Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Surg Oncol ; 119(4): 409-420, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30589080

RESUMO

BACKGROUND: A prospective randomized controlled trial has established the efficacy of targeted intraoperative radiotherapy (TARGIT) in the management of invasive breast cancer treated with breast-conserving surgery (BCS). The purpose of this analysis is to evaluate the efficacy of TARGIT in the management of ductal carcinoma in situ (DCIS). METHODS: A prospective nonrandomized trial was designed to evaluate the success of TARGIT in the management of DCIS, as measured by a low risk of requiring additional surgery or radiotherapy and an acceptable local recurrence rate (LRR). RESULTS: Fifty-five patients with DCIS received BCS and TARGIT from November 2007 to March 2017. Median patient age was 57 years (range, 42-83 years) and median histological lesion size was 14.4 mm (range, 2-51 mm). Four patients required either re-excision and/or whole breast irradiation, yielding a rate of additional therapy of 7.3% (4 of 55). Among 46 women administered TARGIT at the time of initial BCS, two local recurrences were observed yielding a 4.3% (2 of 46) LRR at 46 months median follow-up (range, 4-116 months). There were no clinically significant adverse events. CONCLUSIONS: Preliminary evidence indicates TARGIT can be performed with a low risk of requiring additional therapy (7.3%) and an acceptable LRR (4.3%) when administered at the time of BCS.


Assuntos
Neoplasias da Mama/terapia , Carcinoma Intraductal não Infiltrante/terapia , Mastectomia Segmentar/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Mama/efeitos da radiação , Terapia Combinada , Feminino , Humanos , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/terapia , Estudos Prospectivos
2.
Breast J ; 22(1): 63-74, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26534876

RESUMO

Multiple long-term studies have demonstrated a propensity for breast cancer recurrences to develop near the site of the original breast cancer. Recognition of this local recurrence pattern laid the foundation for the development of accelerated partial breast irradiation (APBI) approaches designed to limit the radiation treatment field to the site of the malignancy. However, there is a paucity of data regarding the efficacy of APBI in general, and intraoperative radiotherapy (IORT), in particular, for the management of ductal carcinoma in situ (DCIS). As a result, use of APBI, remains controversial. A prospective nonrandomized trial was designed to determine if patients with pure DCIS considered eligible for concurrent IORT based on preoperative mammography and contrast-enhanced magnetic resonance imaging (CE-MRI) could be successfully treated using IORT with minimal need for additional therapy due to inadequate surgical margins or excessive tumor size. Between November 2007 and June 2014, 35 women underwent bilateral digital mammography and bilateral breast CE-MRI prior to selection for IORT. Patients were deemed eligible for IORT if their lesion was ≤4 cm in maximal diameter on both digital mammography and CE-MRI, pure DCIS on minimally invasive breast biopsy or wide local excision, and considered resectable with clear surgical margins using breast-conserving surgery (BCS). Postoperatively, the DCIS lesion size determined by imaging was compared with lesion size and surgical margin status obtained from the surgical pathology specimen. Thirty-five patients completed IORT. Median patient age was 57 years (range 42-79 years) and median histologic lesion size was 15.6 mm (2-40 mm). No invasive cancer was identified. In more than half of the patients in our study (57.1%), MRI failed to detect a corresponding lesion. Nonetheless, 30 patients met criteria for negative margins (i.e., margins ≥2 mm) whereas five patients had positive margins (<2 mm). Two of the five patients with positive margins underwent mastectomy due to extensive imaging-occult DCIS. Three of the five patients with positive margins underwent successful re-excision at a subsequent operation prior to subsequent whole breast irradiation. A total of 14.3% (5/35) of patients required some form of additional therapy. At 36 months median follow-up (range of 2-83 months, average 42 months), only two patients experienced local recurrences of cancer (DCIS only), yielding a 5.7% local recurrence rate. No deaths or distant recurrences were observed. Imaging-occult DCIS is a challenge for IORT, as it is for all forms of breast-conserving therapy. Nonetheless, 91.4% of patients with DCIS were successfully managed with BCS and IORT alone, with relatively few patients requiring additional therapy.


Assuntos
Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Carcinoma Intraductal não Infiltrante/radioterapia , Carcinoma Intraductal não Infiltrante/cirurgia , Adulto , Idoso , Neoplasias da Mama/patologia , Carcinoma Intraductal não Infiltrante/patologia , Meios de Contraste , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Mamografia , Mastectomia/métodos , Mastectomia Segmentar/métodos , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
3.
Life (Basel) ; 13(8)2023 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-37629613

RESUMO

Breast cancer cryoablation has emerged as a minimally invasive alternative to lumpectomy for treating early-stage breast cancer. However, no consensus exists on what should be considered the standard of care for the multidisciplinary management of patients treated with breast cancer cryoablation. In lieu of national guidelines, this review of the literature provides a multidisciplinary framework and an evidence-based discussion of the integration of "standard of care practices" in the comprehensive management of breast cancer cryoablation patients.

4.
Anticancer Res ; 43(6): 2383-2391, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37247916

RESUMO

Women with HR+HER2+ early-stage breast cancer are disadvantaged by the lack of clinical trials focused on women ≥70 years of age. In the past years, there has been increasing controversy on the use of toxic chemotherapy as standard of care treatment for early- stage HR+ HER2+ breast carcinoma in older women. With precision medicine coming of age, molecular profiling of tumors and circulating tumor DNA has identified target oncogenes that could be used in designing an optimal treatment for this group of women. This article reviews the current treatment of early-stage triple receptor positive breast cancer, the risks of chemotherapy in older women, and CCNG1, a novel biomarker in development for the use of DeltaRex-G, a CCNG1 inhibitor. Further, future perspectives for DeltaRex-G in older women with early stage CCNG1+ HR+ HER2+ breast cancer are discussed.


Assuntos
Neoplasias da Mama , Receptor ErbB-2 , Feminino , Humanos , Idoso , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Trastuzumab , Ciclina G1
5.
AJR Am J Roentgenol ; 193(2): 574-81, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19620458

RESUMO

OBJECTIVE: Granulomatous lobular mastitis is a rare chronic inflammatory disease that has clinical and radiologic findings similar to those of breast cancer. We performed a retrospective analysis of clinical, imaging, and treatment findings in 54 women diagnosed with granulomatous lobular mastitis between January 2000 and April 2008. CONCLUSION: The imaging findings of granulomatous lobular mastitis overlap with those of malignancy. The most common presentation is a focal asymmetric density on mammography and an irregular hypoechoic mass with tubular extensions on ultrasound. Core biopsy is typically diagnostic. Once the diagnosis is established by tissue sampling, corticosteroids are the first line of treatment.


Assuntos
Granuloma/diagnóstico , Granuloma/terapia , Mastite/diagnóstico , Mastite/terapia , Adulto , Biópsia por Agulha Fina , Feminino , Granuloma/complicações , Humanos , Estudos Retrospectivos
6.
Breast Cancer Res ; 10(4): R72, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18724867

RESUMO

INTRODUCTION: The purpose of the present study was to investigate the effect of computer-aided detection (CAD) prompts on reader behaviour in a large sample of breast screening mammograms by analysing the relationship of the presence and size of prompts to the recall decision. METHODS: Local research ethics committee approval was obtained; informed consent was not required. Mammograms were obtained from women attending routine mammography at two breast screening centres in 1996. Films, previously double read, were re-read by a different reader using CAD. The study material included 315 cancer cases comprising all screen-detected cancer cases, all subsequent interval cancers and 861 normal cases randomly selected from 10,267 cases. Ground truth data were used to assess the efficacy of CAD prompting. Associations between prompt attributes and tumour features or reader recall decisions were assessed by chi-squared tests. RESULTS: There was a highly significant relationship between prompting and a decision to recall for cancer cases and for a random sample of normal cases (P < 0.001). Sixty-four per cent of all cases contained at least one CAD prompt. In cancer cases, larger prompts were more likely to be recalled (P = 0.02) for masses but there was no such association for calcifications (P = 0.9). In a random sample of 861 normal cases, larger prompts were more likely to be recalled (P = 0.02) for both mass and calcification prompts. Significant associations were observed with prompting and breast density (p = 0.009) for cancer cases but not for normal cases (P = 0.05). CONCLUSIONS: For both normal cases and cancer cases, prompted mammograms were more likely to be recalled and the prompt size was also associated with a recall decision.


Assuntos
Neoplasias da Mama/diagnóstico , Diagnóstico por Computador/métodos , Mamografia/métodos , Idoso , Neoplasias da Mama/patologia , Computadores , Detecção Precoce de Câncer , Feminino , Humanos , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Projetos de Pesquisa , Resultado do Tratamento
7.
Breast Cancer Res ; 10(4): R64, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18651965

RESUMO

INTRODUCTION: Mammographic density is known to be a strong risk factor for breast cancer. A particularly strong association with risk has been observed when density is measured using interactive threshold software. This, however, is a labour-intensive process for large-scale studies. METHODS: Our aim was to determine the performance of visually assessed percent breast density as an indicator of breast cancer risk. We compared the effect on risk of density as measured with the mediolateral oblique view only versus that estimated as the average density from the mediolateral oblique view and the craniocaudal view. Density was assessed using a visual analogue scale in 10,048 screening mammograms, including 311 breast cancer cases diagnosed at that screening episode or within the following 6 years. RESULTS: Where only the mediolateral oblique view was available, there was a modest effect of breast density on risk with an odds ratio for the 76% to 100% density relative to 0% to 25% of 1.51 (95% confidence interval 0.71 to 3.18). When two views were available, there was a considerably stronger association, with the corresponding odds ratio being 6.77 (95% confidence interval 2.75 to 16.67). CONCLUSION: This indicates that a substantial amount of information on risk from percentage breast density is contained in the second view. It also suggests that visually assessed breast density has predictive potential for breast cancer risk comparable to that of density measured using the interactive threshold software when two views are available. This observation needs to be confirmed by studies applying the different measurement methods to the same individuals.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Mama/patologia , Mamografia/métodos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Programas de Rastreamento/métodos , Razão de Chances , Reprodutibilidade dos Testes , Risco , Medição de Risco/métodos , Fatores de Risco , Software
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa