Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Artif Organs ; 46(7): 1318-1327, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35192209

RESUMO

BACKGROUND: Toxin removal capacity (i.e., performance) of a dialyzer is not constant but diminishes during treatment, as the adsorption of proteins to the membrane provides an additional barrier to uremic solutes. We investigated time-resolving molecular weight retention changes among synthetic high-flux dialyzers and compared the results with recent data from a randomized controlled trial. METHODS: In plasma recirculation experiments over 240 min, sieving coefficients (SC) for ß2-microglobulin, myoglobin, and albumin were determined for the FX CorAL (Fresenius Medical Care), ELISIO (Nipro), and xevonta (B. Braun). Molecular weight retention (MWR) curves were generated and the shifts over 120 min were characterized. Effective pore radius was determined, and the predicted albumin loss was compared with clinical data. RESULTS: SC decreased over time for all dialyzers (mean relative decrease across all dialyzers: ß2-microglobulin: 8.0% (120 min); myoglobin: 56.6% (240 min); albumin: 94.1% (240 min)). FX CorAL (7.3%, 52.6% and 91.1%) and ELISIO (7.7%, 51.0%, and 93.8%) showed a lower decrease than xevonta (9.0%, 66.2%, and 97.4%). For all dialyzers, MWR curves shifted toward lower molecular weight, with the lowest shift for FX CorAL (by 0.23 nm at SC50%, 120 min) and highest for xevonta (0.50 nm). FX CorAL had the highest slope over time and the smallest decrease in the effective pore radius (2 min: 2.31 nm, 120 min: 2.08 nm). Predicted albumin loss over 4 h was highest for xevonta (609.3 mg) and comparable between ELISIO (283.6 mg) and FX CorAL (313.3 mg). CONCLUSIONS: Substantial differences in the temporal performance profile of dialyzers exist. The present approach allows the characterization of dialyzer permeability changes over time using standard, clinically relevant protein markers.


Assuntos
Diálise Renal , Microglobulina beta-2 , Albuminas , Membranas Artificiais , Peso Molecular , Mioglobina , Diálise Renal/métodos
2.
Contrib Nephrol ; 175: 15-26, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22188684

RESUMO

The polysulfone membrane was developed as a membrane for convective dialysis therapies at the beginning of the 1980s. The target was to produce a higher-permeable membrane on the basis of synthetic polymers, such as polysulfone. The development of a membrane with high permeability went hand in hand with a technology development that finally presented as an essential precondition for the success of the polysulfone membrane. This article describes the development phase of the polysulfone membrane using to-date unpublished extracts of the project report of the polysulfone membrane and commenting these from today's perspective.


Assuntos
Hemodiafiltração/história , Hemodiafiltração/instrumentação , Membranas Artificiais , Polímeros , Insuficiência Renal/terapia , Sulfonas , Desenho de Equipamento , Hemodiafiltração/métodos , História do Século XX , História do Século XXI , Humanos , Permeabilidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa