Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Altern Lab Anim ; : 2611929241256040, 2024 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-38910363

RESUMO

Phototoxicity testing is crucial for evaluating the potential harmful effects of pharmaceuticals and chemicals on human skin when exposed to sunlight. Traditional in vivo models involving mice, rats, guinea pigs, as well as in vitro assays such as the 3T3 Neutral Red Uptake phototoxicity assay and methods based on the use of reconstructed human epidermis, have been established for phototoxicity testing. While these approaches are extremely valuable, they are costly in terms of both time and resources. Consequently, in silico approaches based on the use of predictive software tools can offer more rapid and cost-effective phototoxicity screening solutions. With this goal in mind, the current study evaluated two in silico tools - Derek Nexus 6.1.0/Derek Knowledge Base 2020 1.0 (Lhasa Limited, UK) and the QSAR Toolbox (v 4.5) developed by the Organisation for Economic Co-operation and Development (OECD) - for their capacity to predict the phototoxicity of several substances from diverse classes. Derek Nexus and the QSAR Toolbox were both found to be very useful for predicting the phototoxicity of drugs and other chemicals. Derek Nexus predicted phototoxicity of the compounds, with a sensitivity of 63%, specificity of 93%, Positive Predictive Values of 90% and Negative Predictive Value of 69%, overall accuracy of 77% and balanced accuracy of 78%. The QSAR Toolbox achieved sensitivity of 73%, specificity of 85%, Positive Predictive Value of 85% and Negative Predictive Value of 74%, overall accuracy of 79% and balanced accuracy of 79%. The results show that Derek Nexus and the QSAR Toolbox can be usefully incorporated in the workflow of phototoxicity testing for pharmaceuticals and chemicals.

2.
Altern Lab Anim ; 52(2): 117-131, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38235727

RESUMO

The first Stakeholder Network Meeting of the EU Horizon 2020-funded ONTOX project was held on 13-14 March 2023, in Brussels, Belgium. The discussion centred around identifying specific challenges, barriers and drivers in relation to the implementation of non-animal new approach methodologies (NAMs) and probabilistic risk assessment (PRA), in order to help address the issues and rank them according to their associated level of difficulty. ONTOX aims to advance the assessment of chemical risk to humans, without the use of animal testing, by developing non-animal NAMs and PRA in line with 21st century toxicity testing principles. Stakeholder groups (regulatory authorities, companies, academia, non-governmental organisations) were identified and invited to participate in a meeting and a survey, by which their current position in relation to the implementation of NAMs and PRA was ascertained, as well as specific challenges and drivers highlighted. The survey analysis revealed areas of agreement and disagreement among stakeholders on topics such as capacity building, sustainability, regulatory acceptance, validation of adverse outcome pathways, acceptance of artificial intelligence (AI) in risk assessment, and guaranteeing consumer safety. The stakeholder network meeting resulted in the identification of barriers, drivers and specific challenges that need to be addressed. Breakout groups discussed topics such as hazard versus risk assessment, future reliance on AI and machine learning, regulatory requirements for industry and sustainability of the ONTOX Hub platform. The outputs from these discussions provided insights for overcoming barriers and leveraging drivers for implementing NAMs and PRA. It was concluded that there is a continued need for stakeholder engagement, including the organisation of a 'hackathon' to tackle challenges, to ensure the successful implementation of NAMs and PRA in chemical risk assessment.


Assuntos
Rotas de Resultados Adversos , Inteligência Artificial , Animais , Humanos , Testes de Toxicidade , Medição de Risco , Bélgica
3.
Altern Lab Anim ; 51(4): 224-248, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37377062

RESUMO

Animal testing has been prohibited for the safety assessment of cosmetic ingredients or finished products. Thus, alternative non-animal methods, followed by confirmatory clinical studies on human volunteers, should be used as the sole legally acceptable approach within the EU. The safety assessment of cosmetic products requires the involvement of multiple scientific disciplines, including analytical chemistry and biomedicine, as well as in chemico, in vitro and in silico toxicology. Recent data suggest that fragrance components may exert multiple adverse biological effects, e.g. cytotoxicity, skin sensitisation, (photo)genotoxicity, mutagenicity, reprotoxicity and endocrine disruption. Therefore, a pilot study was conducted with selected samples of fragrance-based products, such as deodorant, eau de toilette and eau de parfum, with the aim of integrating results from a number of alternative non-animal methods suitable for the detection of the following toxicological endpoints: cytotoxicity (with 3T3 Balb/c fibroblasts); skin sensitisation potential (in chemico method, DPRA); skin sensitisation potential (LuSens in vitro method, based on human keratinocytes); genotoxicity potential (in vitro Comet assay with 3T3 Balb/c cells); and endocrine disruption (in vitro YES/YAS assay). The presence of twenty-four specific known allergens in the products was determined by using GC-MS/MS. The strategies for estimation of the NOAEL of a mixture of allergens, which were proposed by the Scientific Committee on Consumer Products in their 'Opinion on Tea tree oil' document and by the Norwegian Food Safety Authority in their 'Risk Profile of Tea tree oil' report, were used as models for the NOAEL estimation of the mixtures of allergens that were identified in the individual samples tested in this study.


Assuntos
Cosméticos , Perfumes , Óleo de Melaleuca , Animais , Humanos , Perfumes/análise , Espectrometria de Massas em Tandem , Cromatografia Gasosa-Espectrometria de Massas , Projetos Piloto , Cosméticos/toxicidade , Alérgenos/toxicidade , Alérgenos/análise
4.
Altern Lab Anim ; 50(2): 156-171, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35410493

RESUMO

The fact that animal models fail to replicate human disease faithfully is now being widely accepted by researchers across the globe. As a result, they are exploring the use of alternatives to animal models. The time has come to refine our experimental practices, reduce the numbers and eventually replace the animals used in research with human-derived and human-relevant 3-D disease models. Oncoseek Bio-Acasta Health, which is an innovative biotechnology start-up company based in Hyderabad and Vishakhapatnam, India, organises an annual International Conference on 3Rs Research and Progress. In 2021, this conference was on 'Advances in Research Animal Models and Cutting-Edge Research in Alternatives'. This annual conference is a platform that brings together eminent scientists and researchers from various parts of the world, to share recent advances from their research in the field of alternatives to animals including new approach methodologies, and to promote practices to help refine animal experiments where alternatives are not available. This report presents the proceedings of the conference, which was held in hybrid mode (i.e. virtual and in-person) in November 2021.


Assuntos
Experimentação Animal , Alternativas aos Testes com Animais , Alternativas aos Testes com Animais/métodos , Bem-Estar do Animal , Animais , Humanos , Índia , Modelos Animais
5.
Handb Exp Pharmacol ; 265: 57-71, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33367950

RESUMO

Three-dimensional (3D) reconstructed human skin (RhS) models featuring fully-differentiated characteristics of in vivo human epidermis have been known for almost 40 years. In this chapter, the topic of commercial in vitro tissue models is described, taking RhS models as an example. The need for highly standardised models is evident for regulatory testing purposes, e.g. the classification and labelling of chemicals and formulations, as well as for pharmacology-oriented research and drug development. Following the standardisation of RhS model production by commercial developers, international validation studies and regulatory acceptance, 3D RhS models are now used globally in both industrial and academic research laboratories. Industrial production of standardised 3D RhS models involves GMP-compliant processes together with ISO 9001 documentation in order to control and ensure reproducibility and quality. Key biological, functional, and performance features that are addressed in industrial production include barrier properties, histological and immunohistochemical characterisation, lipid profile characterisation, and tissue viability before and after transport. An up-to-date survey of commercial RhS tissue producers and the regulatory acceptance status of major safety, hazard, and efficacy assays currently available to chemical and pharmaceutical industries is presented in this chapter. Safety and ethical concerns related to the use of human tissue in the industrial production of RhS models are discussed. Finally, innovative approaches to the production of standardised 3D RhS models including automated production, development of more representative 3D RhS models using advanced additive manufacturing tools, microfluidics technologies, and bioprinting are presented. The future outlook for 3D RhS models includes a prevalence of high-quality models which will be fabricated by end-users rather than commercial producers. These will overcome problems with shipments and customs clearance that many users still face when buying RhS from overseas commercial suppliers. Open-source technologies and commercial components for "do-it-yourself" RhS will significantly change the skin model market as well as regulatory acceptance of open-source models during the next decade. All of these developments and improvements will together allow more widespread use of in vitro RhS models for broader application as animal replacements in areas ranging from industrial and regulatory toxicology and pharmacology, to drug development and personalised medicine.


Assuntos
Pele , Animais , Humanos , Reprodutibilidade dos Testes
6.
Altern Lab Anim ; 49(1-2): 33-48, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33910377

RESUMO

Health care facilities and hospitals generate significant amounts of wastewater which are released into the sewage system, either after a preliminary treatment or without any further treatment. Hospital wastewater may contain large amounts of hazardous chemicals and pharmaceuticals, some of which cannot be eliminated entirely by wastewater treatment plants. Moreover, hospital effluents may be loaded with a plethora of pathogenic microorganisms or other microbiota and microbiome residues. The need to monitor hospital effluents for their genotoxic hazard is of high importance, as detailed information is scarce. DNA-based information can be acquired directly from samples through the application of various molecular methods, while cell-based biomonitoring assays can provide important information about impaired cellular pathways or mechanisms of toxicity without prior knowledge of the identity of each toxicant. In our study, we evaluated samples of chlorinated hospital wastewater discharged into the sewage system after this disinfection process. The assessment of cytotoxicity, genotoxicity and mutagenicity of the hospital effluents was performed in vitro by using a broad battery of biomonitoring assays that are relevant for human health effects. All the tested hospital wastewater samples could be classified as potentially genotoxic, and it is concluded that the microbiota present in hospital wastewater might contribute to this genotoxic potential.


Assuntos
Águas Residuárias , Poluentes Químicos da Água , Dano ao DNA , Hospitais , Humanos , Testes de Mutagenicidade , Águas Residuárias/toxicidade , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/toxicidade
7.
Altern Lab Anim ; 49(3): 93-110, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34225465

RESUMO

Experimental systems that faithfully replicate human physiology at cellular, tissue and organ level are crucial to the development of efficacious and safe therapies with high success rates and low cost. The development of such systems is challenging and requires skills, expertise and inputs from a diverse range of experts, such as biologists, physicists, engineers, clinicians and regulatory bodies. Kirkstall Limited, a biotechnology company based in York, UK, organised the annual conference, Advances in Cell and Tissue Culture (ACTC), which brought together people having a variety of expertise and interests, to present and discuss the latest developments in the field of cell and tissue culture and in vitro modelling. The conference has also been influential in engaging animal welfare organisations in the promotion of research, collaborative projects and funding opportunities. This report describes the proceedings of the latest ACTC conference, which was held virtually on 30th September and 1st October 2020, and included sessions on in vitro models in the following areas: advanced skin and respiratory models, neurological disease, cancer research, advanced models including 3-D, fluid flow and co-cultures, diabetes and other age-related disorders, and animal-free research. The roundtable session on the second day was very interactive and drew huge interest, with intriguing discussion taking place among all participants on the theme of replacement of animal models of disease.


Assuntos
Dispositivos Lab-On-A-Chip , Pele , Animais , Técnicas de Cocultura , Humanos , Modelos Animais
8.
Regul Toxicol Pharmacol ; 115: 104685, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32454236

RESUMO

The aim of the study was toxicological testing of an innovative and efficient antimicrobial agent based on photoactive phthalocyanine (Pc) derivative. A promising Aluminium phthalocyanine (AlPc) with efficient and stable antimicrobial effects was subjected to a battery of toxicological tests to avoid local and systemic toxicity hazard. In compliance with the current European legislation restricting the use of experimental animals, the methods comprised exclusively in vitro procedures based on cellular and tissue models of human origin or mimicking human tissues. The battery of toxicological tests to identify local toxicity included skin corrosion/irritation, eye irritation, and phototoxicity. The basic systemic toxicity tests included acute toxicity, skin sensitization, genotoxicity, and endocrine disruption. The results showed that AlPc induced skin and eye irritation, exhibited borderline sensitization potential and mutagenic potential in one test strain of the Ames test, which was not confirmed in the chromosome aberration test. The AlPc was found to be phototoxic. The results from the cytotoxicity test designed for acute oral toxicity estimation were not conclusive, the acute toxicity potential has to be determined by conventional tests in vivo. Regarding endocrine disruption, no agonistic activity of the AlPc on human estrogen receptor α, nor human androgen receptor was observed. The skin penetration/absorption test revealed that the AlPc has not penetrated into the dermis and receptor fluid, confirming no risk of systemic exposure via the bloodstream.


Assuntos
Anti-Infecciosos/toxicidade , Indóis/toxicidade , Irritantes/toxicidade , Animais , Anti-Infecciosos/farmacocinética , Células Cultivadas , Embrião de Galinha , Membrana Corioalantoide/irrigação sanguínea , Membrana Corioalantoide/efeitos dos fármacos , Dano ao DNA , Receptor alfa de Estrogênio/metabolismo , Olho/efeitos dos fármacos , Humanos , Indóis/farmacocinética , Irritantes/farmacocinética , Isoindóis , Linfócitos/efeitos dos fármacos , Camundongos Endogâmicos BALB C , Processos Fotoquímicos , Receptores Androgênicos/metabolismo , Pele/efeitos dos fármacos , Pele/metabolismo , Absorção Cutânea , Suínos , Testes de Toxicidade
9.
Altern Lab Anim ; 50(5): 315-316, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36127880
10.
Altern Lab Anim ; 43(2): 101-27, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25995013

RESUMO

The 7th Amendment to the EU Cosmetics Directive and the EU REACH Regulation have reinforced the need for in vitro ocular test methods. Validated in vitro ocular toxicity tests that can predict the human response to chemicals, cosmetics and other consumer products are required for the safety assessment of materials that intentionally, or inadvertently, come into contact with the eye. The EpiOcular Eye Irritation Test (EIT), which uses the normal human cell-based EpiOcular™ tissue model, was developed to address this need. The EpiOcular-EIT is able to discriminate, with high sensitivity and accuracy, between ocular irritant/corrosive materials and those that require no labelling. Although the original EpiOcular-EIT protocol was successfully pre-validated in an international, multicentre study sponsored by COLIPA (the predecessor to Cosmetics Europe), data from two larger studies (the EURL ECVAM-COLIPA validation study and an independent in-house validation at BASF SE) resulted in a sensitivity for the protocol for solids that was below the acceptance criteria set by the Validation Management Group (VMG) for eye irritation, and indicated the need for improvement of the assay's sensitivity for solids. By increasing the exposure time for solid materials from 90 minutes to 6 hours, the optimised EpiOcular-EIT protocol achieved 100% sensitivity, 68.4% specificity and 84.6% accuracy, thereby meeting all the acceptance criteria set by the VMG. In addition, to satisfy the needs of Japan and the Pacific region, the EpiOcular-EIT method was evaluated for its performance after extended shipment and storage of the tissues (4-5 days), and it was confirmed that the assay performs with similar levels of sensitivity, specificity and reproducibility in these circumstances.


Assuntos
Olho/efeitos dos fármacos , Irritantes/toxicidade , Testes de Toxicidade/métodos , Alternativas aos Testes com Animais , Humanos
11.
Front Toxicol ; 5: 1337468, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38259728

RESUMO

Biocompatibility testing ensures the safety of medical devices by assessing their compatibility with biological systems and their potential to cause harm or adverse reactions. Thus, it is a critical part of the overall safety evaluation process for medical devices. Three primary types of biocompatibility tests-cytotoxicity, irritation, and sensitisation assessment-are standard for nearly all medical devices. However, additional biocompatibility tests, such as genotoxicity, systemic toxicity, hemocompatibility, and implantation studies, may also be necessary, depending on the device's nature and intended use. The testing is partly conducted in vitro, but the industry still heavily relies on animal experiments. Compared to other industrial sectors, implementing alternatives in medical device biocompatibility testing has been notably slower. This delay can be attributed to the absence of specific validation processes tailored to medical devices and the resulting hesitation regarding the predictive capacity of these alternative methods despite their successful applications in other domains. This review focuses on the progress and obstacles to implementing new approach methodologies in the areas of cytotoxicity, irritation and sensitisation testing of medical devices. While challenges persist in adopting these innovative methods, the trend towards embracing alternatives remains robust. This trend is driven by technological advancements, ethical considerations, and growing industrial interest and support, all collectively contributing to advancing safer and more effective medical devices.

12.
Toxicol In Vitro ; 92: 105640, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37419426

RESUMO

The emergence of the highly contagious respiratory disease, COVID-19, caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has become a significant global public health concern. To combat this virus, researchers have focused on developing antiviral strategies that target specific viral components, such as the main protease (Mpro), which plays a crucial role in SARS-CoV-2 replication. While many compounds have been identified as potent inhibitors of Mpro, only a few have been translated into clinical use due to the potential risk-benefit trade-offs. Development of systemic inflammatory response and bacterial co-infection in patients belong to severe, frequent complications of COVID-19. In this context, we analysed available data on the anti-inflammatory and antibacterial activities of the SARS-CoV-2 Mpro inhibitors for possible implementation in the treatment of complicated and long COVID-19 cases. Synthetic feasibility and ADME properties were calculated and included for better characterisation of the compounds' predicted toxicity. Analysis of the collected data resulted in several clusters pointing to the most prospective compounds for further study and design. The complete tables with collected data are attached in Supplementary material for use by other researchers.


Assuntos
COVID-19 , Humanos , SARS-CoV-2 , Síndrome de COVID-19 Pós-Aguda , Estudos Prospectivos , Antivirais/farmacologia , Simulação de Acoplamento Molecular
13.
Regul Toxicol Pharmacol ; 63(3): 480-8, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22687423

RESUMO

This is the report from the "ECVAM-EFPIA workshop on 3T3 NRU Phototoxicity Test: Practical Experience and Implications for Phototoxicity Testing", jointly organized by ECVAM and EFPIA and held on the 25-27 October 2010 in Somma Lombardo, Italy. The European Centre for the Validation of Alternative Methods (ECVAM) was established in 1991 within the European Commission Joint Research, based on a Communication from the European Commission (1991). The main objective of ECVAM is to promote the scientific and regulatory acceptance of alternative methods which are of importance to the biosciences and which reduce, refine and replace the use of laboratory animals. The European Federation of Pharmaceuticals Industries and Association (EFPIA) represent the pharmaceutical industry operating in Europe. Through its direct membership of 31 national associations and 40 leading pharmaceutical companies, EFPIA is the voice on the EU scene of 2200 companies committed to researching, developing and bringing to patients new medicines that improve health and the quality of life around the world. The workshop, co-chaired by Joachim Kreysa (ECVAM) and Phil Wilcox (GSK, EFPIA) involved thirty-five experts from academia, regulatory authorities and industry, invited to contribute with their experiences in the field of phototoxicology. The main objectives of the workshop were: -to present 'in use' experience of the pharmaceutical industry with the 3T3 Neutral Red Uptake Phototoxicity Test (3T3 NRU-PT), -to discuss why it differs from the results in the original validation exercise, -to discuss technical issues and consider ways to improve the usability of the 3T3 NRU-PT for (non-topical) pharmaceuticals, e.g., by modifying the threshold of chemical light absorption to trigger photo-toxicological testing, and by modifying technical aspects of the assay, or adjusting the criteria used to classify a positive response. During the workshop, the assay methodology was reviewed by comparing the OECD Test Guideline (TG 432) with the protocols used in testing laboratories, data from EFPIA and JPMA 'surveys' were presented and possible reasons for the outcomes were discussed. Experts from cosmetics and pharmaceutical industries reported on their experience with the 3T3 NRU-PT and evidence was presented for phototoxic clinical symptoms that could be linked to certain relevant molecules. Brainstorming sessions discussed if the 3T3 NRU-PT needed to be improved and whether alternatives to the 3T3 NRU-PT exist. Finally, the viewpoint from EU and US regulators was presented. In the final session, the conclusions of the meeting were summarized, with action points. It was concluded that the 3T3 NRU-PT identifies phototoxicological hazards with a 100% sensitivity, and thus is accepted as the tier one test that correctly identifies the absence of phototoxic potential. Consequently, positive results in the 3T3 NRU-PT often do not translate into a clinical phototoxicity risk. Possible ways to improve the practical use of this assay include: (i) adaptation of changed UV/vis-absorption criteria as a means to reduce the number of materials tested, (ii) reduction of the highest concentration to be tested, and (iii) consideration of modifying the threshold criteria for the prediction of a positive call in the test.


Assuntos
Alternativas aos Testes com Animais/métodos , Dermatite Fototóxica , Vermelho Neutro/metabolismo , Fármacos Fotossensibilizantes/toxicidade , Testes de Toxicidade/métodos , Células 3T3 , Animais , Bioensaio/métodos , Qualidade de Produtos para o Consumidor , Cosméticos/toxicidade , Dermatite Fototóxica/etiologia , Indústria Farmacêutica , Camundongos , Espécies Reativas de Oxigênio/metabolismo
14.
Altern Lab Anim ; 39(4): 339-64, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21942547

RESUMO

The recently implemented 7th Amendment to the EU Cosmetics Directive and the EU REACH legislation have heightened the need for in vitro ocular test methods. To address this need, the EpiOcular(TM) eye irritation test (EpiOcular-EIT), which utilises the normal (non-transformed) human cell-based EpiOcular tissue model, has been developed. The EpiOcular-EIT prediction model is based on an initial training set of 39 liquid and 21 solid test substances and uses a single exposure period and a single cut-off in tissue viability, as determined by the MTT assay. A chemical is classified as an irritant (GHS Category 1 or 2), if the tissue viability is ≤ 60%, and as a non-irritant (GHS unclassified), if the viability is > 60%. EpiOcular-EIT results for the training set, along with results for an additional 52 substances, which included a range of alcohols, hydrocarbons, amines, esters, and ketones, discriminated between ocular irritants and non-irritants with 98.1% sensitivity, 72.9% specificity, and 84.8% accuracy. To ensure the long-term commercial viability of the assay, EpiOcular tissues produced by using three alternative cell culture inserts were evaluated in the EpiOcular-EIT with 94 chemicals. The assay results obtained with the initial insert and the three alternative inserts were very similar, as judged by correlation coefficients (r²) that ranged from 0.82 to 0.96. The EpiOcular-EIT was pre-validated in 2007/2008, and is currently involved in a formal, multi-laboratory validation study sponsored by the European Cosmetics Association (COLIPA) under the auspices of the European Centre for the Validation of Alternative Methods (ECVAM). The EpiOcular-EIT, together with EpiOcular's long history of reproducibility and proven utility for ultra-mildness testing, make EpiOcular a useful model for addressing current legislation related to animal use in the testing of potential ocular irritants.


Assuntos
Alternativas aos Testes com Animais , Olho/efeitos dos fármacos , Irritantes/toxicidade , Testes de Toxicidade/métodos , Cosméticos , Humanos , Rotulagem de Produtos , Controle de Qualidade
15.
Altern Lab Anim ; 39(4): 365-87, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21942548

RESUMO

In 2009, the Bovine Corneal Opacity and Permeability (BCOP) test was accepted by the regulatory bodies for the identification of corrosive and severe ocular irritants (Global Harmonised System [GHS] Category 1). However, no in vitro test is currently accepted for the differentiation of ocular irritants (GHS Category 2) and non-irritants (GHS No Category). Human reconstructed tissue models have been suggested for incorporation into a tiered testing strategy to ultimately replace the Draize rabbit eye irritation test (OECD TG 405). The purpose of this study was to evaluate whether the EpiOcular(TM) reconstructed cornea-like tissue model and the COLIPA pre-validated EpiOcular Eye Irritation Test (EpiOcular-EIT) could be used as suitable components of this testing strategy. The in-house validation of the EpiOcular-EIT was performed by using 60 test substances, including a broad variety of chemicals and formulations for which in vivo data (from the Draize rabbit eye irritation test) were available. The test substances fell into the following categories: 18 severe irritants/corrosives (Category 1), 21 irritants (Category 2), and 21 non-irritants (No Category). Test substances that decreased tissue viability to ≤ 60% (compared to the negative control tissue) were considered to be eye irritants (Category 1/2). Test substances resulting in tissue viability of > 60% were considered to be non-irritants (No Category). For the assessed dataset and the classification cut-off of 60% viability, the EpiOcular-EIT provided 98% and 84% sensitivity, 64% and 90% specificity, and 85% and 86% overall accuracy for the literature reference and BASF proprietary substances, respectively. Applying a 50% tissue viability cut-off to distinguish between irritants and non-irritants resulted in 93% and 82% sensitivity, 68% and 100% specificity, and 84% and 88% accuracy for the literature reference and BASF proprietary substances, respectively. Further, in the EpiOcular-EIT (60% cut-off), 100% of severely irritating substances under-predicted by the BCOP assay were classified as Category 1/2. The results obtained in this study, based on 60 test substances, indicate that the EpiOcular-EIT and the BCOP assay can be combined in a testing strategy to identify strong/severe eye irritants (Category 1), moderate and mild eye irritants (Category 2), and non-irritants (No Category) in routine testing. In particular, when the bottom-up strategy with the 60% viability cut-off was employed, none of the severely irritating substances (Category 1) were under-predicted to be non-irritant. Sensitivity for Category 1/2 substances was 100% for literature reference substances and 89% for BASF SE proprietary substances.


Assuntos
Opacidade da Córnea/induzido quimicamente , Olho/efeitos dos fármacos , Irritantes/toxicidade , Testes de Toxicidade/métodos , Animais , Bovinos , Humanos , Permeabilidade , Coelhos
16.
ALTEX ; 38(3): 419-430, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33497461

RESUMO

Medical devices must be tested before marketing in accordance with ISO EN 10993-10 in order to avoid skin sensi­tization. This standard predominantly refers to the in vivo test but does not exclude the use of in vitro methods that have been sufficiently technically and scientifically validated for medical device testing. It is foreseen that, due to the complexity of the sensitization endpoint, a combination of several methods will be needed to address all key events occurring in the sensitization process. The objective of this pilot study was to evaluate the sensitization potential of selected medical devices using a combination of in chemico (DPRA, OECD TG 442C) and in vitro (LuSens, OECD TG 442D) methods in comparison with the in vivo (LLNA DA, OECD TG 442A) method and to suggest a possible testing strategy for the safety assessment of medical device extracts. Overall, one of the 42 tested samples exhibited positive results in all employed test methods, while 33 samples were predicted as non-sensitizing in all three performed methods. This study demonstrated good agreement between in vitro and in vivo results regarding non-sensitizing samples; however, some discrepancies in positive classification were recorded. A testing strategy is suggested in which negative results are accepted and any positive results in the in chemico or in vitro tests are followed up with a third in vitro test and evaluated in accordance with the "2 out of 3 approach". This strategy may reduce and replace animal use for testing the sensitization potential of medical devices.


Assuntos
Alternativas aos Testes com Animais , Dermatite Alérgica de Contato , Animais , Bioensaio , Técnicas In Vitro , Projetos Piloto , Pele
17.
Toxicology ; 458: 152846, 2021 06 30.
Artigo em Inglês | MEDLINE | ID: mdl-34216698

RESUMO

The 3Rs concept, calling for replacement, reduction and refinement of animal experimentation, is receiving increasing attention around the world, and has found its way to legislation, in particular in the European Union. This is aligned by continuing high-level efforts of the European Commission to support development and implementation of 3Rs methods. In this respect, the European project called "ONTOX: ontology-driven and artificial intelligence-based repeated dose toxicity testing of chemicals for next generation risk assessment" was recently initiated with the goal to provide a functional and sustainable solution for advancing human risk assessment of chemicals without the use of animals in line with the principles of 21st century toxicity testing and next generation risk assessment. ONTOX will deliver a generic strategy to create new approach methodologies (NAMs) in order to predict systemic repeated dose toxicity effects that, upon combination with tailored exposure assessment, will enable human risk assessment. For proof-of-concept purposes, focus is put on NAMs addressing adversities in the liver, kidneys and developing brain induced by a variety of chemicals. The NAMs each consist of a computational system based on artificial intelligence and are fed by biological, toxicological, chemical and kinetic data. Data are consecutively integrated in physiological maps, quantitative adverse outcome pathway networks and ontology frameworks. Supported by artificial intelligence, data gaps are identified and are filled by targeted in vitro and in silico testing. ONTOX is anticipated to have a deep and long-lasting impact at many levels, in particular by consolidating Europe's world-leading position regarding the development, exploitation, regulation and application of animal-free methods for human risk assessment of chemicals.


Assuntos
Inteligência Artificial , Ontologia Genética , Testes de Toxicidade , Alternativas aos Testes com Animais , Animais , Simulação por Computador , União Europeia , Humanos , Técnicas In Vitro , Medição de Risco
18.
Contact Dermatitis ; 62(2): 109-16, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20136894

RESUMO

BACKGROUND: Efforts to replace the rabbit skin irritation test have been underway for many years, encouraged by the EU Cosmetics Directive and REACH. Recently various in vitro tests have been developed, evaluated and validated. OBJECTIVE: A key difficulty in confirming the validity of in vitro methods is that animal data are scarce and of limited utility for prediction of human effects, which adversely impacts their acceptance. This study examines whether in vivo or in vitro data most accurately predicted human effects. METHODS: Using the 4-hr human patch test (HPT) we examined a number of chemicals whose EU classification of skin irritancy is known to be borderline, or where in vitro methods provided conflicting results. RESULTS: Of the 16 chemicals classified as irritants in the rabbit, only five substances were found to be significantly irritating to human skin. Concordance of the rabbit test with the 4-hr HPT was only 56%, whereas concordance of human epidermis models with human data was 76% (EpiDerm) and 70% (EPISKIN). CONCLUSIONS: The results confirm observations that rabbits overpredict skin effects in humans. Therefore, when validating in vitro methods, all available information, including human data, should be taken into account before making conclusions about their predictive capacity.


Assuntos
Irritantes/efeitos adversos , Testes do Emplastro/normas , Testes de Irritação da Pele/normas , Pele/efeitos dos fármacos , Alternativas aos Testes com Animais/normas , Animais , Bioensaio/normas , Cosméticos/efeitos adversos , Reações Falso-Positivas , Humanos , Valor Preditivo dos Testes , Coelhos
19.
Artigo em Inglês | MEDLINE | ID: mdl-32850693

RESUMO

Microphysiometry has proved to be a useful tool for monitoring the energy metabolism of living cells and their interactions with other cells. The technique has mainly been used for monitoring two-dimensional (2D) monolayers of cells. Recently, our group showed that it is also possible to monitor the extracellular acidification rate and transepithelial electrical resistance (TEER) of 3D skin constructs in an automated assay maintaining an air-liquid interface (ALI) with a BioChip extended by 3D-printed encapsulation. In this work, we present an optimized multichannel intestine-on-a-chip for monitoring the TEER of the commercially available 3D small intestinal tissue model (EpiIntestinalTM from MatTek). Experiments are performed for 1 day, during which a 60 min cycle is repeated periodically. Each cycle consists of three parts: (1) maintain ALI; (2) application of the measurement medium or test substance; and (3) the rinse cycle. A cytotoxic and barrier-disrupting benchmark chemical (0.2% sodium dodecyl sulfate) was applied after 8 h of initial equilibration. This caused time-dependent reduction of the TEER, which could not be observed with typical cytotoxicity measurement methods. This work represents a proof-of-principle of multichannel time-resolved TEER monitoring of a 3D intestine model using an automated ALI. Reconstructed human tissue combined with the Intelligent Mobile Lab for In vitro Diagnostic technology represents a promising research tool for use in toxicology, cellular metabolism studies, and drug absorption research.

20.
ALTEX ; 37(3): 441-450, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32113185

RESUMO

Despite a continuous increase of commercial products containing nanoparticles, only few materials are currently used in such large amounts, forms and sizes as titanium dioxide - TiO2. Besides its use in cosmetics, food industry and biomedicine, TiO2 nanoparticles (NPs) are also used as highly efficient photocatalysts due to their unique ability to convert complex organic materials to carbon dioxide, water and simple mineral acids via complex radical and electron transfer reactions. The main objective of the current project was to assess the potential dermal effect (phototoxicity and skin toxicity) of TiO2 nanosheets (TIG-800) synthesized from the lyophilized aqueous colloids of peroxo-titanic acid by high-temperature treatment. The effect was examined on reconstructed human skin model EpiDerm in the test pre-validated by ECVAM and adopted into the ICH S10 guidelines for the preclinical photo-safety assessment of drugs. In addition, two further commercial samples of nanocrystalline TiO2, namely Aeroxide P25 and Eusolex T-2000, and six benchmark materials from pre-validation studies were tested. None of the TiO2 NPs tested in the study caused acute phototoxicity or cytotoxicity in the reconstructed 3D tissues up to the highest concentration tested. The prediction of photo-irritation potency for the benchmark chemicals was comparable to previous studies. For some of the tested materials, we identified reasons for false negative results or variability in previously published datasets by improved dosing, conditions of irradiation, and choice of suitable solvents. The method proved its suitability for photo-irritation assessment of topically applied materials.


Assuntos
Sobrevivência Celular/efeitos dos fármacos , Dermatite Fototóxica , Nanoestruturas , Pele/efeitos dos fármacos , Titânio/toxicidade , Alternativas aos Testes com Animais , Humanos , Modelos Biológicos , Pele/citologia , Alicerces Teciduais , Titânio/química
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa