1.
MAGMA ; 23(1): 39-43, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20012152

RESUMO

INTRODUCTION: Eddy currents induced by switching of magnetic field gradients can lead to distortions in short echo-time spectroscopy or diffusion weighted imaging. In small bore magnets, such as human head-only systems, minimization of eddy current effects is more demanding because of the proximity of the gradient coil to conducting structures. METHODS: In the present study, the eddy current behavior achievable on a recently installed 7 tesla-68 cm bore head-only magnet was characterized. RESULTS: Residual effects after compensation were shown to be on the same order of magnitude as those measured on two whole body systems (3 and 4.7 T), while using two to three fold increased gradient slewrates.


Assuntos
Impedância Elétrica , Campos Eletromagnéticos , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/instrumentação , Magnetismo , Imagem Corporal Total , Cabeça/patologia , Cabeça/fisiologia , Humanos , Imagens de Fantasmas
2.
J Cereb Blood Flow Metab ; 27(11): 1830-40, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17392693

RESUMO

The glutamate-glutamine shuttle requires a flux of fixed N from neurons to astrocytes. The suggestion that some or all of this N is ammonium has received support from reports that ammonium (as NH(4)(+)) rapidly enters astrocytes. Ammonium might also help control astrocyte energy metabolism by increasing lactate production. If ammonium has these functions, then its effect on brain metabolism must be rapid and reversible. To make a minimal test of this requirement, we have followed the time courses of the changes induced by a 4 min venous infusion of 1 mol/L NH(4)Cl, 2.5 mmol/kg body weight, in rat. Extracellular [NH(4)(+)] in cortex, monitored with ion-selective microelectrodes, reached a peak of approximately 0.7 mmol/L 1.65 mins after the end of the infusion, then recovered. Brain metabolites were monitored non-invasively every 4 mins by (1)H magnetic resonance spectroscopy. Lactate peak area during the 3.2 min acquisition starting at the end of the infusion was 1.84+/-0.24 times baseline (+/-s.e.m., P=0.009, n=9). Lactate increased until 13.2+/-2.1 mins after the end of the infusion and recovered halfway to baseline by 31.2 mins. Glutamate decreased by at least 7.1% (P=0.0026). Infusion of NaCl caused no change in lactate signal. Cerebral blood flow, measured by arterial magnetization labeling, more than doubled, suggesting that the lactate increase was not caused by hypoxia. At least three consecutive ammonium-induced increases in lactate signal could be evoked. The results are compatible with an intercellular trafficking/signaling function for ammonium.


Assuntos
Química Encefálica/efeitos dos fármacos , Ácido Láctico/metabolismo , Compostos de Amônio Quaternário/farmacologia , Transdução de Sinais/fisiologia , Cloreto de Amônio/farmacologia , Animais , Astrócitos/metabolismo , Circulação Cerebrovascular/fisiologia , Interpretação Estatística de Dados , Eletrodos Implantados , Espaço Extracelular/efeitos dos fármacos , Espaço Extracelular/metabolismo , Ácido Glutâmico/isolamento & purificação , Ácido Glutâmico/metabolismo , Homeostase/fisiologia , Processamento de Imagem Assistida por Computador , Espectroscopia de Ressonância Magnética , Masculino , Neurônios/metabolismo , Potássio/metabolismo , Ratos , Ratos Wistar , Transdução de Sinais/efeitos dos fármacos , Cloreto de Sódio/farmacologia , Resistência Vascular/efeitos dos fármacos , Resistência Vascular/fisiologia , Vasodilatação/fisiologia
3.
IEEE Trans Med Imaging ; 32(8): 1515-25, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23674437

RESUMO

Clinical use of the Stejskal-Tanner diffusion weighted images is hampered by the geometric distortions that result from the large residual 3-D eddy current field induced. In this work, we aimed to predict, using linear response theory, the residual 3-D eddy current field required for geometric distortion correction based on phantom eddy current field measurements. The predicted 3-D eddy current field induced by the diffusion-weighting gradients was able to reduce the root mean square error of the residual eddy current field to ~1 Hz. The model's performance was tested on diffusion weighted images of four normal volunteers, following distortion correction, the quality of the Stejskal-Tanner diffusion-weighted images was found to have comparable quality to image registration based corrections (FSL) at low b-values. Unlike registration techniques the correction was not hindered by low SNR at high b-values, and results in improved image quality relative to FSL. Characterization of the 3-D eddy current field with linear response theory enables the prediction of the 3-D eddy current field required to correct eddy current induced geometric distortions for a wide range of clinical and high b-value protocols.


Assuntos
Imagem de Tensor de Difusão/métodos , Imageamento Tridimensional/métodos , Encéfalo/anatomia & histologia , Encéfalo/fisiologia , Campos Eletromagnéticos , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Razão Sinal-Ruído
4.
J Magn Reson ; 203(1): 108-12, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20042355

RESUMO

The double spin-echo point resolved spectroscopy sequence (PRESS) is a widely used method and standard in clinical MR spectroscopy. Existence of important J-modulations at constant echo times, depending on the temporal delays between the rf-pulses, have been demonstrated recently for strongly coupled spin systems and were exploited for difference editing, removing singlets from the spectrum (strong-coupling PRESS, S-PRESS). A drawback of this method for in vivo applications is that large signal modulations needed for difference editing occur only at relatively long echo times. In this work we demonstrate that, by simply adding a third refocusing pulse (3S-PRESS), difference editing becomes possible at substantially shorter echo times while, as applied to citrate, more favorable lineshapes can be obtained. For the example of an AB system an analytical description of the MR signal, obtained with this triple refocusing sequence (3S-PRESS), is provided.


Assuntos
Algoritmos , Ressonância Magnética Nuclear Biomolecular/métodos , Calibragem , Citratos/química , Campos Eletromagnéticos , Humanos , Masculino , Próstata/química
5.
NMR Biomed ; 20(8): 757-62, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17334978

RESUMO

Loss of nigral dopamine neurons in Parkinson's disease induces abnormal activation of glutamate systems in the basal ganglia. The purpose of this study was to assess these changes in the lentiform nucleus using MRS with optimized glutamate sensitivity (TE-averaged method). Ten patients with Parkinson's disease and 10 healthy controls were examined. Compared with healthy controls, no significant differences in glutamate were measured in patients, but a trend to lower total creatine was observed.


Assuntos
Corpo Estriado/metabolismo , Ácido Glutâmico/metabolismo , Doença de Parkinson/metabolismo , Antiparkinsonianos/uso terapêutico , Ácido Aspártico/análogos & derivados , Ácido Aspártico/metabolismo , Creatina/metabolismo , Glutamina/metabolismo , Humanos , Levodopa/uso terapêutico , Espectroscopia de Ressonância Magnética , Doença de Parkinson/diagnóstico , Doença de Parkinson/tratamento farmacológico , Valores de Referência , Ácido gama-Aminobutírico/metabolismo