Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
BMC Musculoskelet Disord ; 24(1): 171, 2023 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-36882825

RESUMO

BACKGROUND: Elliptical shape humeral head prostheses have been recently proposed to reflect a more anatomic shoulder replacement. However, its effect on obligate glenohumeral translation during axial rotation compared to a standard spherical head is still not well understood. The purpose of the study was to compare obligate humeral translation during axial rotation using spherical and elliptical shaped humeral head prostheses. It was hypothesized that the spherical head design would show significantly more obligate translation when compared to the elliptical design. METHODS: Six fresh-frozen cadaveric shoulders were utilized for biomechanical testing of internal (IR) and external (ER) rotation at various levels of abduction (0°, 30°, 45°, 60°) with lines of pull along each of the rotator cuff muscles. Each specimen underwent the following three conditions: (1) native; total shoulder arthroplasty (TSA) using (2) an elliptical and (3) spherical humeral head implant. Obligate translation during IR and ER was quantified using a 3-dimensional digitizer. The radius of curvature of the superoinferior and anteroposterior dimensions of the implants was calculated across each condition. RESULTS: Posterior and inferior translation as well as compound motion of spherical and elliptical heads during ER was similar at all abduction angles (P > 0.05, respectively). Compared to the native humeral head, both implants demonstrated significantly decreased posterior translation at 45° (elliptical: P = 0.003; spherical: P = 0.004) and 60° of abduction (elliptical: P < 0.001; spherical: P < 0.001). During internal rotation at 0° abduction, the spherical head showed significantly more compound motion (P = 0.042) compared to the elliptical head. The spherical implant also demonstrated increased anterior translation and compound motion during internal rotation at 60° abduction (P < 0.001) compared to the resting state. This difference was not significant for the native or elliptical head design at this angle (P > 0.05). CONCLUSION: In the setting of TSA, elliptical and spherical head implants showed similar obligate translation and overall compound motion during axial rotation. A gained understanding of the consequences of implant head shape in TSA may guide future surgical implant choice for better recreation of native shoulder kinematics and potentially improved patient outcomes. LEVEL OF EVIDENCE: Controlled Laboratory Study.


Assuntos
Artroplastia do Ombro , Artroplastia de Substituição , Bursite , Humanos , Rotação , Extremidade Superior , Cabeça do Úmero/cirurgia
2.
Arch Orthop Trauma Surg ; 143(1): 177-187, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34216260

RESUMO

INTRODUCTION: Elliptical-shaped humeral head prostheses have recently been proposed to reflect a more anatomic shoulder replacement. However, its subsequent effect on micro-motion of the glenoid component is still not understood. MATERIALS AND METHODS: Six fresh-frozen, cadaveric shoulders (mean age: 62.7 ± 9.2 years) were used for the study. Each specimen underwent total shoulder arthroplasty using an anatomic stemless implant. At 15°, 30°, 45° and 60° of glenohumeral abduction, 50° of internal and external rotations in the axial plane were alternatingly applied to the humerus with both an elliptical and spherical humeral head design. Glenohumeral translation was assessed by means of a 3-dimensional digitizer. Micro-motion of the glenoid component was evaluated using four high-resolution differential variable reluctance transducer strain gauges, placed at the anterior, posterior, superior, and inferior aspect of the glenoid component. RESULTS: The elliptical head design showed significantly more micro-motion in total and at the superior aspect of glenoid component during external rotation at 15° (total: P = 0.004; superior: P = 0.004) and 30° (total: P = 0.045; superior: P = 0.033) of abduction when compared to the spherical design. However, during internal rotation, elliptical and spherical heads showed similar amounts of micro-motion at the glenoid component at all tested abduction angles. When looking at glenohumeral translation, elliptical and spherical heads showed similar anteroposterior and superoinferior translation as well as compound motion during external rotation at all tested abduction angles. During internal rotation, the elliptical design resulted in significantly more anteroposterior translation and compound motion at all abduction angles when compared to the spherical design (P < 0.05). CONCLUSION: In the setting of total shoulder arthroplasty, the elliptical head design demonstrated greater glenohumeral translation and micro-motion at the glenoid component during axial rotation when compared to the spherical design, potentially increasing the risk for glenoid loosening in the long term. LEVEL OF EVIDENCE: Controlled Laboratory Study.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Pessoa de Meia-Idade , Idoso , Articulação do Ombro/cirurgia , Fenômenos Biomecânicos , Amplitude de Movimento Articular , Cadáver , Cabeça do Úmero/cirurgia
3.
J Shoulder Elbow Surg ; 31(11): 2392-2401, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35671930

RESUMO

BACKGROUND: In the setting of irreparable posterosuperior rotator cuff tears (PSRCTs), lower trapezius transfer (LTT) may be anatomically better positioned for restoring the muscular force couple compared with latissimus dorsi transfer (LDT). The purpose of the study was to evaluate the effect of LTT and LDT on glenohumeral kinematics using a dynamic shoulder model. METHODS: Ten fresh-frozen cadaveric shoulders (mean age: 56.5 ± 17.2 years) were tested using a dynamic shoulder simulator. The maximum abduction angle (MAA), superior humeral head migration (SHM), and cumulative deltoid forces (CDFs) were compared across 4 conditions: (1) native; (2) irreparable PSRCT; (3) LTT using an Achilles tendon allograft; and (4) LDT. MAA and SHM were measured using 3-dimensional motion tracking. CDF was recorded in real time throughout the dynamic abduction motion by load cells connected to actuators. RESULTS: Compared to the native state, the PSRCT resulted in a significant decrease (Δ-24.1°; P < .001) in MAA, with a subsequent significant increase after LTT (Δ13.1°; P < .001) and LDT (Δ8.9°; P < .001). LTT achieved a significantly greater MAA than LDT (Δ4.2°; P = .004). Regarding SHM, both LTT (Δ-9.4 mm; P < .001) and LDT (Δ-5.0 mm; P = .008) demonstrated a significant decrease compared with the PSRCT state. LTT also achieved significantly less SHM compared with the LDT (Δ-4.4 mm; P = .011). Further, only the LTT resulted in a significant decrease in CDF compared with the PSRCT state (Δ-21.3 N; P = .048), whereas LTT and LDT showed similar CDF (Δ-11.3 N; P = .346). However, no technique was able to restore the MAA, SHM, and CDF of the native shoulder (P < .001, respectively). CONCLUSION: LTT and LDT both achieved a significant increase in MAA along with significantly less SHM compared with the PSRCT state. Although LTT required significantly less compensatory deltoid forces compared with the PSRCT state, this was not observed for the LDT. Further, the LTT prevented loss of abduction motion and SHM more sufficiently. In the challenging treatment of irreparable PSRCTs, LTT may restore native glenohumeral kinematics more sufficiently, potentially leading to improved postoperative functional outcomes.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Músculos Superficiais do Dorso , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Lesões do Manguito Rotador/cirurgia , Músculos Superficiais do Dorso/cirurgia , Ombro , Manguito Rotador/cirurgia , Articulação do Ombro/cirurgia , Amplitude de Movimento Articular , Fenômenos Biomecânicos , Transferência Tendinosa/métodos , Resultado do Tratamento
4.
Arch Orthop Trauma Surg ; 142(1): 67-76, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32865631

RESUMO

INTRODUCTION: Elliptical shape humeral head prostheses have been proposed to reflect a more anatomic shoulder replacement. Its effect on the rotational range of motion (ROM) compared to a standard spherical head is still not understood. The purpose was to investigate if there would be a difference in rotational ROM when comparing elliptical and spherical prosthetic heads in a dynamic shoulder model. The authors hypothesized that the use of elliptical heads would result in significantly more rotational ROM compared to the spherical head design. MATERIALS AND METHODS: Six fresh-frozen, cadaveric shoulders were evaluated using a dynamic shoulder model. After being tested in the native condition, each specimen underwent 6 conditions in the hemiarthroplasty state: (1) matched-fit spherical head, (2) oversized spherical head, (3) undersized spherical head, (4) matched-fit elliptical head, (5) oversized elliptical head, and (6) undersized elliptical head. Following conversion to total shoulder arthroplasty (TSA), the 6 prior conditions were rerun. Each condition was tested at 0°, 30° and 60° of glenohumeral abduction. Rotational ROM was quantified using 3-dimensional tracking, while dynamically applying alternating forces for internal and external rotation via the rotator cuff tendons. RESULTS: Elliptical and spherical prosthetic heads showed no significant difference in the degree of the total, internal, and external rotational ROM for both the hemiarthroplasty and TSA state. Conversion from hemiarthroplasty to TSA resulted in less degree of total rotational ROM for both head designs in all abduction positions, without reaching statistical significance. There was a significant decrease in total, internal, and external rotational ROM for both elliptical and spherical heads in every replacement condition, when comparing 0° to 30° and 60° of abduction (P < 0.05, respectively). CONCLUSION: In a dynamic shoulder model, elliptical and spherical prosthetic head designs showed no significant difference in the degree of the total, internal, and external rotational ROM in both the hemiarthroplasty and TSA state. LEVEL OF EVIDENCE: Controlled laboratory study.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Fenômenos Biomecânicos , Cadáver , Humanos , Amplitude de Movimento Articular , Articulação do Ombro/cirurgia
5.
Arch Orthop Trauma Surg ; 142(9): 2271-2277, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34673999

RESUMO

INTRODUCTION: Femoral nerve block (FNB) is a routinely used regional analgesic technique for anterior cruciate ligament (ACL) reconstruction. One method to balance the analgesic effect and functional impairment of FNBs may be to control the concentration of local anesthetics utilized for the block. MATERIALS AND METHODS: Retrospective chart review was performed on 390 consecutive patients who underwent ACL reconstruction between June 2014 and May 2017. Patients were divided into those who received a standard (0.5%-bupivacaine) or low (0.1-0.125%-bupivacaine) concentration single-shot FNB performed with ultrasound guidance. Maximum postoperative VAS, Post-Anaesthesia Care Unit (PACU) time prior to discharge, need for additional 'rescue' block, and intravenous postoperative narcotic requirements were recorded. RESULTS: A total of 268 patients (28.4 ± 11.9 years) were included for final analysis, with 72 patients in the low-concentration FNB group and 196 patients receiving the standard concentration. There were no differences in the maximum postoperative VAS between the low (6.4 ± 2.5) and standard (5.7 ± 2.9) concentration groups (P = 0.08). Similarly, the time from PACU arrival to discharge was not different between groups (P = 0.64). A sciatic rescue block was needed in 22% of patients with standard-dose FNB compared to 30% of patients receiving the low-concentration FNB (P = 0.20). Patients with a hamstring autograft harvest were more likely to undergo a postoperative sciatic rescue block compared to a bone-patellar tendon autograft (P = 0.005), regardless of preoperative block concentration. Quadriceps activation was preserved with low-concentration blocks. CONCLUSIONS: Using 1/5th to 1/4th the standard local anesthetic concentration for preoperative femoral nerve block in ACL reconstruction did not significantly differ in peri-operative outcomes, PACU time, need for rescue blockade, or additional immediate opioid requirements. LEVEL OF EVIDENCE: III.


Assuntos
Nervo Femoral , Bloqueio Nervoso , Analgésicos Opioides , Anestésicos Locais , Bupivacaína , Humanos , Bloqueio Nervoso/métodos , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Estudos Retrospectivos
6.
Arthroscopy ; 37(7): 2043-2052, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33581306

RESUMO

PURPOSE: To evaluate whether nucleated cell count (NCC) could serve as an approximation for the number of colony-forming units (CFUs) in concentrated bone marrow aspirate (cBMA) obtained from the proximal humerus. METHODS: Bone marrow aspirate (BMA) was harvested from the proximal humerus in 96 patients (mean age 56.2 ± 7.0 years) during arthroscopic rotator cuff repair. Following concentration of the aspirate, nucleated cells of each sample were counted. The total number of CFUs was evaluated under the microscope at their first appearance, usually after 5 to 10 days in culture. Fluorescence-activated cell sorting analysis and assays for osteogenic, adipogenic, and chondrogenic differentiation were performed. Linear regression was assessed to predict the number of CFUs by using NCC. Age, sex, and body mass index (BMI) were evaluated as independent variables. RESULTS: The average volume of the obtained BMA was 86.7 ± 35.2 mL. The cBMA contained a mean of 26.3 ± 6.8 × 106 nucleated cells per mL, which yielded a mean of 1421.7 ± 802.7 CFUs in cell culture. There were no significant differences in NCC or number of CFUs when sex, volume of BMA, age, or BMI was examined independently (P >.05, respectively). Linear regression found that NCC was of limited predictive value for the total number of CFUs being yielded after cell culture (r2 = 0.28 with a root mean square error of 679.4). CONCLUSION: NCC was of negligible predictive value for the total number of CFUs for connective tissue progenitor cells in BMA harvested from the proximal humerus during arthroscopic rotator cuff repair. CLINICAL RELEVANCE: NCC is often used to assess the quality of cBMA samples for biological augmentation during surgery. The limited predictive value of this measurement tool is of clinical importance, because effectiveness of BMA applications has been suggested to depend on the concentration of progenitor cells within the sample.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Artroscopia , Medula Óssea , Células da Medula Óssea , Contagem de Células , Tecido Conjuntivo , Humanos , Úmero , Pessoa de Meia-Idade , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Células-Tronco
7.
Knee Surg Sports Traumatol Arthrosc ; 29(7): 2096-2102, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32607814

RESUMO

PURPOSE: To evaluate the clinical and radiographic outcomes of patients undergoing anatomic coracoclavicular ligament reconstruction (ACCR) using free tendon allografts for the treatment of chronic acromioclavicular joint (ACJ) injuries with a minimum 1-year follow-up. METHODS: Patients who underwent ACCR for chronic ACJ injuries between 2003 and 2017 were analyzed. Clinical outcome measures included American Shoulder and Elbow Surgeons (ASES), Constant-Murley (CM), Simple Shoulder Test (SST), and Single Assessment Numerical Evaluation (SANE) scores. Radiographic loss of reduction during follow-up was evaluated by calculating the difference (mm) in the coracoclavicular distance (CCD) of the involved side immediately postoperatively and at terminal follow-up. RESULTS: Forty-two patients (mean age: 42.7 ± 12.8 years) were included in the study with an average follow-up of 3.8 ± 3.1 years (range: 1.1-11.5 years). Patients achieved significant improvement in ASES (50.2 ± 20.1 pre to 85.2 ± 16.3 post), CM (60.2 ± 18.5 pre to 88.2 ± 9.1 post), SST (6.1 ± 3.2 pre to 9.5 ± 3.7 post), and SANE (24.0 ± 25.7 pre to 89.0 ± 12.7 post) scores (P < 0.001, respectively). There were no significant differences in functional improvement when comparing type III and V injuries (n.s.). Mean increase in CCD of the involved side from immediately postoperative to final radiographic follow-up was 4.1 ± 3.9 mm, with no significant correlation to clinical outcomes scores. Complications occurred in 33.3% of cases, with postoperative heterotopic ossification being most frequent (14.3%). CONCLUSION: Patients undergoing ACCR using free tendon allografts for chronic ACJ injuries achieved significant improvement in shoulder function at a mean follow-up of 3.8 years. No correlation was observed between the amount of loss of reduction and clinical outcome scores. Free tendon allografts may be a reliable alternative to autografts in the treatment of chronic ACJ dislocations. LEVEL OF EVIDENCE: IV.


Assuntos
Articulação Acromioclavicular/cirurgia , Luxações Articulares/cirurgia , Ligamentos Articulares/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Tendões/transplante , Articulação Acromioclavicular/lesões , Adulto , Aloenxertos , Autoenxertos , Clavícula/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Radiografia/métodos , Luxação do Ombro/cirurgia , Transplante Autólogo , Transplante Homólogo , Resultado do Tratamento
8.
Knee Surg Sports Traumatol Arthrosc ; 29(7): 2264-2271, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32710143

RESUMO

PURPOSE: To compare the clinical outcomes of patients who underwent successful nonoperative treatment for type III-V acromioclavicular joint (ACJ) injuries to those who eventually required conversion to anatomic coracoclavicular ligament reconstruction (ACCR) at a minimum 5-year follow-up. METHODS: Patients with primary, chronic type III-V ACJ injuries who either underwent successful conservative treatment or conversion to ACCR after failing a trail of conservative management between 2003 and 2014 with a minimum 5-year follow-up were included in the study. Clinical outcome measures comprised the American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test (SST) score, collected preoperatively and at final visit for the ACCR group. Outcome scores for patients with successful conservative treatment were only collected at final visit. A Self- Assessment Numeric Evaluation (SANE) score was obtained at terminal follow-up for both groups. RESULTS: Twenty-two patients (mean age: 40.1 ± 15.6 years) with successful nonoperative treatment and twenty-one patients (mean age: 43.6 ± 12.0 years) who required conversion to ACCR were included in the study. At final follow-up, patients with successful non-operative treatment achieved similar ASES (93.0±12.0NonOP vs. 86.1±16.8ACCR), SST (11.2±1.4NonOP vs. 10.7±2.0ACCR) and SANE scores (80.9±19.7NonOPvs. 90.5±14.7ACCR) compared to those who were converted to ACCR. Additionally, patients who underwent conversion to ACCR showed significant improvement in ASES (49.8±18.1pre vs. 86.1±16.8post; Δ36.3±19.7) and SST scores (6.5±3.2prevs. 10.7±2.0post; Δ4.2±4.0) from pre- to postoperative. CONCLUSION: At a minimum 5-year follow-up, patients with successful non-operative treatment for type III-V ACJ injuries achieved similar clinical outcomes compared to those who were converted to ACCR. In patients with chronic severe ACJ dislocation a trial of conservative treatment may be attempted, astime from injuryto eventual conversion to ACCR had no significant influence on postoperative clinical outcomes. LEVEL OF EVIDENCE: Level IV.


Assuntos
Articulação Acromioclavicular/lesões , Articulação Acromioclavicular/cirurgia , Tratamento Conservador/métodos , Ligamentos Articulares/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Adulto , Feminino , Seguimentos , Humanos , Luxações Articulares/cirurgia , Luxações Articulares/terapia , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Período Pós-Operatório , Estudos Retrospectivos , Ombro/cirurgia , Luxação do Ombro/cirurgia , Luxação do Ombro/terapia , Resultado do Tratamento , Adulto Jovem
9.
J Shoulder Elbow Surg ; 30(9): 2177-2183, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33529773

RESUMO

BACKGROUND AND HYPOTHESIS: The treatment of periprosthetic joint infection is complicated by the presence of residual biofilm, which resists eradication owing to bacterial adherence to orthopedic implants. The purpose of this study was to compare Bactisure (Zimmer Biomet, Warsaw, IN, USA), povidone-iodine (Betadine), and chlorhexidine gluconate solution (Irrisept; Irrimax, Gainesville, FL, USA) in reducing biofilm formation of Staphylococcus aureus, Staphylococcus epidermidis, and Cutibacterium acnes inoculated on cobalt-chrome, titanium, and stainless steel disks, representing metals commonly used for shoulder arthroplasty. The hypothesis was that there would be no significant difference in biofilm reduction among the 3 topical adjuvants. METHODS: Strains of S aureus (ATCC 35556), S epidermidis (ATCC 35984), and C acnes (LMG 16711) were grown on cobalt-chrome, titanium, and stainless steel disks. For each strain, the disks were divided into 4 groups: (1) control, (2) povidone-iodine (Betadine), (3) chlorhexidine gluconate (Irrisept), and (4) Bactisure. Bacteria were grown on 5% sheep blood agar plates. Biofilm eradication was quantified using adenosine triphosphate bioluminescence and compared with controls 48 and 72 hours after implementation of the topical adjuvant. RESULTS: At 72 hours after implementation of the topical adjuvant, a statistically significant reduction in colony-forming units was observed for all topical adjuvants across all tested metals, as compared with their respective control. With respect to the topical adjuvants themselves, Bactisure more consistently demonstrated the most significant reduction in colony-forming units across all bacteria when the tested medium was adjusted for, with the exception of S aureus, which showed similar results to Betadine at 72 hours. CONCLUSION: By use of commonly encountered topical adjuvants on S aureus-, S epidermidis-, and C acnes-inoculated disks of various implant metals, a significant reduction in biofilm production was observed. Bactisure, a recent Food and Drug Administration-approved topical adjuvant, demonstrated the overall greatest efficacy of the agents studied.


Assuntos
Infecções Relacionadas à Prótese , Animais , Biofilmes , Próteses e Implantes , Infecções Relacionadas à Prótese/prevenção & controle , Ovinos , Staphylococcus aureus , Staphylococcus epidermidis
10.
J Shoulder Elbow Surg ; 30(11): 2620-2628, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33964426

RESUMO

BACKGROUND: Posterior glenoid wear remains a challenge in anatomic and reverse total shoulder arthroplasty (rTSA) because of an asymmetric erosion with altered retroversion. The purpose of this study was to assess glenoid morphology and evaluate the influence of acromial orientation in posterior glenoid erosion patterns by using 3-dimensional (3D) models. MATERIAL AND METHODS: Computed tomographic (CT) shoulder scans from 3 study centers of patients awaiting rTSA between 2017 and 2018 were converted into 3D models and analyzed by 2 observers. Morphology, orientation and greatest depth of erosion, inclination, current retroversion and premorbid retroversion, surface areas of the glenoid, and external acromial orientation and posterior acromial slope were assessed. Measurements were compared between wear patterns, glenoid erosion entities, and genders. RESULTS: In the complete cohort of 68 patients (63.8 ± 10.0 years; 19 female, 49 male), a mean of 85.9° (±22.2°) was observed for the glenoid erosion orientation. Additionally, a further distinct classification of the glenoid erosion as posterior-central (PC, n = 39), posterior-inferior (PI, n = 12), and posterior-superior (PS, n = 17) wear patterns was possible. These wear patterns significantly (P < .001) distinguished by erosion orientation (PC = 86.9° ± 12.0°, PI = 116.3° ± 10.3°, PS = 62.3° ± 18.9°). The greatest depth of erosion found was 7.3 ± 2.7 mm in PC wear patterns (PC vs. PI: P = .03; PC vs. PS: n.s.; PI vs. PS: n.s.). Overall, the observed erosion divided the glenoid surface into a paleoglenoid proportion of 48% (±11%) and a neoglenoid proportion of 52% (±12%). For the complete cohort, glenoid inclination was 85.4° (±6.6°), premorbid glenoid retroversion was 80.7° (±8.1°), and current glenoid retroversion was 73.4° (±7.4°), with an estimated increase of 6.9° (±6.0°). The mean external acromial orientation was 118.2° (±8.9°), and the mean posterior acromial slope was 107.2° (±9.6°). There were no further significant differences if parameters were compared by wear patterns, entities, and gender. CONCLUSION: Three significantly differently oriented wear patterns (posterior-superior, posterior-central, and posterior-inferior) were distinguished in shoulders demonstrating posterior wear on axillary imaging. No significant differences between the observed erosion patterns or any relevant correlations were found regarding the orientation of the acromion.


Assuntos
Artroplastia do Ombro , Osteoartrite , Articulação do Ombro , Acrômio , Feminino , Humanos , Masculino , Osteoartrite/cirurgia , Escápula/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia
11.
Arthroscopy ; 36(1): 108-115, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31864562

RESUMO

PURPOSE: To analyze the posterior translational and rotational stability of the acromioclavicular (AC) joint following reconstruction of the superior acromioclavicular ligament complex (ACLC) using dermal allograft. METHODS: Six fresh-frozen cadaveric shoulders were used (mean age of 65.3 ± 6.9 years). The resistance force against posterior translation (10 mm) and torque against posterior rotation (20°) was measured. Specimens were first tested with both the intact ACLC and coracoclavicular ligaments. The ACLC and coracoclavicular ligaments were then transected so simulate a Type III/V AC joint dislocation. Each specimen then underwent 3 testing conditions, performed in the following order: (1) ACLC patch reconstruction alone, (2) ACLC patch with an anatomic coracoclavicular reconstruction (ACCR) using semitendinosus allograft, and (3) the transected ACLC with an ACCR only. Differences in posterior translational and rotational torque across testing conditions were analyzed with a one-way repeated analysis of variance analysis. RESULTS: Mean resistance against posterior translation in the intact condition was 65.76 ± 23.8 N. No significant difference found between the intact condition compared with specimens with the ACLC-patch only (44.2 ± 11.3 N, P = .06). The ACCR technique, when tested alone, had significantly less posterior translational resistance compared with the intact condition (38.5 ± 8.94 N, P = .008). ACLC patch in combination with an ACCR was closest in restoring native posterior translation (57.1 ± 19.2 N, P = .75). For rotational resistance, only the addition of the ACLC patch with an ACCR (0.51 ± 0.07 N-m) demonstrated similar torque compared with the intact joint (0.89 ± 0.5 N-m, P = .06). CONCLUSIONS: The ACLC-patch plus ACCR technique was able to closest restore the percent of normal posterior translational and rotational stability. CLINICAL RELEVANCE: Recurrent posterior instability of the AC joint is a potential complication after coracoclavicular reconstruction surgery. In the in vitro setting, this study demonstrated increased AC joint stability with the addition of an ACLC reconstruction using dermal allograft.


Assuntos
Articulação Acromioclavicular/cirurgia , Cápsula Articular/cirurgia , Luxações Articulares/cirurgia , Ligamentos Articulares/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Transplante de Pele/métodos , Articulação Acromioclavicular/fisiopatologia , Idoso , Aloenxertos , Fenômenos Biomecânicos , Cadáver , Humanos , Cápsula Articular/fisiopatologia , Luxações Articulares/fisiopatologia , Ligamentos Articulares/fisiopatologia
12.
Arthroscopy ; 36(8): 2057-2068, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32305423

RESUMO

PURPOSE: To classify subacromial bursal tissue using intraoperative and in vitro characteristics from specimens harvested during arthroscopic shoulder surgery. METHODS: Subacromial bursa was harvested over the rotator cuff from 48 patients (57 ± 10 years) undergoing arthroscopic shoulder surgery. Specimens were characterized intraoperatively by location (over rotator cuff tendon or muscle), tissue quality (percent of either fatty or fibrous infiltration), and vascularity before complete debridement. Nucleated cell counts were determined after 3 weeks incubation and histological sections were reviewed for degree of fatty infiltration and vascularity. Mesenchymal stem cell surface markers were counted via flow cytometry (n = 3) and cellular migration was observed using a fluoroscopic assay (n = 3). RESULTS: Intraoperatively, muscle bursa was found most often to have >50% fatty infiltration (n = 39), whereas tendon bursa showed majority fibrous tissue (n = 32). Cellular proliferation did not significantly differ according to intraoperative tissue quality. Intraoperative vascularity was associated with greater proliferation for highly vascular samples (P = 0.023). Tendon bursa demonstrated significantly greater proliferation potential than muscle bursa (P = 0.00015). Histologic assessment of fatty infiltration was moderately correlated with gross tissue fattiness (ρ = -0.626, P = 7.14 × 10-11). Flow cytometry showed that 90% to 100% of bursal cells were positive for MSC surface markers. Peak cellular migration rates occurred between 18 and 30 hours' incubation. CONCLUSIONS: Intraoperative and in vitro subacromial bursa characteristics were not found to reliably correlate with the degree of cellular proliferation. However, the anatomic location of subacromial bursa was consistently predictive of increased proliferation potential. Bursa-derived nucleated cells were confirmed to include mesenchymal stem cells with migratory potential. CLINICAL RELEVANCE: The anatomic distinction between muscle and tendon bursa provides a simple classification for predicting cellular activity.


Assuntos
Bolsa Sinovial/patologia , Artropatias/patologia , Artropatias/cirurgia , Articulação do Ombro/patologia , Articulação do Ombro/cirurgia , Adulto , Idoso , Artroscopia , Biópsia , Bolsa Sinovial/cirurgia , Proliferação de Células , Feminino , Humanos , Masculino , Células-Tronco Mesenquimais/patologia , Pessoa de Meia-Idade , Músculo Esquelético/patologia , Ombro/patologia , Ombro/cirurgia , Tendões/patologia
13.
Arthroscopy ; 36(6): 1542-1551, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32241704

RESUMO

PURPOSE: To evaluate the clinical outcomes of patients who underwent biologically enhanced patch augmentation repair for the treatment of revision massive rotator cuff tears. METHODS: Twenty-two patients who underwent arthroscopic and mini-open rotator cuff repair using a patch augmented with platelet-rich plasma and concentrated bone marrow aspirate (cBMA) for revision massive (≥2 tendons) rotator cuff tears from 2009 to 2014, with a minimum 1-year follow-up, were included in the study. In this procedure the medial side of the graft is secured to the rotator cuff tendon remaining medially. American Shoulder and Elbow Surgeons (ASES), Simple Shoulder Test, and postoperative Single Assessment Numerical Evaluation scores were evaluated. To determine the clinical relevance of ASES scores, the minimal clinically important difference, substantial clinical benefit (SCB), and the patient-acceptable symptomatic state (PASS) thresholds were used. Clinical success or failure was defined based on whether the patient reached the SCB threshold. In the laboratory, cellular counting along with the concentration of connective tissue progenitor cells were performed on patch samples from the day of surgery. Scaffolds were processed histologically at days 0, 7,14, and 21 of culture. RESULTS: Patients had significant improvement in the Simple Shoulder Test (2.6 ± 3.0pre vs 5.2 ± 4.2post, P = .01), whereas improvement in pain scores was found to be nonsignificant (5.6 ± 2.5pre vs 4.2 ± 3.4post,P = .11) at final follow-up. Mean ASES improved by Δ14.6 ± 33.4 points; however, this did not reach statistical significance (40.2 ± 21.6pre vs 53.9 ± 31.4post,P = .10). With regards to ASES score, 45% of patients achieved the minimal clinically important difference, 41% the SCB, and 32% reached or exceeded the PASS criteria. At 21 days, there was a significantly greater cell count in scaffolds from patients who had clinical success than those who were failures (P = .02). CONCLUSIONS: Only 41% of patients undergoing biologically enhanced patch augmentation repair reached substantial clinical benefit, whereas 32% reached or exceeded the PASS criteria. LEVEL OF EVIDENCE: Case Series: Level IV.


Assuntos
Lesões do Manguito Rotador/cirurgia , Telas Cirúrgicas , Artroscopia , Medula Óssea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Plasma Rico em Plaquetas , Complicações Pós-Operatórias , Amplitude de Movimento Articular , Lesões do Manguito Rotador/patologia , Resultado do Tratamento
14.
Arthroscopy ; 36(2): 400-408, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31902546

RESUMO

PURPOSE: To evaluate the effect of dermal allograft fixation at different angles of glenohumeral abduction on deltoid forces during superior capsule reconstruction (SCR). METHODS: Fifteen cadaveric specimens were tested using a dynamic shoulder simulator. Following testing in the native state, shoulders underwent SCR in 2 of 5 possible fixation angles; 0°, 15°, 30°, 45°, or 60° of glenohumeral abduction, allowing for 6 specimens per group. Angles were measured radiographically with the glenoid fixed perpendicular to the floor. Maximum mean deltoid abduction force was compared among 5 separate conditions within each angle group: (1) native shoulder, (2) complete supraspinatus (SSP) and superior capsule tear, (3) SCR alone, (4) SCR with posterior margin sutured, and (5) SCR with anterior and posterior margins sutured. RESULTS: SSP tears significantly increased the maximum deltoid forces for all 5 fixation angles compared with the native state (P < .05). Specimens repaired at 0°, 30°, and 45° were unable to restore deltoid forces compared with the native state in any condition (P < .05). SCR at 15° with anterior and posterior margin convergence showed similar abduction forces compared with the native state (P = .19). When fixed at 60° abduction, SCR alone significantly reduced deltoid forces compared to SSP (Δ143N, P < .001) and native (Δ48N, P < .001). No significant differences were found between the 3 repair subtypes (SCR ± anterior/posterior margin repair) in the 60° group. CONCLUSIONS: SCR with anterior and posterior margin convergence tensioned at 15° of glenohumeral abduction showed similar deltoid abduction force requirements compared with the native state, whereas graft fixation in 60° significantly reduced deltoid force in all SCR conditions. CLINICAL RELEVANCE: Increased graft tension with a greater abduction angle may provide greater functional outcome by placing less load on the deltoid. In contrast, graft fixation in lower abduction angles may require additional margin convergence to reproduce native forces.


Assuntos
Artroscopia/métodos , Músculo Deltoide/fisiologia , Cápsula Articular/cirurgia , Articulação do Ombro/cirurgia , Derme Acelular , Idoso , Aloenxertos , Fenômenos Biomecânicos/fisiologia , Cadáver , Humanos , Pessoa de Meia-Idade , Lesões do Manguito Rotador/cirurgia
15.
Arthroscopy ; 36(11): 2794-2802, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32554077

RESUMO

PURPOSE: To investigate the influence of patient demographics and rotator cuff tear characteristics on the cellular proliferation potential of subacromial bursa-derived cells (SBDCs). METHODS: Patients undergoing arthroscopic rotator cuff repair between December 2017 and February 2019 were considered for enrollment in the study. Basic demographic information as well as medical and surgical history were obtained for each patient. Subacromial bursa was harvested from over the rotator cuff tendon. Cellular proliferation was evaluated after 3 weeks of incubation by counting nucleated SBDCs. Fluorescence-activated cell sorting (FACS) analysis was performed to confirm the presence of mesenchymal stem cell (MSC) specific surface markers. Using preoperative radiographs and magnetic resonance imaging (MRI), acromiohumeral distance (AHD), severity of cuff tear arthropathy, and rotator cuff tear characteristics were evaluated. RESULTS: Seventy-three patients (mean age: 57.2 ± 8.5 years) were included in the study. There was no significant difference in cellular proliferation of SBDCs when evaluating the influence of age, sex, body mass index (BMI), smoking status, and presence of systemic comorbidities (p > .05, respectively). Similarly, there was no significant difference in cellular proliferation of SBDCs when looking at rotator cuff tear characteristics (size, tendon retraction, fatty infiltration, muscle atrophy), AHD, or severity of cuff tear arthropathy (p > .05). FACS analysis confirmed nucleated SBDCs to have a high positive rate of MSC specific surface markers. CONCLUSION: Subacromial bursa consistently demonstrated a high cellular proliferation potential regardless of patient demographics, rotator cuff tear characteristics, and severity of glenohumeral joint degeneration. CLINICAL RELEVANCE: These findings may alleviate concerns that subacromial bursa might lose cellular proliferation potential when being used for biologic augmentation in massive and degenerated rotator cuff tears, thus assisting in predicting tendon healing and facilitating surgical decision-making.


Assuntos
Artroscopia , Bolsa Sinovial/citologia , Lesões do Manguito Rotador/cirurgia , Manguito Rotador/cirurgia , Adulto , Idoso , Proliferação de Células , Células Cultivadas , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Células-Tronco Mesenquimais/citologia , Pessoa de Meia-Idade , Procedimentos de Cirurgia Plástica , Articulação do Ombro/cirurgia , Tendões/cirurgia
16.
Arthroscopy ; 36(9): 2403-2411, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32554079

RESUMO

PURPOSE: The purpose of this study was to evaluate the number of colony-forming units (CFUs) derived from concentrated bone marrow aspirates (BMAs) that were processed following arthroscopic harvest from either the proximal humerus or the body of the ilium during biologic augmentation of the rotator cuff and acetabular labral repairs. METHODS: Between November 2014 and January 2019, BMA was harvested from the proximal humerus (n = 89) and the body of the ilium (n = 30) during arthroscopic surgery. Following concentration of the aspirate, a 0.5-mL aliquot was further processed and the number of nucleated cells (NC) was counted. Each aliquot was cultured until CFUs were quantifiable. Fluorescence-activated cell sorting analysis and quantitative polymerase chain reaction was performed to confirm presence of mesenchymal stem cells. BMA harvest sites were prospectively assessed and evaluated for differences in age, sex, volume of aspirated BM, and CFUs per milliliter of BMA. RESULTS: The prevalence (38.57 ± 27.92ilium vs. 56.00 ± 25.60humerus CFUs per 106 nucleated cells) and concentration (979.17 ± 740.31ilium vs. 1,516.62 ± 763.63humerus CFUs per 1.0 mL BMA) of CFUs was significantly higher (P < .001, respectively) for BMA harvested from the proximal humerus. Additionally, the estimated total number of cells was significantly higher (P = .013) in BMA from the proximal humerus (97,529.00 ± 91,064.01ilium vs. 130,552.4 ± 85,294.2humerus). There was no significant difference between groups regarding BMA volume (91.67 ± 18.77ilium vs. 85.63 ± 35.61humerus mL; P = .286) and NC count (24.01 ± 5.13ilium vs. 27.07 ± 6.28humerus × 106 per mL BMA; P = .061). The mean age was significantly lower (P < .001) in patients with BMA being harvested from the ilium (30.18 ± 7.63ilium vs. 56.82 ± 7.08humerus years). Patient sex and age had no significant influence on cellular measures within groups (P > .05, respectively). CONCLUSION: Both proximal humerus and the body of the ilium can be considered reliable sources of bone marrow aspirate for the use in biologic augmentation during their respective arthroscopic surgery. Samples of bone marrow aspirate from the proximal humerus yielded a significantly higher amount of CFUs when compared with samples of BMA obtained from the ilium. LEVEL OF EVIDENCE: Level II- prospective laboratorial study.


Assuntos
Artroscopia , Transplante de Medula Óssea , Medula Óssea , Úmero/patologia , Ílio/patologia , Manguito Rotador/cirurgia , Adipogenia , Adulto , Cartilagem Articular , Contagem de Células , Diferenciação Celular , Separação Celular , Condrogênese , Feminino , Citometria de Fluxo , Humanos , Masculino , Células-Tronco Mesenquimais/citologia , Pessoa de Meia-Idade , Osteogênese , Estudos Prospectivos , Células-Tronco , Adulto Jovem
17.
Arthroscopy ; 36(2): 355-364, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31791890

RESUMO

PURPOSE: To biomechanically compare the effect of superior capsule reconstruction (SCR) using a 3- and 6-mm thick acellular dermal allograft for the treatment of irreparable rotator cuff tears. METHODS: Eight fresh-frozen cadaveric shoulders were tested using a dynamic shoulder model. Maximum abduction angle (MAA), glenohumeral superior translation (ghST), subacromial peak contact pressure (sPCP), and cumulative deltoid force (cDF) were compared among 4 conditions: (1) intact shoulder, (2) simulated irreparable rotator cuff tear (RCT), (3) SCR using a 3-mm-thick acellular dermal allograft, (4) SCR using a 6-mm-thick acellular dermal allograft. RESULTS: Compared with the intact state, simulated irreparable RCTs significantly decreased MAA (P < .001), while significantly increasing ghST (P = .001), sPCP (P < .001), and cDF (P < .001). SCR with a 3-mm-thick graft significantly increased MAA (P = .01) and decreased ghST (P = .01) compared with the RCT state, however, showed similar sPCP and cDF. Compared with the torn state, SCR with a 6-mm-thick graft significantly increased MAA (P < .001) and significantly decreased ghST (P < .001), sPCP (P < .001), and cDF (P = .001). Using a 6-mm-thick graft demonstrated similar MAA, ghST, sPCP, and cDF compared with the intact state. When comparing the 3-mm to the 6-mm thick graft, significant differences were found in ghST (P = .03), sPCP (P < .001), and cDF (P = .02). CONCLUSIONS: SCR with a 6-mm-thick acellular dermal allograft better restored normal glenohumeral joint position and forces compared with a 3-mm-thick graft for the treatment of irreparable RCTs. CLINICAL RELEVANCE: Graft thickness may affect the clinical success following SCR with commercially available dermal allografts. Using a thicker (>3 mm) graft was able to biomechanically better restore native glenohumeral joint properties.


Assuntos
Derme Acelular , Amplitude de Movimento Articular , Lesões do Manguito Rotador/cirurgia , Idoso , Aloenxertos , Fenômenos Biomecânicos , Cadáver , Humanos , Pessoa de Meia-Idade
18.
Arthroscopy ; 36(1): 88-94, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31864605

RESUMO

PURPOSE: To evaluate the clinical success rate, along with risk factors for failure, in patients undergoing latissimus dorsi transfer for the treatment of massive, irreparable, previously failed rotator cuff tears. METHODS: We performed a retrospective chart review of prospectively collected data from an institutional shoulder outcome registry. All patients who underwent latissimus dorsi transfer for previously failed rotator cuff repair between 2006 and 2013 with a minimum follow-up period of 1 year were included in the study. The indications for inclusion were large (≥2 tendons), retracted, chronic rotator cuff tears with fatty infiltration or atrophy for which prior surgical repair had failed. Preoperative and postoperative American Shoulder and Elbow Surgeons (ASES) and Simple Shoulder Test scores were collected, along with postoperative Single Assessment Numerical Evaluation scores. Complications and clinical failures (Δ in ASES score <17) were recorded. Patient demographic and tear characteristics were evaluated as potential risk factors for failure. RESULTS: A total of 22 patients (mean age, 53 ± 6 years) were included in the study, with a mean follow-up time of 3.4 ± 1.1 years. Over 63% of patients (n = 14) reported undergoing 2 or more prior failed rotator cuff repairs. Patients undergoing latissimus dorsi transfer showed significant improvements in ASES scores (from 35.2 ± 21.9 preoperatively to 55.8 ± 22.9 postoperatively, P = .001), Simple Shoulder Test scores (from 3.5 ± 3.1 preoperatively to 5.2 ± 3.4 postoperatively, P = .002), and pain scores (from 5.9 ± 2.8 preoperatively to 4.6 ± 4.3 postoperatively, P = .002) at final follow-up. The complication rate after latissimus transfer was 27%. The rate of revision to reverse total shoulder arthroplasty was 13.6% (n = 3) after a mean of 2.7 years, and the clinical failure rate was 41% (n = 9) at final follow-up. An acromiohumeral interval of less than 7 mm (P = .04) and high-grade fatty infiltration (grade 3 or greater, P = .004) were significant preoperative risk factors for clinical failure. CONCLUSIONS: Latissimus dorsi tendon transfer resulted in a clinical failure rate of 41% and complication rate of 27%, with an acromiohumeral interval of less than 7 mm and high-grade fatty infiltration being associated with postoperative failure. LEVEL OF EVIDENCE: Level IV.


Assuntos
Lesões do Manguito Rotador/cirurgia , Manguito Rotador/cirurgia , Articulação do Ombro/cirurgia , Músculos Superficiais do Dorso/cirurgia , Transferência Tendinosa/métodos , Tendões/cirurgia , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Retrospectivos , Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/diagnóstico , Ruptura , Articulação do Ombro/diagnóstico por imagem , Músculos Superficiais do Dorso/diagnóstico por imagem , Resultado do Tratamento
19.
Arthroscopy ; 36(1): 80-85, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31708351

RESUMO

PURPOSE: To identify an effective, nonenzymatic method for maximizing the yield of subacromial bursa-derived nucleated cells for augmenting rotator cuff repair. METHODS: Subacromial bursa (minimum 0.2 g) was collected prospectively over the supraspinatus from patients (n = 7) with at least one full-thickness tendon tear undergoing arthroscopic primary rotator cuff repair. Samples were processed and analyzed prospectively using 4 different methods: (1) mechanical digestion with scissors (chopping), (2) collagenase digestion, (3) mechanical digestion with a tissue homogenizer, and (4) whole tissue with minimal manipulation. Tissue from each method were plated and cultured in a low oxygen tension, humidified incubator for 7 days. Following incubation, cellularity was assessed with nucleated cell count using a Coulter Counter. Flow cytometry was performed on the non-enzymatic method that demonstrated the greatest cell count to confirm the presence of mesenchymal stem cells (MSCs). The Kruskal-Wallis H test and post hoc Dunn's test were used for statistical analysis. RESULTS: Following incubation, mean nucleated cell counts (cells/mL) were (1) 102,681 ± 73,249 for chopping, (2) 76,190 ± 66,275 for collagenase, (3) 31,686 ± 29,234 for homogenization, and (4) 11,162 ± 4016 for whole tissue. There was no significant difference between chopping and collagenase (P = .45) or between homogenization and collagenase (P = .52). Both chopping (P = .003) and collagenase (P = .03) produced significantly more cells when compared with whole tissue. Flow cytometry confirmed the presence of MSC markers on samples processed by chopping. CONCLUSIONS: Mechanical isolation of subacromial bursa-derived cells using a chopping technique demonstrated similar nucleated cell count compared with collagenase, along with the confirmed presence of MSCs. CLINICAL RELEVANCE: This study demonstrated a nonenzymatic, mechanical method for isolating subacromial bursa-derived cells to potentially augment rotator cuff repair. Further clinical studies are required to assess its possible advent in the tendon-bone healing process.


Assuntos
Artroscopia/métodos , Bolsa Sinovial/cirurgia , Células-Tronco Mesenquimais/citologia , Procedimentos de Cirurgia Plástica/métodos , Lesões do Manguito Rotador/cirurgia , Manguito Rotador/cirurgia , Cicatrização , Contagem de Células , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
20.
Knee Surg Sports Traumatol Arthrosc ; 28(4): 1195-1201, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31352495

RESUMO

PURPOSE: Posterolateral rotatory instability (PLRI) of the elbow occurs from an insufficient lateral collateral ligament complex (LCLC). For subacute LCLC injuries, lateral ulnar collateral ligament (LUCL) internal bracing rather than reconstruction may be a viable option. The purpose of the study was to compare the stabilizing effects of LUCL internal bracing to triceps tendon graft reconstruction in simulated PLRI. METHODS: Sixteen cadaveric elbows were assigned for either LUCL internal bracing (n = 8) or reconstruction with triceps tendon graft (n = 8). Specimen were mounted and a valgus rotational torque was applied to the ulna to test posterolateral rotatory stability. Posterolateral rotation was measured at 0°, 30°, 60°, 90° and 120° of elbow flexion. Cyclic loading was performed for 1000 cycles at 90° of elbow flexion. Three conditions were compared in each specimen: intact elbow, LUCL and radial collateral ligament (RCL) transected, and then either LUCL internal bracing or reconstruction with triceps tendon graft. RESULTS: Transection of the LUCL and RCL significantly increased posterolateral rotation in all degrees of elbow flexion compared to the intact condition (P < 0.05). Both LUCL internal bracing and reconstruction restored posterolateral rotatory stability to the native state between 0° and 120° of elbow flexion, with no significant difference in improvement between groups. Similarly, LUCL internal bracing and reconstruction groups showed no significant difference in posterolateral rotation compared to the intact condition during cyclic loading. CONCLUSIONS: At time zero, both LUCL internal bracing and reconstruction with triceps tendon graft restored posterolateral rotatory stability. As such, this study supports the use of internal bracing as an adjunct to primary ligament repair in subacute PLRI.


Assuntos
Ligamento Colateral Ulnar/cirurgia , Articulação do Cotovelo/cirurgia , Instabilidade Articular/cirurgia , Procedimentos Ortopédicos/métodos , Procedimentos de Cirurgia Plástica/métodos , Tendões/transplante , Idoso , Fenômenos Biomecânicos , Braquetes , Cadáver , Articulação do Cotovelo/fisiopatologia , Feminino , Humanos , Instabilidade Articular/fisiopatologia , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa