Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Acta Anaesthesiol Scand ; 63(4): 515-522, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30374950

RESUMO

BACKGROUND: Thoracic epidural analgesia (TEDA) was offered to patients with refractory angina pectoris. Our primary objectives were to evaluate TEDAs´ influence on quality of life (QoL, base for power analysis), and hypothesising that TEDA with bupivacaine during 1 month counteracts exercise-induced myocardial hypoperfusion and increase physical performance. METHODS: Patients with refractory angina and exercise inducible hypoperfusion, as demonstrated by myocardial perfusion imaging (MPI), were randomised to 1-month treatment with TEDA with bupivacaine (B-group, n = 9) or saline (P-group, n = 10) in a double-blind fashion. MPI and bicycle ergometry were performed before TEDA and after 1 month while subjective QoL on a visual analogue scale (VAS) reported by the patients was checked weekly. RESULTS: During this month VAS (mean [95%CI]) increased similarly in both groups (B-group from 33 [18-50] to 54 [30-78] P < 0.05; P-group from 40 [19-61] to 48 [25-70] P < 0.05). The B-group reduced their exertional-induced myocardial hypoperfusion (from 32% [12-52] to 21% [3-39]; n = 9; P < 0.05), while the P-group showed no significant change (before 21% [6-35]; at 1 month 23% [6-40]; n = 10). MPI at rest did not change and no improvement in physical performance was detected in neither of the groups. CONCLUSIONS: In refractory angina, TEDA with bupivacaine inhibits myocardial ischaemia in contrast to TEDA with saline. Regardless of whether bupivacaine or saline is applied intermittently every day, TEDA during 1 month improves the quality of life and reduces angina, even when physical performance remains low. A significant placebo effect has to be considered.


Assuntos
Analgesia Epidural/métodos , Angina Pectoris/complicações , Angina Pectoris/tratamento farmacológico , Exercício Físico , Isquemia Miocárdica/tratamento farmacológico , Isquemia Miocárdica/etiologia , Idoso , Idoso de 80 Anos ou mais , Anestésicos Locais/administração & dosagem , Anestésicos Locais/uso terapêutico , Angina Pectoris/psicologia , Bupivacaína/administração & dosagem , Bupivacaína/uso terapêutico , Método Duplo-Cego , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/psicologia , Medição da Dor , Imagem de Perfusão , Desempenho Psicomotor , Qualidade de Vida
2.
Acta Radiol ; 57(10): 1223-9, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26787677

RESUMO

BACKGROUND: Ultrasound speckle tracking offers a non-invasive way of studying strain in the free Achilles tendon where no anatomical landmarks are available for tracking. This provides new possibilities for studying injury mechanisms during sport activity and the effects of shoes, orthotic devices, and rehabilitation protocols on tendon biomechanics. PURPOSE: To investigate the feasibility of using a commercial ultrasound speckle tracking algorithm for assessing strain in tendon tissue. MATERIAL AND METHODS: A polyvinyl alcohol (PVA) phantom, three porcine tendons, and a human Achilles tendon were mounted in a materials testing machine and loaded to 4% peak strain. Ultrasound long-axis cine-loops of the samples were recorded. Speckle tracking analysis of axial strain was performed using a commercial speckle tracking software. Estimated strain was then compared to reference strain known from the materials testing machine. Two frame rates and two region of interest (ROI) sizes were evaluated. RESULTS: Best agreement between estimated strain and reference strain was found in the PVA phantom (absolute error in peak strain: 0.21 ± 0.08%). The absolute error in peak strain varied between 0.72 ± 0.65% and 10.64 ± 3.40% in the different tendon samples. Strain determined with a frame rate of 39.4 Hz had lower errors than 78.6 Hz as was the case with a 22 mm compared to an 11 mm ROI. CONCLUSION: Errors in peak strain estimation showed high variability between tendon samples and were large in relation to strain levels previously described in the Achilles tendon.


Assuntos
Tendão do Calcâneo/diagnóstico por imagem , Tendão do Calcâneo/fisiologia , Ultrassonografia/métodos , Algoritmos , Animais , Fenômenos Biomecânicos , Desenho de Equipamento , Humanos , Técnicas In Vitro , Imagens de Fantasmas , Software , Suínos
3.
J Ultrasound Med ; 34(9): 1599-605, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26254153

RESUMO

OBJECTIVES: Quantification of myocardial perfusion by contrast echocardiography remains a challenge. Existing imaging phantoms used to evaluate the performance of ultrasound scanners do not comply with perfusion basics in the myocardium, where perfusion and motion are inherently coupled. To contribute toward an improvement, we developed a contrast echocardiographic perfusion imaging platform based on an isolated rat heart coupled to an ultrasound scanner. METHODS: Perfusion was assessed by using 3 different types of contrast agents: dextran-based Promiten (Meda AB, Solna, Sweden), phospholipid-shelled SonoVue (Bracco Diagnostics, Inc, Princeton, NJ), and polymer-shelled MB-pH5-RT, developed in-house. The myocardial video intensity was monitored over time from contrast agent administration to peak, and 2 characteristic constants were calculated by using an exponential fit: A, representing capillary volume; and ß, representing inflow velocity. RESULTS: Acquired experimental evidence demonstrates that the application of all 3 contrast agents allows sonographic estimation of myocardial perfusion in the isolated rat heart. Video intensity maps show that an increase in contrast concentration increases the late-plateau values, A, mimicking increased capillary volume. Estimated values of the flow, proportional to A × ß, increase when the pressure of the perfusate column increases from 80 to 110 cm of water. This finding is in agreement with the true values of the coronary flow increase measured by a flowmeter attached to the aortic cannula. CONCLUSIONS: The contrast echocardiographic perfusion imaging platform described holds promise for standardized evaluation and optimization of contrast perfusion ultrasound imaging in which real-time inflow curves at low acoustic power semiquantitatively reflect coronary flow.


Assuntos
Meios de Contraste , Dextranos , Ecocardiografia/instrumentação , Preparação de Coração Isolado/instrumentação , Imagem de Perfusão do Miocárdio/instrumentação , Fosfolipídeos , Hexafluoreto de Enxofre , Animais , Ecocardiografia/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Preparação de Coração Isolado/métodos , Masculino , Imagem de Perfusão do Miocárdio/métodos , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
BMC Med Imaging ; 14: 20, 2014 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-24889837

RESUMO

BACKGROUND: Studies of prenatal detection of congenital heart disease (CHD) in the UK, Italy, and Norway indicate that it should be possible to improve the prenatal detection rate of CHD in Sweden. These studies have shown that training programs, visualization of the outflow tracts and color-Doppler all can help to speed up and improve the detection rate and accuracy. We aimed to introduce a more accurate standardized fetal cardiac ultrasound screening protocol in Sweden. METHODS: A novel pedagogical model for training midwives in standardized cardiac imaging was developed, a model using a think-aloud analysis during a pre- and post-course test and a subsequent group reflection. The self-estimated difficulties and knowledge gaps of two experienced and two beginner midwives were identified. A two-day course with mixed lectures, demonstrations and hands-on sessions was followed by a feedback session three months later consisting of an interview and check-up. The long-term effects were tested two years later. RESULTS: At the post-course test the self-assessed uncertainty was lower than at the pre-course test. The qualitative evaluation showed that the color Doppler images were difficult to interpret, but the training seems to have improved their ability to use the new technique. The ability to perform the method remained at the new level at follow-up both three months and two years later. CONCLUSIONS: Our results indicate that by implementing new imaging modalities and providing hands-on training, uncertainty can be reduced and examination time decreased, but they also show that continuous on-site training with clinical and technical back-up is important.


Assuntos
Educação/normas , Coração Fetal/anatomia & histologia , Cardiopatias Congênitas/embriologia , Tocologia/educação , Ultrassonografia Doppler/métodos , Diagnóstico por Imagem , Embrião de Mamíferos , Feminino , Coração Fetal/anormalidades , Cardiopatias Congênitas/diagnóstico , Humanos , Noruega , Gravidez , Segundo Trimestre da Gravidez
5.
Clin Physiol Funct Imaging ; 44(4): 340-348, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38576112

RESUMO

BACKGROUND: Computed tomography (CT) offers pulmonary volumetric quantification but is not commonly used in healthy individuals due to radiation concerns. Chronic airflow limitation (CAL) is one of the diagnostic criteria for chronic obstructive pulmonary disease (COPD), where early diagnosis is important. Our aim was to present reference values for chest CT volumetric and radiodensity measurements and explore their potential in detecting early signs of CAL. METHODS: From the population-based Swedish CArdioPulmonarybioImage Study (SCAPIS), 294 participants aged 50-64, were categorized into non-CAL (n = 258) and CAL (n = 36) groups based on spirometry. From inspiratory and expiratory CT images we compared lung volumes, mean lung density (MLD), percentage of low attenuation volume (LAV%) and LAV cluster volume between groups, and against reference values from static pulmonary function test (PFT). RESULTS: The CAL group exhibited larger lung volumes, higher LAV%, increased LAV cluster volume and lower MLD compared to the non-CAL group. Lung volumes significantly deviated from PFT values. Expiratory measurements yielded more reliable results for identifying CAL compared to inspiratory. Using a cut-off value of 0.6 for expiratory LAV%, we achieved sensitivity, specificity and positive/negative predictive values of 72%, 85% and 40%/96%, respectively. CONCLUSION: We present volumetric reference values from inspiratory and expiratory chest CT images for a middle-aged healthy cohort. These results are not directly comparable to those from PFTs. Measures of MLD and LAV can be valuable in the evaluation of suspected CAL. Further validation and refinement are necessary to demonstrate its potential as a decision support tool for early detection of COPD.


Assuntos
Medidas de Volume Pulmonar , Pulmão , Valor Preditivo dos Testes , Doença Pulmonar Obstrutiva Crônica , Espirometria , Humanos , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Masculino , Feminino , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Medidas de Volume Pulmonar/métodos , Reprodutibilidade dos Testes , Suécia , Tomografia Computadorizada por Raios X/métodos , Volume Expiratório Forçado , Diagnóstico Precoce
6.
Biomed Eng Online ; 12: 69, 2013 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-23842033

RESUMO

BACKGROUND: Computer technology enables realistic simulation of cardiovascular physiology. The increasing number of clinical surgical and medical treatment options imposes a need for better understanding of patient-specific pathology and outcome prediction. METHODS: A distributed lumped parameter real-time closed-loop model with 26 vascular segments, cardiac modelling with time-varying elastance functions and gradually opening and closing valves, the pericardium, intrathoracic pressure, the atrial and ventricular septum, various pathological states and including oxygen transport has been developed. RESULTS: Model output is pressure, volume, flow and oxygen saturation from every cardiac and vascular compartment. The model produces relevant clinical output and validation of quantitative data in normal physiology and qualitative directions in simulation of pathological states show good agreement with published data. CONCLUSION: The results show that it is possible to build a clinically relevant real-time computer simulation model of the normal adult cardiovascular system. It is suggested that understanding qualitative interaction between physiological parameters in health and disease may be improved by using the model, although further model development and validation is needed for quantitative patient-specific outcome prediction.


Assuntos
Coração/fisiologia , Hemodinâmica , Modelos Biológicos , Oxigênio/metabolismo , Adulto , Insuficiência da Valva Aórtica/metabolismo , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/metabolismo , Estenose da Valva Aórtica/fisiopatologia , Arteriosclerose/metabolismo , Arteriosclerose/fisiopatologia , Transporte Biológico , Exercício Físico/fisiologia , Coração/fisiopatologia , Insuficiência Cardíaca/metabolismo , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Fatores de Tempo , Manobra de Valsalva/fisiologia
7.
J Cardiothorac Vasc Anesth ; 26(5): 822-8, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22480635

RESUMO

OBJECTIVES: In patients with refractory angina, the adjuvant effects of long-term home self-treatment with thoracic epidural analgesia on angina, quality of life, and safety were evaluated. DESIGN: A prospective, consecutive study. SETTING: A university hospital. PARTICIPANTS AND INTERVENTION: Between January 1998 and August 2007, 152 consecutive patients with refractory angina began treatment with thoracic epidural analgesia by intermittent injections of bupivacaine (139 home treatment and 13 palliative). Data were collected until August 2008; therefore, the follow-up for each patient was between 1 and 9 years. MEASUREMENTS AND MAIN RESULTS: All but 7 of the patients improved symptomatically, and the improvement was maintained throughout the period of treatment (median = 19 months; range, 1 month-8.9 years). After 1 to 2 weeks, the median (interquartile range [IQR]) Canadian Cardiovascular Society angina class decreased from 4.0 (3.0-4.0) to 2.0 (1.0-2.0), the mean ± standard deviation frequency of anginal attacks decreased from 36 ± 19 to 4.4 ± 6.8 a week, the nitroglycerin intake decreased from 27.7 ± 15.7 to 2.7 ± 4.9 a week, and the median (IQR) overall self-rated quality of life assessed by the visual analog scale increased from 25 (20-30) to 70 (50-75) (all p < 0.001). About one-third of the patients had a dislodgement of the epidural catheter. Apart from 1 epidural hematoma that appeared in 1 patient with a previously undiagnosed bleeding defect, no other serious catheter-related complications occurred. CONCLUSIONS: Long-term self-administered home treatment with thoracic epidural analgesia is a safe, widely available adjuvant treatment for patients with severe refractory angina. It produces symptomatic relief of angina and improves quality of life. The technical development of the method to protect the catheter against dislodgement is needed.


Assuntos
Analgesia Epidural/métodos , Analgesia Controlada pelo Paciente/métodos , Angina Pectoris/tratamento farmacológico , Medição da Dor/métodos , Idoso , Idoso de 80 Anos ou mais , Angina Pectoris/epidemiologia , Angina Pectoris/psicologia , Bupivacaína/administração & dosagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor/efeitos dos fármacos , Estudos Prospectivos , Qualidade de Vida/psicologia , Autoadministração , Vértebras Torácicas , Fatores de Tempo , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 77(2): 272-5, 2011 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-20824753

RESUMO

OBJECTIVES: We have developed a method using transthoracic echocardiography in establishing optimal visualization of the aortic root, to reduce the amount of contrast medium used in each patient. BACKGROUND: During transcatheter aortic valve implantation, it is necessary to obtain an optimal fluoroscopic projection for deployment of the valve showing the aortic ostium with the three cusps aligned in the beam direction. This may require repeat aortic root angiograms at this stage of the procedure with a high amount of contrast medium with a risk of detrimental influence on renal function. METHODS: We studied the conventional way and an echo guided way to optimize visualisation of the aortic root. Echocardiography was used initially allowing easier alignment of the image intensifier with the transducer's direction. RESULTS: Contrast volumes, radiation/fluoroscopy exposure times, and postoperative creatinine levels were significantly less in patients having the echo-guided orientation of the optimal fluoroscopic angles compared with patients treated with the conventional approach. CONCLUSION: We present a user-friendly echo-guided method to facilitate fluoroscopy adjustment during transcatheter aortic valve implantation. In our series, the amounts of contrast medium and radiation have been significantly reduced, with a concomitant reduction in detrimental effects on renal function in the early postoperative phase.


Assuntos
Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco , Meios de Contraste , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/terapia , Implante de Prótese de Valva Cardíaca/métodos , Radiografia Intervencionista , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Cateterismo Cardíaco/instrumentação , Meios de Contraste/efeitos adversos , Creatinina/sangue , Feminino , Fluoroscopia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Nefropatias/sangue , Nefropatias/induzido quimicamente , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista/efeitos adversos , Medição de Risco , Resultado do Tratamento , Ultrassonografia
9.
J Trauma ; 66(2): 329-36, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19204504

RESUMO

BACKGROUND: The Parkland formula (2-4 mL/kg/burned area of total body surface area %) with urine output and mean arterial pressure (MAP) as endpoints for the fluid resuscitation in burns is recommended all over the world. There has recently been a discussion on whether central circulatory endpoints should be used instead, and also whether volumes of fluid should be larger. Despite this, there are few central hemodynamic data available in the literature about the results when the formula is used correctly. METHODS: Ten burned patients, admitted to our unit early, and with a burned area of >20% of total body surface area were investigated at 12, 24, and 36 hours after injury. Using transesophageal echocardiography, pulmonary artery catheterization, and transpulmonary thermodilution to monitor them, we evaluated the cardiovascular coupling when urinary output and MAP were used as endpoints. RESULTS: Oxygen transport variables, heart rate, MAP, and left ventricular fractional area, did not change significantly during fluid resuscitation. Left ventricular end-systolic and end-diastolic area and global end-diastolic volume index increased from subnormal values at 12 hours to normal ranges at 24 hours after the burn. Extravascular lung water: intrathoracal blood volume ratio was increased 12 hours after the burn. CONCLUSIONS: Preload variables, global systolic function, and oxygen transport recorded simultaneously by three separate methods showed no need to increase the total fluid volume within 36 hours of a major burn. Early (12 hours) signs of central circulatory hypovolemia, however, support more rapid infusion of fluid at the beginning of treatment.


Assuntos
Queimaduras/fisiopatologia , Queimaduras/terapia , Hidratação/métodos , Ressuscitação/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Superfície Corporal , Cateterismo de Swan-Ganz , Ecocardiografia Transesofagiana , Feminino , Hemodinâmica , Humanos , Ventilação com Pressão Positiva Intermitente , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio , Termodiluição
10.
Nutr Metab (Lond) ; 15: 45, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29951109

RESUMO

BACKGROUND: Physical activity is associated with health in women. Published MET-values (MET: metabolic equivalent of task) may assess physical activity and energy expenditure but tend to be too low for subjects with a high total body fat (TBF) content and therefore inappropriate for many contemporary women. The MET-value for an activity is the energy expenditure of a subject performing this activity divided by his/her resting energy expenditure, often assumed to be 4.2 kJ/kg/h. Relationships between TBF and MET have been little studied although overweight and obesity is common in women. Available data indicate that MET-values decrease during pregnancy but more studies in pregnant contemporary women are needed. SUBJECTS AND METHODS: Using indirect calorimetry we measured energy expenditure and assessed MET-values in women, 22 non-pregnant (BMI: 18-34) and 22 in gestational week 32 (non-pregnant BMI: 18-32) when resting, sitting, cycling (30 and 60 watts), walking (3.2 and 5.6 km/h) and running (8 km/h). Relationships between TBF and MET-values were investigated and used to predict modified MET-values. The potential of such values to improve calculations of total energy expenditure of women was investigated. RESULTS: The resting energy expenditure was below 4.2 kJ/kg/h in both groups of women. Women in gestational week 32 had a higher resting energy metabolism (p < 0.001) and 7-15% lower MET-values (p < 0.05) than non-pregnant women. MET-values of all activities were correlated with TBF (p < 0.05) in non-pregnant women and modified MET-values improved estimates of total energy expenditure in such women. In pregnant women, correlations (p ≤ 0.03) between TBF and MET were found for running (8 km/h) and for walking at 5.6 km/h. CONCLUSIONS: Our results are relevant when attempts are made to modify the MET-system in contemporary pregnant and non-pregnant women. MET-values were decreased in gestational week 32, mainly due to an increased resting energy metabolism and studies describing how body composition affects the one MET-value (i.e. the resting energy metabolism in kJ/kg/h) during pregnancy are warranted. Studies of how pregnancy and TBF affect MET-values of high intensity activities are also needed. Corrections based on TBF may have a potential to improve the MET-system in non-pregnant women.

11.
Ultrasonics ; 70: 275-83, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27261567

RESUMO

The objective of this paper is to explore the trajectory motion of microsize (typically smaller than a red blood cell) encapsulated polymer-shelled gas bubbles propelled by radiation force in an acoustic standing-wave field and to compare the corresponding movements of solid polymer microbeads. The experimental setup consists of a microfluidic chip coupled to a piezoelectric crystal (PZT) with a resonance frequency of about 2.8MHz. The microfluidic channel consists of a rectangular chamber with a width, w, corresponding to one wavelength of the ultrasound standing wave. It creates one full wave ultrasound of a standing-wave pattern with two pressure nodes at w/4 and 3w/4 and three antinodes at 0, w/2, and w. The peak-to-peak amplitude of the electrical potential over the PZT was varied between 1 and 10V. The study is limited to no-flow condition. From Gor'kov's potential equation, the acoustic contrast factor, Φ, for the polymer-shelled microbubbles was calculated to about -60.7. Experimental results demonstrate that the polymer-shelled microbubbles are translated and accumulated at the pressure antinode planes. This trajectory motion of polymer-shelled microbubbles toward the pressure antinode plane is similar to what has been described for other acoustic contrast particles with a negative Φ. First, primary radiation forces dragged the polymer-shelled microbubbles into proximity with each other at the pressure antinode planes. Then, primary and secondary radiation forces caused them to quickly aggregate at different spots along the channel. The relocation time for polymer-shelled microbubbles was 40 times shorter than that for polymer microbeads, and in contrast to polymer microbeads, the polymer-shelled microbubbles were actuated even at driving voltages (proportional to radiation forces) as low as 1V. In short, the polymer-shelled microbubbles demonstrate the behavior attributed to the negative acoustic contrast factor particles and thus can be trapped at the antinode plane and thereby separated from particles having a positive acoustic contrast factor, such as for example solid particles and cells. This phenomenon could be utilized in exploring future applications, such as bioassay, bioaffinity, and cell interaction studies in vitro in a well-controlled environment.


Assuntos
Eletroforese/métodos , Microbolhas , Modelos Químicos , Polímeros/química , Polímeros/efeitos da radiação , Som , Simulação por Computador , Teste de Materiais , Movimento (Física) , Doses de Radiação
12.
Am J Clin Nutr ; 81(3): 678-85, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15755839

RESUMO

BACKGROUND: The total energy cost of pregnancy is largely due to an elevated basal metabolic rate (BMR). Large variations in the BMR response to pregnancy have been reported, but the factors associated with this variability are incompletely known. OBJECTIVE: The objective was to identify factors associated with variability in the BMR response to pregnancy. DESIGN: In 22 healthy women, BMR, body weight (BW), total body fat (TBF), fat-free mass (FFM), circulatory variables, serum concentrations of insulin-like growth factor I (IGF-I), and thyroid hormones were measured before pregnancy and in gestational weeks 14 and 32. BMR and BW were also measured in gestational weeks 8, 20, and 35. Fetal weight was estimated in gestational week 31. RESULTS: In gestational week 14, the increase in BMR correlated significantly with the corresponding increase in BW and with the prepregnancy percentage of TBF. Together these variables explained approximately 40% of the variability in the BMR response. In gestational week 32, the increase in BMR correlated significantly with the corresponding changes in BW, TBF, FFM, IGF-I, cardiac output, and free triiodothyronine. The increase in BW in combination with fetal weight or with the elevated concentration of IGF-I in serum explained approximately 60% of the variability in the increase in BMR. CONCLUSIONS: Weight gain and the prepregnancy percentage of TBF-ie, factors related to the maternal nutritional situation-are important factors with regard to the variability in the BMR response to pregnancy. Thus, it is important to consider the nutritional situation before and during gestation when assessing pregnancy energy requirements.


Assuntos
Metabolismo Basal/fisiologia , Composição Corporal/fisiologia , Desenvolvimento Fetal/fisiologia , Gravidez/metabolismo , Tecido Adiposo/metabolismo , Adulto , Peso ao Nascer/fisiologia , Peso Corporal/fisiologia , Débito Cardíaco , Deutério , Metabolismo Energético/fisiologia , Feminino , Frequência Cardíaca , Humanos , Recém-Nascido , Fator de Crescimento Insulin-Like I/metabolismo , Necessidades Nutricionais , Gravidez/sangue , Gravidez/fisiologia , Hormônios Tireóideos/metabolismo
13.
Drug Des Devel Ther ; 9: 2409-19, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25995614

RESUMO

The current study describes novel multifunctional polymer-shelled microbubbles (MBs) loaded with nitric oxide (NO) for integrated therapeutic and diagnostic applications (ie, theranostics) of myocardial ischemia. We used gas-filled MBs with an average diameter of 4 µm stabilized by a biocompatible shell of polyvinyl alcohol. In vitro acoustic tests showed sufficient enhancement of the backscattered power (20 dB) acquired from the MBs' suspension. The values of attenuation coefficient (0.8 dB/cm MHz) and phase velocities (1,517 m/s) were comparable with those reported for the soft tissue. Moreover, polymer MBs demonstrate increased stability compared with clinically approved contrast agents with a fracture threshold of about 900 kPa. In vitro chemiluminescence measurements demonstrated that dry powder of NO-loaded MBs releases its gas content in about 2 hours following an exponential decay profile with an exponential time constant equal to 36 minutes. The application of high-power ultrasound pulse (mechanical index =1.2) on the MBs resuspended in saline decreases the exponential time constant from 55 to 4 minutes in air-saturated solution and from 17 to 10 minutes in degassed solution. Thus, ultrasound-triggered release of NO is achieved. Cytotoxicity tests indicate that phagocytosis of the MBs by macrophages starts within 6-8 hours. This is a suitable time for initial diagnostics, treatment, and monitoring of the therapeutic effect using a single injection of the proposed multifunctional MBs.


Assuntos
Meios de Contraste/química , Óxido Nítrico/farmacologia , Nanomedicina Teranóstica , Ultrassom/métodos , Química Farmacêutica , Meios de Contraste/efeitos adversos , Equipamentos e Provisões , Gases , Humanos , Técnicas In Vitro , Macrófagos/efeitos dos fármacos , Microbolhas , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/tratamento farmacológico , Óxido Nítrico/química , Tamanho da Partícula , Fagocitose , Pós
14.
Artigo em Inglês | MEDLINE | ID: mdl-25768814

RESUMO

This work describes the fracturing mechanism of air-filled microbubbles (MBs) encapsulated by a cross-linked poly(vinyl alcohol) (PVA) shell. The radial oscillation and fracturing events following the ultrasound exposure were visualized with an ultrahigh-speed camera, and backscattered timedomain signals were acquired with the acoustic setup specific for harmonic detection. No evidence of gas emerging from defects in the shell with the arrival of the first insonation burst was found. In optical recordings, more than one shell defect was noted, and the gas core was drained without any sign of air extrusion when several consecutive bursts of 1 MPa amplitude were applied. In acoustic tests, the backscattered peak-to-peak voltage gradually reached its maximum and exponentially decreased when the PVA-based MB suspension was exposed to approximately 20 consecutive bursts arriving at pulse repetition frequencies of 100 and 500 Hz. Taking into account that the PVA shell is porous and possibly contains large air pockets between the cross-linked PVA chains, the aforementioned acoustic behavior might be attributed to pumping gas from these pockets in combination with gas release from the core through shell defects. We refer to this fracturing mechanism as pumping-out behavior, and this behavior could have potential use for the local delivery of therapeutic gases, such as nitric oxide.


Assuntos
Meios de Contraste/química , Microbolhas , Álcool de Polivinil/química , Acústica , Teste de Materiais , Óptica e Fotônica
15.
Echocardiography ; 15(8 Pt 1): 731-740, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11175105

RESUMO

The aim of this study was to evaluate a second-generation echo contrast agent (NC100100) for the study of myocardial perfusion. In eight anesthetized open-chest dogs, this agent was injected intravenously under baseline conditions, during acute coronary thrombosis, and after reperfusion, using both fundamental (FI) and harmonic (HI) imaging, both continuous and intermittent imaging, and both ultrasound (US) and integrated backscatter (IBS) imaging. Contrast injections did not modify the hemodynamic parameters. With all imaging modalities, myocardial contrast enhancement (MCE) was higher with intermittent than with continuous imaging (134 vs 82 gray level/pixel using FI, P = 0.02; 62 vs 32 acoustic units using US HI, P = 0.02; and 52 vs 12 dB using IBS, P = 0.05). MCE equally increased using either US or IBS imaging. The accuracy of MCE in detecting perfusion defects during coronary occlusion and myocardial reperfusion after thrombolysis was very good (sensitivity and specificity = 93% and 95% and 89% and 93%, respectively). The extent of myocardial perfusion defects by echo contrast showed a closer correlation with microspheres using HI (r = 0.82) than FI (r = 0.53). Thus, the intravenous administration of NC100100 during intermittent HI allows myocardial perfusion abnormalities to be accurately detected during acute myocardial infarction.

16.
Ultrasonics ; 42(1-9): 301-7, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15047302

RESUMO

The propagation of diagnostic ultrasonic imaging pulses in tissue and their interaction with contrast micro bubbles is a very complex physical process, which we assumed to be separable into three stages: pulse propagation in tissue, the interaction of the pulse with the contrast bubble, and the propagation of the scattered echo. The model driven approach is used to gain better knowledge of the complex processes involved. A simplified way of field simulation is chosen due to the complexity of the task and the necessity to estimate comparative contributions of each component of the process. Simulations are targeted at myocardial perfusion estimation. A modified method for spatial superposition of attenuated waves enables simulations of low intensity pulse pressure fields from weakly focused transducers in a nonlinear, attenuating, and liquid-like biological medium. These assumptions enable the use of quasi-linear calculations of the acoustic field. The simulations of acoustic bubble response are carried out with the Rayleigh-Plesset equation with the addition of radiation damping. Theoretical simulations with synthesised and experimentally sampled pulses show that the interaction of the excitation pulses with the contrast bubbles is the main cause of nonlinear scattering, and a 2-3 dB increase of second harmonic amplitude depends on nonlinear distortions of the incident pulse.


Assuntos
Meios de Contraste , Ecocardiografia , Microesferas , Modelos Teóricos , Processamento de Sinais Assistido por Computador , Transdutores
18.
ASAIO J ; 56(5): 417-21, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20613488

RESUMO

Implantable mechanical left ventricular assist devices (LVADs) are used as a bridge or alternative to heart transplantation. Peroperative transesophageal echocardiography is commonly applied during implantation. Significant air embolism may occur as a result of air leakage at connections and anastomoses when LV filling becomes inadequate, and this must be prevented. Early suspicion and detection of air is mandatory to avoid negative circulatory effects. We hypothesized that monitoring of heart chamber size and occurrence of single air bubbles using second harmonic imaging (SHI) echocardiography may prevent risk for significant air embolism. After implantation of the LVAD in 10 calves, invasive hemodynamic monitoring and epicardial SHI were performed while increasing pump speed. Air bubbles in the ascending aorta were monitored and the left heart visualized for off-line dimensional analysis. Detection of air bubbles in the ascending aorta preceded their appearance in the left ventricle. They occurred exclusively but not always after a decrease in left atrial (LA) size. Decrease in LA pressure did not predict bubble detection or reduction in LA size. We conclude that SHI detects spontaneous ultrasound contrast during implantation of a LVAD and that a decrease in LA size is a warning that air embolism is imminent.


Assuntos
Ecocardiografia/métodos , Embolia Aérea/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Coração Auxiliar/efeitos adversos , Animais , Procedimentos Cirúrgicos Cardiovasculares/efeitos adversos , Bovinos , Embolia Aérea/prevenção & controle , Aumento da Imagem/métodos
20.
Ultrasound Med Biol ; 35(3): 447-57, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19152997

RESUMO

Quantitative assessment of regional myocardial function at rest and during stress with Doppler tissue imaging (DTI) plays an important role in daily routine echocardiography. However, reliable visual analysis is largely dependent on image quality and adequate border delineation, which still remains a challenge in a significant number of patients. In this respect, an ultrasound contrast agent (UCA) is often used to improve visualization in patients with suboptimal image quality. The knowledge of how DTI measurements will be affected by UCA present in the tissue is therefore of significant importance for an accurate interpretation of local myocardial motion. The aim of this paper was to investigate how signal contribution from UCA and nonlinear wave propagation influence the performance of the autocorrelation phase shift estimator used for DTI applications. Our results are based on model experiments with a clinical 2-D grayscale scanner and computational simulations of the DTI velocity estimator for synthetically-derived pulses, simulated bubble echoes and experimentally-sampled RF data of transmitted pulses and backscattered contrast echoes. The results show that destruction of UCA present in the tissue will give rise to an apparent bidirectional velocity bias of individual velocity estimates, but that spatial averaging of individual velocity measurements within a region-of-interest will result in a negative bias (away from the transducer) of the estimated mean or mean peak velocity. The UCA destruction will also have a significant impact on the measured integrated mean velocity over time, i.e., displacement. To achieve improved visualization with UCA during DTI-examinations, we either recommend that it is performed at low acoustic powers, mechanical index

Assuntos
Meios de Contraste , Ecocardiografia Doppler/métodos , Ecocardiografia sob Estresse/métodos , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Compostos Férricos , Coração/fisiologia , Humanos , Ferro , Microbolhas , Modelos Cardiovasculares , Óxidos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa