Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Europace ; 14(2): 249-53, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21933798

RESUMO

AIMS: It is not clear whether cardiac resynchronization therapy (CRT) should only be optimized at rest or whether it is necessary to perform CRT optimization during exercise. Our study aims to answer this question by using an inert gas rebreathing method (Innocor®). METHODS AND RESULTS: Twenty-seven patients with congestive heart failure and implanted CRT devices were included in the study. The aetiology of the heart failure was ischaemic in nine (33%) patients. Patients had low left ventricular ejection fraction (29 ± 8%) and enlarged LV end-diastolic diameters (63 ± 7 mm). Atrioventricular delay (AVD) was optimized at rest according to cardiac index (CI), measured by inert gas rebreathing (Innocor®). Thereafter, patients performed standardized, steady-state bicycle exercise at 30 W in sitting body position. Three AVDs were tested during exercise in a random sequence: optimized resting AVD (AVD(opt)) according to baseline measurement; AVD(opt) - 30 ms; and AVD(opt) + 30 ms. Cardiac index was measured in each AVD by inert gas rebreathing. Cardiac index increased significantly during exercise. However, neither AVD(opt) shortening nor prolongation during exercise had significant effect on CI (shortening of AVD(opt) - 30 ms was accompanied by a reduction of CI of 4.8%, prolongation of AVD(opt) + 30 ms was accompanied by a reduction of CI of 7.7%). CONCLUSION: Shortening or lengthening of the AVD during exercise has no impact on CI in CRT patients. On the basis of our results, we conclude that in CRT patients the AVD should be programmed, fixed even during exercise.


Assuntos
Testes Respiratórios/instrumentação , Diagnóstico por Computador/instrumentação , Teste de Esforço/métodos , Indicadores Básicos de Saúde , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Terapia Assistida por Computador/instrumentação , Idoso , Terapia de Ressincronização Cardíaca , Diagnóstico por Computador/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Terapia Assistida por Computador/métodos , Resultado do Tratamento
2.
J Electrocardiol ; 45(2): 161-3, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21741661

RESUMO

Myocarditis is an injury of the myocardium caused by a variety of agents. Conduction disturbances such as complete atrioventricular block (AV block) may occur as an infrequent but serious complication of myocarditis. Early detection and accurate diagnosis of myocarditis are still unresolved challenges. We present 2 cases of otherwise mild myocarditis complicated by high-degree AV block in combination with isolated delayed uptake of contrast at the septal regions in the cardiac magnetic resonance imaging. Because the AV block was persistent in both cases, permanent pacemaker implantation was necessary. Delayed enhancement in the septal area in myocarditis might be predictive of infra-Hisian AV block.


Assuntos
Bloqueio Atrioventricular/diagnóstico , Imageamento por Ressonância Magnética/métodos , Miocardite/diagnóstico , Adulto , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/cirurgia , Biomarcadores/sangue , Biópsia , Meios de Contraste , Diagnóstico Diferencial , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Masculino , Miocardite/complicações , Marca-Passo Artificial
3.
Biomed Tech (Berl) ; 52(2): 173-9, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17408376

RESUMO

INTRODUCTION: Biventricular (BV) pacing is an established therapy for heart failure (HF) patients with intraventricular conduction delay, but not all patients improved clinically. We investigated the interventricular delay (IVD) by means of the transesophageal left ventricular posterior wall potential (LVPWP). MATERIALS AND METHODS, AND RESULTS: A total of 18 HF patients (age 62+/-9 years; 15 males) with NYHA class 3.1+/-0.3, LV ejection fraction 22+/-7%, left bundle branch block and a QRS duration (QRSD) of 171+/-27 ms were analyzed using transesophageal LVPWP before implantation of a BV pacing device. The median follow up was 14+/-14 months. In 14 responders, IVD was 81+/-25 ms with a QRSD/IVD ratio of 2.2+/-0.3 with reclassification of NYHA class 3.1+/-0.3 to 2.0+/-0.5 (p<0.001) and an increase in LV ejection fraction from 22+/-7% to 36+/-11% (p=0.001) during long-term BV pacing. In four non-responders, transesophageal IVD was significantly smaller at 30+/-11 ms (p=0.001). CONCLUSION: Transesophageal IVD may be a useful method to detect responders to BV pacing. Transesophageal LVPWP may be a simple and useful technique to detect clinical responders to BV pacing in HF patients.


Assuntos
Baixo Débito Cardíaco/prevenção & controle , Baixo Débito Cardíaco/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Baixo Débito Cardíaco/complicações , Baixo Débito Cardíaco/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/etiologia
4.
Biomed Tech (Berl) ; 52(2): 180-4, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17408377

RESUMO

INTRODUCTION: The purpose of this study was to evaluate termination of atrial flutter (AFL) by directed rapid transesophageal atrial pacing (TAP) with and without simultaneous transesophageal echocardiography (TEE) performed using a novel TEE tube electrode. MATERIALS AND METHODS, AND RESULTS: A total of 16 AFL patients (age 63+/-12 years; 13 males) with mean AFL cycle length of 224+/-24 ms (n=12) and mean ventricular cycle length of 448+/-47 ms (n=12) were analyzed using either an esophageal TO electrode (n=10) or a novel TEE tube electrode consisting of a tube with four hemispherical electrodes that is pulled over the echo probe (n=6). AFL could be terminated by directed rapid TAP using an esophageal TO electrode, leading to induction of atrial fibrillation (AF) (n=6), induction of AF and spontaneous conversion to sinus rhythm (SR) (n=3), and with conversion to SR (n=1). AFL could also be terminated by directed rapid TAP using the TEE tube electrode, with induction of AF (n=3) or induction of AF and spontaneous conversion to SR (n=3). CONCLUSION: AFL can be terminated by directed rapid TAP with hemispherical electrodes with and without simultaneous TEE. TAP with the directed TEE tube electrode is a safe, simple, and useful method for terminating AFL.


Assuntos
Flutter Atrial/diagnóstico por imagem , Flutter Atrial/prevenção & controle , Ecocardiografia Transesofagiana/métodos , Eletrodos Implantados , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
5.
Cardiovasc Toxicol ; 15(4): 399-401, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25588686

RESUMO

A 77-year-old female patient with symptomatic atrial fibrillation with fast ventricular rate despite conventional antiarrhythmic therapy was treated with dronedarone. Five days later, she developed a maculopapulous exanthema and small flaccid blisters, which spread over the common integument predominantly located on the dorsal trunk. Over few days, the patient showed a severe epidermal necrolysis of approximately 30 % of the body area and ultimately died in multiorgan failure. Here, we report a rare case of toxic epidermal necrolysis during treatment with dronedarone leading to patient death.


Assuntos
Amiodarona/análogos & derivados , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Frequência Cardíaca/efeitos dos fármacos , Síndrome de Stevens-Johnson/etiologia , Idoso , Amiodarona/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Biópsia , Dronedarona , Evolução Fatal , Feminino , Humanos , Insuficiência de Múltiplos Órgãos/induzido quimicamente , Índice de Gravidade de Doença , Síndrome de Stevens-Johnson/diagnóstico , Fatores de Tempo
6.
J Interv Card Electrophysiol ; 6(2): 161-4, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11992026

RESUMO

The only inducible arrhythmia in a patient with exclusive antegrade conducting left anterolateral accessory pathway, consists of slow/fast atrioventricular nodal reentrant tachycardia. After radiofrequency catheter ablation of the slow pathway, true antidromic AV reentrant tachycardia was easily induced by atrial pacing. Following ablation of the accessory pathway no arrhythmia could be induced.


Assuntos
Ablação por Cateter , Sistema de Condução Cardíaco/anormalidades , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/terapia , Adulto , Eletrocardiografia , Feminino , Humanos , Síndrome de Wolff-Parkinson-White/fisiopatologia
7.
Med Biol Eng Comput ; 49(8): 851-8, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21448690

RESUMO

Cardiac resynchronization therapy (CRT) with biventricular pacing (BV) is an established therapy for heart failure (HF) patients with inter- and intraventricular conduction delay. The aim of this pilot study was to test the feasibility of both transesophageal measurement of left ventricular (LV) electrical delay and transesophageal LV pacing prior to implantation, to better select patients for CRT. Esophageal TO8 Osypka catheter was perorally applied in 30 HF patients in position of maximum LV deflection to measure LV electrical delay and to study arterial pulse pressure (PP) during transesophageal bipolar LV pacing. There were 15 responders with a PP increase of a mean 65 ± 24 mmHg to 79 ± 27 mmHg (P < 0.001) and a mean LV electrical delay of 86.8 ± 33 ms. The 15 non-responders with poor PP increase of a mean 63.5 ± 23.5 mmHg to 64.1 ± 23.9 mmHg (P = 0.065) had a significantly smaller LV electrical delay of 36 ± 21 ms (P < 0.001). During a 34 ± 26 month CRT follow-up, the responders New York Heart Association (NYHA) class improved from 3.1 ± 0.35 to 2.1 ± 0.35 (P < 0.001). Determination of left ventricular electrical delay by transesophageal electrogram recording and transesophageal left ventricular pacing may be additional useful techniques to improve patient selection for CRT.


Assuntos
Estimulação Cardíaca Artificial/métodos , Insuficiência Cardíaca/terapia , Adulto , Idoso , Pressão Sanguínea/fisiologia , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Projetos Piloto
8.
Europace ; 7(6): 617-20, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16216766

RESUMO

BACKGROUND: Previous studies of biventricular (BV) pacing for treatment of heart failure (HF) patients with left bundle branch block (LBBB) evaluated responders to BV pacing with acute transvenous left ventricular (LV) pacing and arterial pulse pressure (PP). The aim of this study was to assess transoesophageal LV pacing in evaluation of the haemodynamic response with a view to upgrading responders from permanent right ventricular (RV) pacing to BV pacing. METHODS AND RESULTS: Ten HF patients (age 62+/-8 years; one female, nine males) in NYHA III, LV ejection fraction 24+/-9% and permanent RV pacing by means of an implanted pacemaker or ICD were tested using transoesophageal LV pacing and PP. Permanently RV-paced HF patients were analysed with transoesophageal atrial sensed LV pacing in VAT mode with a different AV delay (n = 6) and with transoesophageal LV pacing in V00 mode during atrial fibrillation (n = 4). In five responders, PP was higher during transoesophageal LV pacing than PP during RV pacing (74+/-42 versus 57+/-31 mmHg, P = 0.015). Responders were upgraded by means of an LV lead via the coronary sinus in the posterior (n = 1) or posterolateral (n = 4) walls and after attaining a high LV pacing threshold with an epicardial LV lead on the anterior (n = 1) or anterolateral (n = 1) walls. NYHA class improved from 3 to 2+/-0.3 (P = 0.003) during 204+/-120 days follow-up and cardiac output increased from 4.4+/-1.5 to 5.6+/-1.7 l/min (P = 0.027) when comparing BV pacing and optimal AV delay with RV pacing. In five nonresponders, PP was not higher during transoesophageal LV pacing than during RV pacing. CONCLUSION: Transoesophageal LV pacing may be a useful technique to detect responders to BV pacing in permanently RV-paced HF patients.


Assuntos
Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Insuficiência Cardíaca/complicações , Marca-Passo Artificial , Bloqueio de Ramo/complicações , Bloqueio de Ramo/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa