RESUMO
Here, we report a novel, feasible, and cost-effective method for the preparation of one-dimensional TiO2 nanowire arrays using a super-aligned carbon nanotube film as a template. Pure-anatase-phase TiO2 nanowires were scalably prepared in a suspended manner, and a high-performance ultraviolet (UV) photodetector was realized on a flexible substrate. The large surface area and one-dimensional nanostructure of the TiO2 nanowire array led to a high detectivity (1.35 × 1016 Jones) and an ultrahigh photo gain (2.6 × 104), respectively. A high photoresponsivity of 7.7 × 103 A/W was achieved under 7 µW/cm2 UV (λ = 365 nm) illumination at a 10 V bias voltage, which is much higher than those of commercial UV photodetectors. Additionally, by taking advantage of its anisotropic geometry, we found the TiO2 nanowire array showed polarized photodetection. The concept of using nanomaterial systems shows the potential for realization of nanostructured photodetectors for practical applications.
RESUMO
Background: The causes of atrioventricular block (AVB) are different and diverse young patients, as compared to the old. However, little is known about the etiology distribution and clinical characteristics of AVB in the young group. Methods: We retrospectively analyzed clinical information for AVB patients under 50 years of age. We summarized clinical phenotypes for patients with undetermined AVB etiology, according to AVB type and cardiac-structural change, whereas those who received pacing therapy were followed up for suspected heart failure events (HFEs). Results: AVB etiology was identified in only 289 (61.4%) patients, while 38.6% still have undertermined etiology for AVB. Non-ischemic cardiomyopathy (16.6%) and complication of cardiac surgery (13.4%) were the top two etiologies. In addition, four distinct phenotypes were identified in AVB patients with undetermined etiology, of which the severe phenotype (both borderline/elevated left ventricular diameter or abnormal left ventricular ejection fraction and advanced AVB) accounted for 17%. Notably, 80.7% of patients with severe phenotype received pacing therapy. Based on a median follow-up time of 17.5 months, we found the occurrence of 16 suspected HFEs in 110 pacemaker receivers (12 were lost to follow up). Notably, the severe phenotype was associated with a higher risk of heart failure (HF) symptoms. Conclusions: AVB etiology in young patients under 50 years of age is complex and underdiagnosed. In patients with undetermined etiology, severe phenotype featuring advanced AVB and abnormal Left ventricle (LV) structure/function is associated with a higher rate of HF symptoms even after pacing therapy.
RESUMO
AIMS: The present study was to evaluate the feasibility and clinical outcomes of left bundle branch area pacing (LBBAP) in cardiac resynchronization therapy (CRT)-indicated patients. METHODS AND RESULTS: LBBAP was performed via transventricular septal approach in 25 patients as a rescue strategy in 5 patients with failed left ventricular (LV) lead placement and as a primary strategy in the remaining 20 patients. Pacing parameters, procedural characteristics, electrocardiographic, and echocardiographic data were assessed at implantation and follow-up. Of 25 enrolled CRT-indicated patients, 14 had left bundle branch block (LBBB, 56.0%), 3 right bundle branch block (RBBB, 12.0%), 4 intraventricular conduction delay (IVCD, 16.0%), and 4 ventricular pacing dependence (16.0%). The QRS duration (QRSd) was significantly shortened by LBBAP (intrinsic 163.6 ± 29.4 ms vs. LBBAP 123.0 ± 10.8 ms, P < 0.001). During the mean follow-up of 9.1 months, New York Heart Association functional class was improved to 1.4 ± 0.6 from baseline 2.6 ± 0.6 (P < 0.001), left ventricular ejection fraction (LVEF) increased to 46.9 ± 10.2% from baseline 35.2 ± 7.0% (P < 0.001), and LV end-diastolic dimensions (LVEDD) decreased to 56.8 ± 9.7 mm from baseline 64.1 ± 9.9 mm (P < 0.001). There was a significant improvement (34.1 ± 7.4% vs. 50.0 ± 12.2%, P < 0.001) in LVEF in patients with LBBB. CONCLUSION: The present study demonstrates the clinical feasibility of LBBAP in CRT-indicated patients. Left bundle branch area pacing generated narrow QRSd and led to reversal remodelling of LV with improvement in cardiac function. LBBAP may be an alternative to CRT in patients with failure of LV lead placement and a first-line option in selected patients such as those with LBBB and heart failure.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Eletrocardiografia , Estudos de Viabilidade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Volume Sistólico , Resultado do Tratamento , Função Ventricular EsquerdaRESUMO
The surface modification of LEDs based on GaAs is realized by super-aligned multiwalled carbon nanotube (SACNT) networks as etching masks. The surface morphology of SACNT networks is transferred to the GaAs. It is found that the light output power of LEDs based on GaAs with a nanostructured surface morphology is greatly enhanced with the electrical power unchanged.
RESUMO
Raman spectroscopy has been an integral part of graphene research and can provide information about graphene structure, electronic characteristics, and electron-phonon interactions. In this study, the characteristics of the graphene Raman D-band, which vary with carrier density, are studied in detail, including the frequency, full width half-maximum, and intensity. We find the Raman D-band frequency increases for hole doping and decreases for electron doping. The Raman D-band intensity increases when the Fermi level approaches half of the excitation energy and is higher in the case of electron doping than that of hole doping. These variations can be explained by electron-phonon interaction theory and quantum interference between different Raman pathways in graphene. The intensity ratio of Raman D- and G-band, which is important for defects characterization in graphene, shows a strong dependence on carrier density.
Assuntos
Elétrons , Grafite/química , Nanoestruturas/química , Luz , Fônons , Análise Espectral RamanRESUMO
A multilayered metallic M-shaped nano-grating is proposed to enhance the internal quantum efficiency, light extraction efficiency and surface-plasmon (SP) extraction efficiency of the gallium nitride-based light emitting diodes. This structure is fabricated by the low-cost nano-imprint lithography. The suitable grating based on quasi-symmetrical-waveguide structure has a high transmission in the visible region. The properties of SP mode and the Purcell effect in this type of LED is investigated. The experimental results demonstrate that its peak photoluminescence intensity of the proposed LED is over 10 times greater than that from a naked GaN-LED without any nanostructure.
RESUMO
This study aimed to assess the early and mid-term results of the modified Doty's technique compared with the traditional Doty's technique in patients with congenital supravalvular aortic stenosis (SVAS). We retrospectively included 73 consecutive SVAS patients in Beijing and Yunnan Fuwai Hospitals between 2014 and 2021. Patients were divided into the modified technique (n = 9) and the traditional technique group (n = 64). The modified technique involves altering the right head of the symmetrical inverted pantaloon-shaped patch into an asymmetrical triangular form to prevent compression of the right coronary artery ostium. The primary safety outcome was in-hospital surgery-related complications and the primary effectiveness outcome was re-operation at follow-up. The Mann-Whitney U test and Fisher's exact test were used to test the group difference. The median age at operation was 50 months (IQR 27.0-96.0). Twenty-two (30.1%) of the patients were female. The median follow-up was 23.5 months (IQR 3.0-46.0). No in-hospital surgery-related complications and follow-up re-operation occurred in the modified technique group, but the traditional technique group had 14 (21.8%) surgery-related complications and 5 (7.9%) re-operation. Patients with the modified technique had a well-developed aortic root and no aortic regurgitation occurred. A modified technique could be considered for patients with poor aortic root development to reduce postoperative surgery-related complications.
RESUMO
Leadless pacemakers with an atrioventricular synchrony algorithm represent a novel technology for patients qualified for VDD pacing. The current evidence of their performance is limited to several small-scale observational studies. This systematic review and meta-analysis aimed to evaluate the efficacy and safety of this new technology. We systematically searched the PubMed, Embase, and Cochrane library databases from their inception to 12 September 2022. The primary efficacy outcome was atrioventricular synchrony after implantation, whereas the secondary efficacy outcome was the change in cardiac output represented by the left ventricular outflow tract velocity time integral (LVOT-VTI). The primary safety outcome was major complications related to the procedures and the algorithm. Means or mean differences with 95% confidence interval (95% CI) were combined using a random-effects model or a fixed-effects model. Finally, 8 published studies with 464 participants were included in the qualitative analysis. The pooled atrioventricular synchrony proportion was 78.9% (95% CI 71.9-86.0%), and a further meta-regression did not screen factors that contributed significantly to the heterogeneity. Additionally, a significant increase in atrioventricular synchrony of 11.3% (95% CI 7.0-15.7%, p < 0.01) was achieved in patients experiencing programming optimization. LVOT-VTI was significantly increased by 1.9 cm (95% CI 1.2-2.6, p < 0.01), compared with the VVI pacing mode. The overall incidence of complications was approximately 6.3%, with major complications related to the algorithm being extremely low. Overall, leadless pacemakers with atrioventricular synchronous pacing demonstrated favorable safety and efficacy. Future data on their long-term performance are required to facilitate their widespread adoption in clinical practice.
RESUMO
The study aimed to determine the effectiveness and safety of anomalous coronary artery from pulmonary artery (ACAPA) patients with moderate or severe mitral valve regurgitation (MVR) receiving mitral valve plasty (MVP) concurrently. Consecutive ACAPA patients undergoing surgery between 2015 and 2021 were retrospectively included. Patients were divided into three groups: moderate MVR without MVP (non-MVP (moderate) N = 14), moderate MVR with MVP (MVP (moderate) N = 13), and severe MVR with MVP (MVP (severe) N = 13). The primary safety endpoint was in-hospital surgery-related complications. The primary effectiveness outcome was left ventricular ejection function (LVEF) and left ventricular end-diastolic diameter (LVEDD) z-score at 2- and 24-month follow-ups. Multivariable linear regression models were used to obtain the ß coefficient. The median age of the included patients was 7.5 years (IQR 1.4-26.5). The in-hospital surgery-related complication rates were 7.1%, 15.4%, and 7.7% in non-MVP (moderate), MVP (moderate), and MVP (severe) groups, separately. At the 2-month follow-up, the non-MVP (moderate) group had a better LVEF and LVEDD z-score compared with the MVP (moderate) group (LVEF ß = 9.22, 95%CI 1.09 to 17.35; LVEDD z-score ß = -2.49, 95%CI -4.53 to -0.45). At the 24-month follow-up, the LVEF of all patients and the LVEDD z-score of 90% of patients in the three groups returned to normal. For ACAPA patients with moderate MVR, MVP was not necessary, especially for pediatric patients (age < 3 years) and patients with secondary MVR. Further studies for ACAPA patients with severe MVR are still needed.
RESUMO
Significant enhancement in the light output from GaN-based green light-emitting diodes (LEDs) was achieved with a hemicylindrical grating structure on the top layer of the diodes. The grating structure was first optimized by the finite-difference time-domain (FDTD) method, which showed that the profile of the grating structure was critical for light extraction efficiency. It was found that the transmission efficiency of the 530 nm light emitted from the inside of the GaN LED increased for incidence angles between 23.58° and 60°. Such a structure was fabricated by electron-beam lithography and an etching method. The light output power from the LED was increased approximately 4.7 times compared with that from a conventional LED. The structure optimization is the key to the great increase in transmission efficiency. Furthermore, the light emitted from the edge of the LED units could be collected and extracted by the grating structures in adjacent LED units, thus enhancing the performance of the whole LED chip.
RESUMO
A much stronger interfacial gating effect was observed in the graphene/HfO2/Si photodetector when compared with that in the graphene/SiO2/Si photodetector. We found that this improvement was due to the higher interface state density at the HfO2/Si interface and the higher dielectric constant of the HfO2 layer. The photoresponsivity of the graphene/HfO2/Si photodetector is as high as 45.8 A W-1. Germanium and amorphous MoS2 (a-MoS2) were used to prepare graphene/HfO2/Ge and graphene/HfO2/a-MoS2 photodetectors, further demonstrating the high efficiency of the interfacial gating mechanism for photodetection. Because of the 0.196 eV bandgap of a-MoS2, which was verified in our previous report, the graphene/HfO2/a-MoS2 photodetector realized ultrabroadband photodetection over the range from 473 nm (visible) to 2712 nm (mid-infrared) at room temperature with photoresponsivity as high as 5.36 A W-1 and response time as fast as 68 µs, which represent significant improvements from the corresponding properties of the pure a-MoS2 photodetectors in our previous report and are comparable with those of state-of-the-art broadband photodetectors. By taking full advantage of the interfacial gating mechanism, a fast response, high photoresponsivity and ultrabroadband photodetection were achieved simultaneously. These interfacial gated graphene photodetectors also offer simple fabrication and full semiconductor process compatibility. The advantages described here indicate that the proposed photodetectors have significant potential for use in electronic and optoelectronic applications and offer a new path toward the development of ultrabroadband photodetectors.
RESUMO
BACKGROUND: Left bundle branch pacing (LBBP) is an emerging physiological pacing modality. However, little is known about pacing at different locations on the left bundle branch (LBB). OBJECTIVE: The purpose of this study was to explore pacing and physiological characteristics associated with different LBBP locations. METHODS: The study included 68 consecutive patients with normal unpaced QRS duration and successful LBBP implantation. Patients were divided into 3 groups according to the paced QRS complex as left bundle branch trunk pacing (LBTP), left posterior fascicular pacing (LPFP), or left anterior fascicular pacing (LAFP). Electrocardiographic (ECG) characteristics, pacing parameters, and fluoroscopic localization were collected and analyzed. RESULTS: There were 17 (25.0%), 35 (51.5%), and 16 (23.5%) patients in the LBTP, LPFP, and LAFP groups, respectively. All subgroups had relatively narrow paced QRS complex (128.6 ± 9.1 ms vs 133.7 ± 11.2 ms vs 134.8 ± 9.6 ms; P = .170), fast left ventricular activation (70.4 ± 9.0 ms vs 70.6 ± 10.2 ms vs 71.0 ± 9.0 ms; P = .986), as well as low and stable pacing thresholds. Delayed right ventricular activation and interventricular dyssynchrony were similar between groups. Fluoroscopic imaging indicated that the lead tip was located most commonly in the basal-middle region of the septum (67.7%), and this was independent of paced QRS morphology group (88.2% vs 57.1% vs 68.8%; P = .106). CONCLUSION: Pacing at different sites of the LBB resulted in similar intraventricular and interventricular electrical synchrony in patients with an intact conduction system. Fluoroscopic imaging alone could not predict specific LBBP paced ECG morphology.
Assuntos
Fascículo Atrioventricular/anatomia & histologia , Bloqueio de Ramo/diagnóstico , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Fluoroscopia/métodos , Frequência Cardíaca/fisiologia , Fascículo Atrioventricular/fisiologia , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/terapia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de TempoRESUMO
Raman spectroscopy was used to investigate the phase transition of n-hexacosane for real-time cooling run. In the cooling process, the n-hexacosane experienced the melt phase --> rotator phase --> monoclinic crystal phase transition. The changes in band intensity and frequency in the CH2 bending, CH2 twisting, skeletal C-C stretching, and CH3 rocking regions were mainly analyzed in order to know the changing sequence and process of these vibrational modes, and to reflect the relationship between these vibrational modes and molecular structure. Besides, the changes in band intensity and frequency revealed both transitions, particularly when using band components related to gauche bonds. Our research shows that Raman spectroscopy is an effective tool to monitor the phase transition of n-alkanes or even long-chain polymers. In addition, by analyzing the Raman peaks in 800-1 500 cm(-1) in the cooling process of n-hexacosane, the temperature range of rotator phase was obtained, proving that Raman spectroscopy can be used to observe the rotator phase occurring during the phase transition of paraffin.
RESUMO
BACKGROUND: Left bundle branch pacing (LBBP) is a technique for conduction system pacing, but it often results in right bundle branch block morphology on the ECG. This study was designed to assess simultaneous pacing of the left and right bundle branch areas to achieve more synchronous ventricular activation. METHODS: In symptomatic bradycardia patients, the distal electrode of a bipolar pacing lead was placed at the left bundle branch area via a transventricular-septal approach. This was used to pace the left bundle branch area, while the ring electrode was used to pace the right bundle branch area. Bilateral bundle branch area pacing (BBBP) was achieved by stimulating the cathode and anode in various pacing configurations. QRS duration, delayed right ventricular activation time, left ventricular activation time, and interventricular conduction delay were measured. Pacing stability and short-term safety were assessed at 3-month follow-up. RESULTS: BBBP was successfully performed in 22 of 36 patients. Compared with LBBP, BBBP resulted in greater shortening of QRS duration (109.3±7.1 versus 118.4±5.7 ms, P<0.001). LBBP resulted in a paced right bundle branch block configuration, with a delayed right ventricular activation time of 115.0±7.5 ms and interventricular conduction delay of 34.0±8.8 ms. BBBP fully resolved the right bundle branch block morphology in 18 patients. In the remaining 4 patients, BBBP partially corrected the right bundle branch block with delayed right ventricular activation time decreasing from 120.5±4.7 ms during LBBP to 106.1±4.2 ms during BBBP (P=0.005). CONCLUSIONS: LBBP results in a relatively narrow QRS complex but with an interventricular activation delay. BBBP can diminish the delayed right ventricular activation, producing more physiological ventricular activation. Graphic Abstract: A graphic abstract is available for this article.
Assuntos
Potenciais de Ação , Bradicardia/terapia , Fascículo Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Frequência Cardíaca , Idoso , Bradicardia/diagnóstico , Bradicardia/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda , Função Ventricular DireitaRESUMO
Raman spectroscopy was used to investigate the order-disorder phase transition of n-eicosane for real-time cooling run. At the phase transition temperature, the integrated intensity of the 1 300 cm(-1) spectra range changes greatly, which requires further consideration of 1 300 cm(-1) as a reference in the research on polymer and biomembrane using Raman spectroscopy. The experiment support was provided for doubt about order parameter based on 1 130 cm(-1) that it did not refer to generally accepted interpretation of an order parameter and it proved that the order definition could just be used as a relative measure method for disorder.
RESUMO
InGaN/GaN, InGaN/InGaN and InGaN/AlInGaN multi-quantum-well (MQW) laser diodes (LDs) were grown on (0001) sapphire substrate by metalorganic chemical vapor deposition (MOCVD). The GaN (0002) synchrotron X-ray diffraction (XRD), electroluminescence (EL) and optical power-current (L-I) measurement reveal that AlInGaN quaternary alloys as barriers in MQWs can improve the crystal quality, optical emission performance, threshold current and slope efficiency of the laser diode structure to a large extent compared with other barriers. The relevant mechanisms are that: 1. The Al component increases the barrier height of the MQWs so that more current carriers will be caught in. 2. The In component counteracts the strain in the MQWs that decreases the dislocations and defects, thereby the nonradiative recombination centers are decreased. 3. The In component decreases the piezoelectric electric field that makes the electrons and the holes recombine more easily.
RESUMO
A high-performance exciton-localized surface plasmon (LSP) coupling system consisting of well-designed plasmonic nanostructures and CdSe/ZnS quantum dots (QDs) was fabricated by first introducing a Ta2O5 layer as both an adhesive coating and coupling medium. It is shown that a larger emission enhancement factor of 6 from CdSe/ZnS QDs can be obtained from the strong coupling effect between QDs and triprism Au nanoarrays and the high scattering efficiency of LSPs without damping. This can be attributed to the matching conditions and a low extinction coefficient with little damping absorption of the Ta2O5 layer in the system. The radiative scattering rate of ΓLSPs can make a contribution to the spontaneous emission rate Γ and thus improve the internal quantum yield of the QDs. This strategy could be promising for practical application of metal-modified fluorescence enhancement.
RESUMO
Transition-metal dichalcogenides are promising challengers to conventional semiconductors owing to their remarkable electrical performance and suppression of short-channel effects (SCEs). In particular, monolayer molybdenum disulfide has exhibited superior suppression of SCEs owing to its atomic thickness, high effective carrier mass, and low dielectric constant. However, difficulties still remain in large-scale stable fabrication of nanometer-scale channels. Herein, a method to fabricate electrodes with sub-10 nm gaps was demonstrated using horizontally aligned single-walled carbon nanotubes as an evaporation mask. The widths of the nanogaps exhibit robust stability to various process parameters according to the statistical results. Based on these nanogaps, ultrashort-channel length monolayer MoS2 field-effect transistors were produced. Monolayer MoS2 devices with a 7.5 nm channel length and a 10 nm thick HfO2 dielectric layer exhibited excellent performances with an ON/OFF ratio up to 107, a mobility of 17.4 cm2/V·s, a subthreshold swing of about 120 mV/dec, and a drain-induced barrier lowering of about 140 mV/V, all of which suggest a superior suppression of SCEs. This work provides a universal and stable method for large-scale fabrication of ultrashort-channel 2D-material transistors.
RESUMO
Raman spectra of ZnO powders prepared by firing ZnO2 precipitate were reported in detail for the first time. By comparing the spectra with that of the sample fabricated by another method and analyzing frequency difference between the focused-laser irradiated samples with different firing temperature in preparation, it was concluded that the -333 cm(-1) peak is ascribed to E2 (high)-E2 (low) and the -661 cm(-1) peak to its overtone. In addition, a new interpretation for the observed Raman peaks between 400 and 500 cm(-1) in ZnO2 powders was presented based on the IR data and ab initio calculation.
RESUMO
A flexible and transparent film assembled from the cross-nanoporous structures of Au on PET (CNS of Au@PET) is developed as a versatile and effective SERS substrate for rapid, on-site trace analysis with high sensitivity. The fabrication of the CNS of Au can be achieved on a large scale at low cost by employing an etching process with super-aligned carbon nanotubes as a mask, followed by metal deposition. A strongly enhanced Raman signal with good uniformity can be obtained, which is attributed to the excitation of "hot spots" around the metal nanogaps and sharp edges. Using the CNS of Au@PET film as a SERS platform, real-time and on-site SERS detection of the food contaminant crystal violet (CV) is achieved, with a detection limit of CV solution on a tomato skin of 10-7 M. Owing to its ability to efficiently extract trace analytes, the resulting substrate also achieves detection of 4-ATP contaminants and thiram pesticides by swabbing the skin of an apple. A SERS detection signal for 4-ATP has a relative standard deviation of less than 10%, revealing the excellent reproducibility of the substrate. The flexible, transparent and highly sensitive substrates fabricated using this simple and cost-effective strategy are promising for practical application in rapid, on-site SERS-based detection.