Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 366
Filtrar
1.
Nature ; 609(7928): 701-708, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36131035

RESUMO

Dynamic shape-morphing soft materials systems are ubiquitous in living organisms; they are also of rapidly increasing relevance to emerging technologies in soft machines1-3, flexible electronics4,5 and smart medicines6. Soft matter equipped with responsive components can switch between designed shapes or structures, but cannot support the types of dynamic morphing capabilities needed to reproduce natural, continuous processes of interest for many applications7-24. Challenges lie in the development of schemes to reprogram target shapes after fabrication, especially when complexities associated with the operating physics and disturbances from the environment can stop the use of deterministic theoretical models to guide inverse design and control strategies25-30. Here we present a mechanical metasurface constructed from a matrix of filamentary metal traces, driven by reprogrammable, distributed Lorentz forces that follow from the passage of electrical currents in the presence of a static magnetic field. The resulting system demonstrates complex, dynamic morphing capabilities with response times within 0.1 second. Implementing an in situ stereo-imaging feedback strategy with a digitally controlled actuation scheme guided by an optimization algorithm yields surfaces that can follow a self-evolving inverse design to morph into a wide range of three-dimensional target shapes with high precision, including an ability to morph against extrinsic or intrinsic perturbations. These concepts support a data-driven approach to the design of dynamic soft matter, with many unique characteristics.

2.
Nature ; 597(7877): 503-510, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34552257

RESUMO

Large, distributed collections of miniaturized, wireless electronic devices1,2 may form the basis of future systems for environmental monitoring3, population surveillance4, disease management5 and other applications that demand coverage over expansive spatial scales. Aerial schemes to distribute the components for such networks are required, and-inspired by wind-dispersed seeds6-we examined passive structures designed for controlled, unpowered flight across natural environments or city settings. Techniques in mechanically guided assembly of three-dimensional (3D) mesostructures7-9 provide access to miniature, 3D fliers optimized for such purposes, in processes that align with the most sophisticated production techniques for electronic, optoelectronic, microfluidic and microelectromechanical technologies. Here we demonstrate a range of 3D macro-, meso- and microscale fliers produced in this manner, including those that incorporate active electronic and colorimetric payloads. Analytical, computational and experimental studies of the aerodynamics of high-performance structures of this type establish a set of fundamental considerations in bio-inspired design, with a focus on 3D fliers that exhibit controlled rotational kinematics and low terminal velocities. An approach that represents these complex 3D structures as discrete numbers of blades captures the essential physics in simple, analytical scaling forms, validated by computational and experimental results. Battery-free, wireless devices and colorimetric sensors for environmental measurements provide simple examples of a wide spectrum of applications of these unusual concepts.


Assuntos
Biomimética , Equipamentos e Provisões Elétricas , Miniaturização/instrumentação , Sementes , Vento , Tecnologia sem Fio/instrumentação , Colorimetria , Monitoramento Ambiental/instrumentação , Monitoramento Ambiental/métodos , Fenômenos Mecânicos , Microfluídica , Vigilância da População/métodos , Rotação
3.
Proc Natl Acad Sci U S A ; 121(22): e2404007121, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38768347

RESUMO

Sensations of heat and touch produced by receptors in the skin are of essential importance for perceptions of the physical environment, with a particularly powerful role in interpersonal interactions. Advances in technologies for replicating these sensations in a programmable manner have the potential not only to enhance virtual/augmented reality environments but they also hold promise in medical applications for individuals with amputations or impaired sensory function. Engineering challenges are in achieving interfaces with precise spatial resolution, power-efficient operation, wide dynamic range, and fast temporal responses in both thermal and in physical modulation, with forms that can extend over large regions of the body. This paper introduces a wireless, skin-compatible interface for thermo-haptic modulation designed to address some of these challenges, with the ability to deliver programmable patterns of enhanced vibrational displacement and high-speed thermal stimulation. Experimental and computational investigations quantify the thermal and mechanical efficiency of a vertically stacked design layout in the thermo-haptic stimulators that also supports real-time, closed-loop control mechanisms. The platform is effective in conveying thermal and physical information through the skin, as demonstrated in the control of robotic prosthetics and in interactions with pressure/temperature-sensitive touch displays.


Assuntos
Tato , Realidade Virtual , Tecnologia sem Fio , Humanos , Tecnologia sem Fio/instrumentação , Tato/fisiologia , Pele , Robótica/instrumentação , Robótica/métodos
4.
Proc Natl Acad Sci U S A ; 120(6): e2217828120, 2023 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-36716364

RESUMO

Thermal sensations contribute to our ability to perceive and explore the physical world. Reproducing these sensations in a spatiotemporally programmable manner through wireless computer control could enhance virtual experiences beyond those supported by video, audio and, increasingly, haptic inputs. Flexible, lightweight and thin devices that deliver patterns of thermal stimulation across large areas of the skin at any location of the body are of great interest in this context. Applications range from those in gaming and remote socioemotional communications, to medical therapies and physical rehabilitation. Here, we present a set of ideas that form the foundations of a skin-integrated technology for power-efficient generation of thermal sensations across the skin, with real-time, closed-loop control. The systems exploit passive cooling mechanisms, actively switchable thermal barrier interfaces, thin resistive heaters and flexible electronics configured in a pixelated layout with wireless interfaces to portable devices, the internet and cloud data infrastructure. Systematic experimental studies and simulation results explore the essential mechanisms and guide the selection of optimized choices in design. Demonstration examples with human subjects feature active thermoregulation, virtual social interactions, and sensory expansion.


Assuntos
Pele , Realidade Virtual , Humanos , Eletrônica , Sensação Térmica , Comunicação
5.
Proc Natl Acad Sci U S A ; 119(46): e2214164119, 2022 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-36343234

RESUMO

A quantitative understanding of the coupled dynamics of flow and particles in aerosol and droplet transmission associated with speech remains elusive. Here, we summarize an effort that integrates insights into flow-particle dynamics induced by the production plosive sounds during speech with skin-integrated electronic systems for monitoring the production of these sounds. In particular, we uncover diffusive and ballistic regimes separated by a threshold particle size and characterize the Lagrangian acceleration and pair dispersion. Lagrangian dynamics of the particles in the diffusive regime exhibit features of isotropic turbulence. These fundamental findings highlight the value in skin-interfaced wireless sensors for continuously measuring critical speech patterns in clinical settings, work environments, and the home, based on unique neck biomechanics associated with the generation of plosive sounds. We introduce a wireless, soft device that captures these motions to enable detection of plosive sounds in multiple languages through a convolutional neural network approach. This work spans fundamental flow-particle physics to soft electronic technology, with implications in monitoring and studying critical speech patterns associated with aerosol and droplet transmissions relevant to the spread of infectious diseases.


Assuntos
Eletrônica , Fala , Aerossóis , Tamanho da Partícula , Movimento (Física)
6.
BMC Anesthesiol ; 24(1): 151, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649838

RESUMO

BACKGROUND: General anesthesia is often necessary for dental treatment of outpatients with mental disabilities. Rapid recovery and effective management of postoperative nausea and vomiting (PONV) are critical for outpatients. This study aimed to investigate the effect of transitioning from propofol to remimazolam with flumazenil reversal administered toward the end of surgery during propofol-based total intravenous anesthesia (TIVA) on recovery. METHODS: Adults with mental disabilities scheduled to undergo dental treatment were randomly assigned to receive either propofol-based TIVA (Group P) or propofol-remimazolam-based TIVA with flumazenil reversal (Group PR). Propofol was replaced with remimazolam 1 h before the end of surgery in Group PR; moreover, 0.5 mg of flumazenil was administered after the neuromuscular blockade reversal agent. The primary outcome was the duration of stay in the post-anesthesia care unit (PACU). The secondary outcomes included time to eye-opening, time to extubation, occurrence of PONV, and quality of recovery. RESULTS: Fifty-four patients were included in this study. The duration of stay in the PACU in Group PR was significantly shorter than that in Group P (mean difference, 8.7 min; confidence interval [95% CI], 3.3-14.2; P = 0.002). Group PR exhibited a shorter time to eye opening (mean difference, 5.4 min; 95% CI, 3.3-8.1; P < 0.001) and time to extubation (mean difference, 5.5 min; 95% CI, 3.6-7.9; P < 0.001) than Group P. Neither group required the administration of rescue analgesics, and the incidence of PONV was not reported. CONCLUSIONS: Transitioning from propofol to remimazolam 1 h before the end of surgery followed by flumazenil reversal reduced the duration of stay in the PACU and the time to eye opening and extubation without affecting the incidence of PONV and quality of recovery. TRIAL REGISTRATION NUMBER: Clinical Research Information Service (KCT0007794), Clinical trial first registration date: 12/10/2022.


Assuntos
Período de Recuperação da Anestesia , Anestésicos Intravenosos , Flumazenil , Propofol , Humanos , Flumazenil/uso terapêutico , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Benzodiazepinas/administração & dosagem , Náusea e Vômito Pós-Operatórios , Tempo de Internação/estatística & dados numéricos , Pacientes Ambulatoriais
7.
Paediatr Anaesth ; 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38693633

RESUMO

AIMS: This study determined the optimal positive end-expiratory pressure levels in infants in supine and prone positions under general anesthesia using electrical impedance tomography (EIT). METHODS: This prospective observational single-centre study included infants scheduled for surgery in the prone position. An electrical impedance tomography sensor was applied after inducing general anesthesia. The optimal positive end-expiratory pressure in the supine position was determined in a decremental trial based on EIT and compliance. Subsequently, the patient's position was changed to prone. Electrical impedance tomography parameters, including global inhomogeneity index, regional ventilation delay, opening pressure, the centre of ventilation, and pendelluft volume, were continuously obtained up to 1 h after prone positioning. The optimal positive end-expiratory pressure in the prone position was similarly determined. RESULTS: Data from 30 infants were analyzed. The mean value of electrical impedance tomography-based optimal positive end-expiratory pressure in the prone position was significantly higher than that in the supine position [10.9 (1.6) cmH2O and 6.1 (0.9) cmH2O, respectively (p < .001)]. Significant differences were observed between electrical impedance tomography- and compliance-based optimal positive end-expiratory pressure. Peak and mean airway, plateau, and driving pressures increased 1 h after prone positioning compared with those in the supine position. In addition, the centre of ventilation for balance in ventilation between the ventral and dorsal regions improved. CONCLUSION: The prone position required higher positive end-expiratory pressure than the supine position in mechanically ventilated infants under general anesthesia. EIT is a promising tool to find the optimal positive end-expiratory pressure, which needs to be individualized.

8.
Paediatr Anaesth ; 34(1): 35-41, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37587734

RESUMO

BACKGROUND: Optimal pain management after insertion of a central venous catheter in children remains unclear. AIM: This study aimed to evaluate the effects of a selective supraclavicular nerve block on postoperative analgesia in pediatric patients undergoing hickman catheter or chemoport insertion. METHODS: Fifty patients aged 3-18 years scheduled for elective Hickman or chemoport insertion were randomized into two groups of 25 each: one group received an ultrasound-guided selective supraclavicular nerve block with 0.1 mL/kg of 0.5% ropivacaine (SSCNB group), and the other group did not receive a nerve block (control group). The primary outcome was the postoperative Wong-Baker Faces Pain Rating Scale score measured between 10 and 30 min after surgery. Secondary outcomes included pain scores at 1, 3, and 24 h after the surgery, block-related complications, length of stay in the postanesthesia care unit, postoperative analgesic consumption, and time to first analgesic use 24 h after surgery. RESULTS: The worst pain score within 30 min in the recovery room was significantly lower in the SSCNB group compared to the control group (6 [5-7] vs. 3 [2-4]; median difference, -3; 95% CI, -4 to -1; p < .001). Pain scores at 1, 3, and 24 h after surgery were also significantly lower in the SSCNB group. The need for both opioid and non-opioid analgesics in the postoperative period was significantly lower in the SSCNB group (36.0% vs. 0%; p = .002 and 44.0% vs. 16.0%; mean difference, -28%; 95% CI, -56 to 0.19; p = .033, respectively), while other secondary outcomes were not significantly different between the two groups. CONCLUSIONS: Ultrasound-guided SSCNB is an effective method for managing postoperative pain in children undergoing Hickman catheter or chemoport insertion, reducing the need for analgesics within 24 h after surgery.


Assuntos
Bloqueio do Plexo Braquial , Cateteres Venosos Centrais , Humanos , Criança , Anestésicos Locais/uso terapêutico , Cateteres Venosos Centrais/efeitos adversos , Ultrassonografia de Intervenção/métodos , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/etiologia , Bloqueio do Plexo Braquial/efeitos adversos , Analgésicos , Analgésicos Opioides
9.
Proc Natl Acad Sci U S A ; 118(19)2021 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-33893178

RESUMO

Capabilities in continuous monitoring of key physiological parameters of disease have never been more important than in the context of the global COVID-19 pandemic. Soft, skin-mounted electronics that incorporate high-bandwidth, miniaturized motion sensors enable digital, wireless measurements of mechanoacoustic (MA) signatures of both core vital signs (heart rate, respiratory rate, and temperature) and underexplored biomarkers (coughing count) with high fidelity and immunity to ambient noises. This paper summarizes an effort that integrates such MA sensors with a cloud data infrastructure and a set of analytics approaches based on digital filtering and convolutional neural networks for monitoring of COVID-19 infections in sick and healthy individuals in the hospital and the home. Unique features are in quantitative measurements of coughing and other vocal events, as indicators of both disease and infectiousness. Systematic imaging studies demonstrate correlations between the time and intensity of coughing, speaking, and laughing and the total droplet production, as an approximate indicator of the probability for disease spread. The sensors, deployed on COVID-19 patients along with healthy controls in both inpatient and home settings, record coughing frequency and intensity continuously, along with a collection of other biometrics. The results indicate a decaying trend of coughing frequency and intensity through the course of disease recovery, but with wide variations across patient populations. The methodology creates opportunities to study patterns in biometrics across individuals and among different demographic groups.


Assuntos
COVID-19/fisiopatologia , Frequência Cardíaca , Taxa Respiratória , Sons Respiratórios , SARS-CoV-2 , Tecnologia sem Fio , Biomarcadores , Humanos , Monitorização Fisiológica
10.
Proc Natl Acad Sci U S A ; 118(43)2021 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-34663725

RESUMO

Early identification of atypical infant movement behaviors consistent with underlying neuromotor pathologies can expedite timely enrollment in therapeutic interventions that exploit inherent neuroplasticity to promote recovery. Traditional neuromotor assessments rely on qualitative evaluations performed by specially trained personnel, mostly available in tertiary medical centers or specialized facilities. Such approaches are high in cost, require geographic proximity to advanced healthcare resources, and yield mostly qualitative insight. This paper introduces a simple, low-cost alternative in the form of a technology customized for quantitatively capturing continuous, full-body kinematics of infants during free living conditions at home or in clinical settings while simultaneously recording essential vital signs data. The system consists of a wireless network of small, flexible inertial sensors placed at strategic locations across the body and operated in a wide-bandwidth and time-synchronized fashion. The data serve as the basis for reconstructing three-dimensional motions in avatar form without the need for video recordings and associated privacy concerns, for remote visual assessments by experts. These quantitative measurements can also be presented in graphical format and analyzed with machine-learning techniques, with potential to automate and systematize traditional motor assessments. Clinical implementations with infants at low and at elevated risks for atypical neuromotor development illustrates application of this system in quantitative and semiquantitative assessments of patterns of gross motor skills, along with body temperature, heart rate, and respiratory rate, from long-term and follow-up measurements over a 3-mo period following birth. The engineering aspects are compatible for scaled deployment, with the potential to improve health outcomes for children worldwide via early, pragmatic detection methods.


Assuntos
Comportamento do Lactente/fisiologia , Monitorização Fisiológica/instrumentação , Movimento/fisiologia , Sinais Vitais/fisiologia , Tecnologia sem Fio/instrumentação , Viés , Criança , Desenho de Equipamento , Frequência Cardíaca , Humanos , Imageamento Tridimensional , Lactente , Miniaturização , Monitorização Fisiológica/estatística & dados numéricos , Taxa Respiratória , Pele , Gravação em Vídeo , Tecnologia sem Fio/estatística & dados numéricos
11.
Eur J Anaesthesiol ; 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38884417

RESUMO

BACKGROUND: The association between the concentration of atmospheric particulate matter on the day of surgery and the occurrence of intra-operative hypoxaemia in children receiving general anaesthesia is unclear. OBJECTIVE: To investigate the association between the exposure to of particulate matter on the day of surgery and the occurrence of intra-operative hypoxaemia, defined as a pulse oximetry oxygen saturation of less than 90% for more than 1 min, in children. DESIGN: Retrospective study. SETTING: Single-centre. PARTICIPANTS: Children aged 18 years or younger who received general anaesthesia between January 2019 and October 2020. INTERVENTION: Information on daily levels of particulate matter with a diameter 10 µm or less and 2.5 µm or less measured within a neighbourhood corresponding to the area defined by the hospital's zip code was obtained from publicly available air-quality data. MAIN OUTCOME MEASURES: The primary outcome was intra-operative hypoxaemia, defined as a pulse oximetry oxygen saturation of less than 90% lasting for more than 1 min, manually verified by anaesthesiologists using vital sign registry data extracted at 2 s intervals. RESULTS: Of the patients finally analysed, 3.85% (489/13 175) experienced intra-operative hypoxaemia. Higher levels of particulate matter 10 µm or less in diameter (≥81 µg m-3, 472/12 900, 3.7%) were associated with an increased occurrence of intra-operative hypoxaemia compared with lower particulate matter concentrations [<81 µg m-3, 17/275, 6.2%; adjusted odds ratio, 1.71; 95% confidence interval (CI), 1.04 to 2.83; P = 0.035]. CONCLUSION: The level of particulate matter on the day of surgery pose a risk of intra-operative hypoxaemia in children receiving general anaesthesia. If the concentrations of particulate matter 10 µm or less in diameter on the day of surgery are high, children receiving general anaesthesia should be managed with increased caution.

12.
Eur J Anaesthesiol ; 41(7): 522-529, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38517311

RESUMO

BACKGROUND: The effectiveness of head mounted real-time ultrasound displays (hereafter referred to as 'smart glasses') in improving hand-eye coordination in less experienced individuals, such as trainees in anaesthesia, is unclear. OBJECTIVES: To compare the first-attempt success rate of smart glasses-assisted ultrasound-guided paediatric radial artery catheterisation with conventional ultrasound guided catheterisation performed by anaesthesiology trainees. DESIGN: Prospective randomised controlled trial. SETTINGS: Tertiary university hospital from September 2021 to February 2023. PATIENTS: One hundred and twenty-two paediatric patients (age <7 years, weight ≥3 kg) who required radial artery cannulation during general anaesthesia. INTERVENTIONS: The participants were randomly assigned to either the ultrasound screen group (control) or the smart glasses group prior to radial artery catheterisation. MAIN OUTCOME MEASURES: The primary outcome was the first attempt success rate. Secondary outcomes included the number of attempts, use of transfixion technique, overall complication rate, and clinical anaesthesiology (CA) year of the operators. RESULTS: A total of 119 paediatric patients were included in the analysis. The smart glasses group exhibited higher first-attempt success rate than did the control group (89.8% [53/59] vs. 71.7% [43/60]; P  = 0.023; odds ratio (OR) 3.49; (95% confidence interval (CI) 1.27-9.6). The overall number of attempts [median, 1; interquartile range (IQR), 1-1; range, 1-3 vs. median, 1; IQR, 1-2; range, 1-4; P   =  0.006], use of transfixion technique (12/59 [20.3%] vs. 28/60 [46.7%]; P  = 0.002), and overall complication rate (6.8% [4/59] vs. 30.0% [18/60]; P  = 0.002) were lower in the smart glasses group than in the control group. However, among paediatric anaesthesiology fellows (CA 5 years), the first- (89.3% [25/28] vs. 80.8% [21/26]; P  = 0.619) and second-attempt success rates (96.4% [27/28] vs. 80.8% [21/26]; P  = 0.163) did not differ between the two groups. CONCLUSIONS: Smart glasses-assisted ultrasound guided radial artery catheterisation improved the first attempt success rate among anaesthesiology trainees, reducing the number of attempts and overall complication rates in small paediatric patients. Smart glasses were more effective for anaesthesia residents (CA 2-4 years) but were not effective for paediatric anaesthesiology fellows (CA 5 years). TRIAL REGISTRATION: ClinicalTrials.gov (NCT05030649) ( https://classic.clinicaltrials.gov/ct2/show/NCT05030649 ).


Assuntos
Anestesiologia , Cateterismo Periférico , Artéria Radial , Ultrassonografia de Intervenção , Humanos , Artéria Radial/diagnóstico por imagem , Feminino , Masculino , Estudos Prospectivos , Ultrassonografia de Intervenção/métodos , Cateterismo Periférico/métodos , Anestesiologia/educação , Pré-Escolar , Criança , Lactente , Óculos Inteligentes , Anestesia Geral , Competência Clínica , Cabeça
13.
Eur J Anaesthesiol ; 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38832435

RESUMO

BACKGROUND: The potential benefits of Analgesia Nociception Index guided intra-operative analgesia on intra-operative opioid consumption remains to be demonstrated in paediatric anaesthesia. OBJECTIVES: This study aimed to explore the effects of Analgesia Nociception Index guided analgesia on sufentanil consumption during anaesthesia and postoperative pain scores in paediatric patients with moyamoya disease. DESIGN: A prospective randomised controlled study. SETTING: Seoul National University Children's Hospital, Seoul, Republic of Korea. PATIENTS: A total of 40 children scheduled for encephaloduroarteriosynangiosis. MAIN OUTCOME MEASURES: The primary outcome was total intra-operative sufentanil consumption, and the secondary outcomes included postoperative pain scores and incidence of opioid-related adverse events. RESULTS: The Analgesia Nociception Index group showed lower intra-operative sufentanil consumption (in µg kg-1 h-1) compared with the Standard group (0.30 ±â€Š0.12 and 0.39 ±â€Š0.17, respectively; mean difference, -0.09; 95% confidence interval, -0.19 to 0.00; P = 0.049). Postoperatively, compared with the Standard group, the Analgesia Nociception Index group reported lower median pain scores at 18 and 24 h and maximum pain within 24 h (1 [0 to 2] vs. 3 [2 to 5]; P = 0.004, 1 [0 to 2] vs. 3 [1 to 4]; P = 0.041, and 4 [3 to 5] vs. 5 [4 to 7]; P = 0.045, respectively), with fewer patients experiencing nausea (3 [15%] vs. 10 [50%], P = 0.043). CONCLUSION: The Analgesia Nociception Index guided analgesic protocol can reduce intra-operative sufentanil consumption and postoperative pain within 24 h with fewer nausea symptoms in paediatric patients with moyamoya disease who undergo encephaloduroarteriosynangiosis. TRIAL REGISTRATION NUMBER: NCT05672212 (registered at clinicaltrials, principal investigator: K.E.H., registration date: 2 January 2023).

14.
Cardiol Young ; 34(4): 914-918, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37981864

RESUMO

BACKGROUNDS AND OBJECTIVES: The "Fast track" protocol is an early extubation strategy to reduce ventilator-associated complications and induce early recovery after open-heart surgery. This study compared clinical outcomes between operating room extubation and ICU extubation after open-heart surgery in patients with CHD. METHODS: We retrospectively reviewed 215 patients who underwent open-heart surgery for CHDs under the scheduled "Fast track" protocol between September 2016 and April 2022. The clinical endpoints were post-operative complications, including bleeding, respiratory and neurological complications, and hospital/ICU stays. RESULTS: The patients were divided into operating room extubation (group O, n = 124) and ICU extubation (group I, n=91) groups. The most frequently performed procedures were patch closures of the atrial septal (107/215, 49.8%) and ventricular septal (89/215, 41.4%) defects. There were no significant differences in major post-operative complications or ICU and hospital stay duration between the two groups; however, patients in group I showed longer mechanical ventilatory support (0.0 min vs. 59.0 min (interquartile range: 17.0-169.0), p < 0.001). Patients in Group O showed higher initial lactate levels (3.2 ± 1.7 mg/dL versus 2.5 ± 2.0 mg/dL, p = 0.007) and more frequently used additional sedatives and opioid analgesics (33.1% versus 19.8%, p = 0.031). CONCLUSIONS: Extubation in the operating room was not beneficial for patients during post-operative ICU or hospital stay. Early extubation in the ICU resulted in more stable hemodynamics in the immediate post-operative period and required less use of sedatives and analgesics.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Salas Cirúrgicas , Humanos , Estudos Retrospectivos , Extubação/métodos , Hipnóticos e Sedativos , Unidades de Terapia Intensiva , Tempo de Internação
15.
J Clin Monit Comput ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38561555

RESUMO

PURPOSE: To determine the precise induction dose, an objective assessment of individual propofol sensitivity is necessary. This study aimed to investigate whether preinduction electroencephalogram (EEG) data are useful in determining the optimal propofol dose for the induction of general anesthesia in healthy adult patients. METHODS: Seventy healthy adult patients underwent total intravenous anesthesia (TIVA), and the effect-site target concentration of propofol was observed to measure each individual's propofol requirements for loss of responsiveness. We analyzed preinduction EEG data to assess its relationship with propofol requirements and conducted multiple regression analyses considering various patient-related factors. RESULTS: Patients with higher relative delta power (ρ = 0.47, p < 0.01) and higher absolute delta power (ρ = 0.34, p = 0.01) required a greater amount of propofol for anesthesia induction. In contrast, patients with higher relative beta power (ρ = -0.33, p < 0.01) required less propofol to achieve unresponsiveness. Multiple regression analysis revealed an independent association between relative delta power and propofol requirements. CONCLUSION: Preinduction EEG, particularly relative delta power, is associated with propofol requirements during the induction of general anesthesia. The utilization of preinduction EEG data may improve the precision of induction dose selection for individuals.

16.
Anesth Analg ; 136(6): 1067-1074, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36727868

RESUMO

BACKGROUND: Perioperative respiratory adverse events are common in children. We aimed to evaluate the effect of the transdermal ß-2 agonist, tulobuterol, compared with that of placebo on the incidence of perioperative respiratory adverse events in pediatric patients undergoing tonsillectomy. METHODS: In this triple-blinded (patient, anesthesia provider, and outcome assessor) randomized controlled trial, 188 patients were randomly allocated to receive tulobuterol or a placebo. The tulobuterol groups received a tulobuterol patch (1 mg) masked with a bandage, whereas the placebo only received the bandage. The assigned bandage was applied to the patients 8 to 10 hours before the surgery. The primary outcome was the occurrence of any perioperative respiratory adverse events: oxygen desaturation <95%, airway obstruction, laryngospasm, bronchospasm, severe coughing, or stridor. The outcomes were evaluated using the average relative effect test, which estimates the effect of individual components of a composite outcome and then averages effects across components. RESULTS: A total of 88 and 94 patients who received tulobuterol and placebo, respectively, were analyzed. The incidence of any perioperative respiratory adverse event was lower with tulobuterol (n = 13/88; 14.7%) than that with the placebo (n = 40/94; 42.5%), with an estimated average relative risk (95% confidence interval) across components of 0.35 (0.20-0.60; P < .001). The symptoms of airway obstruction were lower with tulobuterol (n = 8/88; 9.0%) than that with the placebo (n = 32/94; 34.0%), with relative risk (95% CI) of 0.31 (0.17-0.56; P < .001). The occurrence of severe coughing was lower with tulobuterol (n = 1/88; 1.1%) than that with the placebo (n = 8/94; 8.5%), with relative risk (95% CI) of 0.15 (0.03-0.68; P = .014). CONCLUSIONS: In preschool children undergoing tonsillectomy, the preoperative application of a tulobuterol patch could decrease the occurrence of perioperative respiratory adverse events. Further studies are needed to elucidate the effect of the tulobuterol patch in a broad spectrum of pediatric anesthesia.


Assuntos
Obstrução das Vias Respiratórias , Tonsilectomia , Pré-Escolar , Humanos , Criança , Tonsilectomia/efeitos adversos , Terbutalina/efeitos adversos , Tosse/induzido quimicamente , Tosse/epidemiologia , Tosse/prevenção & controle
17.
BMC Anesthesiol ; 23(1): 339, 2023 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-37814224

RESUMO

BACKGROUND: This study investigated the effects of intraoperative goal-directed hemodynamic therapy (GDHT) on postoperative outcomes in patients undergoing open radical cystectomy. METHODS: This prospective, single-center, randomized controlled trial included 82 patients scheduled for open radical cystectomy between September 2018 and November 2021. The GDHT group (n = 39) received the stroke volume index- and cardiac index-based hemodynamic management using advanced hemodynamic monitoring, while the control group (n = 36) received the standard care under the discretion of attending anesthesiologists during surgery. The primary outcome was the incidence of a composite of in-hospital postoperative complications during hospital stays. RESULTS: A total of 75 patients were included in the final analysis. There was no significant difference in the incidence of in-hospital postoperative complications (28/39 [71.8%] vs. 30/36 [83.3%], risk difference [95% CI], -0.12 [-0.30 to 0.07], P = 0.359) between the groups. The amounts of intraoperative fluid administered were similar between the groups (2700 [2175-3250] vs. 2900 [1950-3700] ml, median difference [95% CI] -200 [-875 to 825], P = 0.714). The secondary outcomes, including the incidence of seven major postoperative complications, duration of hospital stay, duration of intensive care unit stay, and grade of complications, were comparable between the two groups. Trends in postoperative estimated glomerular filtration rate, serum creatinine, and C-reactive protein did not differ significantly between the two groups. CONCLUSIONS: Intraoperative GDHT did not reduce the incidence of postoperative in-hospital complications during the hospital stay in patients who underwent open radical cystectomy. TRIAL REGISTRATION: This study was registered at http://www. CLINICALTRIALS: gov (Registration number: NCT03505112; date of registration: 23/04/2018).


Assuntos
Cistectomia , Objetivos , Humanos , Estudos Prospectivos , Hemodinâmica , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Hidratação/efeitos adversos
18.
Can J Anaesth ; 70(12): 1957-1969, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37919629

RESUMO

PURPOSE: Increased portal venous flow pulsatility is associated with major complications after adult cardiac surgery. Nevertheless, no data are available for pediatric patients with congenital heart disease. We hypothesized that Doppler parameters including portal flow pulsatility could be associated with postoperative outcomes in children undergoing various cardiac surgeries. METHODS: We conducted a prospective observational cohort study in children undergoing congenital cardiac surgery. We obtained postoperative portal, splenic, and hepatic venous Doppler data and perioperative clinical data including major postoperative complications. Portal and splenic venous flow pulsatility were calculated. We evaluated the association between venous Doppler parameters and adverse outcomes. The primary objective was to determine whether postoperative portal flow pulsatility could indicate major complications following congenital heart surgery. RESULTS: In this study, we enrolled 389 children, 74 of whom experienced major postoperative complications. The mean (standard deviation) portal pulsatility (44 [30]% vs 25 [14]%; 95% confidence interval [CI] for mean difference, 12 to 26; P < 0.001] and splenic pulsatility indices (41 [30]% vs 26 [16]%; 95% CI, 7 to 23; P < 0.001) were significantly higher in children with postoperative complications than in those without complications. The portal pulsatility index was able to help identify postoperative complications in biventricular patients and univentricular patients receiving bidirectional cavopulmonary shunt whereas it did not in other univentricular patients. An increased postoperative portal pulsatility index was significantly associated with major complications after pediatric cardiac surgery (odds ratio, 1.40; 95% CI, 1.29 to 1.91; P < 0.001). CONCLUSIONS: Higher portal venous pulsatility is associated with major postoperative complications in children undergoing cardiac surgery. Nevertheless, more data are needed to conclude the efficacy of portal venous pulsatility in patients with univentricular physiology. STUDY REGISTRATION: ClinicalTrials.gov (NCT03990779); registered 19 June 2019.


RéSUMé: OBJECTIF: L'augmentation de la pulsatilité du flux de la veine porte est associée à des complications majeures après une chirurgie cardiaque chez l'adulte. Néanmoins, aucune donnée n'est disponible pour la patientèle pédiatrique atteinte de cardiopathie congénitale. Nous avons émis l'hypothèse que les paramètres Doppler, y compris la pulsatilité du flux de la veine porte, pourraient être associés aux devenirs postopératoires des enfants bénéficiant de diverses chirurgies cardiaques. MéTHODE: Nous avons réalisé une étude de cohorte observationnelle prospective portant sur des enfants bénéficiant d'une chirurgie cardiaque congénitale. Nous avons obtenu des données Doppler des veines porte, spléniques et hépatiques postopératoires ainsi que des données cliniques périopératoires, y compris les complications postopératoires majeures. La pulsatilité du flux des veines porte et spléniques a été calculée. Nous avons évalué l'association entre les paramètres Doppler veineux et les issues indésirables. L'objectif principal était de déterminer si la pulsatilité du flux postopératoire de la veine porte pouvait constituer un indicateur des complications majeures après une chirurgie cardiaque congénitale. RéSULTATS: Dans cette étude, nous avons recruté 389 enfants, dont 74 ont présenté des complications postopératoires majeures. La pulsatilité moyenne de la veine porte (écart type) (44 [30] % vs 25 [14] %; intervalle de confiance [IC] à 95 % pour la différence moyenne, 12 à 26; P < 0,001] et les indices de pulsatilité splénique (41 [30] % vs 26 [16] %; IC 95 %, 7 à 23; P < 0,001) étaient significativement plus élevés chez les enfants présentant des complications postopératoires que chez les enfants sans complications. L'indice de pulsatilité de la veine porte a permis d'identifier les complications postopératoires chez les patient·es biventriculaires et les patient·es univentriculaires recevant une anastomose cavo-pulmonaire bidirectionnelle (procédure de Glenn), alors que ce n'était pas le cas chez les autres patient·es univentriculaires. Une augmentation postopératoire de l'indice de pulsatilité de la veine porte était significativement associée à des complications majeures après une chirurgie cardiaque pédiatrique (rapport de cotes, 1,40; IC 95 %, 1,29 à 1,91; P < 0,001). CONCLUSION: Une pulsatilité plus élevée de la veine porte est associée à des complications postopératoires majeures chez les enfants bénéficiant d'une chirurgie cardiaque. Néanmoins, davantage de données sont nécessaires pour conclure à l'efficacité de la pulsatilité de la veine porte chez les patient·es présentant une physiologie univentriculaire. ENREGISTREMENT DE L'éTUDE: ClinicalTrials.gov (NCT03990779); enregistrée le 19 juin 2019.


Assuntos
Cardiopatias Congênitas , Veia Porta , Criança , Humanos , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/complicações , Veia Porta/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Ultrassonografia Doppler
19.
J Cardiothorac Vasc Anesth ; 37(8): 1456-1468, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37183119

RESUMO

OBJECTIVE: Little is known about changes in portal, splenic, and hepatic vein flow patterns in children undergoing congenital heart surgery. This study aimed to determine the characteristics of portal, splenic, and hepatic vein flow patterns using ultrasonography in children undergoing cardiac surgery. DESIGN: Single-center, prospective observational study. SETTING: Tertiary children's hospital, operating room. PARTICIPANTS: Children undergoing cardiac surgery. MEASUREMENT AND MAIN RESULTS: The authors obtained ultrasound data from the heart, inferior vena cava, portal, splenic, and hepatic veins before and after surgeries. In the biventricular group, which included children with atrial and ventricular septal defects and pulmonary stenosis (n = 246), the portal pulsatility index decreased from 38.7% to 25.6% (p < 0.001) after surgery. The preoperative portal pulsatility index was significantly higher in patients with pulmonary hypertension (43.3% v 27.4%; p < 0.001). In the single-ventricle group (n = 77), maximum portal vein flow velocities of Fontan patients were significantly lower (13.5 cm/s) compared with that of patients with modified Blalock-Taussig shunt (19.7 cm/s; p = 0.035) or bidirectional cavopulmonary shunt (23.1 cm/s; p < 0.001). The cardiac index was inversely correlated with the portal pulsatility index in the bidirectional cavopulmonary shunt and Fontan circulation. (ß = -5.693, r2 = 0.473; p = 0.001) The portal pulsatility index was correlated with splenic venous pulsatility and hepatic venous atrial reverse flow velocity in biventricular and single-ventricle groups. CONCLUSIONS: The characteristics of venous Doppler patterns in the portal, splenic, and hepatic veins differed according to congenital heart disease. Further studies are required to determine the association between splanchnic venous Doppler findings and clinical outcomes in this population.


Assuntos
Fibrilação Atrial , Técnica de Fontan , Cardiopatias Congênitas , Humanos , Criança , Veias Hepáticas/diagnóstico por imagem , Veia Cava Inferior/cirurgia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Velocidade do Fluxo Sanguíneo
20.
Paediatr Anaesth ; 33(7): 562-570, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37061868

RESUMO

BACKGROUND: The light reflex, which reflects central nervous system dysfunction, can also be affected by anesthetic agents. AIMS: We evaluated whether these effects differed according to the anesthetic agent in pediatric patients. METHODS: Twenty children aged 3-12 years who were scheduled to undergo elective surgery under general anesthesia were randomly allocated to propofol and sevoflurane groups and underwent pupillometric assessments at five points during anesthesia: T1, after confirming loss of consciousness; T2, after endotracheal intubation; T3, at the time of skin incision; T4, 1 h after skin incision; and T5, before endotracheal extubation. The primary outcome was the Neurological Pupil index at T4, and the secondary outcomes were other pupillometric parameters, including pupil diameter, percentage of change in pupil diameter, dilation velocity, and constriction velocity. RESULTS: At T4, the Neurological Pupil index was significantly lower in the sevoflurane group (median difference, 0.30; 95% CI, 0.00 to 0.70; p = .036). Furthermore, the Neurological Pupil index at all time points was lower in the sevoflurane group. The time-and-group interaction effects on constriction velocity and dilation velocity were significantly different [F(1, 4) = 16.68, p = .002; F(1, 4) = 14.78, p = .008, respectively] but were not different on the Neurological Pupil index, pupil diameter, and percentage of change in pupil diameter. No intergroup differences were observed in the baseline characteristics, the flow rate of remifentanil at each time point, and total infused remifentanil. CONCLUSION: The Neurological Pupil index value in pediatric patients under general anesthesia is affected by the anesthetic agent used; this factor requires consideration in evaluations of the Neurological Pupil index during general anesthesia.


Assuntos
Anestésicos Intravenosos , Propofol , Humanos , Criança , Anestésicos Intravenosos/farmacologia , Remifentanil , Sevoflurano , Propofol/farmacologia , Anestesia Geral , Anestesia Intravenosa
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa