1.
Circulation ; 102(13): 1484-9, 2000 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-11004137

RESUMO

BACKGROUND: The "edge effect," late lumen loss at the margins of the treated segment, has become an important issue in the field of coronary brachytherapy. The aim of the present study was to assess the edge effect in noninjured margins adjacent to the irradiated segments after catheter-based intracoronary beta-irradiation. METHODS AND RESULTS: Fifty-three vessels were assessed by means of 3-dimensional intravascular ultrasound after the procedure and at 6- to 8-month follow-up. Fourteen vessels (placebo group) did not receive radiation (sham source), whereas 39 vessels were irradiated. In the irradiated group, 48 edges (5 mm in length) were identified as noninjured, whereas 18 noninjured edges were selected in the placebo group. We compared the volumetric intravascular ultrasound measurements of the noninjured edges of the irradiated vessels with the fully irradiated nonstented segments (IRS, n=27) (26-mm segments received the prescribed 100% isodose) and the noninjured edges of the vessels of the placebo patients. The lumen decreased (6 mm(3)) in the noninjured edges of the irradiated vessels at follow-up (P:=0. 001). We observed a similar increase in plaque volume in all segments: noninjured edges of the irradiated group (19.6%), noninjured edges of the placebo group (21.5%), and IRS (21.0%). The total vessel volume increased in the IRS in the 3 groups. No edge segment was subject to repeat revascularization. CONCLUSIONS: The edge effect occurs in the noninjured margins of radiation source train in both irradiated and placebo patients. Thus, low-dose radiation may not play an important role in this phenomenon, whereas nonmeasurable device injury may be considered a plausible alternative explanation.


Assuntos
Angioplastia com Balão , Braquiterapia/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/efeitos da radiação , Partículas beta , Angiografia Coronária , Relação Dose-Resposta à Radiação , Humanos , Ultrassonografia
2.
Circulation ; 103(1): 14-7, 2001 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-11136678

RESUMO

BACKGROUND: Restenosis after conventional stenting is almost exclusively caused by neointimal hyperplasia. Beta-particle-emitting radioactive stents decrease in-stent neointimal hyperplasia at 6-month follow-up. The purpose of this study was to evaluate the 1-year outcome of (32)P radioactive stents with an initial activity of 6 to 12 microCi using serial quantitative coronary angiography and volumetric ECG-gated 3D intravascular ultrasound (IVUS). METHODS AND RESULTS: Of 40 patients undergoing initial stent implantation, 26 were event-free after the 6-month follow-up period and 22 underwent repeat catheterization and IVUS at 1 year; they comprised half of the study population. Significant luminal deterioration was observed within the stents between 6 months and 1 year, as evidenced by a decrease in the angiographic minimum lumen diameter (-0.43+/-0.56 mm; P:=0.028) and in the mean lumen diameter in the stent (-0.55+/-0. 63 mm; P:=0.001); a significant increase in in-stent neointimal hyperplasia by IVUS (18.16+/-12.59 mm(3) at 6 months to 27.75+/-11. 99 mm(3) at 1 year; P:=0.001) was also observed. Target vessel revascularization was performed in 5 patients (23%). No patient experienced late occlusion, myocardial infarction, or death. By 1 year, 21 of the initial 40 patients (65%) remained event-free. CONCLUSIONS: Neointimal proliferation is delayed rather than prevented by radioactive stent implantation. Clinical outcome 1 year after the implantation of stents with an initial activity of 6 to 12 microCi is not favorable when compared with conventional stenting.


Assuntos
Braquiterapia , Doença das Coronárias/radioterapia , Oclusão de Enxerto Vascular/prevenção & controle , Radioisótopos de Fósforo/uso terapêutico , Stents , Adulto , Idoso , Braquiterapia/efeitos adversos , Braquiterapia/instrumentação , Angiografia Coronária , Doença das Coronárias/patologia , Doença das Coronárias/cirurgia , Endossonografia , Feminino , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Fósforo/efeitos adversos , Doses de Radiação , Falha de Tratamento , Resultado do Tratamento
3.
Circulation ; 101(21): 2467-71, 2000 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-10831519

RESUMO

BACKGROUND: A recognized limitation of endovascular beta-radiation therapy is the development of new stenosis at the edges of the irradiated area. The combination of injury and low-dose radiation may be the precursor of this phenomenon. We translated the radio-oncological concept of "geographic miss" to define cases in which the radiation source did not fully cover the injured area. The aims of the study were to determine the incidence and causes of geographic miss and evaluate the impact of this inadequate treatment on the outcome of patients treated with intracoronary beta-radiation. METHODS AND RESULTS: We analyzed 50 consecutive patients treated with beta-radiation after percutaneous coronary intervention. The prescribed dose ranged between 12 and 20 Gy at 2 mm from the source axis. By means of quantitative coronary angiography, the irradiated segment (IRS) and both edges were studied before and after intervention and at 6-month follow-up. Edges that were injured during the procedure constituted the geographic miss edges. Twenty-two edges were injured during the intervention, mainly because of procedural complications that extended the treatment beyond the margins of the IRS. Late loss was significantly higher in geographic miss edges than in IRSs and uninjured edges (0.84+/-0.6 versus 0.15+/-0.4 and 0.09+/-0.4 mm, respectively; P<0.0001). Similarly, restenosis rate was significantly higher in the injured edges (10% within IRS, 40.9% in geographic miss edges, and 1.9% in uninjured edges; P<0.001). CONCLUSIONS: These data support the hypothesis that the combination of injury and low-dose beta-radiation induces deleterious outcome.


Assuntos
Braquiterapia/métodos , Doença das Coronárias/radioterapia , Angioplastia Coronária com Balão , Partículas beta , Angiografia Coronária , Seguimentos , Humanos , Recidiva , Estudos Retrospectivos , Falha de Tratamento
4.
Circulation ; 101(21): 2472-7, 2000 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-10831520

RESUMO

BACKGROUND: Inhomogeneity of dose distribution and anatomic aspects of the atherosclerotic plaque may influence the outcome of irradiated lesions after balloon angioplasty (BA). We evaluated the influence of delivered dose and morphological characteristics of coronary stenoses treated with beta-radiation after BA. METHODS AND RESULTS: Eighteen consecutive patients treated according to the Beta Energy Restenosis Trial 1.5 were included in the study. The site of angioplasty was irradiated with the use of a beta-emitting (90)Sr/(90)Y source. With the side branches used as anatomic landmarks, the irradiated area was identified and volumetric assessment was performed by 3D intracoronary ultrasound imaging after treatment and at 6 months. The type of tissue, the presence of dissection, and the vessel volumes were assessed every 2 mm within the irradiated area. The minimal dose absorbed by 90% of the adventitial volume (D(v90)Adv) was calculated in each 2-mm segment. Diffuse calcified subsegments and those containing side branches were excluded. Two hundred six coronary subsegments were studied. Of those, 55 were defined as soft, 129 as hard, and 22 as normal/intimal thickening. Plaque volume showed less increase in hard segments as compared with soft and normal/intimal thickening segments (P<0.0001). D(v90)Adv was associated with plaque volume at follow-up after a polynomial equation with linear and nonlinear components (r = 0.71; P = 0.0001). The multivariate regression analysis identified the independent predictors of the plaque volume at follow-up: plaque volume after treatment, D(v90)Adv, and type of plaque. CONCLUSIONS: Residual plaque burden, delivered dose, and tiss composition play a fundamental role in the volumetric outcome at 6-month follow-up after beta-radiation therapy and BA.


Assuntos
Angioplastia Coronária com Balão , Braquiterapia/métodos , Doença das Coronárias/terapia , Partículas beta , Terapia Combinada , Doença das Coronárias/patologia , Relação Dose-Resposta à Radiação , Humanos , Dosagem Radioterapêutica , Análise de Regressão , Resultado do Tratamento , Ultrassonografia de Intervenção
5.
Circulation ; 105(5): 550-3, 2002 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-11827917

RESUMO

BACKGROUND: Radioactive stents with an activity of 0.75 to 12 microCi have shown >40% edge restenosis due to neointimal hyperplasia and negative remodeling. This trial evaluated whether radioactive Cold Ends stents might resolve edge restenosis by preventing remodeling at the injured extremities. METHODS AND RESULTS: The 25-mm long (15-mm radioactive center and 5-mm nonradioactive ends) Cold Ends stents had an activity of 3 to 12 microCi at implantation. Forty-three stents were implanted in 43 patients with de novo native coronary artery disease. Two procedural, 1 subacute, and 1 late stent thrombosis occurred. A restenosis rate of 22% was observed with a shift of the restenosis, usually occurring at the stent edges of radioactive stents, into the Cold Ends stents. The most severe restenosis occurred at the transition zone from radioactive to nonradioactive segments, a region located in dose fall-off. CONCLUSION: Cold Ends stents did not resolve edge restenosis.


Assuntos
Implante de Prótese Vascular/efeitos adversos , Braquiterapia/instrumentação , Angiografia Coronária , Doença da Artéria Coronariana/cirurgia , Oclusão de Enxerto Vascular/etiologia , Stents/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angina Pectoris/etiologia , Braquiterapia/métodos , Doença da Artéria Coronariana/tratamento farmacológico , Trombose Coronária/etiologia , Relação Dose-Resposta à Radiação , Feminino , Fibrinolíticos/uso terapêutico , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Fósforo/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Resultado do Tratamento
6.
Circulation ; 100(8): 789-92, 1999 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-10458712

RESUMO

BACKGROUND: Intracoronary brachytherapy appears to be a promising technology to prevent restenosis. Presently, limited data are available regarding the late safety of this therapeutic modality. The aim of the study was to determine the incidence of late (>1 month) thrombosis after PTCA and radiotherapy. METHODS AND RESULTS: From April 1997 to March 1999, we successfully treated 108 patients with PTCA followed by intracoronary beta-radiation. Ninety-one patients have completed at least 2 months of clinical follow-up. Of these patients, 6.6% (6 patients) presented with sudden thrombotic events confirmed by angiography 2 to 15 months after intervention (2 balloon angioplasty and 4 stent). Some factors (overlapping stents, unhealed dissection) may have triggered the thrombosis process, but the timing of the event is extremely unusual. Therefore, the effect of radiation on delaying the healing process and maintaining a thrombogenic coronary surface is proposed as the most plausible mechanism to explain such late events. CONCLUSIONS: Late and sudden thrombosis after PTCA followed by intracoronary radiotherapy is a new phenomenon in interventional cardiology.


Assuntos
Angioplastia Coronária com Balão , Braquiterapia/efeitos adversos , Doença das Coronárias/terapia , Trombose Coronária/etiologia , Idoso , Braquiterapia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Stents
7.
Circulation ; 102(12): 1434-9, 2000 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-10993864

RESUMO

BACKGROUND: Recent reports demonstrate that intracoronary radiation affects not only neointimal formation but also vascular remodeling. Radioactive stents and catheter-based techniques deliver radiation in different ways, suggesting that different patterns of remodeling after each technique may be expected. METHODS AND RESULTS: We analyzed remodeling in 18 patients after conventional stent implantation, 16 patients after low-activity radioactive stent implantation, 16 patients after higher activity radioactive stent implantation, and, finally, 17 patients who underwent catheter-based radiation followed by conventional stent implantation. Intravascular ultrasound with 3D reconstruction was used after stent implantation and at the 6-month follow-up to assess remodeling within the stent margins and at its edges. Preprocedural characteristics were similar between groups. In-stent neointimal hyperplasia (NIH) was inhibited by high-activity radioactive stent implantation (NIH 9.0 mm(3)) and by catheter-based radiation followed by conventional stent implantation (NIH 6.9 mm(3)) compared with low-activity radioactive stent implantation (NIH 21.2 mm(3)) and conventional stent implantation (NIH 20.8 mm(3)) (P:=0.008). No difference in plaque or total vessel volume was seen behind the stent in the conventional, low-activity, or high-activity stent implantation groups. However, significant increases in plaque behind the stent (15%) and in total vessel volume (8%) were seen in the group that underwent catheter-based radiation followed by conventional stent implantation. All 4 groups demonstrated significant late lumen loss at the stent edges; however, edge restenosis was seen only in the group subjected to high-activity stent implantation and appeared to be due to an increase in plaque and, to a lesser degree, to negative remodeling. CONCLUSIONS: Distinct differences in the patterns of remodeling exist between conventional, radioactive, and catheter-based radiotherapy with stenting.


Assuntos
Doença das Coronárias/terapia , Stents , Túnica Íntima/patologia , Adulto , Idoso , Doença das Coronárias/patologia , Doença das Coronárias/radioterapia , Feminino , Seguimentos , Humanos , Hiperplasia/prevenção & controle , Hiperplasia/radioterapia , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Recidiva , Estudos Retrospectivos , Túnica Íntima/efeitos da radiação
8.
Circulation ; 100(16): 1684-9, 1999 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-10525486

RESUMO

BACKGROUND: This study represents the Heart Center Rotterdam's contribution to the Isostents for Restenosis Intervention Study, a nonrandomized multicenter trial evaluating the safety and feasibility of the radioactive Isostent in patients with single coronary artery disease. Restenosis after stent implantation is primarily caused by neointimal hyperplasia. In animal studies, beta-particle-emitting radioactive stents decrease neointimal hyperplasia by inhibiting smooth muscle cell proliferation. METHODS AND RESULTS: The radioisotope (32)P, a beta-particle emitter with a half-life of 14.3 days, was directly embedded into the Isostent. The calculated range of radioactivity was 0.75 to 1.5 microCi. Quantitative coronary angiography measurements were performed before and after the procedure and at 6-month follow-up. A total of 31 radioactive stents were used in 26 patients; 30 (97%) were successfully implanted, and 1 was embolized. Treated lesions were in the left anterior descending coronary artery (n=12), the right coronary artery (n=8), or the left circumflex coronary artery (n=6). Five patients received additional, nonradioactive stents. Treated lesion lengths were 13+/-4 mm, with a reference diameter of 2.93+/-0. 47 mm. Minimum lumen diameter increased from 0.87+/-0.28 mm preprocedure to 2.84+/-0.35 mm postprocedure. No in-hospital adverse cardiac events occurred. All patients received aspirin indefinitely and ticlopidine for 4 weeks. Twenty-three patients (88%) returned for 6-month angiographic follow-up; 17% of them had in-stent restenosis, and 13% had repeat revascularization. No restenosis was observed at the stent edges. Minimum lumen diameter at follow-up averaged 1.85+/-0.69 mm, which resulted in a late loss of 0.99+/-0. 59 mm and a late loss index of 0.53+/-0.35. No other major cardiac events occurred during the 6-month follow-up. CONCLUSIONS: The use of radioactive stents with an activity of 0.75 to 1.5 microCi is safe and feasible.


Assuntos
Braquiterapia , Doença das Coronárias/radioterapia , Stents , Adulto , Idoso , Aspirina/uso terapêutico , Partículas beta/uso terapêutico , Braquiterapia/efeitos adversos , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Seguimentos , Oclusão de Enxerto Vascular/epidemiologia , Oclusão de Enxerto Vascular/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Radioisótopos de Fósforo/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Stents/efeitos adversos , Ticlopidina/uso terapêutico
9.
Circulation ; 100(11): 1182-8, 1999 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-10484538

RESUMO

BACKGROUND: Endovascular radiation appears to inhibit intimal thickening after overstretching balloon injury in animal models. The effect of brachytherapy on vascular remodeling is unknown. The aim of the study was to determine the evolution of coronary vessel dimensions after intracoronary irradiation after successful balloon angioplasty in humans. METHODS AND RESULTS: Twenty-one consecutive patients treated with balloon angioplasty and beta-radiation according to the Beta Energy Restenosis Trial-1.5 were included in the study. Volumetric assessment of the irradiated segment and both edges was performed after brachytherapy and at 6-month follow-up. Intravascular ultrasound images were acquired by means of ECG-triggered pullback, and 3-D reconstruction was performed by automated edge detection, allowing the calculation of lumen, plaque, and external elastic membrane (EEM) volumes. In the irradiated segments, mean EEM and plaque volumes increased significantly (451+/-128 to 490.9+/-159 mm(3) and 201.2+/-59 to 241.7+/-74 mm(3); P=0.01 and P=0.001, respectively), whereas luminal volume remained unchanged (250.8+/-91 to 249.2+/-102 mm(3); P=NS). The edges demonstrated an increase in mean plaque volume (26.8+/-12 to 32. 6+/-10 mm(3), P=0.0001) and no net change in mean EEM volume (71. 4+/-24 to 70.9+/-24 mm(3), P=NS), resulting in a decrease in mean luminal volume (44.6+/-16 to 38.3+/-16 mm(3), P=0.01). CONCLUSIONS: A different pattern of remodeling is observed in coronary segments treated with beta-radiation after successful balloon angioplasty. In the irradiated segments, the adaptive increase of EEM volume appears to be the major contributor to the luminal volume at follow-up. Conversely, both edges showed an increase in plaque volume without a net change in EEM volume.


Assuntos
Angioplastia com Balão , Braquiterapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiologia , Partículas beta , Braquiterapia/métodos , Angiografia Coronária , Endossonografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
10.
Circulation ; 100(15): 1623-9, 1999 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-10517733

RESUMO

BACKGROUND: Abnormal endothelium-dependent coronary vasomotion has been reported after balloon angioplasty (BA), as well as after intracoronary radiation. However, the long-term effect on coronary vasomotion is not known. The aim of this study was to evaluate the long-term vasomotion of coronary segments treated with BA and brachytherapy. METHODS AND RESULTS: Patients with single de novo lesions treated either with BA followed by intracoronary beta-irradiation (according to the Beta Energy Restenosis Trial-1.5) or with BA alone were eligible. Of these groups, those patients in stable condition who returned for 6-month angiographic follow-up formed the study population (n=19, irradiated group and n=11, control group). Endothelium-dependent coronary vasomotion was assessed by selective infusion of serial doses of acetylcholine (ACh) proximally to the treated area. Mean luminal diameter was calculated by quantitative coronary angiography both in the treated area and in distal segments. Endothelial dysfunction was defined as a vasoconstriction after the maximal dose of ACh (10(-6) mol/L). Seventeen irradiated segments (89.5%) demonstrated normal endothelial function. In contrast, 10 distal nonirradiated segments (53%) and 5 control segments (45%) demonstrated endothelium-dependent vasoconstriction (-19+/-17% and -9.0+/-5%, respectively). Mean percentage of change in mean luminal diameter after ACh was significantly higher in irradiated segments (P=0.01). CONCLUSIONS: Endothelium-dependent vasomotion of coronary segments treated with BA followed by beta-radiation is restored in the majority of stable patients at 6-month follow-up. This functional response appeared to be better than those documented both in the distal segments and in segments treated with BA alone.


Assuntos
Angioplastia Coronária com Balão , Braquiterapia , Doença das Coronárias/terapia , Vasos Coronários/fisiopatologia , Endotélio Vascular/fisiopatologia , Radioterapia Adjuvante , Vasodilatação , Acetilcolina/farmacologia , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Partículas beta , Braquiterapia/instrumentação , Cateterismo Cardíaco , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/radioterapia , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/lesões , Vasos Coronários/efeitos da radiação , Endotélio Vascular/lesões , Endotélio Vascular/efeitos da radiação , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Óxido Nítrico/metabolismo , Estudos Prospectivos , Dosagem Radioterapêutica , Radioterapia Adjuvante/instrumentação , Vasodilatação/efeitos dos fármacos , Sistema Vasomotor/efeitos dos fármacos , Sistema Vasomotor/fisiopatologia
11.
J Am Coll Cardiol ; 36(4): 1274-9, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11028483

RESUMO

OBJECTIVES: The study systematically compared different measures of ST segment depression from the treadmill exercise test. BACKGROUND: The value of the treadmill exercise test for objectively measuring treatment effects is limited by random error in the measurement of ST depression and may be biased by regression to the mean or by the decision to terminate the test. METHODS: Treadmill exercise was performed in 21 subjects with ischemic heart disease 1 h after isosorbide dinitrate 10 mg or placebo in a double-blind randomized crossover study. A 12-lead electrocardiogram (ECG) was recorded every 30 s during and at peak exercise. The relative sample size needed to detect the nitrate effect was compared for different summary measures of ST depression. RESULTS: The ST depression measured from a single unmatched lead at longest equivalent sub-maximal exercise needed the lowest sample size to detect the nitrate effect in paired comparisons (p = 0.000006). Averaging over multiple leads or times did not improve detection of the nitrate effect. The rate of increase in ST depression (in mm/min) calculated by linear regression needed a similar sample size (x1.32, 95% CI 0.62 to 2.58). A larger sample size was needed for ST depression at peak exercise (x2.9, CI 1.3, 11.1) and exercise duration (x4.5, CI 1.5, 38). Time to 1-mm ST depression was the least efficient measurement (relative sample size x15.5, CI 1.6, >1,000). Comparison of matched leads resulted in >2-fold differences in estimates of the nitrate effect because of bias from regression to the mean. CONCLUSIONS: Maximal ST depression at longest equivalent sub-maximal exercise and the maximal rate of increase in ST depression had less bias and random variation than did other commonly used measures. The rate of increase in ST depression is preferred because it can be calculated in either paired or unpaired studies.


Assuntos
Eletrocardiografia/métodos , Teste de Esforço/normas , Isquemia Miocárdica/diagnóstico , Administração Oral , Idoso , Estudos Cross-Over , Interpretação Estatística de Dados , Diagnóstico Diferencial , Método Duplo-Cego , Eletrocardiografia/efeitos dos fármacos , Humanos , Dinitrato de Isossorbida/administração & dosagem , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Vasodilatadores/administração & dosagem
12.
J Am Coll Cardiol ; 34(4): 1067-74, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10520792

RESUMO

OBJECTIVES: We aimed to identify periprocedural quantitative coronary angiographic (QCA) variables that have predictive value on long-term angiographic results and to construct multivariate models using these variables for postprocedural prognosis. BACKGROUND: Coronary stent implantation has reduced the restenosis rate significantly as compared with balloon angioplasty in short de novo lesions in coronary arteries >3 mm in size. Although the postprocedural minimal luminal diameter (MLD) is known to have significant bearing on long-term angiographic results, no practically useful model exists for prediction of angiographic outcome based on the periprocedural QCA variables. METHODS: The QCA data from patients who underwent Palmaz-Schatz stent implantation for short (<15 mm) de novo lesions in coronary arteries >3 mm and completed six months of angiographic follow-up in the four prospective clinical trials (BENESTENT I, BENESTENT II pilot, BENESTENT II and MUSIC) were pooled. Multiple models were constructed using multivariate analysis. The Hosmer-Lemeshow goodness-of-fit test was used to identify the model of best fit, and this model was used to construct a reference chart for prediction of angiographic outcome on the basis of periprocedural QCA variables. RESULTS: Univariate analysis performed using QCA variables revealed that vessel size, MLD before and after the procedure, reference area before and after the procedure, minimal luminal cross-sectional area before and after the procedure, diameter stenosis after the procedure, area of plaque after the procedure and area stenosis after the procedure were significant predictors of angiographic outcome. Using multivariate analysis, the Hosmer-Lemeshow goodness-of-fit test showed that the model containing percent diameter stenosis after the procedure and vessel size best fit the data. A reference chart was then developed to calculate the expected restenosis rate. CONCLUSIONS: Restenosis rate after stent implantation for short lesions can be predicted using the variables percent diameter stenosis after the procedure and vessel size. This meta-analysis indicates that the concept of "the bigger the better" holds true for coronary stent implantation. Applicability of the model beyond short lesions should be tested.


Assuntos
Angioplastia Coronária com Balão , Angiografia Coronária , Doença das Coronárias/terapia , Processamento de Imagem Assistida por Computador , Stents , Adulto , Idoso , Angiografia Coronária/instrumentação , Doença das Coronárias/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Projetos Piloto , Prognóstico , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Recidiva , Resultado do Tratamento
13.
J Am Coll Cardiol ; 36(5): 1536-41, 2000 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-11079655

RESUMO

OBJECTIVES: The aims of the study were to determine the incidence of relocation of the minimal luminal diameter (MLD) after beta-radiation therapy following balloon angioplasty (BA) and to describe a new methodological approach to define the effect of brachytherapy on treated coronary stenoses. BACKGROUND: Luminal diameter of coronary lesions may increase over time following angioplasty and irradiation. As a result, the MLD at follow-up may be relocated from its location preintervention, which may induce misleading results when a restricted definition of the target segment by quantitative coronary angiography (QCA) is performed. METHODS: Patients treated with BA followed by intracoronary brachytherapy according to the Dose-Finding Study constituted the study population. A historical cohort of patients treated with BA was used as control group. To be included in the analysis, an accurate angiographic documentation of all instrumentations during the procedure was mandatory. In the irradiated patients, four regions were defined by QCA: vessel segment (VS), target segment (TS), injured segment (INS), and irradiated segment (IRS). RESULTS: Sixty-five patients from the Dose-Finding Study and 179 control patients were included. At follow-up, MLD was relocated more often in the radiation group (78.5% vs. 26.3%; p < 0.0001). The rate of >50% diameter stenosis differed among the four predefined regions: 3.1% in the TS; 7.7% in the INS; 9.2% in the IRS and 13.8% in the VS. CONCLUSIONS: Relocation of the MLD is commonly demonstrated after BA and brachytherapy, and it should be taken into account during the analysis of the results of radiation clinical trials.


Assuntos
Doença das Coronárias/patologia , Doença das Coronárias/radioterapia , Angioplastia com Balão , Cardiologia/métodos , Doença das Coronárias/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
14.
J Am Coll Cardiol ; 38(2): 415-20, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11499732

RESUMO

OBJECTIVES: We sought to determine the incidence and causes of geographical miss (GM) and to evaluate its impact on edge restenosis after intracoronary beta-radiation therapy. BACKGROUND: Edge restenosis is a limitation of intracoronary beta-radiation therapy. Geographical miss is the situation in which the radiation source does not fully cover the injured segment and may lead to edge restenosis. METHODS: We analyzed 175 vessels treated according to the Beta-Radiation In Europe (BRIE) study protocol. The effective irradiated segment (EIRS) and both edges were studied with quantitative coronary angiography. The edges of the EIRS that were injured constituted the GM edges. Restenosis was defined as diameter stenosis >50% at follow-up. Geographical miss was determined by simultaneous electrocardiographic-matched, side-by-side projection of the source and balloons deflated at the injury site, in identical angiographic projections surrounded by contrast. RESULTS: Geographical miss affected 41.2% of the edges and increased edge restenosis significantly compared with non-GM edges (16.3% vs. 4.3%, respectively, p = 0.004). Restenosis was increased both in the proximal (p = 0.05) and distal (p = 0.02) GM edges compared with noninjured edges. Geographical miss associated with stent injury significantly increased edge restenosis (p = 0.006), whereas GM related to balloon injury did not significantly increase edge restenosis (p = 0.35). The restenosis in the EIRS was similar between vessels with and without GM (24.3% and 21.6%, respectively, p = 0.8). CONCLUSIONS: Geographical miss is strongly associated with restenosis at the edges of the EIRS. This effect is more prominent when caused by stenting. Geographical miss does not increase restenosis in the EIRS.


Assuntos
Partículas beta , Braquiterapia/efeitos adversos , Doença das Coronárias/etiologia , Cardiopatias/radioterapia , Adulto , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Cateterismo Cardíaco , Doença das Coronárias/epidemiologia , Feminino , Cardiopatias/complicações , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Stents/efeitos adversos
15.
Am Heart J ; 140(4): 596-602, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11011332

RESUMO

BACKGROUND: Recently, a novel nonfluoroscopic 3-dimensional electromechanical mapping technique was introduced in the clinical arena. Although initial in vitro and in vivo studies suggested the reliability of the system in volumetric and hemodynamic evaluation of the left ventricle, no validation in human beings has been performed. METHODS: A nonfluoroscopic electromechanical mapping (NOGA, Biosense-Webster) procedure was performed in 44 patients. All patients received a contrast left ventriculogram during the same session. Volumetric (end-diastolic [EDV] and end-systolic volumes [ESV]) and hemodynamic (left ventricular ejection fraction [LVEF] and stroke volume) parameters of both systems were compared. RESULTS: Two uncomplicated pericardial effusions occurred with the first-generation mapping catheters. No procedural complications were noted with the new-generation mapping catheters. Significant correlations were found between mapping-derived and ventriculography-based measurements for both ESV (r = 0.67, P <.001) and LVEF (r = 0.78, P <.001). Absolute volumes, however, were only comparable for ESV (46.6 +/- 25.3 mL vs 48.8 +/- 37.0 mL, respectively; P =.13) but differed greatly for LVEF (35% +/- 13% vs 65% +/- 19%, respectively; P <.001), EDV (69.1 +/- 28.6 mL vs 125.9 +/- 53.4 mL, respectively; P <.001) and stroke volume (22.4 +/- 9.9 mL vs 77.1 +/- 33.7 respirations; P <.001). Moreover, Bland-Altman analysis showed the clinical noninterchangeability between these techniques for the measurement of hemodynamic parameters. CONCLUSION: Measurement of hemodynamic parameters with nonfluoroscopic mapping of the left ventricle is feasible and safe. The system provides data that strongly correlate but that are in clinical disagreement with angiographic data. Therefore the interchangeability of these techniques may be questioned.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Volume Cardíaco/fisiologia , Volume Sistólico/fisiologia , Função Ventricular , Algoritmos , Angiografia , Cateterismo Cardíaco , Estudos de Viabilidade , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador
16.
Am J Cardiol ; 86(4): 375-8, 2000 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-10946027

RESUMO

Limited data are available regarding the angiographic healing rate and physiologic impact of coronary artery dissections. Therefore, we studied the impact of coronary dissections on coronary flow velocity and outcome as well as their healing rate at 6-month follow-up balloon angioplasty. Of 297 patients who underwent balloon angioplasty, 225 underwent intracoronary Doppler measurements and 184 had Doppler and angiographic assessment at 6-month follow-up. Dissections were scored by an independent core lab (Cardialysis BV) and divided in 4 groups: mild (types A to B), moderate (type C), severe (D to F), and patients without dissections. Severe dissections (types D to F) were excluded from the analysis. Clinical, angiographic, and Doppler data were compared among the remaining 3 patient groups. From the 67 dissections detected after balloon angioplasty, only 3 (4.5%) remained unhealed at follow-up. Immediately after balloon angioplasty, the moderate dissection group was associated with a lower coronary flow velocity reserve than the patients with mild (2.16 +/- 0.60 vs 2.82 +/- 1.00, p = 0.037) or no dissections (2.16 +/- 0.60 vs 2.71 +/- 0.88, p = 0.046), respectively. In addition, higher recurrence of angina at 30 days was observed in the moderate group rather than in the mild group (5 [50%] vs 8 [16%], p = 0.0160) and in the patients without dissections (11 [12%], p = 0.007). After standard balloon angioplasty, the occurrence of unhealed dissections is a rare phenomenon. An impaired coronary flow reserve was observed after the development of nonocclusive type C dissections, which was associated with a worse short-term outcome.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Circulação Coronária , Doença das Coronárias/terapia , Vasos Coronários/lesões , Velocidade do Fluxo Sanguíneo , Angiografia Coronária , Doença das Coronárias/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Ecocardiografia Doppler , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Cicatrização
17.
Am J Cardiol ; 84(2): 135-40, 1999 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-10426328

RESUMO

The aim of this study was to determine the contribution of morphologic characteristics and location of plaque in remodeling of atherosclerotic coronary arteries. Consecutive intravascular ultrasound studies performed in native coronary arteries before an intervention were included in the study. Total vessel, lumen and plaque + media areas were measured at target lesion, and distal and proximal references. Remodeling index was calculated as target total vessel area/proximal reference total vessel area, and categorized into 3 groups based on relative total vessel-area ratio: (1) > 1.1 (group A, adequate remodeling); (2) 0.9 to 1.1 (group B, failure of compensatory enlargement); and (3) <0.9 (group C, coronary shrinkage). Eighty-nine narrowings were assessed in 80 intravascular ultrasound studies. Thirty-eight lesions (43%) were defined as soft and 51 (57%) as hard. Soft plaques were more prevalent in group A than in groups B and C (p = 0.001). Conversely, the arc of calcium was larger in group C lesions (p = 0.005). At distal segments, group A lesions were more prevalent than those in groups B and C, whereas at proximal segments group C lesions were more prevalent (p = 0.007). Multivariate analysis identified the arc of calcium and the location of plaque at distal segments as independent predictors of compensatory enlargement (odds ratio 0.94, 95% confidence interval 0.90 to 0.99; odds ratio 4.6; 95% confidence interval 1.4 to 15.7, respectively), whereas hard plaques were an independent predictor of coronary shrinkage (odds ratio 4.6; 95% confidence interval 1.7 to 12.5). In conclusion, composition and location of plaque appeared to be major determinants of vessel remodeling during the process of atherosclerosis.


Assuntos
Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Análise de Variância , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ultrassonografia de Intervenção
18.
Am J Cardiol ; 85(2): 135-9, 2000 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-10955366

RESUMO

Currently, several different designs of coronary stents are available. However, only a few of the new generation stents have been investigated in large randomized trials. Mechanical behavior of first-generation stents (Palmaz-Schatz, Gianturco-Roubin) may not be applied to the new designs. We investigated the chronic mechanical behavior (recoil) of 2 stents recently approved by the Food and Drug Administration (MULTILINK and NIR). Forty-eight patients with single-stent implantation (23 MULTILINK and 25 NIR) were assessed by means of volumetric 3-dimensional intravascular ultrasound analysis after the procedure and at 6-month follow-up. In addition, volumetric assessment of neointimal formation was performed. No significant chronic stent recoil was detected in both groups (delta MULTILINK stent volume: +5.6+/-41 mm3 [p = NS] and delta NIR stent volume + 2.1+/-26 mm3 [p = NS]). A similar degree of neointimal formation at 6 months was observed between the 2 stents (MULTILINK 46+/-31.9 mm3 vs NIR 39.9+/-27.6 mm3, p = NS). In conclusion, these 2 second-generation tubular stents did not show chronic recoil and appeared to promote similar proliferative response after implantation in human coronary arteries.


Assuntos
Stents , Túnica Íntima/citologia , Túnica Íntima/diagnóstico por imagem , Divisão Celular , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ultrassonografia
19.
Heart ; 83(3): 332-7, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10677416

RESUMO

OBJECTIVE: To evaluate the healing of balloon induced coronary artery dissection in individuals who have received beta radiation treatment and to propose a new intravascular ultrasound (IVUS) dissection score to facilitate the comparison of dissection through time. DESIGN: Retrospective study. SETTING: Tertiary referral centre. PATIENTS: 31 patients with stable angina pectoris, enrolled in the beta energy restenosis trial (BERT-1.5), were included. After excluding those who underwent stent implantation, the evaluable population was 22 patients. INTERVENTIONS: Balloon angioplasty and intracoronary radiation followed by quantitative coronary angiography (QCA) and IVUS. Repeat QCA and IVUS were performed at six month follow up. MAIN OUTCOME MEASURES: QCA and IVUS evidence of healing of dissection. Dissection classification for angiography was by the National Heart Lung Blood Institute scale. IVUS proven dissection was defined as partial or complete. The following IVUS defined characteristics of dissection were described in the affected coronary segments: length, depth, arc circumference, presence of flap, and dissection score. Dissection was defined as healed when all features of dissection had resolved. The calculated dose of radiation received by the dissected area in those with healed versus non-healed dissection was also compared. RESULTS: Angiography (type A = 5, B = 7, C = 4) and IVUS proven (partial = 12, complete = 4) dissections were seen in 16 patients following intervention. At six month follow up, six and eight unhealed dissections were seen by angiography (A = 2, B = 4) and IVUS (partial = 7, complete = 1), respectively. The mean IVUS dissection score was 5.2 (range 3-8) following the procedure, and 4.6 (range 3-7) at follow up. No correlation was found between the dose prescribed in the treated area and the presence of unhealed dissection. No change in anginal status was seen despite the presence of unhealed dissection. CONCLUSION: beta radiation appears to alter the normal healing process, resulting in unhealed dissection in certain individuals. In view of the delayed and abnormal healing observed, long term follow up is indicated given the possible late adverse effects of radiation. Although in this cohort no increase in cardiac events following coronary dissections was seen, larger populations are needed to confirm this phenomenon. Stenting of all coronary dissections may be warranted in patients scheduled for brachytherapy after balloon angioplasty.


Assuntos
Angina Pectoris/radioterapia , Angioplastia Coronária com Balão/efeitos adversos , Aneurisma Coronário/fisiopatologia , Vasos Coronários/efeitos da radiação , Cicatrização/efeitos da radiação , Angina Pectoris/terapia , Partículas beta/efeitos adversos , Partículas beta/uso terapêutico , Estudos de Coortes , Aneurisma Coronário/etiologia , Angiografia Coronária , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Cicatrização/fisiologia
20.
J Invasive Cardiol ; 12(2): 113-20, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10731276

RESUMO

Intracoronary radiation is a promising therapy to decrease restenosis after percutaneous intervention. The aim of this pilot study was to determine the mechanism of intracoronary beta-radiation after balloon angioplasty and stenting in a double-blind placebo-controlled randomized fashion. Twenty-six patients were randomized to either placebo (n = 6) or 3 doses (28, 35 and 42 Gy) of beta-radiation (n = 20) using the Guidant brachytherapy system (27 mm long 32P source wire). Of these, 21 patients underwent post-procedure and 6-month follow-up three-dimensional intravascular ultrasound (IVUS) assessment. Volumetric quantification was performed by means of a semi-automated contour detection system after an ECG-gated motorized pullback IVUS imaging and three-dimensional reconstruction. We compared the volumetric changes (Delta) of total vessel volume (TVV), plaque volume (PV) and lumen volume (LV) after 6 months between placebo (dummy wire) and irradiated patients. In addition, the volume of neointimal hyperplasia was quantified within the stented segments. There was an opposite behavior of TVV and LV change between placebo (DeltaTVV = -24 mm3 and DeltaLV = -42 mm3) and irradiated (DeltaTVV = +18 mm3 and (DeltaLV = +5 mm3) patients. The mean neointimal formation within the stented segment in the irradiated patients (n = 7) was 1.9 mm3 (1.5%). Our results suggest that beta-radiation affects vessel remodeling after percutaneous intervention and inhibit neointimal formation in stented patients.


Assuntos
Angioplastia Coronária com Balão , Vasos Coronários/efeitos da radiação , Radioisótopos de Fósforo/uso terapêutico , Stents , Túnica Íntima/efeitos da radiação , Idoso , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Método Duplo-Cego , Feminino , Humanos , Hiperplasia/diagnóstico por imagem , Hiperplasia/radioterapia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Radiografia , Túnica Íntima/diagnóstico por imagem , Ultrassonografia de Intervenção