Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Magn Reson Med ; 71(5): 1896-905, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23813415

RESUMO

PURPOSE: The process of invasion and metastasis formation of tumor cells can be studied by following the migration of labeled cells over prolonged time periods. This report investigates the applicability of iron oxide nanoparticles as a magnetic resonance imaging (MRI) contrast agent for cell labeling. METHODS: γFe2 O3 nanoparticles prepared with direct flame spray pyrolysis are biofunctionalized with poly-l-lysine (PLL). The nanoparticles within the cells were observed with transmission electron microscopy, bright-field microscopy, and magnetorelaxometry. MRI of labeled cells suspended in agarose was used to estimate the detection limit. RESULTS: PLL-coated particles are readily taken up, stored in intracellular clusters, and gradually degraded by the cells. During cell division, the nanoparticle clusters are divided and split between daughter cells. The MRI detection limit was found to be 25 cells/mm(3) for R2*, and 70 cells/mm(3) for R2. The iron specificity, however, was higher for R2 images. Due to the degradation of intracellular γFe2 O3 to paramagnetic iron ions within 13 days, the R1, R2, and R2* contrast gradually decreased over this time period to approximately 50% of its initial value. CONCLUSIONS: These results suggest that PLL-coated γFe2 O3 nanoparticles can be used as an MRI contrast agent for long-term studies of cell migration. Magn Reson Med 71:1896-1905, 2014. © 2013 Wiley Periodicals, Inc.


Assuntos
Rastreamento de Células/métodos , Imageamento por Ressonância Magnética/métodos , Nanopartículas de Magnetita/química , Neoplasias Experimentais/patologia , Animais , Linhagem Celular Tumoral , Meios de Contraste/química , Humanos , Nanopartículas de Magnetita/ultraestrutura , Invasividade Neoplásica , Tamanho da Partícula , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Coloração e Rotulagem/métodos , Suínos
2.
Med Phys ; 40(8): 082301, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23927344

RESUMO

PURPOSE: Flexible radiofrequency (RF) surface coils used in simultaneous PET/MR imaging are currently disregarded in PET attenuation correction (AC) since their position and individual geometry are unknown in whole-body patient scans. The attenuation of PET emission data due to the presence of RF surface coils has been investigated by several research groups but so far no automatic approach for the incorporation of RF surface coils into PET AC has been described. In this work, an algorithm is presented and evaluated which automatically determines the position of multiple RF surface coils and corrects for their attenuation of the PET emission data. METHODS: The presented algorithm nonrigidly registers pre-acquired CT-based three-dimensional attenuation templates of RF surface coils into attenuation maps used for PET AC. Transformation parameters are obtained by nonrigid B-spline landmark registration of marker positions in the CT-based attenuation templates of the RF surface coils to marker positions in the current MR images of the patient. The use of different marker patterns enables the registration algorithm to distinguish multiple partly overlapping RF surface coils. To evaluate the registration algorithm, two different PET emission scans of a NEMA standard body phantom with six active lesions and of a large rectangular body phantom were performed on an integrated whole-body PET/MR scanner. The phantoms were scanned with and without one (NEMA phantom scan) or three (large body phantom scan) flexible six-channel RF surface coils placed on top. Additionally, the accuracy and performance of the algorithm were evaluated on volunteer scans (n=5) and on a patient scan using a typical clinical setup of three RF surface coils. RESULTS: Overall loss of true counts due to the presence of the RF surface coils was 5.1% for the NEMA phantom, 3.6% for the large body phantom, and 2.1% for the patient scan. Considerable local underestimation of measured activity concentration up to 15.4% in the top part of the phantoms and 15.5% for a lesion near the body surface of the patient was measured close to the high attenuating hardware components of the RF coils. The attenuation maps generated by the registration algorithm reduced the quantification errors due to the RF surface coils to values ranging from -3.9% to 4.3%. Concerning the volunteer examinations, the attenuation templates of the three RF surface coils were registered to their correct positions with an overall accuracy of about 3 mm. CONCLUSIONS: The presence of flexible RF surface coils leads to considerable local errors in the simultaneously measured PET activity concentration up to 15.5% especially in regions close to the coils. The presented automatic algorithm accurately and reliably reduces the PET quantification errors caused by multiple partly overlapping flexible RF surface coils to values of 4.3% or better.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imagem Multimodal/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Ondas de Rádio , Adulto , Algoritmos , Automação , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa