Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-37266863

RESUMO

In recent years, the insertion/deletion (InDel) polymorphism has become a preferred genetic marker in forensic genetics due to its low mutation rates and small amplicon sizes. In this study, a 36-InDelplex identification panel, consisting of autosomal 34 InDel loci, 1 Y InDel locus, and amelogenin, was developed, and gene frequencies in the Turkish population were determined. The loci of the InDel panel with global minimum allele frequencies (MAF) ≥ 0.4 were selected from the 1000 Genomes Project Phase 3 data. The amplicon sizes of the loci were designed in the range of 69-252 bp. In the validation study of the developed panel, analysis threshold, dynamic range, sensitivity, stochastic threshold, inhibitor tolerance, and reproducibility parameters were studied by following the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines. The sensitivity studies indicated that complete and reliable InDel profiles could be obtained with 0.25 ng of DNA. A population study was evaluated using 250 samples from Turkey. The mean observed heterozygosity ratio (Ho) of all loci was 0.48. The combined discrimination power (CPD) is 0.999999999990867 and the combined exclusion probability (CPE) was 0.9930. The population comparison was also made using Turkish and the five major populations from the 1000 Genomes Phase 3 populations' data (Africa, Europe, East Asia, South Asia, and America). In conclusion, the results showed that the 36-InDelplex panel is a reliable, sensitive, and accurate system that is suitable for human identification and population genetics purposes.

2.
Eur J Hum Genet ; 13(8): 953-8, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15886713

RESUMO

Recently, preimplantation genetic diagnosis (PGD) has been considered for several indications beyond its original purpose, not only to test embryos for genetic disease but also to select embryos for a nondisease trait, such as specific human leukocyte antigen (HLA) genotypes, related to immune compatibility with an existing affected child in need of a haematopoetic stem cell (HSC) transplant. We have optimized an indirect single-cell HLA typing protocol based on a multiplex fluorescent polymerase chain reaction (PCR) of short tandem repeat (STR) markers scattered throughout the HLA complex. The assay was clinically applied in 60 cycles from 45 couples. A conclusive HLA-matching diagnosis was achieved in 483/530 (91.1%) of the embryos tested. In total, 74 (15.3%) embryos revealed an HLA match with the affected siblings, 55 (11.4%) of which resulted unaffected and 46 (9.5%) have been transferred to the patients. Nine pregnancies were achieved, five healthy HLA-matched children have already been delivered and cord blood HSCs, were transplanted to three affected siblings, resulting in a successful haematopoietic reconstruction.


Assuntos
Antígenos HLA/genética , Teste de Histocompatibilidade/métodos , Diagnóstico Pré-Implantação/métodos , Feminino , Haplótipos , Humanos , Gravidez , Sequências de Repetição em Tandem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa