Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Scand J Gastroenterol ; 57(5): 545-557, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35049405

RESUMO

BACKGROUND: Endoscopic ultrasound-guided liver biopsy (EUS-LB) is an evolving technique. In this meta-analysis, we aimed to evaluate the value of EUS-LB for parenchymal and focal liver lesions. Besides, we aimed to assess the influences of needle-related factors on the performance of EUS-LB. Additionally, we aimed to assess the influence of various criteria on specimen adequacy. METHODS: We searched the PubMed, Embase, Cochrane Library databases up to 10 October 2021. The primary outcome was diagnostic yield, specimen adequacy, qualified specimens evaluated by rapid on-site evaluation (ROSE). The secondary outcome was adverse events. Subgroup analyses were based on needle type, needle size, fine-needle biopsy (FNB) needle type. A sensitivity analysis was conducted on specimen adequacy based on two definition criteria. RESULTS: In total, 33 studies were included. Pooled rates of diagnostic yield, specimen adequacy, qualified specimen by ROSE, adverse events were 95%, 84%, 93%, 3%. Subgroup analyses showed that Acquire needles generated higher diagnostic yield than SharkCore needles (99% vs. 88%, p = .047). Additionally, FNB needles demonstrated a higher rate of adverse events than FNA needles (6% vs. 1%, p = .028). Sensitivity analysis on specimen adequacy based on various criteria demonstrated that the specimen adequacy rate defined by the AASLD criterion was lower than that of the commonly-used criterion (37% vs. 84%, p = .001). CONCLUSION: EUS-LB is effective and safe for liver biopsy. Acquire needles provide better specimens than SharkCore needles. FNB needles may increase the risk of adverse events compared with FNA needles. The AASLD criterion is harder to achieve than the commonly-used criterion.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Fígado , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/efeitos adversos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Endossonografia/métodos , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Ultrassonografia
2.
Front Oncol ; 14: 1393430, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38800407

RESUMO

Malignant glomus tumor (MGT) is a rare mesenchymal neoplasm. It is rarely located in the breast. We present a case of a 57-year-old female patient presenting with complaints of a progressively growing mass found in her left breast. Though multiple imaging examinations have been performed, especially multimodal ultrasound examinations, an accurate diagnosis still cannot be determined. Finally, the lesion was confirmed to be a MGT of the breast by postoperative pathological diagnosis. In conclusion, MGT originating from breast is extremely rare. No such case has ever been described before. This study demonstrates the imaging characteristics of a patient with MGT of the breast in order to provide more extensive insights to consider the differential diagnosis of breast lesions.

3.
Front Oncol ; 14: 1410057, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38957316

RESUMO

A 54-year-old woman was admitted to the hospital with a left neck mass. Enhanced CT and ultrasound examinations revealed a lesion in the left sternocleidomastoid muscle. The patient undergone right thyroid lobe resection 8 years ago. Interestingly, the lesion on the sternocleidomastoid muscle, along with the left lobe of the patient's thyroid, visually appears to form a displaced and complete thyroid in the early Tc-99m-MIBI parathyroid scintigraphy. Combined with Tc-99m-MIBI scintigraphy and abnormal PTH and blood calcium levels, the consideration was given to the lesion in the sternocleidomastoid muscle as an ectopic parathyroid adenoma. Subsequent surgical pathology confirmed this suspicion.

4.
World J Gastrointest Surg ; 16(2): 616-621, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38463358

RESUMO

BACKGROUND: The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma. Consequently, a definitive diagnosis primarily relies on histological results. The ultrasound (US)-guided coaxial core needle biopsy (CNB) not only procures sufficient tissue to help clarify the diagnosis, but reduces the incidence of puncture-related complications. CASE SUMMARY: A 41-year-old female, with a history of pulmonary tuberculosis, was admitted to our hospital with multiple indeterminate splenic lesions. Gray-scale ultrasonography demonstrated splenomegaly with numerous well-defined hypoechoic masses. Abdominal contrast-enhanced computed tomography (CT) showed an enlarged spleen with multiple irregular-shaped, peripherally enhancing, hypodense lesions. Positron emission CT revealed numerous abnormal hyperglycemia foci. These imaging findings strongly indicated the possibility of infectious disease as the primary concern, with neoplastic lesions requiring exclusion. To obtain the precise pathological diagnosis, the US-guided coaxial CNB of the spleen was carried out. The patient did not express any discomfort during the procedure. CONCLUSION: Percutaneous US-guided coaxial CNB is an excellent and safe option for obtaining precise splenic tissue samples, as it significantly enhances sample yield for exact pathological analysis with minimum trauma to the spleen parenchyma and surrounding tissue.

5.
Front Oncol ; 13: 1108133, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36741018

RESUMO

Adult-type rhabdomyoma (AR) is a benign myogenous neoplasm. It is rarely located in the thyroid. We present a case of a 61-year-old man, presenting with complaints of a mass found in his left neck for three years. Ultrasonography and computed tomography showed a mass in the left lobe of the thyroid. Subsequently, a fine-needle aspiration biopsy showed that the lesion was suspected to be an oncocytic neoplasm, and the patient underwent surgery. Finally, the lesion was confirmed to be an AR of the thyroid by postoperative pathological diagnosis. In conclusion, AR that occurs in the thyroid is remarkably rare. No case reports to date have described in detail the imaging findings of AR in the thyroid. This study demonstrates the imaging characteristics of a patient with AR of the thyroid, in order to provide more extensive insights to consider the differential diagnosis of thyroid lesions.

6.
Chin Med J (Engl) ; 136(17): 2028-2036, 2023 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-36728948

RESUMO

BACKGROUND: Patients with mass-forming pancreatitis (MFP) or pancreatic ductal adenocarcinoma (PDAC) presented similar clinical symptoms, but required different treatment approaches and had different survival outcomes. This meta-analysis aimed to compare the diagnostic performance of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) in differentiating MFP from PDAC. METHODS: A literature search was performed in the PubMed, EMBASE (Ovid), Cochrane Library (CENTRAL), China National Knowledge Infrastructure (CNKI), Weipu (VIP), and WanFang databases to identify original studies published from inception to August 20, 2021. Studies reporting the diagnostic performances of CEUS and CECT for differentiating MFP from PDAC were included. The meta-analysis was performed with Stata 15.0 software. The outcomes included the pooled sensitivity, specificity, positive likelihood ratio (+LR), negative likelihood ratio (-LR), diagnostic odds ratio (DOR), and summary receiver operating characteristic (SROC) curves of CEUS and CECT. Meta-regression was conducted to investigate heterogeneity. Bayesian network meta-analysis was conducted to indirectly compare the overall diagnostic performance. RESULTS: Twenty-six studies with 2115 pancreatic masses were included. The pooled sensitivity and specificity of CEUS for MFP were 82% (95% confidence interval [CI], 73%-88%; I2  = 0.00%) and 95% (95% CI, 90%-97%; I2  = 63.44%), respectively; the overall +LR, -LR, and DOR values were 15.12 (95% CI, 7.61-30.01), 0.19 (95% CI, 0.13-0.29), and 78.91 (95% CI, 30.94-201.27), respectively; and the area under the SROC curve (AUC) was 0.90 (95% CI, 0.87-92). However, the overall sensitivity and specificity of CECT were 81% (95% CI, 75-85%; I2  = 66.37%) and 94% (95% CI, 90-96%; I2  = 74.87%); the overall +LR, -LR, and DOR values were 12.91 (95% CI, 7.86-21.20), 0.21 (95% CI, 0.16-0.27), and 62.53 (95% CI, 34.45-113.51), respectively; and, the SROC AUC was 0.92 (95% CI, 0.90-0.94). The overall diagnostic accuracy of CEUS was comparable to that of CECT for the differential diagnosis of MFP and PDAC (relative DOR 1.26, 95% CI [0.42-3.83], P  > 0.05). CONCLUSIONS: CEUS and CECT have comparable diagnostic performance for differentiating MFP from PDAC, and should be considered as mutually complementary diagnostic tools for suspected focal pancreatic lesions.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Pancreatite , Humanos , Meios de Contraste , Teorema de Bayes , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Carcinoma Ductal Pancreático/diagnóstico por imagem , Sensibilidade e Especificidade , Pancreatite/diagnóstico por imagem , Ultrassonografia/métodos , Neoplasias Pancreáticas
7.
Front Oncol ; 13: 1140277, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37007159

RESUMO

Objectives: To compare the diagnostic efficacy of SonoVue-enhanced and Sonazoid-enhanced ultrasound (US) for hepatocellular carcinoma (HCC) in patients at high risk. Methods: Between August 2021 and February 2022, participants at high risk for HCC with focal liver lesions were enrolled and underwent both SonoVue- and Sonazoid-enhanced US. Vascular-phase and Kupffer phase (KP) imaging features of contrast-enhanced US (CEUS) were analyzed. The diagnostic performance of both contrast agent-enhanced US according to the CEUS liver imaging reporting and data system (LI-RADS) and the modified criteria (using KP defect instead of late and mild washout) were compared. Histopathology and contrast-enhanced MRI/CT were used as reference standards. Results: In total, 62 nodules, namely, 55 HCCs, 3 non-HCC malignancies and 4 hemangiomas, from 59 participants were included. SonoVue-enhanced US had comparable sensitivity to Sonazoid-enhanced US for diagnosing HCC [80% (95% confidential interval (CI): 67%, 89.6%) versus 74.6% (95% CI: 61%, 85.3%), p = 0.25]. Both SonoVue and Sonazoid-enhanced US achieved a specificity of 100%. Compared with CEUS LI-RADS, the modified criteria with Sonazoid did not improve sensitivity for HCC diagnosis [74.6% (95% CI: 61%, 85.3%) versus 76.4% (95% CI: 63%, 86.8%), p = 0.99]. Conclusions: Sonazoid-enhanced US had comparable diagnostic performance to SonoVue-enhanced US for patients with HCC risk. KP did not considerably improve the diagnostic efficacy, whereas KP defects in atypical hemangioma may be pitfalls in diagnosing HCC. Further studies with larger sample sizes are needed to further validate the conclusions in the present study.

8.
Front Surg ; 9: 874006, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35465421

RESUMO

Pancreatic neurofibroma is a very rare benign neurogenic tumor unrelated to neurofibromatosis type 1 (NF-1). As the volume increases, it has the risk of malignant transformation. The surgical prognosis of pancreatic neurofibroma is good, but its preoperative imaging features are very similar to those of malignant tumors, which may affect the formulation of treatment plans. This article reports a case of giant neurofibroma of the pancreas with contrast-enhanced ultrasound (CEUS) as one of the diagnostic methods and discusses the tumor's preoperative clinical features, laboratory examinations, and imaging features.

9.
World J Gastroenterol ; 28(21): 2350-2360, 2022 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-35800178

RESUMO

BACKGROUND: Contrast-enhanced ultrasound (CEUS) can be used to diagnose focal liver lesions (FLLs) in children. The America College of Radiology developed the CEUS liver imaging reporting and data system (LI-RADS) for standardizing CEUS diagnosis of FLLs in adult patients. Until now, no similar consensus or guidelines have existed for pediatric patients to improve imaging interpretation as adults. AIM: To evaluate the performance of CEUS LI-RADS combined with alpha-fetoprotein (AFP) in differentiating benign and malignant FLLs in pediatric patients. METHODS: Between January 2011 and January 2021, patients ≤ 18 years old who underwent CEUS for FLLs were retrospectively evaluated. The following criteria for diagnosing malignancy were proposed: Criterion I considered LR-4, LR-5, or LR-M lesions as malignancies; criterion II regarded LR-4, LR-5 or LR-M lesions with simultaneously elevated AFP (≥ 20 ng/mL) as malignancies; criterion III took LR-4 Lesions with elevated AFP or LR-5 or LR-M lesions as malignancies. The sensitivity, specificity, accuracy and area under the receiver operating characteristic curve (AUC) were calculated to determine the diagnostic value of the aforementioned criteria. RESULTS: The study included 63 nodules in 60 patients (mean age, 11.0 ± 5.2 years; 26 male). There were no statistically significant differences between the specificity, accuracy, or AUC of criterion II and criterion III (95.1% vs 80.5%, 84.1% vs 87.3%, and 0.794 vs 0.902; all P > 0.017). Notably, criterion III showed a higher diagnostic sensitivity than criterion II (100% vs 63.6%; P < 0.017). However, both the specificity and accuracy of criterion I was inferior to those of criterion II and criterion III (all P < 0.017). For pediatric patients more than 5 years old, the performance of the three criteria was overall similar when patients were subcategorized by age when compared to all patients in aggregate. CONCLUSION: CEUS LI-RADS combined with AFP may be a powerful diagnostic tool in pediatric patients. LR-4 with elevated AFP, LR-5 or LR-M lesions is highly suggestive of malignant tumors.


Assuntos
Carcinoma Hepatocelular , Doenças do Sistema Digestório , Neoplasias Hepáticas , Adolescente , Adulto , Carcinoma Hepatocelular/patologia , Criança , Pré-Escolar , Meios de Contraste , Humanos , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Estudos Retrospectivos , Sensibilidade e Especificidade , alfa-Fetoproteínas
10.
Bioresour Technol ; 100(14): 3663-8, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19342231

RESUMO

A sludge pyrolytic kinetics model was established in this study. Two types of sewage sludge from different industrial wastewater treatment plant produced different DTG (Derivative Thermogravimetry) shapes with an overlapping pattern. The multi-heating rate method was conducted to evaluate the kinetics for obtaining reasonable pyrolysis mechanisms and DTG curves were divided into several peaks using the Lorentz fitting method based on the composition of the sludge and the desire for precision. The peaks formed corresponded to the pyrolysis reactions of volatile matter, microbe cells, proteins, inorganic substances and char respectively, which can be reasonably explained based on the results from the flue gas analyzer and the chemical analysis. Two types of sewage sludge were found to have similar pyrolysis mechanisms. Reasonable reasons were also given to explain the distortion and lag observed in the DTG curves and pyrolysis mechanism.


Assuntos
Biotecnologia/métodos , Resíduos Industriais , Esgotos/química , Purificação da Água/métodos , Temperatura Alta , Cinética , Modelos Estatísticos , Proteínas/química , Temperatura , Termogravimetria , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa