Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ophthalmic Res ; 63(2): 114-121, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31801148

RESUMO

BACKGROUND: First-line treatment for diabetic macular edema (DME) is usually with antivascular endothelial growth factor agents, followed by intravitreal corticosteroids as a second-line treatment option. Long-term corticosteroids may offer quality of life and effectiveness benefits over short-term implants. OBJECTIVES: To evaluate outcomes of patients with persistent or recurrent DME who switched from a short-term (dexamethasone) to a long-term (fluocinolone acetonide, FAc) corticosteroid intravitreal implant in a real-world setting. METHODS: This is a retrospective study in 9 Portuguese centers. An FAc intravitreal implant was administered according to product labeling. Effectiveness outcomes were mean change in visual acuity (VA; ETDRS letters), central retinal thickness (CRT; µm), and macular volume (MV; mm3). The safety outcome was mean change in intraocular pressure (IOP; mm Hg). All were analyzed at months 1 and 3, and then quarterly until month 24 after implantation. RESULTS: Forty-four eyes from 36 patients were analyzed. Mean duration of DME was 3.3 ± 1.9 years, and mean follow-up was 8 months. From baseline following FAc implantation, VA increased significantly at months 1 and 6 (mean +6.82 and +13.02 letters, respectively; p = 0.005), and last observation carried forward (LOCF; mean +8.3 letters; p = 0.002). CRT improved significantly at months 1 and 6 (mean -71.81 and -170.77 µm, respectively; p = 0.001), and LOCF (mean -121.46 µm; p = 0.001). MV was consistently, but not significantly, decreased from baseline to LOCF (mean -0.69 mm3; p = 0.062). The mean change in IOP was -0.25 and +0.88 mm Hg at months 1 and 6, respectively (p = 0.268), and +1.86 mm Hg at LOCF (p = 0.036). Increases were controlled with topical medication in most cases. CONCLUSIONS: The FAc intravitreal implant is effective in patients previously treated with short-term corticosteroid implants. Thus, after a suboptimal response to antiangiogenics or a short-term corticosteroid, a single FAc implant may be considered an effective and tolerable treatment that can improve long-term outcomes for patients with sight-threatening DME.


Assuntos
Retinopatia Diabética/tratamento farmacológico , Fluocinolona Acetonida/administração & dosagem , Edema Macular/tratamento farmacológico , Acuidade Visual , Idoso , Retinopatia Diabética/complicações , Retinopatia Diabética/diagnóstico , Implantes de Medicamento , Feminino , Seguimentos , Glucocorticoides/administração & dosagem , Humanos , Pressão Intraocular/efeitos dos fármacos , Injeções Intravítreas , Macula Lutea/patologia , Edema Macular/diagnóstico , Edema Macular/etiologia , Masculino , Qualidade de Vida , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
2.
J Curr Glaucoma Pract ; 10(3): 85-90, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27857487

RESUMO

AIM: To determine the relationship between macular thickness (MT) and visual field (VF) parameters, as well as with changes in the retinal nerve fiber layer (RNFL) thickness in patients with glaucoma and ocular hypertension (OH). MATERIALS AND METHODS: Cross-sectional statistical analysis of spectral domain optical coherence tomography (SD-OCT) compared with several VF parameters (mean defect - MD and loss variance - LV), in a nonrandom sample of 70 eyes from patients with glaucoma or OH. Statistical analysis was performed using Statistical Package for Social Sciences®. The correlation coefficient used was determined by Spearman correlation and the value of p < 0.05 was considered statistically significant. RESULTS: A significant correlation was seen between VF parameters and decrease in MT (MD: r = -0.363, p = 0.002; LV: r=-0.378, p = 0.001). The results were more significant when we compared the LV in the group with average MT 270 to 300 µm (r = -0.413, p = 0.015). Asymmetry between the superior macula and inferior macula correlated with LV (r = 0.432, p = 0.019) in the group with MT < 270 µm. There was also a significant correlation between thinning of superior-temporal and inferior-temporal RNFL and the decrease of the superior and inferior MT respectively (p < 0.001). CONCLUSION: Spectral domain optical coherence tomography measurements of retinal thickness in the macula correlate with VF parameters and RNFL parameters in glaucoma patients. This relationship was first demonstrated with static computerized perimetry made with Octopus 101®. These results can be a valuable aid for evaluating and monitoring of glaucoma patients, establishing a correlation between structure and function. Measurements of retinal thickness in the macula may be an additional instrument for early detection of structural changes and its correlation with functional defects. HOW TO CITE THIS ARTICLE: Mota M, Vaz FT, Ramalho M, Pedrosa C, Lisboa M, Kaku P, Esperancinha F. Macular Thickness Assessment in Patients with Glaucoma and Its Correlation with Visual Fields. J Curr Glaucoma Pract 2016;10(3):85-90.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa