane thickness and blood channel geometries, and to control levels of fluid shear within narrow ranges throughout the cartridge. Here, we present a physiologically inspired multilayer microfluidic oxygenator device that mimics physiologic blood flow patterns not only within individual layers but throughout a stacked device. Multiple layers of this microchannel device are integrated with a three-dimensional physiologically inspired distribution manifold that ensures smooth flow throughout the entire stacked device, including the critical entry and exit regions. We then demonstrate blood flows up to 200 ml/min in a multilayer device, with oxygen transfer rates capable of saturating venous blood, the highest of any microfluidic oxygenator, and a maximum blood flow rate of 480 ml/min in an eight-layer device, higher than any yet reported in a microfluidic device. Hemocompatibility and large animal studies utilizing these prototype devices are planned. Supplemental Visual Abstract, http://links.lww.com/ASAIO/A769.


Assuntos
Biomimética , Microfluídica , Animais , Desenho de Equipamento , Oxigênio , Oxigenadores
16.
Biophys J ; 101(3): 622-30, 2011 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-21806930

RESUMO

The vessel wall experiences progressive stiffening with age and the development of cardiovascular disease, which alters the micromechanical environment experienced by resident vascular smooth muscle cells (VSMCs). In vitro studies have shown that VSMCs are sensitive to substrate stiffness, but the exact molecular mechanisms of their response to stiffness remains unknown. Studies have also shown that cell-cell interactions can affect mechanotransduction at the cell-substrate interface. Using flexible substrates, we show that the expression of proteins associated with cell-matrix adhesion and cytoskeletal tension is regulated by substrate stiffness, and that an increase in cell density selectively attenuates some of these effects. We also show that cell-cell interactions exert a strong effect on cell morphology in a substrate-stiffness dependent manner. Collectively, the data suggest that as VSMCs form cell-cell contacts, substrate stiffness becomes a less potent regulator of focal adhesion signaling. This study provides insight into the mechanisms by which VSMCs respond to the mechanical environment of the blood vessel wall, and point to cell-cell interactions as critical mediators of VSMC response to vascular injury.


Assuntos
Comunicação Celular , Fenômenos Mecânicos , Músculo Liso Vascular/citologia , Músculo Liso Vascular/metabolismo , Animais , Fenômenos Biomecânicos , Contagem de Células , Forma Celular , Citoesqueleto/metabolismo , Matriz Extracelular/metabolismo , Adesões Focais/metabolismo , Regulação da Expressão Gênica , Integrina alfa5beta1/genética , Transporte Proteico , Ratos , Vinculina/metabolismo
17.
Front Cell Infect Microbiol ; 11: 691210, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34123879

RESUMO

Urinary tract infections (UTIs) are among the most common infectious diseases worldwide but are significantly understudied. Uropathogenic E. coli (UPEC) accounts for a significant proportion of UTI, but a large number of other species can infect the urinary tract, each of which will have unique host-pathogen interactions with the bladder environment. Given the substantial economic burden of UTI and its increasing antibiotic resistance, there is an urgent need to better understand UTI pathophysiology - especially its tendency to relapse and recur. Most models developed to date use murine infection; few human-relevant models exist. Of these, the majority of in vitro UTI models have utilized cells in static culture, but UTI needs to be studied in the context of the unique aspects of the bladder's biophysical environment (e.g., tissue architecture, urine, fluid flow, and stretch). In this review, we summarize the complexities of recurrent UTI, critically assess current infection models and discuss potential improvements. More advanced human cell-based in vitro models have the potential to enable a better understanding of the etiology of UTI disease and to provide a complementary platform alongside animals for drug screening and the search for better treatments.


Assuntos
Infecções por Escherichia coli , Infecções Urinárias , Sistema Urinário , Escherichia coli Uropatogênica , Animais , Humanos , Camundongos , Bexiga Urinária
18.
Sci Rep ; 11(1): 12225, 2021 06 09.
Artigo em Inglês | MEDLINE | ID: mdl-34108507

RESUMO

Microphysiological organ-on-chip models offer the potential to improve the prediction of drug safety and efficacy through recapitulation of human physiological responses. The importance of including multiple cell types within tissue models has been well documented. However, the study of cell interactions in vitro can be limited by complexity of the tissue model and throughput of current culture systems. Here, we describe the development of a co-culture microvascular model and relevant assays in a high-throughput thermoplastic organ-on-chip platform, PREDICT96. The system consists of 96 arrayed bilayer microfluidic devices containing retinal microvascular endothelial cells and pericytes cultured on opposing sides of a microporous membrane. Compatibility of the PREDICT96 platform with a variety of quantifiable and scalable assays, including macromolecular permeability, image-based screening, Luminex, and qPCR, is demonstrated. In addition, the bilayer design of the devices allows for channel- or cell type-specific readouts, such as cytokine profiles and gene expression. The microvascular model was responsive to perturbations including barrier disruption, inflammatory stimulation, and fluid shear stress, and our results corroborated the improved robustness of co-culture over endothelial mono-cultures. We anticipate the PREDICT96 platform and adapted assays will be suitable for other complex tissues, including applications to disease models and drug discovery.


Assuntos
Comunicação Celular , Técnicas de Cocultura/métodos , Derme/metabolismo , Endotélio Vascular/metabolismo , Técnicas Analíticas Microfluídicas/métodos , Pericitos/metabolismo , Retina/metabolismo , Permeabilidade da Membrana Celular , Células Cultivadas , Derme/citologia , Endotélio Vascular/citologia , Humanos , Pericitos/citologia , Retina/citologia
19.
Micromachines (Basel) ; 12(8)2021 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-34442512

RESUMO

The recent emergence of microfluidic extracorporeal lung support technologies presents an opportunity to achieve high gas transfer efficiency and improved hemocompatibility relative to the current standard of care in extracorporeal membrane oxygenation (ECMO). However, a critical challenge in the field is the ability to scale these devices to clinically relevant blood flow rates, in part because the typically very low blood flow in a single layer of a microfluidic oxygenator device requires stacking of a logistically challenging number of layers. We have developed biomimetic microfluidic oxygenators for the past decade and report here on the development of a high-flow (30 mL/min) single-layer prototype, scalable to larger structures via stacking and assembly with blood distribution manifolds. Microfluidic oxygenators were designed with biomimetic in-layer blood distribution manifolds and arrays of parallel transfer channels, and were fabricated using high precision machined durable metal master molds and microreplication with silicone films, resulting in large area gas transfer devices. Oxygen transfer was evaluated by flowing 100% O2 at 100 mL/min and blood at 0-30 mL/min while monitoring increases in O2 partial pressures in the blood. This design resulted in an oxygen saturation increase from 65% to 95% at 20 mL/min and operation up to 30 mL/min in multiple devices, the highest value yet recorded in a single layer microfluidic device. In addition to evaluation of the device for blood oxygenation, a 6-h in vitro hemocompatibility test was conducted on devices (n = 5) at a 25 mL/min blood flow rate with heparinized swine donor blood against control circuits (n = 3). Initial hemocompatibility results indicate that this technology has the potential to benefit future applications in extracorporeal lung support technologies for acute lung injury.

20.
Lab Chip ; 20(19): 3653, 2020 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-32756648

RESUMO

Correction for 'A high-throughput microfluidic microphysiological system (PREDICT-96) to recapitulate hepatocyte function in dynamic, re-circulating flow conditions' by Kelly Tan et al., Lab Chip, 2019, 19, 1556-1566, DOI: .

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa