Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
1.
PLoS Biol ; 18(11): e3000902, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33201874

RESUMO

Coordinated development of muscles, tendons, and their attachment sites ensures emergence of functional musculoskeletal units that are adapted to diverse anatomical demands among different species. How these different tissues are patterned and functionally assembled during embryogenesis is poorly understood. Here, we investigated the morphogenesis of extraocular muscles (EOMs), an evolutionary conserved cranial muscle group that is crucial for the coordinated movement of the eyeballs and for visual acuity. By means of lineage analysis, we redefined the cellular origins of periocular connective tissues interacting with the EOMs, which do not arise exclusively from neural crest mesenchyme as previously thought. Using 3D imaging approaches, we established an integrative blueprint for the EOM functional unit. By doing so, we identified a developmental time window in which individual EOMs emerge from a unique muscle anlage and establish insertions in the sclera, which sets these muscles apart from classical muscle-to-bone type of insertions. Further, we demonstrate that the eyeballs are a source of diffusible all-trans retinoic acid (ATRA) that allow their targeting by the EOMs in a temporal and dose-dependent manner. Using genetically modified mice and inhibitor treatments, we find that endogenous local variations in the concentration of retinoids contribute to the establishment of tendon condensations and attachment sites that precede the initiation of muscle patterning. Collectively, our results highlight how global and site-specific programs are deployed for the assembly of muscle functional units with precise definition of muscle shapes and topographical wiring of their tendon attachments.


Assuntos
Músculos Oculomotores/embriologia , Músculos Oculomotores/crescimento & desenvolvimento , Tretinoína/metabolismo , Animais , Tecido Conjuntivo/fisiologia , Desenvolvimento Embrionário , Olho , Imageamento Tridimensional/métodos , Camundongos/embriologia , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos DBA , Morfogênese , Transdução de Sinais , Tendões/fisiologia , Tretinoína/fisiologia
2.
Cell Mol Life Sci ; 78(16): 6033-6049, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34274976

RESUMO

Melanocytes are pigmented cells residing mostly in the skin and hair follicles of vertebrates, where they contribute to colouration and protection against UV-B radiation. However, the spectrum of their functions reaches far beyond that. For instance, these pigment-producing cells are found inside the inner ear, where they contribute to the hearing function, and in the heart, where they are involved in the electrical conductivity and support the stiffness of cardiac valves. The embryonic origin of such extracutaneous melanocytes is not clear. We took advantage of lineage-tracing experiments combined with 3D visualizations and gene knockout strategies to address this long-standing question. We revealed that Schwann cell precursors are recruited from the local innervation during embryonic development and give rise to extracutaneous melanocytes in the heart, brain meninges, inner ear, and other locations. In embryos with a knockout of the EdnrB receptor, a condition imitating Waardenburg syndrome, we observed only nerve-associated melanoblasts, which failed to detach from the nerves and to enter the inner ear. Finally, we looked into the evolutionary aspects of extracutaneous melanocytes and found that pigment cells are associated mainly with nerves and blood vessels in amphibians and fish. This new knowledge of the nerve-dependent origin of extracutaneous pigment cells might be directly relevant to the formation of extracutaneous melanoma in humans.


Assuntos
Encéfalo/fisiologia , Orelha Interna/fisiologia , Coração/fisiologia , Meninges/fisiologia , Sistema Nervoso/fisiopatologia , Células de Schwann/fisiologia , Anfíbios/metabolismo , Anfíbios/fisiologia , Animais , Encéfalo/metabolismo , Linhagem da Célula/fisiologia , Orelha Interna/metabolismo , Desenvolvimento Embrionário/fisiologia , Feminino , Peixes/metabolismo , Peixes/fisiologia , Melanócitos/metabolismo , Melanócitos/fisiologia , Meninges/metabolismo , Camundongos , Sistema Nervoso/metabolismo , Gravidez , Receptor de Endotelina B/metabolismo , Células de Schwann/metabolismo
3.
Analyst ; 146(3): 920-929, 2021 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-33241792

RESUMO

Ablation geometry significantly affects the plasma parameters and the consequent spectroscopic observations in laser-induced breakdown spectroscopy. Nevertheless, plasmas induced by laser ablation under inclined incidence angles are studied to a significantly lesser extent compared to plasmas induced by standard orthogonal ablation. However, inclined ablation is prominent in stand-off applications, such as the Curiosity Mars rover, where the orthogonality of the ablation laser pulse cannot be always secured. Thus, in this work, we characterize non-orthogonal ablation plasmas by applying plasma imaging, tomography, and spectral measurements. We confirm earlier observations according to which non-orthogonal ablation leads to a laser-induced plasma that consists of two distinct parts: one expanding primarily along the incident laser pulse and one expanding along the normal of the sample surface. Moreover, we confirm that the former emits mainly continuum radiation, while the latter emits mainly sample-specific characteristic radiation. We further investigate and compare the homogeneity of the plasmas and report that inclined ablation affects principally the ionic emissivity of laser-induced plasmas. Overall, our results imply that the decreased fluence resulting from inclined angle ablation and the resulting inhomogeneities of the plasmas must be considered for quantitative LIBS employing non-orthogonal ablation.

4.
Ecotoxicol Environ Saf ; 214: 112113, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33690006

RESUMO

The main purpose of this work is to thoroughly describe the implementation protocol of laser-induced breakdown spectroscopy (LIBS) method in the plant analysis. Numerous feasibility studies and recent progress in instrumentation and trends in chemical analysis make LIBS an established method in plant bioimaging. In this work, we present an easy and straightforward phytotoxicity case study with a focus on LIBS method. We intend to demonstrate in detail how to manipulate with plants after exposures and how to prepare them for analyses. Moreover, we aim to achieve 2D maps of spatial element distribution with a good resolution without any loss of sensitivity. The benefits of rapid, low-cost bioimaging are highlighted. In this study, cabbage (Brassica oleracea L.) was treated with an aqueous dispersion of photon-upconversion nanoparticles (NaYF4 doped with Yb3+ and Tm3+ coated with carboxylated silica shell) in a hydroponic short-term toxicity test. After a 72-hour plant exposure, several macroscopic toxicity end-points were monitored. The translocation of Y, Yb, and Tm across the whole plant was set by employing LIBS with a lateral resolution 100 µm. The LIBS maps of rare-earth elements in B.oleracea plant grown with 50 µg/mL nanoparticle-treated and ion-treated exposures showed the root as the main storage, while the transfer via stem into leaves was minimal. On the contrary, the LIBS maps of plants exposed to the 500 µg/mL nanoparticle-treated and ion-treated uncover slightly different trends, nanoparticles as well as ions were transferred through the stem into leaves. However, the main storage organ was a root as well.


Assuntos
Brassica/metabolismo , Fluoretos/administração & dosagem , Nanopartículas/administração & dosagem , Dióxido de Silício/administração & dosagem , Túlio/toxicidade , Itérbio/administração & dosagem , Ítrio/administração & dosagem , Lasers , Folhas de Planta/metabolismo , Raízes de Plantas/metabolismo , Caules de Planta/metabolismo , Análise Espectral
5.
Mikrochim Acta ; 188(5): 147, 2021 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-33797618

RESUMO

Immunohistochemistry (IHC) and immunocytochemistry (ICC) are widely used to identify cancerous cells within tissues and cell cultures. Even though the optical microscopy evaluation is considered the gold standard, the limited range of useful labels and narrow multiplexing capabilities create an imminent need for alternative readout techniques. Laser-induced breakdown spectroscopy (LIBS) enables large-scale multi-elemental analysis of the surface of biological samples, e.g., thin section or cell pellet. It is, therefore, a potential alternative for IHC and ICC readout of various labels or tags (Tag-LIBS approach). Here, we introduce Tag-LIBS as a method for the specific determination of HER2 biomarker. The cell pellets were labeled with streptavidin-conjugated upconversion nanoparticles (UCNP) through a primary anti-HER2 antibody and a biotinylated secondary antibody. The LIBS scanning enabled detecting the characteristic elemental signature of yttrium as a principal constituent of UCNP, thus indirectly providing a reliable way to differentiate between HER2-positive BT-474 cells and HER2-negative MDA-MB-231 cells. The comparison of results with upconversion optical microscopy and luminescence intensity scanning confirmed that LIBS is a promising alternative for the IHC and ICC readout.


Assuntos
Biomarcadores Tumorais/análise , Nanopartículas/química , Receptor ErbB-2/análise , Anticorpos Imobilizados/imunologia , Biomarcadores Tumorais/imunologia , Linhagem Celular Tumoral , Estudos de Viabilidade , Fluoretos/química , Fluoretos/efeitos da radiação , Humanos , Imuno-Histoquímica/métodos , Luz , Nanopartículas/efeitos da radiação , Receptor ErbB-2/imunologia , Análise Espectral/métodos , Túlio/química , Túlio/efeitos da radiação , Ítrio/química , Ítrio/efeitos da radiação
6.
Sensors (Basel) ; 21(1)2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33401506

RESUMO

In this article, we introduce a new ring artifacts reduction procedure that combines several ideas from existing methods into one complex and robust approach with a goal to overcome their individual weaknesses and limitations. The procedure differentiates two types of ring artifacts according to their cause and character in computed tomography (CT) data. Each type is then addressed separately in the sinogram domain. The novel iterative schemes based on relative total variations (RTV) were integrated to detect the artifacts. The correction process uses the image inpainting, and the intensity deviations smoothing method. The procedure was implemented in scope of lab-based X-ray nano CT with detection systems based on charge-coupled device (CCD) and scientific complementary metal-oxide-semiconductor (sCMOS) technologies. The procedure was then further tested and optimized on the simulated data and the real CT data of selected samples with different compositions. The performance of the procedure was quantitatively evaluated in terms of the artifacts' detection accuracy, the comparison with existing methods, and the ability to preserve spatial resolution. The results show a high efficiency of ring removal and the preservation of the original sample's structure.


Assuntos
Artefatos , Processamento de Imagem Assistida por Computador , Algoritmos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Raios X
7.
Sensors (Basel) ; 21(3)2021 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-33572796

RESUMO

The improving performance of the laser-induced breakdown spectroscopy (LIBS) triggered its utilization in the challenging topic of soft tissue analysis. Alterations of elemental content within soft tissues are commonly assessed and provide further insights in biological research. However, the laser ablation of soft tissues is a complex issue and demands a priori optimization, which is not straightforward in respect to a typical LIBS experiment. Here, we focus on implementing an internal standard into the LIBS elemental analysis of soft tissue samples. We achieve this by extending routine methodology for optimization of soft tissues analysis with a standard spiking method. This step enables a robust optimization procedure of LIBS experimental settings. Considering the implementation of LIBS analysis to the histological routine, we avoid further alterations of the tissue structure. Therefore, we propose a unique methodology of sample preparation, analysis, and subsequent data treatment, which enables the comparison of signal response from heterogenous matrix for different LIBS parameters. Additionally, a brief step-by-step process of optimization to achieve the highest signal-to-noise ratio (SNR) is described. The quality of laser-tissue interaction is investigated on the basis of the zinc signal response, while selected experimental parameters (e.g., defocus, gate delay, laser energy, and ambient atmosphere) are systematically modified.


Assuntos
Terapia a Laser , Lasers , Células , Luz , Padrões de Referência , Análise Espectral
8.
Dev Dyn ; 249(4): 441-464, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31762125

RESUMO

BACKGROUND: In mammals, odontogenesis is regulated by transient signaling centers known as enamel knots (EKs), which drive the dental epithelium shaping. However, the developmental mechanisms contributing to formation of complex tooth shape in reptiles are not fully understood. Here, we aim to elucidate whether signaling organizers similar to EKs appear during reptilian odontogenesis and how enamel ridges are formed. RESULTS: Morphological structures resembling the mammalian EK were found during reptile odontogenesis. Similar to mammalian primary EKs, they exhibit the presence of apoptotic cells and no proliferating cells. Moreover, expression of mammalian EK-specific molecules (SHH, FGF4, and ST14) and GLI2-negative cells were found in reptilian EK-like areas. 3D analysis of the nucleus shape revealed distinct rearrangement of the cells associated with enamel groove formation. This process was associated with ultrastructural changes and lipid droplet accumulation in the cells directly above the forming ridge, accompanied by alteration of membranous molecule expression (Na/K-ATPase) and cytoskeletal rearrangement (F-actin). CONCLUSIONS: The final complex shape of reptilian teeth is orchestrated by a combination of changes in cell signaling, cell shape, and cell rearrangement. All these factors contribute to asymmetry in the inner enamel epithelium development, enamel deposition, ultimately leading to the formation of characteristic enamel ridges.


Assuntos
Répteis/anatomia & histologia , Répteis/crescimento & desenvolvimento , Répteis/metabolismo , Actinas/metabolismo , Animais , Esmalte Dentário/citologia , Esmalte Dentário/metabolismo , Esmalte Dentário/ultraestrutura , Regulação da Expressão Gênica no Desenvolvimento/fisiologia , Gotículas Lipídicas/metabolismo , Microscopia Eletrônica de Transmissão , Odontogênese/fisiologia , Dente
10.
J Aerosol Sci ; 150: 105649, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32904428

RESUMO

The inhalation route has a substantial influence on the fate of inhaled particles. An outbreak of infectious diseases such as COVID-19, influenza or tuberculosis depends on the site of deposition of the inhaled pathogens. But the knowledge of respiratory deposition is important also for occupational safety or targeted delivery of inhaled pharmaceuticals. Simulations utilizing computational fluid dynamics are becoming available to a wide spectrum of users and they can undoubtedly bring detailed predictions of regional deposition of particles. However, if those simulations are to be trusted, they must be validated by experimental data. This article presents simulations and experiments performed on a geometry of airways which is available to other users and thus those results can be used for intercomparison between different research groups. In particular, three hypotheses were tested. First: Oral breathing and combined breathing are equivalent in terms of particle deposition in TB airways, as the pressure resistance of the nasal cavity is so high that the inhaled aerosol flows mostly through the oral cavity in both cases. Second: The influence of the inhalation route (nasal, oral or combined) on the regional distribution of the deposited particles downstream of the trachea is negligible. Third: Simulations can accurately and credibly predict deposition hotspots. The maximum spatial resolution of predicted deposition achievable by current methods was searched for. The simulations were performed using large-eddy simulation, the flow measurements were done by laser Doppler anemometry and the deposition has been measured by positron emission tomography in a realistic replica of human airways. Limitations and sources of uncertainties of the experimental methods were identified. The results confirmed that the high-pressure resistance of the nasal cavity leads to practically identical velocity profiles, even above the glottis for the mouth, and combined mouth and nose breathing. The distribution of deposited particles downstream of the trachea was not influenced by the inhalation route. The carina of the first bifurcation was not among the main deposition hotspots regardless of the inhalation route or flow rate. On the other hand, the deposition hotspots were identified by both CFD and experiments in the second bifurcation in both lungs, and to a lesser extent also in both the third bifurcations in the left lung.

11.
Inorg Chem ; 58(21): 14467-14477, 2019 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-31613608

RESUMO

The physicochemical properties of rare-earth zirconates can be tuned by the rational modification of their structures and phase compositions. In the present work, La3+-, Nd3+-, Gd3+-, and Dy3+-zirconate nanostructured materials were prepared by different synthetic protocols, leading to powders, xerogels, and, for the first time, monolithic aerogels. Powders were synthesized by the co-precipitation method, while xerogels and aerogels were synthesized by the sol-gel technique, followed by ambient and supercritical drying, respectively. Their microstructures, thermogravimetric profiles, textural properties, and crystallographic structures are reported. The co-precipitation method led to dense powders (SBET < 1 m2 g-1), while the sol-gel technique resulted in large surface area xerogels (SBET = 144 m2 g-1) and aerogels (SBET = 168 m2 g-1). In addition, the incorporation of lanthanide ions into the zirconia lattice altered the crystal structures of the powders, xerogels, and aerogels. Single-phase pyrochlores were obtained for La2Zr2O7 and Nd2Zr2O7 powders and xerogels, while defect fluorite structures formed in the case of Gd2Zr2O7 and Dy2Zr2O7. All aerogels contain a mixture of cubic and tetragonal ZrO2 phases. Thus, a direct effect is shown between the drying conditions and the resulting crystalline phases of the nanostructured rare-earth zirconates.

12.
Am J Phys Anthropol ; 170(2): 275-294, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31322736

RESUMO

OBJECTIVES: This article summarized errors obtained by diverse techniques used for the derivation of cross-sectional contours in nonadult humeri and tibiae. MATERIALS AND METHODS: We analyzed cross-sectional contours in a total sample of 62 humeral and 75 tibial diaphyses in the age between birth and 12 years divided into three age groups. Long bone 35% (humeri) and midshaft (tibiae) cross-sections were taken on micro-CT images and analyzed by EPJMacro in FIJI. Properties were extracted from contours derived by manual, automatic, spline, and ellipse techniques. Agreement between techniques was assessed using manually extracted properties such as the true value using percent prediction error (%PE), reduced major axis regression, and ±95% limits of agreement. RESULTS: The lowest measurement errors were obtained for total areas, moderate errors for cortical areas and section moduli, and the highest errors for medullary areas for both bones. Derivation of humeral nonadult cross-sectional properties is less sensitive to the technique used for derivation of periosteal and endosteal contours, reaching mean %PEs below 5%. In contrast, tibial nonadult cross-sectional properties are more sensitive to the technique used and exceed 5% for some combinations. DISCUSSION: Automatic techniques provide reasonably high agreement with manually extracted contours for nonadult humeri but low agreement for tibiae. Semiautomatic approaches-spline and ellipse techniques-may reduce the error for all studied properties in tibiae, especially when combined with manually traced periosteal contours. The positive effect of the semiautomatic technique on measurement error is low for humeri.


Assuntos
Úmero , Periósteo , Tíbia , Anatomia Transversal , Antropologia Física , Antropometria , Criança , Pré-Escolar , Humanos , Úmero/anatomia & histologia , Úmero/diagnóstico por imagem , Lactente , Recém-Nascido , Modelos Estatísticos , Periósteo/anatomia & histologia , Periósteo/diagnóstico por imagem , Reprodutibilidade dos Testes , Tíbia/anatomia & histologia , Tíbia/diagnóstico por imagem , Microtomografia por Raio-X
13.
Mikrochim Acta ; 186(9): 629, 2019 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-31418079

RESUMO

Laser-induced breakdown spectroscopy (LIBS) was examined as a novel method for readout of microtiter plate immunoassays involving nanoparticles (NP). The so-called Tag-LIBS technique is a sensitive method for the detection of specific biomarkers. It was applied to the determination of NP labels using nanosecond ablation sampling. The NP labels were examined from the bottom of a standard 96-well microtiter plate. Thanks to the flexibility of LIBS instrumentation, both the plasma emission collection and the focusing optics arrangements can be collinearly arranged. The experiments showed that silver NPs and gold NPs can be readily quantified on the bottom of the microtiter plate. Utilizing this technique, a sandwich immunoassay for human serum albumin using streptavidin-coated AgNP labels was developed. The assay has a 10 ng·mL-1 detection limit which is comparable to the sensitivity of fluorometric readout. The main advantage of this LIBS technique is its wide scope in which it enables a detection of almost any type of NP labels, irrespective to any fluorescence or catalytic properties. Owing to the immediate signal response, the relatively simple instrumentation also enables assay automation. The LIBS capability of multi-elemental analyses makes it a promising and fast alternative to other readout techniques, in particular with respect to multiplexed detection of biomarkers. Graphical abstract Laser-induced breakdown spectroscopy (LIBS) is used as a novel readout method of nanoparticle-based immunoassays in microtiter plates. After formation of sandwich immunocomplex, the analyte concentration is quantified as the signal of Ag nanoparticle labels determined by LIBS.


Assuntos
Imunoensaio/métodos , Lasers , Nanopartículas Metálicas/química , Albumina Sérica Humana/análise , Biomarcadores/sangue , Ouro/química , Humanos , Tamanho da Partícula , Prata/química , Propriedades de Superfície
14.
Anal Chem ; 90(20): 11820-11826, 2018 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-30126278

RESUMO

Nanoparticles (NPs) applied to the surface of some solids can increase signals in inductively coupled plasma mass spectrometry (ICPMS). Drops containing 20 and/or 40 nm nanoparticles of Ag and/or Au were deposited on metallic and ceramic/glass samples, and after being dried, both the samples treated with NPs and plain targets were ablated by one pulse per spot. The laser ablation ICPMS (LA-ICPMS) signals were enhanced for metallic samples modified with NPs in comparison to signals produced at the plain, untreated surface. Maps of LA-ICPMS signals recorded for several laser fluences show that the NP-induced signal enhancement exceeds even 2 orders of magnitude for metallic samples. No enhancement was achieved for nonconductive samples. This enhancement is limited to the peripheral annular region of the dried droplet area where NPs are concentrated due to the "coffee stain" effect. Ablation crater profilometric inspection revealed a more uniform material rearrangement over the NP-treated surface compared with the ablated plain target. However, besides a smoother crater bottom, no other evidence of an NP-enhancing effect was noticed, although an increased ablation rate was anticipated. Limits of detection dropped by 1 order of magnitude for the minor elements in the presence of NPs. Observed phenomena depend only on the NP surface concentration but not on the material or size of the NPs. An electron microprobe study of the collected ablation aerosol has shown that aerosol particles consisting of target material are aggregated around the NPs. The hypothesis is that such aggregates exhibit better transport/vaporization efficiency, thus enhancing signals for metallic samples. A detailed study of the suggested mechanism will be continued in ongoing work.

15.
J Anat ; 2018 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-29855036

RESUMO

Derivation of periosteal and endosteal contours taken from transversal long bone cross-sections limits the accuracy of calculated biomechanical properties. Although several techniques are available for deriving both contours, the effect of these techniques on accuracy of calculated cross-sectional properties in non-adults is unknown. We examine a sample of 86 non-adult femora from birth to 12 years of age to estimate the effect of error in deriving periosteal and endosteal contours on cross-sectional properties. Midshaft cross-sections were taken from microCT scans and contours were derived using manual, fully automatic, spline, and ellipse techniques. Agreement between techniques was assessed against manually traced periosteal and endosteal contours using percent prediction error (%PE), reduced major axis analysis, and limits of agreement. The %PEs were highest in the medullary area and lowest in the total area. Mean %PEs were sufficiently below the 5% level of acceptable error, except for medullary areas, but individual values can greatly exceed this 5% boundary given the high standard deviation of %PE means and wide minimum-maximum range of %PEs. Automatic processing produces greater errors than does combination with manual, spline, and ellipse processing. Although periosteal contour is estimated with stronger agreement compared with endosteal contour, error in deriving periosteal contour has a substantially greater effect on calculated section moduli than does error in deriving endosteal contours. We observed no size effect on the resulting bias. Nevertheless, cross-sectional properties in a younger age category may be estimated with greater error compared with in an older age category. We conclude that non-adult midshaft cross-sectional properties can be derived from microCT scans of femoral diaphyses with mean error of < 5% and that derivation of endosteal contour can be simplified by the ellipse technique because fully automatic derivation of endosteal contour may increase the resulting error, especially in small samples.

16.
FASEB J ; 31(3): 1067-1084, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27965322

RESUMO

Articular cartilage has little regenerative capacity. Recently, genetic lineage tracing experiments have revealed chondrocyte progenitors at the articular surface. We further characterized these progenitors by using in vivo genetic approaches. Histone H2B-green fluorescent protein retention revealed that superficial cells divide more slowly than underlying articular chondrocytes. Clonal genetic tracing combined with immunohistochemistry revealed that superficial cells renew their number by symmetric division, express mesenchymal stem cell markers, and generate chondrocytes via both asymmetric and symmetric differentiation. Quantitative analysis of cellular kinetics, in combination with phosphotungstic acid-enhanced micro-computed tomography, showed that superficial cells generate chondrocytes and contribute to the growth and reshaping of articular cartilage. Furthermore, we found that cartilage renewal occurs as the progeny of superficial cells fully replace fetal chondrocytes during early postnatal life. Thus, superficial cells are self-renewing progenitors that are capable of maintaining their own population and fulfilling criteria of unipotent adult stem cells. Furthermore, the progeny of these cells reconstitute adult articular cartilage de novo, entirely substituting fetal chondrocytes.-Li, L., Newton, P. T., Bouderlique, T., Sejnohova, M., Zikmund, T., Kozhemyakina, E., Xie, M., Krivanek, J., Kaiser, J., Qian, H., Dyachuk, V., Lassar, A. B., Warman, M. L., Barenius, B., Adameyko, I., Chagin, A. S. Superficial cells are self-renewing chondrocyte progenitors, which form the articular cartilage in juvenile mice.


Assuntos
Células-Tronco Adultas/citologia , Cartilagem Articular/citologia , Condrócitos/citologia , Condrogênese , Animais , Cartilagem Articular/fisiologia , Camundongos , Regeneração
17.
Ecotoxicol Environ Saf ; 147: 334-341, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28858706

RESUMO

The purpose of this study was to determine the toxicity of two different sources of cadmium, i.e. CdCl2 and Cd-based Quantum Dots (QDs), for freshwater model plant Lemna minor L. Cadmium telluride QDs were capped with two coating ligands: glutathione (GSH) or 3-mercaptopropionic acid (MPA). Growth rate inhibition and final biomass inhibition of L. minor after 168-h exposure were monitored as toxicity endpoints. Dose-response curves for Cd toxicity and EC50168h values were statistically evaluated for all sources of Cd to uncover possible differences among the toxicities of tested compounds. Total Cd content and its bioaccumulation factors (BAFs) in L. minor after the exposure period were also determined to distinguish Cd bioaccumulation patterns with respect to different test compounds. Laser-Induced Breakdown Spectroscopy (LIBS) with lateral resolution of 200µm was employed in order to obtain two-dimensional maps of Cd spatial distribution in L. minor fronds. Our results show that GSH- and MPA-capped Cd-based QDs have similar toxicity for L. minor, but are significantly less toxic than CdCl2. However, both sources of Cd lead to similar patterns of Cd bioaccumulation and distribution in L. minor fronds. Our results are in line with previous reports that the main mediators of Cd toxicity and bioaccumulation in aquatic plants are Cd2+ ions dissolved from Cd-based QDs.


Assuntos
Araceae/efeitos dos fármacos , Cloreto de Cádmio/toxicidade , Compostos de Cádmio/toxicidade , Monitoramento Ambiental/métodos , Pontos Quânticos/toxicidade , Telúrio/toxicidade , Poluentes Químicos da Água/toxicidade , Ácido 3-Mercaptopropiônico/química , Adsorção , Araceae/crescimento & desenvolvimento , Araceae/metabolismo , Biomassa , Cloreto de Cádmio/metabolismo , Compostos de Cádmio/metabolismo , Água Doce/química , Glutationa/química , Modelos Teóricos , Pontos Quânticos/metabolismo , Telúrio/metabolismo , Poluentes Químicos da Água/química
18.
Ecotoxicol Environ Saf ; 153: 23-31, 2018 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-29407734

RESUMO

We report on the toxicity and bioaccumulation of three different types of Cd-based quantum dots (QDs), dispersed in aqueous medium, for a model plant Allium cepa L. It is believed that encapsulation of nanoparticles should reduce their toxicity and increase their stability in different environments; in this work we studied how QD encapsulation affects their phytotoxicity. Core, core/shell, and core/shell/shell QDs (CdTe, CdTe/ZnS, and CdTe/CdS/ZnS QDs capped by 2-mercaptopropionic acid) were tested and CdCl2 was used as a positive control. After 24-h and 72-h exposure, total Cd content (MCd) and bioaccumulation factors (BAFs) were determined in all parts of A. cepa plants (roots, bulb, shoot), and the total length of the root system was monitored as a toxicity end-point. Measurements of total Cd content versus free Cd2+ content (with Differential Pulse Voltammetry, DPV) in exposure media showed differences in chemical stability of the three QD types. Correspondingly, selected QDs showed different toxicity for A. cepa and different Cd bioaccumulation patterns. CdTe QDs were the most toxic; their effect was similar to CdCl2 due to the release of free Cd2+, which was confirmed by the DPV measurements. Plants exposed to CdTe QDs also bioaccumulated the most Cd among all QD exposure groups. CdTe/ZnS QDs showed no toxicity and very low bioaccumulation of Cd in A. cepa; the main source of measured Cd in the plants were QDs adsorbed on their roots, which was confirmed by fluorescence microscopy. On the contrary, CdTe/CdS/ZnS QD toxicity and bioaccumulation patterns were similar to those of CdTe QDs and pointed to unstable CdS/ZnS shells.


Assuntos
Compostos de Cádmio/análise , Compostos de Cádmio/toxicidade , Cebolas/efeitos dos fármacos , Pontos Quânticos/análise , Pontos Quânticos/toxicidade , Adsorção , Microscopia de Fluorescência , Cebolas/química , Raízes de Plantas/química , Raízes de Plantas/efeitos dos fármacos
19.
J Anat ; 229(3): 356-68, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27173578

RESUMO

Chameleon teeth develop as individual structures at a distance from the developing jaw bone during the pre-hatching period and also partially during the post-hatching period. However, in the adult, all teeth are fused together and tightly attached to the jaw bone by mineralized attachment tissue to form one functional unit. Tooth to bone as well as tooth to tooth attachments are so firm that if injury to the oral cavity occurs, several neighbouring teeth and pieces of jaw can be broken off. We analysed age-related changes in chameleon acrodont dentition, where ankylosis represents a physiological condition, whereas in mammals, ankylosis only occurs in a pathological context. The changes in hard-tissue morphology and mineral composition leading to this fusion were analysed. For this purpose, the lower jaws of chameleons were investigated using X-ray micro-computed tomography, laser-induced breakdown spectroscopy and microprobe analysis. For a long time, the dental pulp cavity remained connected with neighbouring teeth and also to the underlying bone marrow cavity. Then, a progressive filling of the dental pulp cavity by a mineralized matrix occurred, and a complex network of non-mineralized channels remained. The size of these unmineralized channels progressively decreased until they completely disappeared, and the dental pulp cavity was filled by a mineralized matrix over time. Moreover, the distribution of calcium, phosphorus and magnesium showed distinct patterns in the different regions of the tooth-bone interface, with a significant progression of mineralization in dentin as well as in the supporting bone. In conclusion, tooth-bone fusion in chameleons results from an enhanced production of mineralized tissue during post-hatching development. Uncovering the developmental processes underlying these outcomes and performing comparative studies is necessary to better understand physiological ankylosis; for that purpose, the chameleon can serve as a useful model species.


Assuntos
Dentição , Arcada Osseodentária/anatomia & histologia , Calcificação de Dente/fisiologia , Dente/anatomia & histologia , Dente/fisiologia , Envelhecimento , Animais , Lagartos , Microtomografia por Raio-X
20.
J Mater Sci Mater Med ; 27(6): 110, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27153826

RESUMO

In this work we have used X-ray micro-computed tomography (µCT) as a method to observe the morphology of 3D porous pure collagen and collagen-composite scaffolds useful in tissue engineering. Two aspects of visualizations were taken into consideration: improvement of the scan and investigation of its sensitivity to the scan parameters. Due to the low material density some parts of collagen scaffolds are invisible in a µCT scan. Therefore, here we present different contrast agents, which increase the contrast of the scanned biopolymeric sample for µCT visualization. The increase of contrast of collagenous scaffolds was performed with ceramic hydroxyapatite microparticles (HAp), silver ions (Ag(+)) and silver nanoparticles (Ag-NPs). Since a relatively small change in imaging parameters (e.g. in 3D volume rendering, threshold value and µCT acquisition conditions) leads to a completely different visualized pattern, we have optimized these parameters to obtain the most realistic picture for visual and qualitative evaluation of the biopolymeric scaffold. Moreover, scaffold images were stereoscopically visualized in order to better see the 3D biopolymer composite scaffold morphology. However, the optimized visualization has some discontinuities in zoomed view, which can be problematic for further analysis of interconnected pores by commonly used numerical methods. Therefore, we applied the locally adaptive method to solve discontinuities issue. The combination of contrast agent and imaging techniques presented in this paper help us to better understand the structure and morphology of the biopolymeric scaffold that is crucial in the design of new biomaterials useful in tissue engineering.


Assuntos
Colágeno/química , Alicerces Teciduais/química , Microtomografia por Raio-X , Materiais Biocompatíveis/química , Meios de Contraste , Durapatita/química , Nanopartículas Metálicas/química , Prata/química
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa