Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 18(11)2018 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-30423897

RESUMO

Ammonia is an essential biomarker for noninvasive diagnosis of liver malfunction. Therefore, selective detection of ammonia is essential for medical application. Here, we demonstrate a portable device to selectively detect sub-ppm ammonia gas. The presented gas sensor is composed of a Pt coating on top of an ultrathin Indium nitrite (InN) epilayer with a lower detection limit of 0.2 ppm, at operating temperature of 200 °C, and detection time of 1 min. The sensor connected with the external filter of nonpolar 500 CS silicone oil to diagnose liver malfunction. The absorption of 0.7 ppm acetone and 0.4 ppm ammonia gas in 10 cc silicone oil is 80% (0.56 ppm) and 21.11% (0.084 ppm), respectively, with a flow rate of 10 cc/min at 25 °C. The absorption of acetone gas is 6.66-fold higher as compared to ammonia gas. The percentage variation in response for 0.7 ppm ammonia and 0.7 ppm acetone with and without silicone oil on InN sensor is 17.5% and 4%, and 22.5%, and 14% respectively. Furthermore, the percentage variation in response for 0.7 ppm ammonia gas with silicone oil on InN sensor is 4.3-fold higher than that of 0.7 ppm acetone. The results show that the InN sensor is suitable for diagnosis of liver malfunction.


Assuntos
Amônia/isolamento & purificação , Técnicas Biossensoriais , Testes Respiratórios , Óleos de Silicone/química , Acetona/química , Amônia/química , Humanos , Índio/química , Limite de Detecção , Nitritos/química
2.
Sensors (Basel) ; 12(6): 7157-68, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22969342

RESUMO

An indium nitride (InN) gas sensor of 10 nm in thickness has achieved detection limit of 0.4 ppm acetone. The sensor has a size of 1 mm by 2.5 mm, while its sensing area is 0.25 mm by 2 mm. Detection of such a low acetone concentration in exhaled breath could enable early diagnosis of diabetes for portable physiological applications. The ultrathin InN epilayer extensively enhances sensing sensitivity due to its strong electron accumulation on roughly 5-10 nm deep layers from the surface. Platinum as catalyst can increase output current signals by 2.5-fold (94 vs. 37.5 µA) as well as reduce response time by 8.4-fold (150 vs. 1,260 s) in comparison with bare InN. More, the effect of 3% oxygen consumption due to breath inhalation and exhalation on 2.4 ppm acetone gas detection was investigated, indicating that such an acetone concentration can be analyzed in air.


Assuntos
Acetona/análise , Técnicas Biossensoriais/instrumentação , Diabetes Mellitus/diagnóstico , Gases/análise , Índio , Transistores Eletrônicos , Eletricidade , Humanos , Oxigênio/química , Platina/química
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa