Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
J Clin Microbiol ; 60(9): e0021722, 2022 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-35969171

RESUMO

The Bruker Biotyper matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS) platform was assessed on its ability to accurately identify 314 nontuberculous mycobacteria (NTM) representing 73 species. All NTM isolates, representing 183 rapidly growing and 131 slowly growing organisms, were previously identified by Sanger DNA sequencing of the full-length 16S rRNA gene, and region V of the rpoB gene. An optimized version of the Bruker bead-beating procedure for protein extraction of NTM isolates was used to ensure high quality spectra for all NTM isolates, including less frequently encountered species. NTM spectra were analyzed using Bruker's research use only, Mycobacteria Library v6.0, supplemented by the MicrobeNet database. Identification of NTM by MALDI-TOF had an accuracy of 94% (296/314). The identification accuracy for rapidly growing mycobacteria was higher at 99% (182/183) than it was for slowly growing mycobacteria at 87% (114/131). While MALDI-TOF performed well against Sanger sequencing of the 16S rRNA gene alone, there were 11 species that required additional sequencing of rpoB. Most discrepancies between MALDI-TOF and sequencing results are likely due to underrepresentation of some species in the libraries used. Overall, the results of this study support Bruker's MALDI-TOF platform as an accurate and reliable method for the identification of NTM.


Assuntos
Infecções por Mycobacterium não Tuberculosas , Micobactérias não Tuberculosas , Humanos , Infecções por Mycobacterium não Tuberculosas/diagnóstico , Infecções por Mycobacterium não Tuberculosas/microbiologia , RNA Ribossômico 16S/genética , Análise de Sequência de DNA , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
2.
Emerg Infect Dis ; 22(8): 1340-1347, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27434822

RESUMO

During 2013, the Maryland Department of Health and Mental Hygiene in Baltimore, MD, USA, received report of 2 Maryland residents whose surgical sites were infected with rapidly growing mycobacteria after cosmetic procedures at a clinic (clinic A) in the Dominican Republic. A multistate investigation was initiated; a probable case was defined as a surgical site infection unresponsive to therapy in a patient who had undergone cosmetic surgery in the Dominican Republic. We identified 21 case-patients in 6 states who had surgery in 1 of 5 Dominican Republic clinics; 13 (62%) had surgery at clinic A. Isolates from 12 (92%) of those patients were culture-positive for Mycobacterium abscessus complex. Of 9 clinic A case-patients with available data, all required therapeutic surgical intervention, 8 (92%) were hospitalized, and 7 (78%) required ≥3 months of antibacterial drug therapy. Healthcare providers should consider infection with rapidly growing mycobacteria in patients who have surgical site infections unresponsive to standard treatment.


Assuntos
Turismo Médico , Infecções por Mycobacterium não Tuberculosas/epidemiologia , Infecções por Mycobacterium não Tuberculosas/microbiologia , Mycobacterium abscessus , Adolescente , Adulto , Surtos de Doenças , República Dominicana/epidemiologia , Feminino , Humanos , Pessoa de Meia-Idade , Infecções por Mycobacterium não Tuberculosas/tratamento farmacológico , Infecções por Mycobacterium não Tuberculosas/economia , Cirurgia Plástica/efeitos adversos , Infecção da Ferida Cirúrgica , Estados Unidos/epidemiologia , Adulto Jovem
3.
Clin Infect Dis ; 59(1): 1-8, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24729502

RESUMO

BACKGROUND: Compounding pharmacies often prepare parenteral nutrition (PN) and must adhere to rigorous standards to avoid contamination of the sterile preparation. In March 2011, Serratia marcescens bloodstream infections (BSIs) were identified in 5 patients receiving PN from a single compounding pharmacy. An investigation was conducted to identify potential sources of contamination and prevent further infections. METHODS: Cases were defined as S. marcescens BSIs in patients receiving PN from the pharmacy between January and March 2011. We reviewed case patients' clinical records, evaluated pharmacy compounding practices, and obtained epidemiologically directed environmental cultures. Molecular relatedness of available Serratia isolates was determined by pulsed-field gel electrophoresis (PFGE). RESULTS: Nineteen case patients were identified; 9 died. The attack rate for patients receiving PN in March was 35%. No case patients were younger than 18 years. In October 2010, the pharmacy began compounding and filter-sterilizing amino acid solution for adult PN using nonsterile amino acids due to a national manufacturer shortage. Review of this process identified breaches in mixing, filtration, and sterility testing practices. S. marcescens was identified from a pharmacy water faucet, mixing container, and opened amino acid powder. These isolates were indistinguishable from the outbreak strain by PFGE. CONCLUSIONS: Compounding of nonsterile amino acid components of PN was initiated due to a manufacturer shortage. Failure to follow recommended compounding standards contributed to an outbreak of S. marcescens BSIs. Improved adherence to sterile compounding standards, critical examination of standards for sterile compounding from nonsterile ingredients, and more rigorous oversight of compounding pharmacies is needed to prevent future outbreaks.


Assuntos
Bacteriemia/epidemiologia , Surtos de Doenças , Nutrição Parenteral/efeitos adversos , Farmácia , Infecções por Serratia/epidemiologia , Serratia marcescens/isolamento & purificação , Adulto , Idoso , Idoso de 80 Anos ou mais , Composição de Medicamentos/normas , Eletroforese em Gel de Campo Pulsado , Feminino , Genótipo , Humanos , Masculino , Pessoa de Meia-Idade , Tipagem Molecular , Serratia marcescens/classificação , Serratia marcescens/genética
4.
MMWR Morb Mortal Wkly Rep ; 63(9): 201-2, 2014 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-24598597

RESUMO

In August 2013, the Maryland Department of Health and Mental Hygiene (MDHMH) was notified of two persons with rapidly growing nontuberculous mycobacterial (RG-NTM) surgical-site infections. Both patients had undergone surgical procedures as medical tourists at the same private surgical clinic (clinic A) in the Dominican Republic the previous month. Within 7 days of returning to the United States, both sought care for symptoms that included surgical wound abscesses, clear fluid drainage, pain, and fever. Initial antibiotic therapy was ineffective. Material collected from both patients' wounds grew Mycobacterium abscessus exhibiting a high degree of antibiotic resistance characteristic of this organism.


Assuntos
Surtos de Doenças , Turismo Médico , Infecções por Mycobacterium/epidemiologia , Mycobacterium/classificação , Procedimentos de Cirurgia Plástica/efeitos adversos , Infecção da Ferida Cirúrgica/epidemiologia , Adolescente , Adulto , Centers for Disease Control and Prevention, U.S. , República Dominicana , Feminino , Humanos , Pessoa de Meia-Idade , Mycobacterium/isolamento & purificação , Infecções por Mycobacterium/etiologia , Infecção da Ferida Cirúrgica/etiologia , Estados Unidos/epidemiologia , Adulto Jovem
5.
Aesthet Surg J ; 33(2): 265-9, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23335647

RESUMO

UNLABELLED: A cluster of 3 facial Mycobacterium chelonae infections occurred after cosmetic dermal filler injections at a plastic surgery clinic. Pulsed-field gel electrophoresis showed that M chelonae isolated from the clinic tap water were identical to the patient wound isolates. Review of injection procedures identified application of nonsterile ice to the skin prior to injection as a possible source of M chelonae. Surveys of regional laboratories and a national plastic surgery listserv identified no other cases related to the injection of this brand of dermal filler. This is the first report of cutaneous M chelonae infections following the injection of dermal fillers. It adds to a growing body of literature on postinjection M chelonae infections and reinforces the importance of optimal skin disinfection steps prior to percutaneous procedures. LEVEL OF EVIDENCE: 5.


Assuntos
Técnicas Cosméticas/efeitos adversos , Infecções por Mycobacterium não Tuberculosas/etiologia , Mycobacterium chelonae/isolamento & purificação , Técnicas Cosméticas/normas , Eletroforese em Gel de Campo Pulsado , Face , Feminino , Humanos , Gelo/normas , Pessoa de Meia-Idade , Infecções por Mycobacterium não Tuberculosas/diagnóstico , Infecções por Mycobacterium não Tuberculosas/microbiologia , Microbiologia da Água , Abastecimento de Água
6.
Foodborne Pathog Dis ; 9(9): 861-7, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22891917

RESUMO

Cronobacter (formerly known as Enterobacter sakazakii) is a genus comprising seven species regarded as opportunistic pathogens that can be found in a wide variety of environments and foods, including powdered infant formula (PIF). Cronobacter sakazakii, the major species of this genus, has been epidemiologically linked to cases of bacteremia, meningitis in neonates, and necrotizing enterocolitis, and contaminated PIF has been identified as an important source of infection. Robust and reproducible subtyping methods are required to aid in the detection and investigation, of foodborne outbreaks. In this study, a pulsed-field gel electrophoresis (PFGE) protocol was developed and validated for subtyping Cronobacter species. It was derived from an existing modified PulseNet protocol, wherein XbaI and SpeI were the primary and secondary restriction enzymes used, generating an average of 14.7 and 20.3 bands, respectively. The PFGE method developed was both reproducible and discriminatory for subtyping Cronobacter species.


Assuntos
Cronobacter/classificação , Tipagem Molecular/métodos , Análise do Polimorfismo de Comprimento de Fragmentos Amplificados , Animais , Cronobacter/genética , Cronobacter/isolamento & purificação , Cronobacter/metabolismo , Cronobacter sakazakii/classificação , Cronobacter sakazakii/genética , Cronobacter sakazakii/isolamento & purificação , Cronobacter sakazakii/metabolismo , Enzimas de Restrição do DNA , DNA Bacteriano/química , DNA Bacteriano/genética , DNA Bacteriano/metabolismo , Eletroforese em Gel de Campo Pulsado , Infecções por Enterobacteriaceae/diagnóstico , Infecções por Enterobacteriaceae/microbiologia , Alimentos em Conserva/microbiologia , Doenças Transmitidas por Alimentos/diagnóstico , Doenças Transmitidas por Alimentos/microbiologia , Humanos , Leite/microbiologia , Reprodutibilidade dos Testes , Vibrio cholerae/classificação , Vibrio cholerae/genética , Vibrio cholerae/isolamento & purificação , Vibrio cholerae/metabolismo , Yersinia pestis/classificação , Yersinia pestis/genética , Yersinia pestis/isolamento & purificação , Yersinia pestis/metabolismo
7.
Clin Infect Dis ; 48(11): 1580-3, 2009 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-19400746

RESUMO

We report 6 cases of postsurgical endophthalmitis due to gram-negative bacteria associated with contaminated trypan blue dye from a compounding pharmacy. Unopened trypan blue syringes yielded Pseudomonas aeruginosa and Burkholderia cepacia complex on culture, with pulsed-field gel electrophoresis patterns indistinguishable from patient isolates. Contamination of compounded medications should be considered when investigating outbreaks of postoperative endophthalmitis.


Assuntos
Infecção Hospitalar/epidemiologia , Surtos de Doenças , Contaminação de Medicamentos , Endoftalmite/epidemiologia , Infecções por Bactérias Gram-Negativas/epidemiologia , Soluções Oftálmicas , Infecção da Ferida Cirúrgica/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Complexo Burkholderia cepacia/classificação , Complexo Burkholderia cepacia/genética , Complexo Burkholderia cepacia/isolamento & purificação , Análise por Conglomerados , Infecção Hospitalar/microbiologia , Impressões Digitais de DNA , Eletroforese em Gel de Campo Pulsado , Endoftalmite/microbiologia , Genótipo , Infecções por Bactérias Gram-Negativas/microbiologia , Humanos , Masculino , Pessoa de Meia-Idade , Pseudomonas aeruginosa/classificação , Pseudomonas aeruginosa/genética , Pseudomonas aeruginosa/isolamento & purificação , Infecção da Ferida Cirúrgica/microbiologia , Azul Tripano
8.
Clin Infect Dis ; 47(11): 1372-9, 2008 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-18937575

RESUMO

BACKGROUND: Pharmaceutical compounding, the manipulation of ingredients to create a customized medication, is a widespread practice. In January 2005, the Centers for Disease Control and Prevention was notified of 4 cases of Pseudomonas fluorescens bacteremia that were traced to contaminated heparinized saline intravenous flush syringes prepared as a compounded medical product. PATIENTS AND METHODS: We reviewed medical records of symptomatic patients with P. fluorescens-positive cultures of blood specimens or sections of explanted catheters, reviewed the production process of syringes, performed syringe cultures, compared isolates by pulsed-field gel electrophoresis (PFGE), and examined catheters by scanning electron microscopy. RESULTS: We identified 80 patients in 6 states with P. fluorescens-positive cultures during December 2004-March 2006. Sixty-four patients (80%) had received a diagnosis of cancer. Seventy-four (99%) of 75 patients for whom information about catheter type was available had long-term indwelling catheters. Thirty-three (41%) of 80 cases were diagnosed 84-421 days after the patient's last potential exposure to a contaminated flush (delayed-onset cases). Compared with patients with early infection onset, more patients with delayed infection onset had venous ports (100% versus 50%; P <.001). By PFGE, clinical isolates from 50 (98%) of 51 patients were related to isolates cultured from unopened syringes. Scanning electron microscopy of explanted catheters revealed biofilms containing organisms morphologically consistent with P. fluorescens. CONCLUSION: This outbreak underscores important challenges in ensuring the safety of compounded pharmaceuticals and demonstrates the potential for substantially delayed infections after exposures to contaminated infusates. Exposures to compounded products should be considered when investigating outbreaks. Patients exposed to contaminated infusates require careful follow-up, because infections can occur long after exposure.


Assuntos
Bacteriemia/epidemiologia , Cateteres de Demora/efeitos adversos , Infecção Hospitalar/epidemiologia , Surtos de Doenças , Infecções por Pseudomonas/epidemiologia , Pseudomonas fluorescens/isolamento & purificação , Cloreto de Sódio/efeitos adversos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bacteriemia/microbiologia , Técnicas de Tipagem Bacteriana , Sangue/microbiologia , Cateteres de Demora/microbiologia , Criança , Pré-Escolar , Infecção Hospitalar/microbiologia , Eletroforese em Gel de Campo Pulsado , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Infecções por Pseudomonas/microbiologia , Pseudomonas fluorescens/classificação , Pseudomonas fluorescens/genética , Cloreto de Sódio/uso terapêutico
9.
N Engl J Med ; 352(5): 468-75, 2005 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-15689585

RESUMO

BACKGROUND: Methicillin-resistant Staphylococcus aureus (MRSA) is an emerging cause of infections outside of health care settings. We investigated an outbreak of abscesses due to MRSA among members of a professional football team and examined the transmission and microbiologic characteristics of the outbreak strain. METHODS: We conducted a retrospective cohort study and nasal-swab survey of 84 St. Louis Rams football players and staff members. S. aureus recovered from wound, nasal, and environmental cultures was analyzed by means of pulsed-field gel electrophoresis (PFGE) and typing for resistance and toxin genes. MRSA from the team was compared with other community isolates and hospital isolates. RESULTS: During the 2003 football season, eight MRSA infections occurred among 5 of the 58 Rams players (9 percent); all of the infections developed at turf-abrasion sites. MRSA infection was significantly associated with the lineman or linebacker position and a higher body-mass index. No MRSA was found in nasal or environmental samples; however, methicillin-susceptible S. aureus was recovered from whirlpools and taping gel and from 35 of the 84 nasal swabs from players and staff members (42 percent). MRSA from a competing football team and from other community clusters and sporadic cases had PFGE patterns that were indistinguishable from those of the Rams' MRSA; all carried the gene for Panton-Valentine leukocidin and the gene complex for staphylococcal-cassette-chromosome mec type IVa resistance (clone USA300-0114). CONCLUSIONS: We describe a highly conserved, community-associated MRSA clone that caused abscesses among professional football players and that was indistinguishable from isolates from various other regions of the United States.


Assuntos
Abscesso/microbiologia , Resistência a Meticilina , Infecções Cutâneas Estafilocócicas/microbiologia , Staphylococcus aureus/genética , Abscesso/epidemiologia , Adulto , Células Clonais , Estudos de Coortes , Infecções Comunitárias Adquiridas/epidemiologia , Infecções Comunitárias Adquiridas/microbiologia , Surtos de Doenças , Eletroforese em Gel de Campo Pulsado , Futebol Americano , Géis , Humanos , Hidroterapia , Masculino , Testes de Sensibilidade Microbiana , Nariz/microbiologia , Estudos Retrospectivos , Fatores de Risco , Pele/lesões , Pele/microbiologia , Infecções Estafilocócicas/epidemiologia , Infecções Estafilocócicas/microbiologia , Infecções Cutâneas Estafilocócicas/epidemiologia , Infecções Cutâneas Estafilocócicas/transmissão , Staphylococcus aureus/classificação , Staphylococcus aureus/isolamento & purificação , Estados Unidos/epidemiologia
10.
Appl Environ Microbiol ; 74(8): 2480-7, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18310417

RESUMO

Between March and May 2006, a Texas hospital identified five Mycobacterium mucogenicum bloodstream infections among hospitalized oncology patients using fluorescence high-performance liquid chromatography analysis of mycolic acids. Isolates from blood cultures were compared to 16 isolates from environmental sites or water associated with this ward. These isolates were further characterized by hsp65, 16S rRNA, and rpoB gene sequencing, hsp65 PCR restriction analysis, and molecular typing methods, including repetitive element PCR, random amplified polymorphic DNA PCR, and pulsed-field gel electrophoresis (PFGE) of large restriction fragments. Three of five patient isolates were confirmed as M. mucogenicum and were in a single cluster as determined by all identification and typing methods. The remaining two patient isolates were identified as different strains of Mycobacterium phocaicum by rpoB sequence analysis. One of these matched an environmental isolate from a swab of a hand shower in the patient's room, while none of the clinical isolates of M. mucogenicum matched environmental strains. Among the other 15 environmental isolates, 11 were identified as M. mucogenicum and 4 as M. phocaicum strains, all of which were unrelated by typing methods. Although the 16S rRNA gene sequences matched for all 14 M. mucogenicum isolates, there were two each of the hsp65 and rpoB sequevars, seven PCR typing patterns, and 12 PFGE patterns. Among the seven M. phocaicum isolates were three 16S rRNA sequevars, two hsp65 sequevars, two rpoB sequevars, six PCR typing patterns, and six PFGE patterns. This outbreak represents the first case of catheter-associated bacteremia caused by M. phocaicum and the first report of clinical isolates from a U.S. hospital. The investigation highlights important differences in the available typing methods for mycobacteria and demonstrates the genetic diversity of these organisms even within narrow confines of time and space.


Assuntos
Bacteriemia/microbiologia , Infecção Hospitalar/microbiologia , Surtos de Doenças , Microbiologia Ambiental , Variação Genética , Infecções por Mycobacterium/microbiologia , Mycobacterium/classificação , Idoso , Bacteriemia/epidemiologia , Proteínas de Bactérias/genética , Técnicas de Tipagem Bacteriana , Chaperonina 60 , Chaperoninas/genética , Análise por Conglomerados , Infecção Hospitalar/epidemiologia , Impressões Digitais de DNA , DNA Bacteriano/química , DNA Bacteriano/genética , DNA Ribossômico/química , DNA Ribossômico/genética , RNA Polimerases Dirigidas por DNA/genética , Eletroforese em Gel de Campo Pulsado , Feminino , Genótipo , Hospitais , Humanos , Masculino , Epidemiologia Molecular , Dados de Sequência Molecular , Mycobacterium/genética , Mycobacterium/isolamento & purificação , Infecções por Mycobacterium/epidemiologia , Reação em Cadeia da Polimerase , RNA Ribossômico 16S/genética , Técnica de Amplificação ao Acaso de DNA Polimórfico , Análise de Sequência de DNA , Texas/epidemiologia
11.
Transfusion ; 48(10): 2177-83, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18564393

RESUMO

BACKGROUND: An elderly man with chronic myelomonocytic leukemia developed respiratory distress and died less than 48 hours after transfusion of a pool of eight whole blood-derived platelets (PLTs). Blood cultures from the recipient and cultures of remnants from the pooled PLT bag grew group C streptococci (GCS). An investigation was conducted to identify both the infection's source and the reasons for the false-negative screening result. STUDY DESIGN AND METHODS: Red blood cell (RBC) units (cocomponent from the eight donations) were traced, quarantined, and cultured. Specimens from the implicated donor were obtained. Isolates were identified and typed by 16S rRNA and pulsed-field gel electrophoresis (PFGE). The blood center screening method was reviewed. RESULTS: beta-Hemolytic GCS, cultured from 1 of 8 RBC units, linked the fatal case to a single donor. The donor's throat swab collected 20 days after donation was positive for the presence of GCS, identified as Streptococcus dysgalactiae subsp. equisimilis. Isolates from the recipient, RBC unit, residual PLTs, and donor's throat swab were indistinguishable by PFGE. The donor denied any symptoms of infection before or after donation. PLT bacterial screening at the blood center was performed using a commercially available bacterial detection system (BacT/ALERT, bioMérieux) with a threshold of 15 colony-forming units per bag. CONCLUSION: An asymptomatic donor was implicated as the source of GCS-contaminated PLTs. Current screening methods for PLTs are not sufficient to detect all bacterial contamination. Pooled PLTs are a particular challenge because the small volume of individual units places limits on culturing strategies. Improved detection of bacterial contamination of PLTs is needed.


Assuntos
Plaquetas/microbiologia , Transfusão de Plaquetas/efeitos adversos , Infecções Estreptocócicas/transmissão , Streptococcus/isolamento & purificação , Idoso , Doadores de Sangue , Evolução Fatal , Humanos , Masculino , Técnicas Microbiológicas , Streptococcus/classificação
12.
Clin Infect Dis ; 45(5): 527-33, 2007 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-17682984

RESUMO

BACKGROUND: In contrast to pharmaceutical manufacturers, compounding pharmacies adhere to different quality-control standards, which may increase the likelihood of undetected outbreaks. In 2005, the Centers for Disease Control and Prevention received reports of cases of Serratia marcescens bloodstream infection occurring in patients who underwent cardiac surgical procedures in Los Angeles, California, and in New Jersey. An investigation was initiated to determine whether there was a common underlying cause. METHODS: A matched case-control study was conducted in Los Angeles. Case record review and environmental testing were conducted in New Jersey. The Centers for Disease Control and Prevention performed a multistate case-finding investigation; isolates were compared using pulsed-field gel electrophoresis analysis. RESULTS: Nationally distributed magnesium sulfate solution (MgSO(4)) from compounding pharmacy X was the only significant risk factor for S. marcescens bloodstream infection (odds ratio, 6.4; 95% confidence interval, 1.1-38.3) among 6 Los Angeles case patients and 18 control subjects. Five New Jersey case patients received MgSO(4) from a single lot produced by compounding pharmacy X; culture of samples from open and unopened 50-mL bags in this lot yielded S. marcescens. Seven additional case patients from 3 different states were identified. Isolates from all 18 case patients and from samples of MgSO(4) demonstrated indistinguishable pulsed-field gel electrophoresis patterns. Compounding pharmacy X voluntarily recalled the product. Neither the pharmacy nor the US Food and Drug Administration could identify a source of contamination in their investigations of compounding pharmacy X. CONCLUSIONS: A multistate outbreak of S. marcescens bloodstream infection was linked to contaminated MgSO(4) distributed nationally by a compounding pharmacy. Health care personnel should take into account the different quality standards and regulation of compounded parenteral medications distributed in large quantities during investigations of outbreaks of bloodstream infection.


Assuntos
Bacteriemia/epidemiologia , Fármacos Cardiovasculares/efeitos adversos , Surtos de Doenças , Contaminação de Medicamentos , Sulfato de Magnésio/efeitos adversos , Infecções por Serratia/etiologia , Serratia marcescens/patogenicidade , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bacteriemia/microbiologia , Procedimentos Cirúrgicos Cardíacos , Centers for Disease Control and Prevention, U.S./estatística & dados numéricos , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/microbiologia , Composição de Medicamentos/efeitos adversos , Composição de Medicamentos/normas , Feminino , Humanos , Los Angeles/epidemiologia , Masculino , Pessoa de Meia-Idade , New Jersey/epidemiologia , Fatores de Risco , Infecções por Serratia/epidemiologia , Serratia marcescens/isolamento & purificação , Estados Unidos
13.
Chest ; 132(6): 1825-31, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17925414

RESUMO

BACKGROUND: No guidelines exist for the type of mouthwash that should be used in patients at increased risk for pneumonia. In 2005, we investigated a multistate outbreak of Burkholderia cenocepacia associated with an intrinsically contaminated alcohol-free mouthwash (AFM). METHODS: We conducted a case-series investigation. We used repetitive extragenic palindromic- polymerase chain reaction typing and pulsed-field gel electrophoresis (PFGE) to characterize available Burkholderia cepacia complex (Bcc) isolates from patients and implicated AFM. Seeding studies were conducted to determine the antimicrobial activity of the AFM. RESULTS: Of the 116 patients with Bcc infection or colonization identified from 22 hospitals with culture dates from April 7 through August 31, 2005, 105 had infections or colonizations that were due to B cenocepacia. The median age of these 105 patients was 64 years (range, 6 to 94 years), 52% were women, 55% had evidence of infection, and 2 patients died. Of 139 patient culture specimens, 83 (60%) were from the respiratory tract. Among 103 Bcc patient isolates characterized, 81 (76%) had an indistinguishable PFGE pattern compared to the outbreak strain cultured from implicated lots of unopened AFM; the species was B cenocepacia. Seeding studies showed that the contaminated AFM might have had inadequate amounts of the antimicrobial agent cetylpyridinium chloride. CONCLUSIONS: This intrinsically contaminated AFM led to a geographically dispersed outbreak of B cenocepacia. AFM without therapeutic label claims is regulated by the US Food and Drug Administration as a cosmetic rather than a drug and is therefore subject to limited quality control requirements. Clinicians should be aware that AFM is not sterile. Its use in intubated and other patients with increased risk of aspiration should be avoided.


Assuntos
Infecções por Burkholderia/etiologia , Burkholderia cepacia/patogenicidade , Surtos de Doenças , Contaminação de Medicamentos , Antissépticos Bucais , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Infecções por Burkholderia/epidemiologia , Burkholderia cepacia/isolamento & purificação , Estudos de Casos e Controles , Criança , Eletroforese em Gel de Campo Pulsado , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase , Estados Unidos/epidemiologia
14.
Infect Control Hosp Epidemiol ; 28(11): 1311-3, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17926285

RESUMO

We investigated an outbreak of infection in 10 patients with blood cultures positive for B. cepacia. All patients had indwelling intravenous catheters. Though we did not identify the source of the organism, our findings support the hypothesis that cross-contamination of multidose medications through the use of the same needle and syringe was a contributing factor.


Assuntos
Infecções por Burkholderia/etiologia , Burkholderia cepacia , Surtos de Doenças , Sepse/etiologia , Idoso , Instituições de Assistência Ambulatorial , Infecções por Burkholderia/tratamento farmacológico , Infecções por Burkholderia/epidemiologia , Estudos de Casos e Controles , Cateterismo Venoso Central/efeitos adversos , Contaminação de Equipamentos , Feminino , Georgia/epidemiologia , Hematologia , Humanos , Masculino , Oncologia , Pessoa de Meia-Idade , Fatores de Risco , Sepse/epidemiologia , Sepse/microbiologia
15.
Infect Control Hosp Epidemiol ; 28(5): 614-7, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17464927

RESUMO

In September of 2004, we investigated 7 cases of post-myelography meningitis. Streptococcal species were recovered from blood or cerebrospinal fluid in all cases. Our findings suggest that droplet transmission of the oral flora of the clinician performing the procedure was the most likely source of these infections. The Centers for Disease Control and Prevention recommends the use of face masks by those performing myelograms.


Assuntos
Poluição do Ar em Ambientes Fechados/efeitos adversos , Infecção Hospitalar/transmissão , Transmissão de Doença Infecciosa do Profissional para o Paciente , Meningites Bacterianas/transmissão , Mielografia/efeitos adversos , Infecções Estreptocócicas/transmissão , Infecção Hospitalar/microbiologia , Humanos , Controle de Infecções/métodos , Máscaras/estatística & dados numéricos , Meningites Bacterianas/etiologia , Meningites Bacterianas/microbiologia , Infecções Estreptocócicas/etiologia , Infecções Estreptocócicas/microbiologia
16.
Arch Intern Med ; 166(22): 2518-24, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17159019

RESUMO

BACKGROUND: Increased Clostridium difficile-associated disease (CDAD) in a hospital and an affiliated long-term care facility continued despite infection control measures. We investigated this outbreak to determine risk factors and transmission settings. METHODS: The CDAD cases were compared according to where the disease was likely acquired based on health care exposure and characterization of isolates from case patients, asymptomatic carriers, and the environment. Antimicrobial susceptibility testing, strain typing using pulsed-field gel electrophoresis, and toxinotyping were performed, and toxins A and B, binary toxin, and deletions in the tcdC gene were detected using polymerase chain reaction. Risk factors were examined in a case-control study, and overall antimicrobial use was compared at the hospital before and during the outbreak. RESULTS: Significant increases were observed in hospital-acquired (0.19 vs 0.86; P < .001) and long-term care facility-acquired (0.04 vs 0.31; P = .004) CDAD cases per 100 admissions as a result of transmission of a toxinotype III strain at the hospital and a toxinotype 0 strain at the long-term care facility. The toxinotype III strain was positive for binary toxin, an 18-base pair deletion in tcdC, and increased resistance to fluoroquinolones. Independent risk factors for CDAD included use of fluoroquinolones (odds ratio [OR], 3.22; P = .04), cephalosporins (OR, 5.19; P = .006), and proton pump inhibitors (OR, 5.02; P = .02). A significant increase in fluoroquinolone use at the hospital took place during the outbreak (185.5 defined daily doses per 1000 patient-days vs 200.9 defined daily doses per 1000 patient-days; P < .001). CONCLUSIONS: The hospital outbreak of CDAD was caused by transmission of a more virulent, fluoroquinolone-resistant strain of C difficile. More selective fluoroquinolone and proton pump inhibitor use may be important in controlling and preventing such outbreaks.


Assuntos
Clostridioides difficile , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/microbiologia , Surtos de Doenças , Enterocolite Pseudomembranosa/epidemiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Anti-Infecciosos/uso terapêutico , Estudos de Casos e Controles , Eletroforese em Gel de Campo Pulsado , Feminino , Fluoroquinolonas/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Instituições Residenciais , Fatores de Risco
17.
Infect Control Hosp Epidemiol ; 38(3): 314-319, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27919308

RESUMO

OBJECTIVE To determine the source of a healthcare-associated outbreak of Pantoea agglomerans bloodstream infections. DESIGN Epidemiologic investigation of the outbreak. SETTING Oncology clinic (clinic A). METHODS Cases were defined as Pantoea isolation from blood or catheter tip cultures of clinic A patients during July 2012-May 2013. Clinic A medical charts and laboratory records were reviewed; infection prevention practices and the facility's water system were evaluated. Environmental samples were collected for culture. Clinical and environmental P. agglomerans isolates were compared using pulsed-field gel electrophoresis. RESULTS Twelve cases were identified; median (range) age was 65 (41-78) years. All patients had malignant tumors and had received infusions at clinic A. Deficiencies in parenteral medication preparation and handling were identified (eg, placing infusates near sinks with potential for splash-back contamination). Facility inspection revealed substantial dead-end water piping and inadequate chlorine residual in tap water from multiple sinks, including the pharmacy clean room sink. P. agglomerans was isolated from composite surface swabs of 7 sinks and an ice machine; the pharmacy clean room sink isolate was indistinguishable by pulsed-field gel electrophoresis from 7 of 9 available patient isolates. CONCLUSIONS Exposure of locally prepared infusates to a contaminated pharmacy sink caused the outbreak. Improvements in parenteral medication preparation, including moving chemotherapy preparation offsite, along with terminal sink cleaning and water system remediation ended the outbreak. Greater awareness of recommended medication preparation and handling practices as well as further efforts to better define the contribution of contaminated sinks and plumbing deficiencies to healthcare-associated infections are needed. Infect Control Hosp Epidemiol 2017;38:314-319.


Assuntos
Bacteriemia/diagnóstico , Infecção Hospitalar/diagnóstico , Surtos de Doenças , Contaminação de Medicamentos , Pantoea/isolamento & purificação , Adulto , Idoso , Eletroforese em Gel de Campo Pulsado , Contaminação de Equipamentos , Feminino , Humanos , Illinois , Masculino , Pessoa de Meia-Idade , Serviço Hospitalar de Oncologia
18.
Chest ; 130(5): 1346-53, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17099009

RESUMO

BACKGROUND: Species within the Burkholderia cepacia complex (Bcc) can contaminate medications and disinfectants and cause severe pneumonia in critically ill patients or persons with cystic fibrosis. In March 2004, we investigated a hospital outbreak of Bcc possibly associated with a contaminated nasal spray. METHODS: We conducted a matched case-control study, environmental sampling, and observations of infection control practices. Case patients had infection or colonization with Bcc, and control patients had sputum culture not yielding Bcc. Isolates from patients and environmental samples were compared by pulsed-field gel electrophoresis (PFGE). RESULTS: Bcc was recovered from sputum in 18 patients. Compared with matched control patients (n = 18), case patients were more likely to be receiving mechanical ventilation (p = 0.01), to have been hospitalized > 6 days (p = 0.01), and to have received antimicrobial treatment within 7 days before sputum collection (p = 0.03). Bcc was cultured from opened, but not unopened, multidose albuterol bottles, a nebulizer attached to a ventilator, and opened and unopened nasal spray bottles from contaminated lots. PFGE showed that isolates from albuterol samples and from patients were indistinguishable but unrelated to the nasal spray strain. Observations revealed improper aseptic techniques during respiratory therapy procedures and inadequate nebulizer cleaning. CONCLUSIONS: Despite a temporal association with use of a contaminated nasal spray, this outbreak was caused by extrinsic contamination of multidose albuterol used for nebulization treatments and lack of adherence to infection control precautions. Implementation and re-enforcement of infection control measures successfully terminated the outbreak.


Assuntos
Albuterol/administração & dosagem , Broncodilatadores/administração & dosagem , Infecções por Burkholderia/etiologia , Burkholderia cepacia/patogenicidade , Surtos de Doenças , Contaminação de Medicamentos , Administração Intranasal , Adulto , Idoso , Albuterol/uso terapêutico , Broncodilatadores/uso terapêutico , Infecções por Burkholderia/epidemiologia , Estudos de Casos e Controles , Infecção Hospitalar/prevenção & controle , Infecção Hospitalar/transmissão , Surtos de Doenças/prevenção & controle , Contaminação de Equipamentos/prevenção & controle , Feminino , Humanos , Controle de Infecções/métodos , Masculino , Pessoa de Meia-Idade , Nebulizadores e Vaporizadores/microbiologia , Escarro/microbiologia , Ventiladores Mecânicos/microbiologia
19.
Arch Intern Med ; 165(22): 2639-43, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16344422

RESUMO

BACKGROUND: In March 2004, the Chicago Department of Public Health was notified of a cluster of bloodstream infections with Klebsiella oxytoca and Enterobacter cloacae at a chemotherapy center. Our purpose was to identify the source of the outbreak and prevent further cases. METHODS: The investigation included 103 oncology patients seen at an outpatient oncology chemotherapy center in Chicago during the 16 days before its closure. The outbreak investigation included case identification, retrospective cohort study, review of medical records, microbiologic testing of blood specimens, environmental cultures, and pulsed-field gel electrophoresis. The main outcome measure was infection with K oxytoca, E cloacae, or both, and the Mantel-Haenszel chi(2) test was used to assess risk of infection in relation to presence of central venous catheter. RESULTS: Among the 103 patients, risk of infection was associated with the presence of central venous catheter (relative risk undefined, P<.001). Twenty-seven patients had blood cultures that grew K oxytoca, E cloacae, or both, and all had central venous catheters that were flushed with isotonic sodium chloride solution at the clinic from February 17 through March 3, 2004. Isolates of K oxytoca and E cloacae were matched by pulsed-field gel electrophoresis to K oxytoca and E cloacae isolates obtained from multiple predrawn syringes and from the intravenous fluid and administration set in use in the clinic at the time of its closing. CONCLUSIONS: The injection of contaminated isotonic sodium chloride solution through the venous catheters of attendees at the clinic likely provided the opportunity for bloodstream infections in these 27 case patients. This outbreak highlights the need for continued emphasis on safe injection practices and suggests the need for guidelines and recommendations tailored to outpatient settings.


Assuntos
Bacteriemia/epidemiologia , Infecção Hospitalar/epidemiologia , Surtos de Doenças , Infecções por Enterobacteriaceae/epidemiologia , Infecções por Klebsiella/epidemiologia , Adulto , Idoso , Instituições de Assistência Ambulatorial , Antineoplásicos/administração & dosagem , Bacteriemia/etiologia , Bacteriemia/microbiologia , Institutos de Câncer , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/instrumentação , Cateterismo Venoso Central/enfermagem , Chicago/epidemiologia , Estudos de Coortes , Infecção Hospitalar/etiologia , Infecção Hospitalar/microbiologia , Enterobacter cloacae/isolamento & purificação , Contaminação de Equipamentos , Reutilização de Equipamento , Feminino , Humanos , Klebsiella oxytoca/isolamento & purificação , Masculino , Pessoa de Meia-Idade , Neoplasias/tratamento farmacológico , Estudos Retrospectivos
20.
Genome Announc ; 4(2)2016 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-26988052

RESUMO

Mycobacterium wolinskyi is a nonpigmented, rapidly growing nontuberculous mycobacterium species that is associated with bacteremia, peritonitis, infections associated with implants/prostheses, and skin and soft tissue infections often following surgical procedures in humans. Here, we report the first functionally annotated draft genome sequence of M. wolinskyi CDC_01.