Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Biochem Biophys Res Commun ; 481(1-2): 25-30, 2016 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-27833022

RESUMO

Cancer cells overcome cellular senescence by activating the telomere maintenance mechanism, which can be either through telomerase or the alternative lengthening of telomeres (ALT). Being exclusive to cancer cells, targeting ALT is a more promising route for the development of drugs against cancer. The histone deacetylase (HDAC) family plays significant roles in various cellular processes. In addition to the regulation of gene expression, HDACs are also known to directly interact with many proteins. We focused on this family, and found that HDAC9 was up-regulated in ALT-positive cells. In ALT-positive cells treated with HDAC9 siRNA, there was a decrease in the telomere replicative capacity, which was evident from the C-circles assay. Furthermore, the formation of ALT-associated promyelocytic leukemia (PML) nuclear bodies (APBs) was inhibited by HDAC9 knockdown. Based on this study, it is suggested that HDAC9 regulates the formation of APBs and could be a candidate for the target of ALT-cancer therapy.


Assuntos
Histona Desacetilases/metabolismo , Neoplasias Experimentais/metabolismo , Neoplasias Experimentais/patologia , Proteínas Repressoras/metabolismo , Homeostase do Telômero , Telômero/patologia , Linhagem Celular Tumoral , Células HeLa , Humanos
2.
Heliyon ; 10(10): e30715, 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38774337

RESUMO

Ascorbic acid plays a significant role in regulation of various bodily functions with high concentrations in immune cells and being involved in connective tissue maintenance. Commonly it is detected through various colorimetric methods. In this study, we propose a one-step simple method based on the inhibitory activity of ascorbic acid on horseradish peroxidase and hydrogen peroxide. The detection is observed by colorimetric changes to TMB (3,3',5,5' tetramethylbenzidine). The enzyme inhibition unit was optimized with a high level of linearity (r2 = 0.9999) and the level of detection and level of quantification were found to be 1.35 nM and 4.08 nM, respectively with higher sensitive compared to the HPLC method (11 µM). Both intra and inter-assays showed high correlations at different AA concentrations. (r2 > 0.9999). Similar results were also observed for vitamin C tablets, ascorbate salts, fruits, and market products (r2 = 0.999). There was negligible effect of interference by citric acid, lactic acid, tartaric acids, and glucose with high recoveries (>98%) at 1 mg/mL to 0.0078 mg/mL concentration ranges. The recovery error (RE%) was found to be less than 10%. Our detection method is distinguished by its simplicity, nano-level of detection, reproducibility, and potential application and adaptability as a point-of-use test.

3.
PLoS One ; 19(7): e0303706, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39042609

RESUMO

Serine proteases (SPs) are distributed among all living cells accounting for almost one-third of all proteases. Dysregulation of SPs during inflammation and/or infection can result in devastating consequences, such as skin and lung inflammation, neuroinflammation, arthritis, as well as metastasis of cancerous cells. Such activities are tightly regulated by various inhibitors known as serine protease inhibitors (SERPIN). The thermodynamic investigations previously revealed that L-ascorbic acid binds to trypsin more firmly than pepsin and the binding force of L-ascorbic acid is driven by hydrogen bonds and van der Waals forces. However, the physiochemical effects of such interaction on trypsin and/or pepsin have not yet been reported. Ascorbic acid, also known as vitamin C, is one of the essential nutrients and most common food supplements, fortificants, and preservatives. The aim of this study was to explore the inhibitory effects of ascorbic acid on serine proteases at various concentrations on the in-vitro digestion and/or hydrolysis of intercellular matrix of cell monolayer and human serum albumin (HSA). The inhibitory effects of ascorbic on trypsin are investigated by qualitative and quantitative analysis using SDS-PAGE imaging and NIH densitometric software. Upon the addition of ascorbic acid in both indicator systems, the detachment and/or dissociation of cell monolayer and the digestion of HSA were inhibited in the presence of EDTA-Trypsin. The inhibitory effect of ascorbic acid on the digestion of intercellular matrix and/or hydrolysis of HSA showed a dose-dependent trend until it reached the maximum extent of inhibition. At an equal concentration (2.5mg/mL) ascorbic acid and EDTA-Trypsin exhibited the most potent inhibitory effect on the in vitro digestion of protein either in the form of intercellular matrix in cell monolayer and/or HSA respectively. Overall, our results based on two indicator systems strongly indicate that ascorbic acid may function as a serine protease inhibitor (SERPIN) beyond other important functions.


Assuntos
Ácido Ascórbico , Inibidores de Serina Proteinase , Humanos , Ácido Ascórbico/farmacologia , Ácido Ascórbico/química , Inibidores de Serina Proteinase/farmacologia , Inibidores de Serina Proteinase/química , Inibidores de Serina Proteinase/metabolismo , Neoplasias Pulmonares/metabolismo , Neoplasias Pulmonares/patologia , Albumina Sérica Humana/metabolismo , Albumina Sérica Humana/química , Tripsina/metabolismo , Tripsina/química , Linhagem Celular Tumoral , Células A549
4.
Heliyon ; 10(5): e26348, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38439842

RESUMO

In this study, we constructed an UV-C illumination chamber using commercially available germicidal lamps and other locally available low-cost components for general-purpose biological decontamination purposes. The illumination chamber provides uniform illumination of around 1 J/cm2 in under 5 min across the chamber. The control mechanism was developed to automate the on/off process and make it more secure minimizing health and other electrical safety. To validate the decontamination efficacy of the UV-C Illumination Chamber we performed the Geobacillus spore strip culture assay. Additionally, we performed the viral load measurement by identifying the COVID-19-specific N-gene and ORF1 gene on surgical masks. The gold standard RT-qPCR measurement was performed to detect and quantify the COVID-19-specific gene on the mask sample. The biochemical assay was conducted on the control and test group to identify the presence of different types of bacteria, and fungi before and after exposure under the illumination chamber. The findings of our study revealed satisfactory decontamination efficacy test results. Therefore, it could be an excellent device in healthcare settings as a disinfection tool for biological decontamination such as SAR-CoV-2 virus, personal protection equipment (PPE), (including n95, k95 respirators, and surgical masks), and other common pathogens.

5.
Vaccines (Basel) ; 12(5)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38793733

RESUMO

COVID-19 vaccination strategies, including heterologous prime-boost regimens and additional booster doses, aim to optimize immune responses. However, seroepidemiological studies on immune responses to different COVID-19 vaccine types and schedules remain limited. This study investigated antibody levels following homologous and heterologous prime-and-boost COVID-19 vaccination in Bangladesh. In a cohort of 606 participants who received first/second/booster doses of vaccines (AstraZeneca, Moderna, Pfizer-BioNTech, and Sinopharm), anti-spike IgG and anti-nucleocapsid IgG levels were measured. Antibody titer variations with respect to age, gender, intervals between doses, and prior infection status were analyzed. mRNA vaccines elicited the highest antibody levels after homologous and heterologous boosting. The AstraZeneca booster resulted in a sharp titer decline rate of ~0.04 units per day. Second or booster vaccine doses significantly increased antibody levels, especially in males (p < 0.05). Older age correlated with higher titers, likely reflecting previous infection, which was further confirmed by the elevation of anti-nucleocapsid IgG levels. About 95.5% of non-Sinopharm recipients were anti-nucleocapsid IgG positive, suggesting prior exposure exceeding self-reported infections (12.5%). mRNA and heterologous COVID-19 boosting enhances humoral immunity over homologous prime-boost vector/inactivated vaccination. However, waning immunity merits further investigation across vaccine platforms.

6.
Cureus ; 15(10): e47683, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37899905

RESUMO

Introduction The overlap in clinical presentation between COVID-19 and dengue poses challenges for diagnosis in co-endemic regions. Furthermore, there have been reports of antibody cross-reactivity between SARS-CoV-2 and dengue. Our research aims to evaluate SARS-CoV-2 antigens for serological testing while reducing the possibility of cross-reactivity with anti-dengue antibodies. Method Two hundred and ten serum samples were collected from 179 patients and divided into four panels. Panels 1 and 2 consisted of COVID-19-negative healthy donors (n=81) and pre-pandemic dengue patients (n=50), respectively. Alternatively, Panel 3 (n=19) was composed of reverse transcription-quantitative polymerase chain reaction (RT-qPCR)-positive samples collected within two weeks of COVID-19 symptom onset, while Panel 4 (n=60) was composed of positive samples collected after two weeks of symptom onset. Previously developed and characterized in-house SARS-CoV-2 spike-1 (S1), receptor binding domain (RBD), and nucleocapsid (N) immunoglobin G (IgG)-enzyme-linked immunosorbent assay (ELISA) assays were used for the study. Results Six dengue-positive sera cross-reacted with the RBD of SARS-CoV-2. However, only one dengue-positive sera cross-reacted with the S1 and N proteins of SARS-CoV-2. Co-immobilization of S1 and RBD in different ratios revealed an 80:20 (S1:RBD) ratio as optimal for achieving an overall 96.2% sensitivity with the least cross-reaction to anti-dengue antibodies. Conclusion Our findings indicated that SARS-CoV-2 RBD-based immunoassays present more cross-reactivity with anti-dengue antibodies than S1 and N proteins. Furthermore, co-immobilization of S1 and RBD reduces the cross-reactivity with anti-dengue antibodies compared to RBD, thereby increasing the immunoassay specificity without affecting overall sensitivity for the dengue-endemic areas.

7.
Artigo em Inglês | MEDLINE | ID: mdl-36733464

RESUMO

During the COVID-19 pandemic, several priority diseases were not getting sufficient attention. Whilst breast cancer is a fatal disease affecting millions worldwide, identification and management of these patients did not initially attract critical attention to minimize the impact of lockdown, post-lockdown, and other measures. Breast cancer patients' conditions may not remain stable without proper care, worsening their prognosis. Proper care includes the timely instigation of surgery, systemic therapy, and psychological support. This includes low-and middle-income countries where there are already concerns with available personnel and medicines to adequately identify and treat these patients. Consequently, there was a need to summarize the current scenario regarding managing breast cancer care during COVID-19 across all countries, including any guidelines developed. We systematically searched three scientific databases and found 76 eligible articles covering the medical strategies of high-income countries versus LMICs. Typically, diagnostic facilities in hospitals were affected at the beginning of the pandemic following the lockdown and other measures. This resulted in more advanced-stage cancers being detected at initial presentation across countries, negatively impacting patient outcomes. Other than increased telemedicine, instigating neo-adjuvant endocrine therapy more often, reducing non-essential visits, and increasing the application of neo-adjuvant chemotherapy to meet the challenges, encouragingly, there was no other significant difference among patients in high-income versus LMICs. Numerous guidelines regarding patient management evolved during the pandemic to address the challenges posed by lockdowns and other measures, which were subsequently adopted by various high-income countries and LMICs to improve patient care. The psychological impact of COVID-19 and associated lockdown measures, especially during the peak of COVID-19 waves, and the subsequent effect on the patient's mental health must also be considered in this high-priority group. We will continue to monitor the situation to provide direction in future pandemics.

8.
Life (Basel) ; 12(5)2022 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-35629317

RESUMO

With the progression of the COVID-19 pandemic, new technologies are being implemented for more rapid, scalable, and sensitive diagnostics. The implementation of microfluidic techniques and their amalgamation with different detection techniques has led to innovative diagnostics kits to detect SARS-CoV-2 antibodies, antigens, and nucleic acids. In this review, we explore the different microfluidic-based diagnostics kits and how their amalgamation with the various detection techniques has spearheaded their availability throughout the world. Three other online databases, PubMed, ScienceDirect, and Google Scholar, were referred for articles. One thousand one hundred sixty-four articles were determined with the search algorithm of microfluidics followed by diagnostics and SARS-CoV-2. We found that most of the materials used to produce microfluidics devices were the polymer materials such as PDMS, PMMA, and others. Centrifugal force is the most commonly used fluid manipulation technique, followed by electrochemical pumping, capillary action, and isotachophoresis. The implementation of the detection technique varied. In the case of antibody detection, spectrometer-based detection was most common, followed by fluorescence-based as well as colorimetry-based. In contrast, antigen detection implemented electrochemical-based detection followed by fluorescence-based detection, and spectrometer-based detection were most common. Finally, nucleic acid detection exclusively implements fluorescence-based detection with a few colorimetry-based detections. It has been further observed that the sensitivity and specificity of most devices varied with implementing the detection-based technique alongside the fluid manipulation technique. Most microfluidics devices are simple and incorporate the detection-based system within the device. This simplifies the deployment of such devices in a wide range of environments. They can play a significant role in increasing the rate of infection detection and facilitating better health services.

9.
Expert Rev Anti Infect Ther ; 20(3): 473-481, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34477019

RESUMO

BACKGROUND: Rapid increase in COVID-19 suspected cases has rendered disease diagnosis challenging, mainly depending upon RT-qPCR. Reliable, rapid, and cost-effective diagnostic assays that complement RT-qPCR should be introduced after thoroughly evaluating their performance upon various disease phases, viral load, and sample storage conditions. OBJECTIVE: We investigated the correlation of cycle threshold (Ct) value, which implies the viral load and infection phase, and the storage condition of the clinical specimen with the diagnosis of SARS-CoV-2 through our newly developed in-house rapid enzyme-linked immunosorbent assay (ELISA) system. METHOD: Naso-oropharyngeal samples of 339 COVID-19 suspected cases were collected and evaluated through RT-qPCR that were stored up to 30 days in different conditions (i.e. -80°C, -20°C and initially at 4°C followed by -80°C). The clinical specimens were evaluated with our in-house ELISA system after finalizing the assay method through checkerboard assay and minimizing the signal/noise ratio. RESULT: The ELISA system showed the highest sensitivity (92.9%) for samples with Ct ≤30 and preserving at -80°C temperature. The sensitivity reduced proportionally with increasing Ct value and preserving temperature. However, the specificity ranged between 98.3% and 100%. CONCLUSION: The results indicate the necessity of early infection phase diagnosis and lower temperature preservation of samples to perform rapid antigen ELISA tests.


Assuntos
COVID-19 , SARS-CoV-2 , Manejo de Espécimes , Carga Viral , COVID-19/diagnóstico , Ensaio de Imunoadsorção Enzimática , Humanos , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade
10.
Biomed Pharmacother ; 146: 112610, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35062074

RESUMO

Neurodegenerative disorders (NDs) including Alzheimer's disease, Parkinson's disease, amyotrophic lateral sclerosis, Huntington's disease, and multiple sclerosis have various disease-specific causal factors and pathological features. A very common characteristic of NDs is oxidative stress (OS), which takes place due to the elevated generation of reactive oxygen species during the progression of NDs. Furthermore, the pathological condition of NDs including an increased level of protein aggregates can further lead to chronic inflammation because of the microglial activation. Carotenoids (CTs) are naturally occurring pigments that play a significant role in averting brain disorders. More than 750 CTs are present in nature, and they are widely available in plants, microorganisms, and animals. CTs are accountable for the red, yellow, and orange pigments in several animals and plants, and these colors usually indicate various types of CTs. CTs exert various bioactive properties because of its characteristic structure, including anti-inflammatory and antioxidant properties. Due to the protective properties of CTs, levels of CTs in the human body have been markedly linked with the prevention and treatment of multiple diseases including NDs. In this review, we have summarized the relationship between OS, neuroinflammation, and NDs. In addition, we have also particularly focused on the antioxidants and anti-inflammatory properties of CTs in the management of NDs.


Assuntos
Anti-Inflamatórios/uso terapêutico , Antioxidantes/uso terapêutico , Carotenoides/uso terapêutico , Doenças Neurodegenerativas/tratamento farmacológico , Anti-Inflamatórios/farmacologia , Antioxidantes/farmacologia , Carotenoides/classificação , Carotenoides/farmacologia , Humanos , Estresse Oxidativo/efeitos dos fármacos
11.
PLoS One ; 16(12): e0261984, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34962972

RESUMO

Differential expression of p53 has been reported in cervical cancer, primarily in tumor tissue biopsies. In this study, we examined the association of TP53 codon 47 and codon 72 polymorphisms and serum level expression of p53 in cervical cancer patients (n = 129) and healthy controls (n = 122). We found elevated levels of serum p53 protein levels in cervical cancer patients (p = 0.0442) compared to healthy controls. Moreover, we found higher levels of serum p53 in patients with grade-III tumor (p = 0.001) compared to healthy controls. Examination of SNPs showed TP53 Arg/Pro heterozygosity (adjusted OR = 2.126, 95% CI = 1.181-3.827, p = 0.012), Pro/Pro mutant homozygosity (adjusted OR = 3.564, 95% CI = 1.647-7.713, p = 0.001), along with the combined genotype (Arg/Pro+Pro/Pro) (adjusted OR 2.542, 95% CI = 1.517-4.260, p<0.001) significantly increases the risk of cervical cancer. Expression quantitative trait analysis revealed no significant association with protein expression. Our results represent for the first time the upregulation of serum p53 in cervical cancer in Bangladeshi women and supports the association of TP53 codon 72 polymorphisms with cervical cancer.


Assuntos
Genes p53 , Predisposição Genética para Doença , Polimorfismo de Nucleotídeo Único , Proteína Supressora de Tumor p53/sangue , Neoplasias do Colo do Útero/genética , Adulto , Bangladesh/epidemiologia , Biópsia , Estudos de Casos e Controles , Códon , Feminino , Genótipo , Heterozigoto , Humanos , Modelos Lineares , Pessoa de Meia-Idade , Razão de Chances , Locos de Características Quantitativas , Risco , Medição de Risco , Neoplasias do Colo do Útero/sangue
12.
J Inflamm Res ; 14: 2497-2506, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34163208

RESUMO

BACKGROUND: Dynamics and persistence of neutralizing and non-neutralizing antibodies can give us the knowledge required for serodiagnosis, disease management, and successful vaccine design and development. The disappearance of antibodies, absence of humoral immunity activation, and sporadic reinfection cases emphasize the importance of longitudinal antibody dynamics against variable structural antigens. METHODS: In this study, twenty-five healthy subjects working in a SARS-COV-2 serodiagnostic assay development project were enrolled, and their sign and symptoms were followed up to six months. Three subjects showed COVID-19-like symptoms, and three subjects' antibody dynamics were followed over 120 days by analyzing 516 samples. We have developed 12 different types of in-house ELISAs to observe the kinetics of IgG, IgM, and IgA against four SARS-CoV-2 proteins, namely nucleocapsid, RBD, S1, and whole spike (S1+S2). For the development of these assays, 30-104 pre-pandemic samples were taken as negative controls and 83 RT-qPCR positive samples as positive ones. RESULTS: All three subjects presented COVID-19-like symptoms twice, with mild symptoms in the first episode were severe in the second, and RT-qPCR confirmed the latter. The initial episode did not culminate with any significant antibody development, while a multifold increase in IgG antibodies characterized the second episode. Interestingly, IgG antibody development concurrent with IgM and IgA and persisted, whereas the latter two weans off rather quickly if appeared. CONCLUSION: Antibody kinetics observed in this study can provide a pathway to the successful development of sero-diagnostics and epidemiologists to predict the fate of vaccination currently in place.

13.
Int J Nanomedicine ; 16: 4739-4753, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34267520

RESUMO

BACKGROUND: Serological tests detecting severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) are widely used in seroprevalence studies and evaluating the efficacy of the vaccination program. Some of the widely used serological testing techniques are enzyme-linked immune-sorbent assay (ELISA), chemiluminescence immunoassay (CLIA), and lateral flow immunoassay (LFIA). However, these tests are plagued with low sensitivity or specificity, time-consuming, labor-intensive, and expensive. We developed a serological test implementing flow-through dot-blot assay (FT-DBA) for SARS-CoV-2 specific IgG detection, which provides enhanced sensitivity and specificity while being quick to perform and easy to use. METHODS: SARS-CoV-2 antigens were immobilized on nitrocellulose membrane to capture human IgG, which was then detected with anti-human IgG conjugated gold nanoparticle (hIgG-AuNP). A total of 181 samples were analyzed in-house. Within which 35 were further evaluated in US FDA-approved CLIA Elecsys SARS-CoV-2 assay. The positive panel consisted of RT-qPCR positive samples from patients with both <14 days and >14 days from the onset of clinical symptoms. The negative panel contained samples collected from the pre-pandemic era dengue patients and healthy donors during the pandemic. Moreover, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of FT-DBA were evaluated against RT-qPCR positive sera. However, the overall efficacies were assessed with sera that seroconverted against either nucleocapsid (NCP) or receptor-binding domain (RBD). RESULTS: In-house ELISA selected a total of 81 true seropositive and 100 seronegative samples. The sensitivity of samples with <14 days using FT-DBA was 94.7%, increasing to 100% for samples >14 days. The overall detection sensitivity and specificity were 98.8% and 98%, respectively, whereas the overall PPV and NPV were 99.6% and 99%. Moreover, comparative analysis between in-house ELISA assays and FT-DBA revealed clinical agreement of Cohen's Kappa value of 0.944. The FT-DBA showed sensitivity and specificity of 100% when compared with commercial CLIA kits. CONCLUSION: The assay can confirm past SARS-CoV-2 infection with high accuracy within 2 minutes compared to commercial CLIA or in-house ELISA. It can help track SARS-CoV-2 disease progression, population screening, and vaccination response. The ease of use of the assay without requiring any instruments while being semi-quantitative provides the avenue of its implementation in remote areas around the globe, where conventional serodiagnosis is not feasible.


Assuntos
Ouro/química , Immunoblotting/métodos , Imunoglobulina G/análise , Nanopartículas Metálicas/química , Nucleocapsídeo/análise , SARS-CoV-2/isolamento & purificação , Adulto , Anticorpos Antivirais/sangue , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Masculino , Valor Preditivo dos Testes , SARS-CoV-2/imunologia , Sensibilidade e Especificidade , Estudos Soroepidemiológicos
14.
PLoS One ; 16(2): e0246346, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33529223

RESUMO

BACKGROUND: In the ongoing pandemic situation of COVID-19, serological tests can complement the molecular diagnostic methods, and can be one of the important tools of sero-surveillance and vaccine evaluation. AIM: To develop and evaluate a rapid SARS-CoV-2 specific ELISA for detection of anti-SARS-CoV2 IgG from patients' biological samples. METHODS: In order to develop this ELISA, three panels of samples (n = 184) have been used: panel 1 (n = 19) and panel 2 (n = 60) were collected from RT-PCR positive patients within 14 and after 14 days of onset of clinical symptoms, respectively; whereas panel 3 consisted of negative samples (n = 105) collected either from healthy donors or pre-pandemic dengue patients. As a capturing agent full-length SARS-CoV2 specific recombinant nucleocapsid was immobilized. Commercial SARS-CoV2 IgG kit based on chemiluminescent assay was used for the selection of samples and optimization of the assay. The threshold cut-off point, inter-assay and intra-assay variations were determined. RESULTS: The incubation/reaction time was set at a total of 30 minutes with the sensitivity of 84% (95% confidence interval, CI, 60.4%, 96.6%) and 98% (95% CI, 91.1%, 100.0%), for panel 1 and 2, respectively; with overall 94.9% sensitivity (95% CI 87.5%, 98.6%). Moreover, the clinical specificity was 97.1% (95% CI, 91.9%, 99.4%) with no cross reaction with dengue samples. The overall positive and negative predictive values are 96.2% (95% CI 89.2%, 99.2%) and 96.2% (95% CI, 90.6% 99.0%), respectively. In-house ELISA demonstrated 100% positive and negative percent agreement with Elecsys Anti-SARS-CoV-2, with Cohen's kappa value of 1.00 (very strong agreement), while comparing 13 positive and 17 negative confirmed cases. CONCLUSION: The assay is rapid and can be applied as one of the early and retrospective sero-monitoring tools in all over the affected areas.


Assuntos
Anticorpos Antivirais/análise , Proteínas do Nucleocapsídeo de Coronavírus/análise , Ensaio de Imunoadsorção Enzimática/métodos , SARS-CoV-2/isolamento & purificação , COVID-19/diagnóstico , COVID-19/virologia , Ensaio de Imunoadsorção Enzimática/instrumentação , Humanos , Imunoglobulina G/análise , Fosfoproteínas/análise , Sensibilidade e Especificidade
15.
Vaccines (Basel) ; 9(12)2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34960133

RESUMO

COVID-19 vaccines are indispensable, with the number of cases and mortality still rising, and currently no medicines are routinely available for reducing morbidity and mortality, apart from dexamethasone, although others are being trialed and launched. To date, only a limited number of vaccines have been given emergency use authorization by the US Food and Drug Administration and the European Medicines Agency. There is a need to systematically review the existing vaccine candidates and investigate their safety, efficacy, immunogenicity, unwanted events, and limitations. The review was undertaken by searching online databases, i.e., Google Scholar, PubMed, and ScienceDirect, with finally 59 studies selected. Our findings showed several types of vaccine candidates with different strategies against SARS-CoV-2, including inactivated, mRNA-based, recombinant, and nanoparticle-based vaccines, are being developed and launched. We have compared these vaccines in terms of their efficacy, side effects, and seroconversion based on data reported in the literature. We found mRNA vaccines appeared to have better efficacy, and inactivated ones had fewer side effects and similar seroconversion in all types of vaccines. Overall, global variant surveillance and systematic tweaking of vaccines, coupled with the evaluation and administering vaccines with the same or different technology in successive doses along with homologous and heterologous prime-booster strategy, have become essential to impede the pandemic. Their effectiveness appreciably outweighs any concerns with any adverse events.

16.
Infect Drug Resist ; 14: 1049-1082, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33762831

RESUMO

Recent severe acute respiratory syndrome 2 (SARS-CoV-2) known as COVID-19, presents a deadly challenge to the global healthcare system of developing and developed countries, exposing the limitations of health facilities preparedness for emerging infectious disease pandemic. Opportune detection, confinement, and early treatment of infected cases present the first step in combating COVID-19. In this review, we elaborate on various COVID-19 diagnostic tools that are available or under investigation. Consequently, cell culture, followed by an indirect fluorescent antibody, is one of the most accurate methods for detecting SARS-CoV-2 infection. However, restrictions imposed by the regulatory authorities prevented its general use and implementation. Diagnosis via radiologic imaging and reverse transcriptase PCR assay is frequently employed, considered as standard procedures, whereas isothermal amplification methods are currently on the verge of clinical introduction. Notably, techniques such as CRISPR-Cas and microfluidics have added new dimensions to the SARS-CoV-2 diagnosis. Furthermore, commonly used immunoassays such as enzyme-linked immunosorbent assay (ELISA), lateral flow immunoassay (LFIA), neutralization assay, and the chemiluminescent assay can also be used for early detection and surveillance of SARS-CoV-2 infection. Finally, advancement in the next generation sequencing (NGS) and metagenomic analysis are smoothing the viral detection further in this global challenge.

17.
Microbiol Resour Announc ; 10(10)2021 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-33707329

RESUMO

Here, we report the coding-complete genome sequences of nine clinical severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants and their mutations. The samples were collected from nine Bangladeshi coronavirus disease 2019 (COVID-19) patients. We have identified the E484K escape mutation and the S359T mutation within the spike protein coding region of the sequenced genomes.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa