Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Vasc Interv Radiol ; 33(6): 695-701, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35311666

RESUMO

PURPOSE: To assess the utility of the radius, exophytic/endophytic, nearness to collecting system or sinus, anterior/posterior, and location relative to polar lines (RENAL) nephrometry scoring system at predicting adverse events and outcomes in percutaneous microwave ablation (MWA) of renal tumors. MATERIALS AND METHODS: A retrospective review of 116 patients who underwent MWA from 2004 to 2018 at 2 large university hospitals was conducted. Patient demographics and tumor characteristics were collected. The RENAL nephrometry scores were calculated, and procedure-related adverse events were stratified into minor and major (the Society of Interventional Radiology classification of class C or higher). Technical and oncologic outcomes were based on follow-up magnetic resonance imaging and computed tomography scans after ablation. RESULTS: The mean RENAL score was 6.6 (range, 4-11), and the mean tumor size was 24 mm. Follow-up ranged between 16 and 161 weeks (median, 50 weeks; mean, 65 weeks). Oncologic control was achieved in 96% (n = 111) of patients. The major and minor adverse event rates were 8.6% (n = 10) and 17% (n = 19), respectively. The mean RENAL score for patients with recurrent and/or residual tumor (8.2 ± 2.7) was higher than that for patients without disease recurrence (6.5 ± 3.5, P = .05). However, in a multivariate analysis, the RENAL score was not found to be an independent predictor of oncologic outcomes (odds ratio, 1.548; P = .092). CONCLUSIONS: The RENAL nephrometry score has minimal utility for predicting outcomes and adverse events in MWA of renal tumors. The inconsistent nature of RENAL nephrometry scoring in percutaneous ablation procedures underscores the need for an ablation-specific risk stratification system.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Carcinoma de Células Renais/cirurgia , Humanos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/etiologia , Neoplasias Renais/cirurgia , Micro-Ondas/efeitos adversos , Recidiva Local de Neoplasia/cirurgia , Nefrectomia/efeitos adversos , Estudos Retrospectivos
2.
Sci Rep ; 13(1): 16130, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37752177

RESUMO

Percutaneous drains have provided a minimally invasive way to treat a wide range of disorders from abscess drainage to enteral feeding solutions to treating hydronephrosis. These drains suffer from a high rate of dislodgement of up to 30% resulting in emergency room visits, repeat hospitalizations, and catheter repositioning/replacement procedures, which incur significant morbidity and mortality. Using ex vivo and in vivo models, a force body diagram was utilized to determine the forces experienced by a drainage catheter during dislodgement events, and the individual components which contribute to drainage catheter securement were empirically collected. Prototypes of a skin level catheter securement and valved quick release system were then developed. The system was inspired by capstans used in boating for increasing friction of a line around a central spool and quick release mechanisms used in electronics such as the Apple MagSafe computer charger. The device was tested in a porcine suprapubic model, which demonstrated the effectiveness of the device to prevent drain dislodgement. The prototype demonstrated that the miniaturized versions of technologies used in boating and electronics industries were able to meet the needs of preventing dislodgement of patient drainage catheters.


Assuntos
Catéteres , Remoção de Dispositivo , Humanos , Animais , Suínos , Drenagem , Fontes de Energia Elétrica , Eletrônica
3.
J Med Screen ; 28(2): 210-212, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33663240

RESUMO

The COVID-19 pandemic has led to delays in cancer diagnosis, in part due to postponement of cancer screening. We used Google Trends data to assess public attention to cancer screening during the first peak of the COVID-19 pandemic. Search volume for terms related to established cancer screening tests ("colonoscopy," "mammogram," "lung cancer screening," and "pap smear") showed a marked decrease of up to 76% compared to the pre-pandemic period, a significantly greater drop than for search volume for terms denoting common chronic diseases. Maintaining awareness of cancer screening during future public health crises may decrease delays in cancer diagnosis.


Assuntos
COVID-19 , Detecção Precoce de Câncer , Comportamento de Busca de Informação , Armazenamento e Recuperação da Informação/tendências , Ferramenta de Busca/tendências , Neoplasias da Mama/diagnóstico por imagem , Colonoscopia/tendências , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico , Masculino , Mamografia/tendências , Ferramenta de Busca/estatística & dados numéricos , Esfregaço Vaginal/tendências
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa