RESUMO
BACKGROUND & AIMS: Significant variability exists in colonoscopy quality indicators, including adenoma detection rate (ADR). We synthesized evidence from randomized trials in a network meta-analysis on interventions to improve colonoscopy quality. METHODS: We included trials from database inceptions to September 25, 2023, of patients undergoing screening-related colonoscopy and presented efficacies of interventions within domains (periprocedural parameters, endoscopist-directed interventions, intraprocedural techniques, endoscopic technologies, distal attachment devices, and additive substances) compared to standard colonoscopy. The primary outcome was ADR. We used a Bayesian random-effects model using Markov-chain Monte Carlo simulation, with 10,000 burn-ins and 100,000 iterations. We calculated odds ratios with 95% credible intervals and present surface under the cumulative ranking (SUCRA) curves. RESULTS: We included 124 trials evaluating 37 interventions for the primary outcome. Nine interventions resulted in statistically significant improvements in ADR compared to standard colonoscopy (9-minute withdrawal time, dual observation, water exchange, i-SCAN [Pentax Ltd], linked color imaging, computer-aided detection, Endocuff [Olympus Corp], Endocuff Vision [Olympus Corp], and oral methylene blue). Dual observation (SUCRA, 0.84) and water exchange (SUCRA, 0.78) ranked highest among intraprocedural techniques; i-SCAN (SUCRA, 0.95), linked color imaging (SUCRA, 0.85), and computer-aided detection (SUCRA, 0.78) among endoscopic technologies; WingCap (A&A Medical Supply LLC) (SUCRA, 0.87) and Endocuff (SUCRA, 0.85) among distal attachment devices and oral methylene blue (SUCRA, 0.94) among additive substances. No interventions improved detection of advanced adenomas, and only narrow-band imaging improved detection of serrated lesions (odds ratio, 2.94; 95% credible interval, 1.46-6.25). CONCLUSIONS: Several interventions are effective in improving adenoma detection and overall colonoscopy quality, many of which are cost-free. These results can inform endoscopists, unit managers, and endoscopy societies on relative efficacies.
Assuntos
Adenoma , Colonoscopia , Detecção Precoce de Câncer , Metanálise em Rede , Ensaios Clínicos Controlados Aleatórios como Assunto , Colonoscopia/normas , Humanos , Adenoma/diagnóstico por imagem , Adenoma/diagnóstico , Detecção Precoce de Câncer/métodos , Detecção Precoce de Câncer/normas , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/diagnóstico por imagem , Melhoria de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Teorema de BayesRESUMO
BACKGROUND: Computer-aided diagnosis (CADx) allows prediction of polyp histology during colonoscopy, which may reduce unnecessary removal of nonneoplastic polyps. However, the potential benefits and harms of CADx are still unclear. PURPOSE: To quantify the benefit and harm of using CADx in colonoscopy for the optical diagnosis of small (≤5-mm) rectosigmoid polyps. DATA SOURCES: Medline, Embase, and Scopus were searched for articles published before 22 December 2023. STUDY SELECTION: Histologically verified diagnostic accuracy studies that evaluated the real-time performance of physicians in predicting neoplastic change of small rectosigmoid polyps without or with CADx assistance during colonoscopy. DATA EXTRACTION: The clinical benefit and harm were estimated on the basis of accuracy values of the endoscopist before and after CADx assistance. The certainty of evidence was assessed using the GRADE (Grading of Recommendations Assessment, Development and Evaluation) framework. The outcome measure for benefit was the proportion of polyps predicted to be nonneoplastic that would avoid removal with the use of CADx. The outcome measure for harm was the proportion of neoplastic polyps that would be not resected and left in situ due to an incorrect diagnosis with the use of CADx. Histology served as the reference standard for both outcomes. DATA SYNTHESIS: Ten studies, including 3620 patients with 4103 small rectosigmoid polyps, were analyzed. The studies that assessed the performance of CADx alone (9 studies; 3237 polyps) showed a sensitivity of 87.3% (95% CI, 79.2% to 92.5%) and specificity of 88.9% (CI, 81.7% to 93.5%) in predicting neoplastic change. In the studies that compared histology prediction performance before versus after CADx assistance (4 studies; 2503 polyps), there was no difference in the proportion of polyps predicted to be nonneoplastic that would avoid removal (55.4% vs. 58.4%; risk ratio [RR], 1.06 [CI, 0.96 to 1.17]; moderate-certainty evidence) or in the proportion of neoplastic polyps that would be erroneously left in situ (8.2% vs. 7.5%; RR, 0.95 [CI, 0.69 to 1.33]; moderate-certainty evidence). LIMITATION: The application of optical diagnosis was only simulated, potentially altering the decision-making process of the operator. CONCLUSION: Computer-aided diagnosis provided no incremental benefit or harm in the management of small rectosigmoid polyps during colonoscopy. PRIMARY FUNDING SOURCE: European Commission. (PROSPERO: CRD42023402197).
Assuntos
Pólipos do Colo , Colonoscopia , Diagnóstico por Computador , Humanos , Pólipos do Colo/patologia , Pólipos do Colo/diagnóstico por imagem , Neoplasias Colorretais/patologia , Neoplasias Colorretais/diagnósticoRESUMO
BACKGROUND & AIMS: Computer-aided diagnosis (CADx) assists endoscopists in differentiating between neoplastic and non-neoplastic polyps during colonoscopy. This study aimed to evaluate the impact of polyp location (proximal vs. distal colon) on the diagnostic performance of CADx for ≤5 mm polyps. METHODS: We searched for studies evaluating the performance of real-time CADx alone (ie, independently of endoscopist judgement) for predicting the histology of colorectal polyps ≤5 mm. The primary endpoints were CADx sensitivity and specificity in the proximal and distal colon. Secondary outcomes were the negative predictive value (NPV), positive predictive value (PPV), and the accuracy of the CADx alone. Distal colon was limited to the rectum and sigmoid. RESULTS: We included 11 studies for analysis with a total of 7782 polyps ≤5 mm. CADx specificity was significantly lower in the proximal colon compared with the distal colon (62% vs 85%; risk ratio (RR), 0.74; 95% confidence interval [CI], 0.72-0.84). Conversely, sensitivity was similar (89% vs 87%); RR, 1.00; 95% CI, 0.97-1.03). The NPV (64% vs 93%; RR, 0.71; 95% CI, 0.64-0.79) and accuracy (81% vs 86%; RR, 0.95; 95% CI, 0.91-0.99) were significantly lower in the proximal than distal colon, whereas PPV was higher in the proximal colon (87% vs 76%; RR, 1.11; 95% CI, 1.06-1.17). CONCLUSION: The diagnostic performance of CADx for polyps in the proximal colon is inadequate, exhibiting significantly lower specificity compared with its performance for distal polyps. Although current CADx systems are suitable for use in the distal colon, they should not be employed for proximal polyps until more performant systems are developed specifically for these lesions.
RESUMO
BACKGROUND AND AIMS: Endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD) are both accepted resection strategies for Barrett's esophagus-related neoplasia and esophageal adenocarcinoma (EAC). However, a lack of consensus exists regarding which technique offers superior outcomes. This study aims to systematically review the evidence comparing EMR versus ESD in treating Barrett's neoplasia and EAC. METHODS: We searched 3 databases (Embase, MEDLINE, Cochrane Central) through October 2023. We included studies comparing the efficacy of EMR and ESD for Barrett's neoplasia and EAC. Primary outcomes include en bloc, R0, and curative resection; complete remission of dysplasia (CRD), and local recurrence. Secondary outcomes encompass adverse events. RESULTS: Our search identified 905 records. Eleven studies were included in the final analyses. Data showed significantly higher en bloc resection rates with ESD (odds ratio [OR], 31.53; 95% confidence interval [CI], 10.02-99.19; P < .01; 7 studies). R0 resection rates were significantly higher with ESD (OR, 5.92; 95% CI, 2.75-12.77; P < .01; 8 studies). Curative resection rates tended to be higher with ESD (OR, 3.49; 95% CI, 0.86-14.14; P = .080; 4 studies). There was no significant difference in CRD rates (OR, 0.92; 95% CI, 0.37-2.26; P = .86; 3 studies). Local recurrence rates tended to be lower with ESD (OR, 0.35; 95% CI, 0.11-1.04; P = .058; 10 studies). As for adverse events, there was no significant difference in bleeding, perforation, and postoperative stricture rates. CONCLUSIONS: This systematic review and meta-analysis demonstrates that ESD achieves higher en bloc, R0, and curative resection rates, with a tendency toward lower recurrence rates. These results suggest that ESD may be a more effective option for managing Barrett's neoplasia and EAC. (International Prospective Register of Systematic Reviews [PROSPERO] registration number: CRD42023426486.).
RESUMO
BACKGROUND AND AIMS: Resection of colorectal polyps has been shown to decrease the incidence and mortality of colorectal cancer. Large nonpedunculated colorectal polyps are often referred to expert centers for endoscopic resection, which requires relevant information to be conveyed to the therapeutic endoscopist to allow for triage and planning of resection technique. The primary objective of this study was to establish minimum expected standards for the referral of large nonpedunculated colonic polyps for potential endoscopic resection. METHODS: A Delphi method was used to establish consensus on minimum expected standards for the referral of large colorectal polyps among a panel of international endoscopy experts. The expert panel was recruited through purposive sampling, and 3 rounds of surveys were conducted to achieve consensus. Quantitative and qualitative data were analyzed for each round. RESULTS: A total of 24 international experts from diverse continents participated in the Delphi study, resulting in consensus on 19 statements related to the referral of large colorectal polyps. The identified factors, including patient demographic characteristics, relevant medications, lesion factors, photodocumentation, and the presence of a tattoo, were deemed important for conveying the necessary information to therapeutic endoscopists. The mean scores for the statements, which were scored on a scale of 1 to 10, ranged from 7.04 to 9.29, with high percentages of experts considering most statements as a very high priority. Subgroup analysis according to continent revealed some variations in consensus rates among experts from different regions. CONCLUSIONS: The identified consensus statements can aid in improving the triage and planning of resection techniques for large colorectal polyps, ultimately contributing to the reduction of colorectal cancer incidence and mortality.
Assuntos
Pólipos do Colo , Colonoscopia , Consenso , Técnica Delphi , Encaminhamento e Consulta , Humanos , Pólipos do Colo/cirurgia , Pólipos do Colo/patologia , Encaminhamento e Consulta/normas , Colonoscopia/normas , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/patologiaRESUMO
BACKGROUND: Endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD) are effective treatments for Barrett's neoplasia. However, little is known about recurrence rates following these techniques. We compared long-term neoplasia recurrence rates following EMR and ESD. METHODS: This study included patients with Barrett's neoplasia (high grade dysplasia/adenocarcinoma) treated between July 2019 and December 2023 at a tertiary referral center in Canada. Outcomes were residual neoplasia at first follow-up, complete remission of neoplasia (CRN), and neoplasia recurrence following CRN. RESULTS: 157 patients were included (87 EMR, 70 ESD). Compared with EMR, the ESD group had larger lesions (median 2 vs. 3 cm, P<0.05), more adenocarcinoma (85.1% vs. 94.3%, P = 0.07), and deeper submucosal invasion (T1a: 71.6% vs. 75.8%; T1b-SM1: 25.7% vs. 6.1%; T1b≥SM2: 2.7% vs. 18.2%; P<0.05). Among 124 patients with follow-up (71 EMR, 53 ESD), 84.9% of ESD-treated patients had curative resections (i.e. R0 resection with low risk for lymph node metastasis), whereas 94.4% of EMR-treated patients had deep margin R0 resection of low risk lesions. At first follow-up, residual neoplasia (14.1% vs. 11.3%) and CRN (97.2% vs. 100%) were similar in the EMR and ESD groups, but neoplasia recurrence following CRN was significantly higher with EMR (13% vs. 1.9%, P<0.05), with cumulative probability of recurrence at 3 years of 18.3% vs. 4.2%, respectively. CONCLUSIONS: Neoplasia recurrence following CRN was significantly higher following EMR compared with ESD, suggesting that ESD may be superior to EMR in preventing neoplasia recurrence in Barrett's esophagus.
RESUMO
INTRODUCTION: Chronic calcific pancreatitis (CCP) is a debilitating inflammatory condition characterized by the accumulation of calcific deposits in the pancreatic tissue, leading to chronic abdominal pain and functional insufficiencies. This study aims to systematically review and meta-analyse comparative studies assessing the efficacy of endotherapy versus surgery in managing CCP-related pain. METHODS: MEDLINE, EMBASE, and Cochrane library (CENTRAL and CDSR), from inception to October 2023, were searched. The inclusion criteria encompassed randomized controlled trials (RCTs) and non-randomized controlled trials (NRS), and cohort studies comparing endoscopic interventions to surgery for pain management in patients with CCP. Pain relief, procedural technical success, and procedural-related complications were the outcomes of interest. Two review authors (CN, KK) independently assessed study eligibility criteria and performed data extraction. Using a random-effects model, pooled odds ratios (OR) with 95% confidence intervals (CI) were calculated. The level of certainty of the evidence was assessed using the GRADE approach. RESULTS: Five studies were included. For the outcome of pain relief, a meta-analysis of five studies (3 RCTs and 2 cohort studies) demonstrated a significant therapeutic effect in favour of surgery with an OR of 2.36 (95% CI: 1.12 to 5.00, I2 = 41.70), with moderate level of certainty of evidence. In the analysis of five studies (3 RCTs, 1 NRS and 2 cohort studies), procedural technical success was comparable between the two groups (OR of 3.02, 95% CI: 0.47 to 19.59, I2 = 79.27%) as were adverse events (OR 1.31, 95% CI: 0.47 to 3.70, I2 = 50.93%). CONCLUSION: In conclusion, this systematic review and meta-analysis suggest that surgery may be more effective in relieving pain in patients with CCP compared to endoscopic interventions. Disease stage may be important to determine the appropriateness of each procedure. PROSPERO (CRD42023476153).
RESUMO
BACKGROUND: Artificial intelligence computer-aided detection (CADe) of colorectal neoplasia during colonoscopy may increase adenoma detection rates (ADRs) and reduce adenoma miss rates, but it may increase overdiagnosis and overtreatment of nonneoplastic polyps. PURPOSE: To quantify the benefits and harms of CADe in randomized trials. DESIGN: Systematic review and meta-analysis. (PROSPERO: CRD42022293181). DATA SOURCES: Medline, Embase, and Scopus databases through February 2023. STUDY SELECTION: Randomized trials comparing CADe-assisted with standard colonoscopy for polyp and cancer detection. DATA EXTRACTION: Adenoma detection rate (proportion of patients with ≥1 adenoma), number of adenomas detected per colonoscopy, advanced adenoma (≥10 mm with high-grade dysplasia and villous histology), number of serrated lesions per colonoscopy, and adenoma miss rate were extracted as benefit outcomes. Number of polypectomies for nonneoplastic lesions and withdrawal time were extracted as harm outcomes. For each outcome, studies were pooled using a random-effects model. Certainty of evidence was assessed using the GRADE (Grading of Recommendations Assessment, Development and Evaluation) framework. DATA SYNTHESIS: Twenty-one randomized trials on 18 232 patients were included. The ADR was higher in the CADe group than in the standard colonoscopy group (44.0% vs. 35.9%; relative risk, 1.24 [95% CI, 1.16 to 1.33]; low-certainty evidence), corresponding to a 55% (risk ratio, 0.45 [CI, 0.35 to 0.58]) relative reduction in miss rate (moderate-certainty evidence). More nonneoplastic polyps were removed in the CADe than the standard group (0.52 vs. 0.34 per colonoscopy; mean difference [MD], 0.18 polypectomy [CI, 0.11 to 0.26 polypectomy]; low-certainty evidence). Mean inspection time increased only marginally with CADe (MD, 0.47 minute [CI, 0.23 to 0.72 minute]; moderate-certainty evidence). LIMITATIONS: This review focused on surrogates of patient-important outcomes. Most patients, however, may consider cancer incidence and cancer-related mortality important outcomes. The effect of CADe on such patient-important outcomes remains unclear. CONCLUSION: The use of CADe for polyp detection during colonoscopy results in increased detection of adenomas but not advanced adenomas and in higher rates of unnecessary removal of nonneoplastic polyps. PRIMARY FUNDING SOURCE: European Commission Horizon 2020 Marie Sklodowska-Curie Individual Fellowship.
Assuntos
Inteligência Artificial , Neoplasias Colorretais , Humanos , Neoplasias Colorretais/diagnóstico , Computadores , Colonoscopia , Bases de Dados FactuaisRESUMO
BACKGROUND: Duodenoscope-related multidrug-resistant organism (MDRO) infections raise concerns. Disposable duodenoscopes have been recently introduced in the market and approved by regulatory agencies with the aim to reduce the risk of endoscopic retrograde cholangiopancreatography (ERCP) associated infections. The aim of this study was to evaluate the outcome of procedures performed with single-use duodenoscopes in patients with clinical indications to single-operator cholangiopancreatoscopy. METHODS: This is a multicenter international, retrospective study combining all patients who underwent complex biliopancreatic interventions using the combination of a single-use duodenoscope and a single-use cholangioscope. The primary outcome was technical success defined as ERCP completion for the intended clinical indication. Secondary outcomes were procedural duration, rate of cross-over to reusable duodenoscope, operator-reported satisfaction score (1 to 10) on performance rating of the single-use duodenoscope, and adverse event (AE) rate. RESULTS: A total of 66 patients (26, 39.4% female) were included in the study. ERCP was categorized according to ASGE ERCP grading system as 47 (71.2%) grade 3 and 19 (28.8%) grade 4. The technical success rate was 98.5% (65/66). Procedural duration was 64 (interquartile range 15-189) min, cross-over rate to reusable duodenoscope was 1/66 (1.5%). The satisfaction score of the single-use duodenoscope classified by the operators was 8.6 ± 1.3 points. Four patients (6.1%) experienced AEs not directly related to the single-use duodenoscope, namely 2 post-ERCP pancreatitis (PEP), 1 cholangitis and 1 bleeding. CONCLUSIONS: Single-use duodenoscope is effective, reliable and safe even in technically challenging procedures with a non-inferiority to reusable duodenoscope, making these devices a viable alternative to standard reusable equipment.
Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Pancreatite , Humanos , Feminino , Masculino , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Estudos Retrospectivos , Cateterismo , Duodenoscópios/efeitos adversos , Pancreatite/etiologia , Pancreatite/prevenção & controleRESUMO
This review article provides a comprehensive overview of the evolving techniques in image-enhanced endoscopy (IEE) for the characterization of colorectal polyps, and the potential of artificial intelligence (AI) in revolutionizing the diagnostic accuracy of endoscopy. We discuss the historical use of dye-spray and virtual chromoendoscopy for the characterization of colorectal polyps, which are now being replaced with more advanced technologies. Specifically, we focus on the application of AI to create a "virtual biopsy" for the detection and characterization of colorectal polyps, with potential for replacing histopathological diagnosis. The incorporation of AI has the potential to provide an evolutionary learning system that aids in the diagnosis and management of patients with the best possible outcomes. A detailed analysis of the literature supporting AI-assisted diagnostic techniques for the detection and characterization of colorectal polyps, with a particular emphasis on AI's characterization mechanism, is provided. The benefits of AI over traditional IEE techniques, including the reduction in human error in diagnosis, and its potential to provide an accurate diagnosis with similar accuracy to the gold standard are presented. However, the need for large-scale testing of AI in clinical practice and the importance of integrating patient data into the diagnostic process are acknowledged. In conclusion, the constant evolution of IEE technology and the potential for AI to revolutionize the field of endoscopy in the future are presented.
Assuntos
Inteligência Artificial , Pólipos do Colo , Humanos , Pólipos do Colo/diagnóstico por imagem , Coloração e Rotulagem , Biópsia , AprendizagemRESUMO
Gastrojejunostomy is the principal method of palliation for unresectable malignant gastric outlet obstructions (GOO). Gastrojejunostomy was traditionally performed as a surgical procedure with an open approach butrecently, notable progress in the development of minimally invasive procedures such as laparoscopic gastrojejunostomies have emerged. Additionally, advancements in endoscopic techniques, including endoscopic stenting (ES) and endoscopic ultrasound-guided gastroenterostomy (EUS-GE), are becoming more prominent. ES involves the placement of self-expandable metal stents (SEMS) to restore luminal patency. ES is commonly the first choice for patients deemed unfit for surgery or at high surgical risk. However, although ES leads to rapid improvement of symptoms, it carries limitations like higher stent dysfunction rates and the need for frequent re-interventions. Recently, EUS-GE has emerged as a potential alternative, combining the minimally invasive nature of the endoscopic approach with the long-lasting effects of a gastrojejunostomy. Having reviewed the advantages and disadvantages of these different techniques, this article aims to provide a comprehensive review regarding the management of unresectable malignant GOO.
Assuntos
Obstrução da Saída Gástrica , Obstrução da Saída Gástrica/cirurgia , Obstrução da Saída Gástrica/etiologia , Humanos , Cuidados Paliativos/métodos , Derivação Gástrica/métodos , Stents , Endossonografia/métodos , Neoplasias Gástricas/complicações , Neoplasias Gástricas/cirurgiaRESUMO
BACKGROUND: Endoluminal Functional Lumen Imaging Probe (EndoFLIP) is a device that measures gastro-esophageal junction (GEJ) distensibility. However, it is not demonstrated that GEJ distensibility increases proportionally with varying gastric myotomy length in peroral endoscopic myotomy (POEM). This study aimed to investigate the association between gastric myotomy length in POEM and intraoperative EndoFLIP findings. METHODS: This single-center, retrospective cohort study included patients who underwent POEM with intraoperative EndoFLIP from December 2019 to January 2023. Using EndoFLIP, minimal balloon diameter and its distensibility index (DI) were measured pre- and post-myotomy. Primary and secondary outcomes were the post-myotomy EndoFLIP findings at 30 ml and 40 ml volume fills. RESULTS: The study included 44 patients (mean age 53.1 years, 50% female). Chicago classification included achalasia type I (39%), II (41%), III (9%), hypercontractile esophagus (2%), and EGJOO (9%). The mean esophageal myotomy length was 7.5 ± 2.2 cm and gastric myotomy was 2.1 ± 0.6 cm. Simple linear regression analyses indicated that for each 1 cm increase in gastric myotomy length, the DI at 30 ml volume fill was estimated to increase by 2.0 mm2/mmHg (p < 0.05, R2 = 0.41), the minimal diameter at 30 ml volume fill was estimated to increase by 2.4 mm (p < 0.05, R2 = 0.48), and the minimal diameter at 40 ml volume fill was estimated to increase by 1.3 mm (p < 0.05, R2 = 0.09). CONCLUSIONS: This study demonstrates a significant linear relationship between gastric myotomy length and GEJ distensibility measured by EndoFLIP during POEM. These findings may be useful in clinical practice by enabling EndoFLIP to help calibrate a desired gastric myotomy length to achieve optimal DI and minimal diameter.
Assuntos
Acalasia Esofágica , Junção Esofagogástrica , Miotomia , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Junção Esofagogástrica/cirurgia , Junção Esofagogástrica/fisiopatologia , Acalasia Esofágica/cirurgia , Acalasia Esofágica/fisiopatologia , Miotomia/métodos , Adulto , Idoso , Manometria/métodos , Resultado do TratamentoRESUMO
BACKGROUND AND AIMS: Benefits of computer-aided detection (CADe) in detecting colorectal neoplasia were shown in many randomized trials in which endoscopists' behavior was strictly controlled. However, the effect of CADe on endoscopists' performance in less-controlled setting is unclear. This systematic review and meta-analyses were aimed at clarifying benefits and harms of using CADe in real-world colonoscopy. METHODS: We searched MEDLINE, EMBASE, Cochrane, and Google Scholar from inception to August 20, 2023. We included nonrandomized studies that compared the effectiveness between CADe-assisted and standard colonoscopy. Two investigators independently extracted study data and quality. Pairwise meta-analysis was performed utilizing risk ratio for dichotomous variables and mean difference (MD) for continuous variables with a 95% confidence interval (CI). RESULTS: Eight studies were included, comprising 9782 patients (4569 with CADe and 5213 without CADe). Regarding benefits, there was a difference in neither adenoma detection rate (44% vs 38%; risk ratio, 1.11; 95% CI, 0.97 to 1.28) nor mean adenomas per colonoscopy (0.93 vs 0.79; MD, 0.14; 95% CI, -0.04 to 0.32) between CADe-assisted and standard colonoscopy, respectively. Regarding harms, there was no difference in the mean non-neoplastic lesions per colonoscopy (8 studies included for analysis; 0.52 vs 0.47; MD, 0.14; 95% CI, -0.07 to 0.34) and withdrawal time (6 studies included for analysis; 14.3 vs 13.4 minutes; MD, 0.8 minutes; 95% CI, -0.18 to 1.90). There was a substantial heterogeneity, and all outcomes were graded with a very low certainty of evidence. CONCLUSION: CADe in colonoscopies neither improves the detection of colorectal neoplasia nor increases burden of colonoscopy in real-world, nonrandomized studies, questioning the generalizability of the results of randomized trials.
RESUMO
BACKGROUND AND AIMS: Adenoma detection rate (ADR) is still the main surrogate outcome parameter of screening colonoscopy, but most studies include mixed indications, and basic ADR is quite variable. We therefore looked at the control groups in randomized ADR trials using advanced imaging or mechanical methods to find out whether indications or other factors influence ADR levels. METHODS: Patients in the control groups of randomized controlled trials (RCTs) on ADR increase using various methods were collected based on a systematic review; this control group had to use high-definition white-light endoscopy performed between 2008 and 2021. Random-effects meta-analysis was used to pool ADR in control groups and its 95% confidence interval (CI) according to clinical (indication and demographic), study setting (tandem/parallel, number of centers, sample size), and technical (type of intervention, withdrawal time) parameters. Interstudy heterogeneity was reported with the I2 statistic. Multivariable mixed-effects meta-regression was performed for potentially relevant variables. RESULTS: From 80 studies, 25,304 patients in the respective control groups were included. ADR in control arms varied between 8.2% and 68.1% with a high degree of heterogeneity (I2 = 95.1%; random-effect pooled value, 37.5%; 95% CI, 34.6â40.5). There was no difference in ADR levels between primary colonoscopy screening (12 RCTs, 15%) and mixed indications including screening/surveillance and diagnostic colonoscopy; however, fecal immunochemical testing as an indication for colonoscopy was an independent predictor of ADR (odds ratio [OR], 1.6; 95% CI, 1.1-2.4). Other well-known parameters were confirmed by our analysis such as age (OR, 1.038; 95% CI, 1.004-1.074), sex (male sex: OR, 1.02; 95% CI, 1.01-1.03), and withdrawal time (OR, 1.1; 95% CI, 1.0-1.1). The type of intervention (imaging vs mechanical) had no influence, but methodologic factors did: More recent year of publication and smaller sample size were associated with higher ADR. CONCLUSIONS: A high level of variability was found in the level of ADR in the control groups of RCTs. With regards to indications, only fecal immunochemical test-based colonoscopy studies influenced basic ADR, and primary colonoscopy screening appeared to be similar to other indications. Standardization for variables related to clinical, methodologic, and technical parameters is required to achieve generalizability and reproducibility.
Assuntos
Adenoma , Neoplasias Colorretais , Masculino , Humanos , Grupos Controle , Colonoscopia/métodos , Adenoma/diagnóstico por imagem , Programas de Rastreamento , Razão de Chances , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodosRESUMO
BACKGROUND AND AIMS: The role of the newer EUS fine-needle biopsy needles in lymphadenopathies (LAs) is still under evaluation. We aimed to evaluate the diagnostic accuracy and adverse event rate of EUS-guided fine-needle biopsy sampling (EUS-FNB) in diagnosing LAs. METHODS: From June 2015 to June 2022, all patients referred to 4 institutions for EUS-FNB of mediastinal and abdominal LAs were enrolled. Twenty-two-gauge Franseen tip or 25-gauge fork-tip needles were used. The criterion standard for positive results was surgery or imaging and clinical evolution over a follow-up of at least 1 year. RESULTS: One hundred consecutive patients were enrolled, consisting of those with a new diagnosis of LA (40%), presence of LA with a previous history of neoplasia (51%), or suspected lymphoproliferative disease (9%). EUS-FNB was technically feasible in all LA patients with 2 to 3 passes (mean, 2.62 ± .93). The overall sensitivity, positive predictive value, specificity, negative predictive value, and accuracy for EUS-FNB were 96.20%, 100%, 100%, 87.50%, and 97.00%, respectively. Histologic analysis was feasible in 89% of cases. Cytologic evaluation was performed in 67% of specimens. A statistical difference between the accuracy of the 22-gauge or 25-gauge needle (P = .63) was not found. A subanalysis on lymphoproliferative disease revealed a sensitivity and accuracy of 89.29% and 90.0%, respectively. No adverse events were recorded. CONCLUSIONS: EUS-FNB with new end-cutting needles is a valuable and safe method to diagnose LAs. The high quality of histologic cores and the good amount of tissue allowed a complete immunohistochemical analysis of metastatic LAs and precise subtyping of the lymphomas. (Clinical trial registration number: NCT02855151.).
Assuntos
Linfadenopatia , Linfoma , Neoplasias , Neoplasias Pancreáticas , Humanos , Estudos Prospectivos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/efeitos adversos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Linfadenopatia/diagnóstico , Linfoma/diagnóstico , Linfoma/patologia , Neoplasias Pancreáticas/patologiaRESUMO
Asthma is characterized by multiple immunological mechanisms (endotypes) determining variable clinical presentations (phenotypes). The identification of endotypic mechanisms is crucial to better characterize patients and to identify tailored therapeutic approaches with novel biological agents targeting specific immunological pathways. This review focused on summarizing the major immunological mechanisms involved in the pathogenesis of asthma, as well as on discussing the emergence of phenotypic features of the disease. Novel biological agents and other drugs targeting specific endotypes are discussed, as their use represent a precision medicine approach to the disease that is nowadays mandatory particularly for treating more severe patients.
Assuntos
Antiasmáticos/uso terapêutico , Asma/imunologia , Produtos Biológicos/uso terapêutico , Animais , Asma/terapia , Humanos , Imunidade Inata , Fenótipo , Medicina de PrecisãoRESUMO
In this Special Issue of Medicina entitled "Recent Advances in Biliopancreatic Endoscopy" in the Section "Gastroenterology & Hepatology", nine articles pave new insights into the advances in the world of biliopancreatic endoscopy [...].
Assuntos
Endoscopia , Gastroenterologia , Trato Gastrointestinal , HumanosRESUMO
Walled-off pancreatic necrosis (WOPN) is one of the local complications of acute pancreatitis (AP). Several interventional techniques have been developed over the last few years. The purpose of this narrative review is to explore such methodologies, with specific focus on endoscopic drainage and direct endoscopic necrosectomy (DEN), through evaluation of their indications and timing for intervention. Findings indicated how, after the introduction of lumen-apposing metal stents (LAMS), DEN is becoming the favorite technique to treat WOPN, especially when large solid debris or infection are present. Additionally, DEN is associated with a lower adverse events rate and hospital stay, and with improved clinical outcome.
Assuntos
Drenagem , Pancreatite Necrosante Aguda , Doença Aguda , Humanos , Pancreatite Necrosante Aguda/cirurgia , Estudos Retrospectivos , Stents , Resultado do TratamentoRESUMO
OBJECTIVE: To assess the status of vitamin B12 in patients with type 2 diabetes, and to explore any association between its deficiency and diabetic peripheral neuropathy. METHODS: This cross-sectional observational study was conducted from August, 2017, to April, 2018, at the Specialized Centre for Endocrinology and Diabetes in Baghdad, Iraq. Type 2 diabetics using metformin were subjected to clinical examination for retinopathy using fundoscopy, and peripheral neuropathy using the Michigan Neuropathy Screening Instrument. Additionally, patients were asked to fill a questionnaire and their medical records were reviewed. Blood samples were obtained for the measurement of biomarkers. Vitamin B12 deficiency was recorded at ≤187 pg/ml. Data was analysed using SPSS 25. RESULTS: Of the 66 patients, 39(59%) were males and 27(41%) were females. The overall mean age was 53.3}9.2 years and the mean duration of diabetes was 104}71.8 months. The mean dose of metformin was 1135}496 mg and the duration of metformin use was 72}62 months. Overall, 19(29%) patients suffered from vitamin B12 deficiency. However, no significant difference was found between normal and deficit groups regarding the parameters that may affect vitamin B12 level. Also, no significant correlations were found between vitamin B12 concentration and the dose (p=0.16) or the duration of metformin use (p=0.09). CONCLUSIONS: High prevalence of vitamin B12 deficiency was observed in metformin-treated patients with type 2 diabetes. However, the deficiency had no correlation with the rate of peripheral neuropathy.