Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 140
Filtrar
1.
Nat Rev Genet ; 23(1): 55-68, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34526697

RESUMO

Plant intra-individual and inter-individual variation can be determined by the epigenome, a set of covalent modifications of DNA and chromatin that can alter genome structure and activity without changes to the genome sequence. The epigenome of plant cells is plastic, that is, it can change in response to internal or external cues, such as during development or due to environmental changes, to create a memory of such events. Ongoing advances in technologies to read and write epigenomic patterns with increasing resolution, scale and precision are enabling the extent of plant epigenome variation to be more extensively characterized and functionally interrogated. In this Review, we discuss epigenome dynamics and variation within plants during development and in response to environmental changes, including stress, as well as between plants. We review known or potential functions of such plasticity and emphasize the importance of investigating the causality of epigenomic changes. Finally, we discuss emerging technologies that may underpin future research into plant epigenome plasticity.


Assuntos
Metilação de DNA , Epigênese Genética/genética , Epigenoma/genética , Epigenômica , Variação Genética , Plantas/genética , Regulação da Expressão Gênica de Plantas , Genes de Plantas/genética , Modelos Genéticos , Mutação , Proteínas de Plantas/genética , Plantas/classificação , Sítio de Iniciação de Transcrição
2.
Magn Reson Med ; 91(3): 955-971, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37984456

RESUMO

PURPOSE: Dynamic lung oxygen-enhanced MRI (OE-MRI) is challenging due to the presence of confounding signals and poor signal-to-noise ratio, particularly at 3 T. We have created a robust pipeline utilizing independent component analysis (ICA) to automatically extract the oxygen-induced signal change from confounding factors to improve the accuracy and sensitivity of lung OE-MRI. METHODS: Dynamic OE-MRI was performed on healthy participants using a dual-echo multi-slice spoiled gradient echo sequence at 3 T and cyclical gas delivery. ICA was applied to each echo within a thoracic mask. The ICA component relating to the oxygen-enhancement signal was automatically identified using correlation analysis. The oxygen-enhancement component was reconstructed, and the percentage signal enhancement (PSE) was calculated. The lung PSE of current smokers was compared with nonsmokers; scan-rescan repeatability, ICA pipeline repeatability, and reproducibility between two vendors were assessed. RESULTS: ICA successfully extracted a consistent oxygen-enhancement component for all participants. Lung tissue and oxygenated blood displayed the opposite oxygen-induced signal enhancements. A significant difference in PSE was observed between the lungs of current smokers and nonsmokers. The scan-rescan repeatability and the ICA pipeline repeatability were good. CONCLUSION: The developed pipeline demonstrated sensitivity to the signal enhancements of the lung tissue and oxygenated blood at 3 T. The difference in lung PSE between current smokers and nonsmokers indicates a likely sensitivity to lung function alterations that may be seen in mild pathology, supporting future use of our methods in patient studies.


Assuntos
Pulmão , Oxigênio , Humanos , Reprodutibilidade dos Testes , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
3.
Magn Reson Med ; 91(3): 972-986, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38013206

RESUMO

PURPOSE: To demonstrate proof-of-concept of a T2 *-sensitized oxygen-enhanced MRI (OE-MRI) method at 3T by assessing signal characteristics, repeatability, and reproducibility of dynamic lung OE-MRI metrics in healthy volunteers. METHODS: We performed sequence-specific simulations for protocol optimisation and acquired free-breathing OE-MRI data from 16 healthy subjects using a dual-echo RF-spoiled gradient echo approach at 3T across two institutions. Non-linear registration and tissue density correction were applied. Derived metrics included percent signal enhancement (PSE), ∆R2 * and wash-in time normalized for breathing rate (τ-nBR). Inter-scanner reproducibility and intra-scanner repeatability were evaluated using intra-class correlation coefficient (ICC), repeatability coefficient, reproducibility coefficient, and Bland-Altman analysis. RESULTS: Simulations and experimental data show negative contrast upon oxygen inhalation, due to substantial dominance of ∆R2 * at TE > 0.2 ms. Density correction improved signal fluctuations. Density-corrected mean PSE values, aligned with simulations, display TE-dependence, and an anterior-to-posterior PSE reduction trend at TE1 . ∆R2 * maps exhibit spatial heterogeneity in oxygen delivery, featuring anterior-to-posterior R2 * increase. Mean T2 * values across 32 scans were 0.68 and 0.62 ms for pre- and post-O2 inhalation, respectively. Excellent or good agreement emerged from all intra-, inter-scanner and inter-rater variability tests for PSE and ∆R2 *. However, ICC values for τ-nBR demonstrated limited agreement between repeated measures. CONCLUSION: Our results demonstrate the feasibility of a T2 *-weighted method utilizing a dual-echo RF-spoiled gradient echo approach, simultaneously capturing PSE, ∆R2 * changes, and oxygen wash-in during free-breathing. The excellent or good repeatability and reproducibility on intra- and inter-scanner PSE and ∆R2 * suggest potential utility in multi-center clinical applications.


Assuntos
Imageamento por Ressonância Magnética , Oxigênio , Humanos , Reprodutibilidade dos Testes , Estudos de Viabilidade , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem
4.
Magn Reson Med ; 91(5): 1803-1821, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38115695

RESUMO

PURPOSE: K trans $$ {K}^{\mathrm{trans}} $$ has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for K trans $$ {K}^{\mathrm{trans}} $$ quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging-Dynamic Contrast-Enhanced (OSIPI-DCE) challenge was designed to benchmark methods to better help the efforts to standardize K trans $$ {K}^{\mathrm{trans}} $$ measurement. METHODS: A framework was created to evaluate K trans $$ {K}^{\mathrm{trans}} $$ values produced by DCE-MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for K trans $$ {K}^{\mathrm{trans}} $$ quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' K trans $$ {K}^{\mathrm{trans}} $$ values, the applied software, and a standard operating procedure. These were evaluated using the proposed OSIP I gold $$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score defined with accuracy, repeatability, and reproducibility components. RESULTS: Across the 10 received submissions, the OSIP I gold $$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0-1 = lowest-highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in K trans $$ {K}^{\mathrm{trans}} $$ analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility. CONCLUSIONS: This study reports results from the OSIPI-DCE challenge and highlights the high inter-software variability within K trans $$ {K}^{\mathrm{trans}} $$ estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real-world clinical setting, many of these tools may perform differently with different benchmarking methodology.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética , Humanos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Software , Algoritmos
5.
Magn Reson Med ; 90(3): 1130-1136, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37222226

RESUMO

The British and Irish Chapter of the International Society for Magnetic Resonance in Medicine (BIC-ISMRM) held a workshop entitled "Steps on the path to clinical translation" in Cardiff, UK, on 7th September 2022. The aim of the workshop was to promote discussion within the MR community about the problems and potential solutions for translating quantitative MR (qMR) imaging and spectroscopic biomarkers into clinical application and drug studies. Invited speakers presented the perspectives of radiologists, radiographers, clinical physicists, vendors, imaging Contract/Clinical Research Organizations (CROs), open science networks, metrologists, imaging networks, and those developing consensus methods. A round-table discussion was held in which workshop participants discussed a range of questions pertinent to clinical translation of qMR imaging and spectroscopic biomarkers. Each group summarized their findings via three main conclusions and three further questions. These questions were used as the basis of an online survey of the broader UK MR community.


Assuntos
Imageamento por Ressonância Magnética , Humanos , Espectroscopia de Ressonância Magnética , Biomarcadores
6.
Magn Reson Med ; 86(4): 1829-1844, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33973674

RESUMO

PURPOSE: We introduce a novel, generalized tracer kinetic model selection framework to quantify microvascular characteristics of liver and tumor tissue in gadoxetate-enhanced dynamic contrast-enhanced MRI (DCE-MRI). METHODS: Our framework includes a hierarchy of nested models, from which physiological parameters are derived in 2 regimes, corresponding to the active transport and free diffusion of gadoxetate. We use simulations to show the sensitivity of model selection and parameter estimation to temporal resolution, time-series duration, and noise. We apply the framework in 8 healthy volunteers (time-series duration up to 24 minutes) and 10 patients with hepatocellular carcinoma (6 minutes). RESULTS: The active transport regime is preferred in 98.6% of voxels in volunteers, 82.1% of patients' non-tumorous liver, and 32.2% of tumor voxels. Interpatient variations correspond to known co-morbidities. Simulations suggest both datasets have sufficient temporal resolution and signal-to-noise ratio, while patient data would be improved by using a time-series duration of at least 12 minutes. CONCLUSIONS: In patient data, gadoxetate exhibits different kinetics: (a) between liver and tumor regions and (b) within regions due to liver disease and/or tumor heterogeneity. Our generalized framework selects a physiological interpretation at each voxel, without preselecting a model for each region or duplicating time-consuming optimizations for models with identical functional forms.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Gadolínio DTPA , Humanos , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética
7.
BMC Cancer ; 21(1): 354, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33794823

RESUMO

BACKGROUND: Patients with metastatic colorectal cancer are treated with cytotoxic chemotherapy supplemented by molecularly targeted therapies. There is a critical need to define biomarkers that can optimise the use of these therapies to maximise efficacy and avoid unnecessary toxicity. However, it is important to first define the changes in potential biomarkers following cytotoxic chemotherapy alone. This study reports the impact of standard cytotoxic chemotherapy across a range of circulating and imaging biomarkers. METHODS: A single-centre, prospective, biomarker-driven study. Eligible patients included those diagnosed with colorectal cancer with liver metastases that were planned to receive first line oxaliplatin plus 5-fluorouracil or capecitabine. Patients underwent paired blood sampling and magnetic resonance imaging (MRI), and biomarkers were associated with progression-free survival (PFS) and overall survival (OS). RESULTS: Twenty patients were recruited to the study. Data showed that chemotherapy significantly reduced the number of circulating tumour cells as well as the circulating concentrations of Ang1, Ang2, VEGF-A, VEGF-C and VEGF-D from pre-treatment to cycle 2 day 2. The changes in circulating concentrations were not associated with PFS or OS. On average, the MRI perfusion/permeability parameter, Ktrans, increased in response to cytotoxic chemotherapy from pre-treatment to cycle 2 day 2 and this increase was associated with worse OS (HR 1.099, 95%CI 1.01-1.20, p = 0.025). CONCLUSIONS: In patients diagnosed with colorectal cancer with liver metastases, treatment with standard chemotherapy changes cell- and protein-based biomarkers, although these changes are not associated with survival outcomes. In contrast, the imaging biomarker, Ktrans, offers promise to direct molecularly targeted therapies such as anti-angiogenic agents.


Assuntos
Biomarcadores Tumorais/metabolismo , Capecitabina/uso terapêutico , Fluoruracila/uso terapêutico , Oxaliplatina/uso terapêutico , Idoso , Capecitabina/farmacologia , Feminino , Fluoruracila/farmacologia , Humanos , Masculino , Metástase Neoplásica , Oxaliplatina/farmacologia , Estudos Prospectivos
8.
Eur Radiol ; 31(8): 6001-6012, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33492473

RESUMO

Existing quantitative imaging biomarkers (QIBs) are associated with known biological tissue characteristics and follow a well-understood path of technical, biological and clinical validation before incorporation into clinical trials. In radiomics, novel data-driven processes extract numerous visually imperceptible statistical features from the imaging data with no a priori assumptions on their correlation with biological processes. The selection of relevant features (radiomic signature) and incorporation into clinical trials therefore requires additional considerations to ensure meaningful imaging endpoints. Also, the number of radiomic features tested means that power calculations would result in sample sizes impossible to achieve within clinical trials. This article examines how the process of standardising and validating data-driven imaging biomarkers differs from those based on biological associations. Radiomic signatures are best developed initially on datasets that represent diversity of acquisition protocols as well as diversity of disease and of normal findings, rather than within clinical trials with standardised and optimised protocols as this would risk the selection of radiomic features being linked to the imaging process rather than the pathology. Normalisation through discretisation and feature harmonisation are essential pre-processing steps. Biological correlation may be performed after the technical and clinical validity of a radiomic signature is established, but is not mandatory. Feature selection may be part of discovery within a radiomics-specific trial or represent exploratory endpoints within an established trial; a previously validated radiomic signature may even be used as a primary/secondary endpoint, particularly if associations are demonstrated with specific biological processes and pathways being targeted within clinical trials. KEY POINTS: • Data-driven processes like radiomics risk false discoveries due to high-dimensionality of the dataset compared to sample size, making adequate diversity of the data, cross-validation and external validation essential to mitigate the risks of spurious associations and overfitting. • Use of radiomic signatures within clinical trials requires multistep standardisation of image acquisition, image analysis and data mining processes. • Biological correlation may be established after clinical validation but is not mandatory.


Assuntos
Radiologia , Tomografia Computadorizada por Raios X , Biomarcadores , Consenso , Humanos , Processamento de Imagem Assistida por Computador
9.
Radiographics ; 41(6): 1717-1732, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34597235

RESUMO

Radiomics refers to the extraction of mineable data from medical imaging and has been applied within oncology to improve diagnosis, prognostication, and clinical decision support, with the goal of delivering precision medicine. The authors provide a practical approach for successfully implementing a radiomic workflow from planning and conceptualization through manuscript writing. Applications in oncology typically are either classification tasks that involve computing the probability of a sample belonging to a category, such as benign versus malignant, or prediction of clinical events with a time-to-event analysis, such as overall survival. The radiomic workflow is multidisciplinary, involving radiologists and data and imaging scientists, and follows a stepwise process involving tumor segmentation, image preprocessing, feature extraction, model development, and validation. Images are curated and processed before segmentation, which can be performed on tumors, tumor subregions, or peritumoral zones. Extracted features typically describe the distribution of signal intensities and spatial relationship of pixels within a region of interest. To improve model performance and reduce overfitting, redundant and nonreproducible features are removed. Validation is essential to estimate model performance in new data and can be performed iteratively on samples of the dataset (cross-validation) or on a separate hold-out dataset by using internal or external data. A variety of noncommercial and commercial radiomic software applications can be used. Guidelines and artificial intelligence checklists are useful when planning and writing up radiomic studies. Although interest in the field continues to grow, radiologists should be familiar with potential pitfalls to ensure that meaningful conclusions can be drawn. Online supplemental material is available for this article. Published under a CC BY 4.0 license.


Assuntos
Inteligência Artificial , Processamento de Imagem Assistida por Computador , Diagnóstico por Imagem , Humanos , Oncologia , Radiografia
10.
Int J Gynecol Cancer ; 31(11): 1459-1470, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34593564

RESUMO

The annual global incidence of cervical cancer is approximately 604 000 cases/342 000 deaths, making it the fourth most common cancer in women. Cervical cancer is a major healthcare problem in low and middle income countries where 85% of new cases and deaths occur. Secondary prevention measures have reduced incidence and mortality in developed countries over the past 30 years, but cervical cancer remains a major cause of cancer deaths in women. For women who present with Fédération Internationale de Gynécologie et d'Obstétrique (FIGO 2018) stages IB3 or upwards, chemoradiation is the established treatment. Despite high rates of local control, overall survival is less than 50%, largely due to distant relapse. Reducing the health burden of cervical cancer requires greater individualization of treatment, identifying those at risk of relapse and progression for modified or intensified treatment. Hypoxia is a well known feature of solid tumors and an established therapeutic target. Low tumorous oxygenation increases the risk of local invasion, metastasis and treatment failure. While meta-analyses show benefit, many individual trials targeting hypoxia failed in part due to not selecting patients most likely to benefit. This review summarizes the available hypoxia-targeted strategies and identifies further research and new treatment paradigms needed to improve patient outcomes. The applications and limitations of hypoxia biomarkers for treatment selection and response monitoring are discussed. Finally, areas of greatest unmet clinical need are identified to measure and target hypoxia and therefore improve cervical cancer outcomes.


Assuntos
Quimiorradioterapia/métodos , Hipóxia Tumoral/fisiologia , Neoplasias do Colo do Útero/terapia , Biomarcadores/análise , Feminino , Saúde Global , Humanos , Tomografia por Emissão de Pósitrons , Hipóxia Tumoral/efeitos dos fármacos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/mortalidade , Neoplasias do Colo do Útero/patologia
11.
Magn Reson Med ; 84(3): 1250-1263, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32057115

RESUMO

PURPOSE: MRI biomarkers of tumor response to treatment are typically obtained from parameters derived from a model applied to pre-treatment and post-treatment data. However, as tumors are spatially and temporally heterogeneous, different models may be necessary in different tumor regions, and model suitability may change over time. This work evaluates how the suitability of two diffusion-weighted (DW) MRI models varies spatially within tumors at the voxel level and in response to radiotherapy, potentially allowing inference of qualitatively different tumor microenvironments. METHODS: DW-MRI data were acquired in CT26 subcutaneous allografts before and after radiotherapy. Restricted and time-independent diffusion models were compared, with regions well-described by the former hypothesized to reflect cellular tissue, and those well-described by the latter expected to reflect necrosis or oedema. Technical and biological validation of the percentage of tissue described by the restricted diffusion microstructural model (termed %MM) was performed through simulations and histological comparison. RESULTS: Spatial and radiotherapy-related variation in model suitability was observed. %MM decreased from a mean of 64% at baseline to 44% 6 days post-radiotherapy in the treated group. %MM correlated negatively with the percentage of necrosis from histology, but overestimated it due to noise. Within MM regions, microstructural parameters were sensitive to radiotherapy-induced changes. CONCLUSIONS: There is spatial and radiotherapy-related variation in different models' suitability for describing diffusion in tumor tissue, suggesting the presence of different and changing tumor sub-regions. The biological and technical validation of the proposed %MM cancer imaging biomarker suggests it correlates with, but overestimates, the percentage of necrosis.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias , Difusão , Humanos , Imageamento por Ressonância Magnética , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Microambiente Tumoral
12.
Eur Radiol ; 30(11): 6241-6250, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32483644

RESUMO

OBJECTIVE: To investigate the effects of Image Biomarker Standardisation Initiative (IBSI) compliance, harmonisation of calculation settings and platform version on the statistical reliability of radiomic features and their corresponding ability to predict clinical outcome. METHODS: The statistical reliability of radiomic features was assessed retrospectively in three clinical datasets (patient numbers: 108 head and neck cancer, 37 small-cell lung cancer, 47 non-small-cell lung cancer). Features were calculated using four platforms (PyRadiomics, LIFEx, CERR and IBEX). PyRadiomics, LIFEx and CERR are IBSI-compliant, whereas IBEX is not. The effects of IBSI compliance, user-defined calculation settings and platform version were assessed by calculating intraclass correlation coefficients and confidence intervals. The influence of platform choice on the relationship between radiomic biomarkers and survival was evaluated using univariable cox regression in the largest dataset. RESULTS: The reliability of radiomic features calculated by the different software platforms was only excellent (ICC > 0.9) for 4/17 radiomic features when comparing all four platforms. Reliability improved to ICC > 0.9 for 15/17 radiomic features when analysis was restricted to the three IBSI-compliant platforms. Failure to harmonise calculation settings resulted in poor reliability, even across the IBSI-compliant platforms. Software platform version also had a marked effect on feature reliability in CERR and LIFEx. Features identified as having significant relationship to survival varied between platforms, as did the direction of hazard ratios. CONCLUSION: IBSI compliance, user-defined calculation settings and choice of platform version all influence the statistical reliability and corresponding performance of prognostic models in radiomics. KEY POINTS: • Reliability of radiomic features varies between feature calculation platforms and with choice of software version. • Image Biomarker Standardisation Initiative (IBSI) compliance improves reliability of radiomic features across platforms, but only when calculation settings are harmonised. • IBSI compliance, user-defined calculation settings and choice of platform version collectively affect the prognostic value of features.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Carcinoma de Pequenas Células do Pulmão/diagnóstico por imagem , Software , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Prognóstico , Modelos de Riscos Proporcionais , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
13.
Nucleic Acids Res ; 46(11): 5822-5836, 2018 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-29596649

RESUMO

Nonsense-mediated mRNA decay (NMD) is important for RNA quality control and gene regulation in eukaryotes. NMD targets aberrant transcripts for decay and also directly influences the abundance of non-aberrant transcripts. In animals, the SMG1 kinase plays an essential role in NMD by phosphorylating the core NMD factor UPF1. Despite SMG1 being ubiquitous throughout the plant kingdom, little is known about its function, probably because SMG1 is atypically absent from the genome of the model plant, Arabidopsis thaliana. By combining our previously established SMG1 knockout in moss with transcriptome-wide analysis, we reveal the range of processes involving SMG1 in plants. Machine learning assisted analysis suggests that 32% of multi-isoform genes produce NMD-targeted transcripts and that splice junctions downstream of a stop codon act as the major determinant of NMD targeting. Furthermore, we suggest that SMG1 is involved in other quality control pathways, affecting DNA repair and the unfolded protein response, in addition to its role in mRNA quality control. Consistent with this, smg1 plants have increased susceptibility to DNA damage, but increased tolerance to unfolded protein inducing agents. The potential involvement of SMG1 in RNA, DNA and protein quality control has major implications for the study of these processes in plants.


Assuntos
Bryopsida/enzimologia , Bryopsida/genética , Degradação do RNAm Mediada por Códon sem Sentido , Fosfotransferases/fisiologia , Proteínas de Plantas/fisiologia , Regiões 3' não Traduzidas , Bryopsida/metabolismo , Dano ao DNA , Expressão Gênica , Mutação , Fosfotransferases/genética , Proteínas de Plantas/genética , Resposta a Proteínas não Dobradas
14.
Semin Cell Dev Biol ; 64: 48-57, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27717679

RESUMO

There is interest in identifying and quantifying tumor heterogeneity at the genomic, tissue pathology and clinical imaging scales, as this may help better understand tumor biology and may yield useful biomarkers for guiding therapy-based decision making. This review focuses on the role and value of using x-ray, CT, MRI and PET based imaging methods that identify, measure and map tumor heterogeneity. In particular we highlight the potential value of these techniques and the key challenges required to validate and qualify these biomarkers for clinical use.


Assuntos
Diagnóstico por Imagem/métodos , Heterogeneidade Genética , Neoplasias/diagnóstico , Neoplasias/genética , Biomarcadores Tumorais/metabolismo , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional
16.
Trop Med Int Health ; 24(6): 671-691, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30843627

RESUMO

OBJECTIVE: A myriad of physical and psychosocial sequelae have been reported among Ebola survivors from previous Ebola virus disease (EVD) outbreaks, including the most recent in West Africa. This review examines the various forms of psychological distress experienced by EVD survivors, family and community reactions to EVD survivors and EVD survivors' coping mechanisms. METHODS: We conducted a literature search of original articles employing Medline (Ovid), PubMed, Web of Science, Scopus, CINAHL, EBSCO host academic search complete, PsycINFO (EBSCO) and Embase databases. RESULTS: Our search identified 1890 articles of which 24 met our inclusion criteria. Various forms of psychological distress were prevalent among EVD survivors including depression, anxiety, anger, grief, guilt, flashbacks, sadness, worthlessness, substance addiction, suicidal tendencies and self-stigmatisation. Family and community responses to EVD survivors ranged from acceptance to rejection, isolation, stigmatisation and discrimination. EVD survivors' coping strategies included engagement with religious faith, EVD survivors associations and involvement in EVD prevention and control interventions. CONCLUSION: Psychological distress, including that resulting from family and community stigma and discrimination, appears common among EVD survivors. Community-based mental health and psychosocial interventions integrated within a broader package of care for EVD survivors that also recognises the physical health challenges are required. Well-designed longitudinal studies can provide clear insights on the nature and trajectory of the psychosocial issues currently experienced by EVD survivors.


OBJECTIF: Une myriade de séquelles physiques et psychosociales a été rapportée parmi les survivants d'Ebola lors des épidémies précédentes de la maladie du virus Ebola (MVE) et dans la plus récente en Afrique de l'Ouest. Cette revue examine les différentes formes de détresse psychologique vécue par les survivants de la MVE, les réactions de la famille et de la communauté à l'égard des survivants de la MVE et leurs mécanismes d'adaptation. MÉTHODES: Nous avons effectué une recherche de la littérature dans des articles originaux en utilisant les bases de données Medline (Ovid), PubMed, Web of Science, Scopus, CINAHL, EBSCO host academic search complete, PsycINFO (EBSCO) et Embase. RÉSULTATS: Notre recherche a identifié 1.890 articles dont 24 répondaient aux critères d'inclusion. Diverses formes de détresse psychologique étaient prévalentes parmi les survivants de la MVE, notamment la dépression, l'anxiété, la colère, le deuil, la culpabilité, les flashbacks, la tristesse, le sentiment d'inutilité, la toxicomanie, les tendances suicidaires et l'auto-stigmatisation. Les réactions des familles et des communautés vis-à-vis des survivants de la MVE vont de l'acceptation au rejet, à l'isolement, à la stigmatisation et à la discrimination. Les stratégies d'adaptation des survivants de la MVE comprenaient l'engagement avec la religion, dans les associations de survivants de la MVE et une implication dans des interventions de prévention et de lutte contre la MVE. CONCLUSION: La détresse psychologique, y compris celle résultant de la stigmatisation et de la discrimination familiale et communautaire, semble être fréquente chez les survivants de la MVE. Des interventions communautaires intégrées psychosociales et de santé mentale dans un ensemble plus large de soins pour les survivants de la MVE, qui reconnaît également les problèmes de santé physique sont nécessaires. Des études longitudinales bien conçues peuvent fournir des informations claires sur la nature et la trajectoire des problèmes psychosociaux actuellement rencontrés par les survivants de la MVE.


Assuntos
Adaptação Psicológica , Família/psicologia , Doença pelo Vírus Ebola/psicologia , Estresse Psicológico/epidemiologia , Sobreviventes/psicologia , Serviços Comunitários de Saúde Mental , Surtos de Doenças , Doença pelo Vírus Ebola/epidemiologia , Humanos , Estigma Social
17.
Radiology ; 288(3): 739-747, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29869970

RESUMO

Purpose To cross-validate T1-weighted oxygen-enhanced (OE) MRI measurements of tumor hypoxia with intrinsic susceptibility MRI measurements and to demonstrate the feasibility of translation of the technique for patients. Materials and Methods Preclinical studies in nine 786-0-R renal cell carcinoma (RCC) xenografts and prospective clinical studies in eight patients with RCC were performed. Longitudinal relaxation rate changes (∆R1) after 100% oxygen inhalation were quantified, reflecting the paramagnetic effect on tissue protons because of the presence of molecular oxygen. Native transverse relaxation rate (R2*) and oxygen-induced R2* change (∆R2*) were measured, reflecting presence of deoxygenated hemoglobin molecules. Median and voxel-wise values of ∆R1 were compared with values of R2* and ∆R2*. Tumor regions with dynamic contrast agent-enhanced MRI perfusion, refractory to signal change at OE MRI (referred to as perfused Oxy-R), were distinguished from perfused oxygen-enhancing (perfused Oxy-E) and nonperfused regions. R2* and ∆R2* values in each tumor subregion were compared by using one-way analysis of variance. Results Tumor-wise and voxel-wise ∆R1 and ∆R2* comparisons did not show correlative relationships. In xenografts, parcellation analysis revealed that perfused Oxy-R regions had faster native R2* (102.4 sec-1 vs 81.7 sec-1) and greater negative ∆R2* (-22.9 sec-1 vs -5.4 sec-1), compared with perfused Oxy-E and nonperfused subregions (all P < .001), respectively. Similar findings were present in human tumors (P < .001). Further, perfused Oxy-R helped identify tumor hypoxia, measured at pathologic analysis, in both xenografts (P = .002) and human tumors (P = .003). Conclusion Intrinsic susceptibility biomarkers provide cross validation of the OE MRI biomarker perfused Oxy-R. Consistent relationship to pathologic analyses was found in xenografts and human tumors, demonstrating biomarker translation. Published under a CC BY 4.0 license. Online supplemental material is available for this article.


Assuntos
Carcinoma de Células Renais/fisiopatologia , Hipóxia/fisiopatologia , Aumento da Imagem/métodos , Neoplasias Renais/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Animais , Biomarcadores , Carcinoma de Células Renais/complicações , Carcinoma de Células Renais/diagnóstico por imagem , Modelos Animais de Doenças , Estudos de Viabilidade , Feminino , Humanos , Hipóxia/complicações , Hipóxia/diagnóstico por imagem , Rim/diagnóstico por imagem , Rim/patologia , Rim/fisiopatologia , Neoplasias Renais/complicações , Neoplasias Renais/diagnóstico por imagem , Masculino , Camundongos , Pessoa de Meia-Idade , Oxigênio , Estudos Prospectivos , Reprodutibilidade dos Testes
18.
Magn Reson Med ; 79(4): 2236-2245, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28856728

RESUMO

PURPOSE: Previous work has shown that combining dynamic contrast-enhanced (DCE)-MRI and oxygen-enhanced (OE)-MRI binary enhancement maps can identify tumor hypoxia. The current work proposes a novel, data-driven method for mapping tissue oxygenation and perfusion heterogeneity, based on clustering DCE/OE-MRI data. METHODS: DCE-MRI and OE-MRI were performed on nine U87 (glioblastoma) and seven Calu6 (non-small cell lung cancer) murine xenograft tumors. Area under the curve and principal component analysis features were calculated and clustered separately using Gaussian mixture modelling. Evaluation metrics were calculated to determine the optimum feature set and cluster number. Outputs were quantitatively compared with a previous non data-driven approach. RESULTS: The optimum method located six robustly identifiable clusters in the data, yielding tumor region maps with spatially contiguous regions in a rim-core structure, suggesting a biological basis. Mean within-cluster enhancement curves showed physiologically distinct, intuitive kinetics of enhancement. Regions of DCE/OE-MRI enhancement mismatch were located, and voxel categorization agreed well with the previous non data-driven approach (Cohen's kappa = 0.61, proportional agreement = 0.75). CONCLUSION: The proposed method locates similar regions to the previous published method of binarization of DCE/OE-MRI enhancement, but renders a finer segmentation of intra-tumoral oxygenation and perfusion. This could aid in understanding the tumor microenvironment and its heterogeneity. Magn Reson Med 79:2236-2245, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias/diagnóstico por imagem , Neoplasias/patologia , Hipóxia Tumoral , Microambiente Tumoral , Algoritmos , Animais , Área Sob a Curva , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Análise por Conglomerados , Glioblastoma/diagnóstico por imagem , Humanos , Hipóxia , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Neoplasias Pulmonares/diagnóstico por imagem , Camundongos , Transplante de Neoplasias , Distribuição Normal , Oxigênio/metabolismo , Perfusão , Análise de Componente Principal , Reprodutibilidade dos Testes , Software
19.
J Magn Reson Imaging ; 44(2): 335-45, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26898173

RESUMO

PURPOSE: To evaluate blood oxygenation level-dependent (BOLD) contrast changes in healthy breast parenchyma and breast carcinoma during administration of vasoactive gas stimuli. MATERIALS AND METHODS: Magnetic resonance imaging (MRI) was performed at 3T in 19 healthy premenopausal female volunteers using a single-shot fast spin echo sequence to acquire dynamic T2 -weighted images. 2% (n = 9) and 5% (n = 10) carbogen gas mixtures were interleaved with either medical air or oxygen in 2-minute blocks, for four complete cycles. A 12-minute medical air breathing period was used to determine background physiological modulation. Pixel-wise correlation analysis was applied to evaluate response to the stimuli in breast parenchyma and these results were compared to the all-air control. The relative BOLD effect size was compared between two groups of volunteers scanned in different phases of the menstrual cycle. The optimal stimulus design was evaluated in five breast cancer patients. RESULTS: Of the four stimulus combinations tested, oxygen vs. 5% carbogen produced a response that was significantly stronger (P < 0.05) than air-only breathing in volunteers. Subjects imaged during the follicular phase of their cycle when estrogen levels typically peak exhibited a significantly smaller BOLD response (P = 0.01). Results in malignant tissue were variable, with three out of five lesions exhibiting a diminished response to the gas stimulus. CONCLUSION: Oxygen vs. 5% carbogen is the most robust stimulus for inducing BOLD contrast, consistent with the opposing vasomotor effects of these two gases. Measurements may be confounded by background physiological fluctuations and menstrual cycle changes. J. Magn. Reson. Imaging 2016;44:335-345.


Assuntos
Neoplasias da Mama/sangue , Neoplasias da Mama/diagnóstico por imagem , Mama/metabolismo , Imageamento por Ressonância Magnética/métodos , Neovascularização Patológica/sangue , Oximetria/métodos , Oxigênio/sangue , Adulto , Idoso , Mama/diagnóstico por imagem , Neoplasias da Mama/irrigação sanguínea , Feminino , Humanos , Pessoa de Meia-Idade , Neovascularização Patológica/diagnóstico por imagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sistema Vasomotor/diagnóstico por imagem , Sistema Vasomotor/metabolismo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa