1.
Arch Orthop Trauma Surg ; 144(8): 3369-3378, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39126454

RESUMO

INTRODUCTION: Cementless fixation has become increasingly popular in hip arthroplasty due to its shorter operation time, easier technique, biologic fixation, and avoidance of bone cement implantation syndrome compared to cemented fixation. However, intraoperative periprosthetic femoral fracture (IOPFx) is a disconcerting complication during cementless hip arthroplasty. Our purpose was to identify the features of cementless stem that increase the risk of IOPFx during primary hip arthroplasty. MATERIALS AND METHODS: We retrospectively reviewed all 4806 hip arthroplasties that was performed in a single institution from May 2003 to December 2020. Age at the index arthroplasty, sex, body mass index, physical status, ambulatory function, side of the operation, operational history, cause of the index arthroplasty, type of arthroplasty, surgical approach, surgeon, implant information, and events during the operation were investigated. The shoulder geometry and length of stem were also reviewed. The event of interest was narrowed down to IOPFx among various records of intraoperative events. RESULTS: We found IOPFx of 2.6% among all the hips operated with cementless stem. In the multivariable analysis, female (OR = 1.52), childhood hip disease (OR = 2.30), stove-pipe femur (OR = 2.43), combined approach (OR = 2.60), and standard length of stem (OR = 1.59) were found to be significant risk factors of IOPFx. CONCLUSIONS: In conclusion, a stem with a standard length is significantly associated with risk of IOPFx compared to a shortened stem. These findings highlight the importance of careful consideration in terms of the risk of IOPFx when standard length cementless stem is chosen.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Artroplastia de Quadril/instrumentação , Feminino , Masculino , Estudos Retrospectivos , Pessoa de Meia-Idade , Prótese de Quadril/efeitos adversos , Idoso , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/etiologia , Fatores de Risco , Complicações Intraoperatórias/etiologia , Fraturas Periprotéticas/etiologia , Desenho de Prótese , Adulto , Idoso de 80 Anos ou mais
2.
Clin Lab ; 69(5)2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37145083

RESUMO

BACKGROUND: One of the most dangerous side effects of joint replacement for the hip, knee, shoulder, and elbow is prosthesis joint infection (PJI). Polymerase chain reaction (PCR) has been considered a promising method for PJI diagnosis due to its short diagnostic time and high sensitivity. Although several PCR methods such as multiplex PCR and broad-range PCR are useful diagnostic methods for detecting microorganisms causing PJI, values of different PCR methods for the diagnosis of PJI remain unclear. Thus, the objective of this study was to perform a meta-analysis of different PCR methods in the diagnosis of PJI to determine their diagnostic characteristics including sensitivity and specificity. METHODS: The following data were extracted: PCR method, number of patients, sample site and type, diagnosis standard, true positive, false positive, false negative, and true negative. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were calculated. Meta-regression analysis was conducted to assess heterogeneity. Subgroup analysis was also performed to assess effects of several variables on meta-analysis results. RESULTS: The current study showed that pooled sensitivity and pooled specificity were 0.70 (95% CI: 0.67 - 0.73) and 0.94 (95% CI: 0.92 - 0.95), respectively. Results of subgroup analysis indicated that sequencing method showed the lowest sensitivity (0.63, 95% CI: 0.59 - 0.67). However, after excluding studies using tissue samples directly, sequencing method showed higher sensitivity (0.83, 95% CI: 0.73 - 0.90) than other PCR methods (0.74, 95% CI: 0.69 - 0.78). CONCLUSIONS: The main significance of this study was that we attempted to classify accuracies of several PCR methods and found that sequencing with a reliable sampling method could be used as an early screening strategy for PJI. Further comparisons for PCR technologies are needed to evaluate their cost effectiveness and diagnostic procedures, not just diagnostic values, to discover the optimal one for PJI diagnosis.


Assuntos
Artrite Infecciosa , Próteses e Implantes , Humanos , Sensibilidade e Especificidade , Artrite Infecciosa/diagnóstico , Reação em Cadeia da Polimerase Multiplex , Razão de Chances , Líquido Sinovial
3.
BMC Musculoskelet Disord ; 24(1): 465, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37280558

RESUMO

BACKGROUND: This study aimed to analyze the differences in the stability of fractures, stress distribution around the distal-most screw according to the length of the plate and the trajectory of the bolt in Pauwels type III femoral neck fracture using the femoral neck system (FNS). METHODS: Finite element models of Pauwels type III femoral neck fractures were established with surgical variations in the trajectory of the bolt (central, inferior, valgus, and varus) and length of the lateral plate (1- and 2-hole plate). The models were subsequently subjected to normal walking and stair-climbing loads. RESULTS: The screw-holding cortical bone in subtrochanter in the model with a 2-hole plate and the bolt in the inferior trajectory and the models with 1-hole or 2-hole plate and the bolt in valgus trajectory had shown greater maximum principal strain than the models with central or varus trajectories. The gap and sliding distance on the fracture surface were larger with inferior or varus trajectories of the bolt and smaller with the valgus trajectory of the bolt under both loads, compared to those of the central trajectory. CONCLUSION: For the fixation of Pauwels type III femoral neck fracture, the trajectory of the FNS bolt and the length of the plate affect the mechanical stability of the fracture and the strain of cortical bone around the distal-most screw. The surgical target should stay on the central trajectory of the bolt and the 2-hole plate's mechanical benefits did not exceed the risk.


Assuntos
Fraturas do Colo Femoral , Fraturas do Quadril , Humanos , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/cirurgia , Análise de Elementos Finitos , Fixação Interna de Fraturas/efeitos adversos , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/etiologia , Fraturas do Colo Femoral/cirurgia , Fenômenos Biomecânicos
4.
BMC Musculoskelet Disord ; 24(1): 506, 2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37344858

RESUMO

BACKGROUND: Femoral neck fractures are a common injury in older adults and their management presents a significant challenge for orthopedic surgeons. The Femoral Neck System (FNS) was recently introduced for the fixation of femur neck fractures. Although neck shortening was reduced with the FNS, the complication rates were not reduced. Thus, improvements to enhance fixation stability should be made for the FNS. We hypothesized that (1) the pre-sliding technique and (2) the use of longer anti-rotation screw would increase fracture stability. This study aimed to determine the change in fracture stability using the pre-sliding technique and long anti-rotation screw in the FNS for fixation of Pauwels type III femoral neck fractures. METHODS: Finite element models of Pauwels type III femoral neck fracture fixed with pre-sliding FNS and 5-mm longer anti-rotation screw were established. The models were subjected to normal walking load. The material properties of the elements belonging to the bone were mapped by assigning the formulation with the computed tomography Hounsfield unit. RESULTS: Pauwels type III femoral neck fractures fixed with pre-slided FNS showed better fracture stability, decreasing fracture gap and sliding by 14% and 12%, respectively, under normal walking load. No element of cortical bone in any of the models had an absolute value of principal strain that exceeded 1%. The peak von Mises stress (VMS) of the implants ranged from 260 to 289 MPa, and the highest peak VMS value was 50% lower than the yield strength of the titanium alloy (800 MPa). The longer anti-rotation screw did not affect fracture stability. CONCLUSIONS: The pre-sliding technique using the FNS showed higher fracture stability than the standard fixation technique for a Pauwels type III femoral neck fracture. The longer anti-rotation screw did not contribute significantly to fixation stability. As this finite element analysis considered the inhomogeneous mechanical property of the bone, it offered equivalent mechanical conditions to investigate the components of interest.


Assuntos
Fraturas do Colo Femoral , Colo do Fêmur , Fixação Interna de Fraturas , Idoso , Humanos , Fenômenos Biomecânicos , Parafusos Ósseos , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/cirurgia , Análise de Elementos Finitos , Fixação Interna de Fraturas/métodos
5.
Medicina (Kaunas) ; 59(12)2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38138229

RESUMO

Background and Objectives: Hip fractures are commonly found in elderly patients, and often result in chronic pain and decreased physical function, as well as worsening of overall health. It is known that early surgical intervention during the acute phase and rehabilitation are important for improving clinical outcomes for these patients. However, the importance of management for improving the quality of life of these patients is becoming more emphasized. Studies on changes in sleep patterns after hip fractures are rare overseas. Therefore, the aim of this study is to investigate the prevalence of sleep disturbance in patients with hip fractures and to analyze the changes in sleep disturbance after surgery by comparing the preoperative and postoperative results. Materials and Methods: During the period from August 2022 to January 2023, patients who underwent surgical treatment for hip fractures and were recruited into the REAL Hip Cohort were selected as research subjects. The sleep survey was conducted using the Pittsburgh Sleep Quality Index (PSQI). The PSQI is composed of 18 questions, each divided into areas of sleep quality, sleep latency, duration, efficiency, disturbance, use of medication, and daytime dysfunction. Each area is scored 0-3 points and the total is 0-21. A score greater than five indicates sleep disorder. The PSQI was surveyed during hospitalization and three months after surgery for post-fracture sleep status. To analyze changes before and after the fracture, paired T-tests and chi-square tests were performed. Results: From August 2022 to January 2023, a total of 40 patients who were recruited into the REAL Hip Cohort responded to the PSQI survey. The average age was 77.4 years and 36 were female. Sleep quality worsened from 0.75 ± 1.0 before surgery to 1.4 ± 1.0 three months after surgery (p = 0.019), and sleep efficiency also worsened from 0.4 ± 0.6 to 1.4 ± 1.0 (p < 0.001). The PSQI increased from an average of 5.2 ± 2.8 before surgery to 8.2 ± 4.2 three months after surgery (p = 0.007), and the number of patients who could be diagnosed with sleep disorders also increased from 12 (40%) to 24 (60%) (p = 0.030). Conclusions: A decline in overall sleep status was observed in patients in a survey on sleep patterns three months after hip fracture. Additional management is needed to improve their sleep patterns.


Assuntos
Fraturas do Quadril , Transtornos do Sono-Vigília , Humanos , Feminino , Idoso , Masculino , Qualidade do Sono , Qualidade de Vida , Inteligência Artificial , Fraturas do Quadril/complicações , Fraturas do Quadril/epidemiologia , Fraturas do Quadril/cirurgia , Sono , Transtornos do Sono-Vigília/epidemiologia , Transtornos do Sono-Vigília/etiologia
6.
J Orthop Sci ; 27(5): 1089-1095, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34391618

RESUMO

BACKGROUND: The purpose of this study was to analyze the association between the preoperative and postoperative use of antidepressant and benzodiazepine and all-cause mortality in elderly hip fracture patients. METHODS: Patients who underwent surgical treatment for hip fracture over 65 years old were classified into Past-user, Current-user, and Non-users for each period according to use history for antidepressants or benzodiazepines. And, for the subgroup analysis, patients were classified by presence of past history for psychiatric medication. A multivariable-adjusted Cox proportional hazards model was used to investigate the effects of antidepressants and benzodiazepines on all-cause mortality. RESULTS: A total of 15,576 patients were included in this study. Past users of antidepressants and benzodiazepines were 5699 (36.59%) patients and 11,319 (72.67%) patients, respectively. Current users of antidepressants and benzodiazepines were 2888 (18.54%) patients and 6287 (40.36%) patients, respectively. There were no statistically significant differences in the adjusted hazard for death compared to the non-users for both the past and the current users (p > 0.05). In the subgroup analysis, there were 12,502 once-users and 3074 never-users according to psychiatric medication. Current uses of antidepressants and benzodiazepine in the once-user did not increase adjusted hazard for death compared to the non-users (p>0.05). However, current uses of antidepressants by never-users increased the adjusted hazard for death compared to the non-user (adjusted hazard ratio, 1.31; 95% CI, 1.08-1.59; p = 0.007). CONCLUSIONS: No association was observed between the uses of antidepressants and benzodiazepines after hip fracture and mortality risk in elderly patients who received psychiatric medication before hip fracture. However, the use of these medications was associated with increased all-cause mortality risk in patients who had no history of psychiatric medication before hip fracture. LEVEL OF EVIDENCE: III, retrospective cohort study.


Assuntos
Benzodiazepinas , Fraturas do Quadril , Idoso , Antidepressivos/uso terapêutico , Benzodiazepinas/uso terapêutico , Estudos de Coortes , Fraturas do Quadril/tratamento farmacológico , Fraturas do Quadril/cirurgia , Humanos , República da Coreia/epidemiologia , Estudos Retrospectivos
7.
BMC Musculoskelet Disord ; 22(1): 621, 2021 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-34256741

RESUMO

BACKGROUND: The depth of bolt in Femoral neck system (FNS, DePuy Synthes, Oberdorf, Switzerland) is difficult to finely control as the length of the bolt is in units of 5 mm. Thus, this study introduces a method to control the depth of FNS bolt in analogue scale in patients with femoral neck fracture. METHODS: By the technique of control of reaming and retraction of bolt, the tip of implant could be positioned close to subchondral bone without harming it. The position of implant tip in four cases in which the introduced technique was applied was compared to that of eight cases where the standard technique was performed. RESULTS: The average tip-apex distance measured in the cases that underwent surgery using the suggested technique in this study was statistically significantly shorter than that measured in the cases that underwent surgery under manufacturer guidelines. CONCLUSION: Even though the bolt of FNS is manufactured in the unit of 5 mm, the technique proposed in this study helps surgeons to adjust the depth of bolt for the fixation of femoral neck fracture using FNS.


Assuntos
Fraturas do Fêmur , Fraturas do Colo Femoral , Parafusos Ósseos , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/cirurgia , Colo do Fêmur , Fixação Interna de Fraturas , Humanos , Suíça
8.
J Arthroplasty ; 35(10): 2911-2918, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32473769

RESUMO

BACKGROUND: Total hip arthroplasty (THA) of patients with a proximal femoral deformity is technically demanding. This deformity poses the risk of femoral fracture or perforation; stem malposition; and failed stem fixation. To insert a femoral stem in neutral position with a good fit, we removed the greater trochanter in case of a varus deformity, and the lesser trochanter in case of valgus deformity, while performing THA. We aimed to evaluate stem position, implant stability, clinical results, and radiological changes after THAs using this technique. METHODS: Fifteen patients (17 hips; 11 varus hips and 6 valgus hips) underwent cementless THA using the trochanteric osteotomy technique in one institution. We evaluated procedure-specific complications: intraoperative femoral fracture, stem malposition, weakness of the abductor power and limp. Modified Harris Hip Score, radiological changes, and the stability of stems were assessed at a mean of 7.1 years of follow-up (range 2.0-15.5). RESULTS: Femoral fracture occurred during the insertion of the stem in 4 hips. All stems were aligned in neutral position. At the latest follow-up, the mean power of the abductor was 4.3 (range 3-5). Eleven patients had slight limp and 4 patients had moderate limp. All stems had bone-ingrown stability and no stem was revised. The mean modified Harris Hip Score improved from 50 points at the preoperative evaluation to 81 points at the final follow-up. CONCLUSION: The trochanteric excision enabled neutral insertion of cementless stem in patients with varus/valgus deformity of the proximal femur, and THA using this technique rendered favorable results.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Seguimentos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Osteotomia , Resultado do Tratamento
9.
J Orthop Sci ; 25(1): 152-155, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30851995

RESUMO

BACKGROUND: Basicervical hip fractures are relatively rare with greater biomechanical instability compared to the other types of hip fractures. Several studies have reported ambivalent surgical outcomes of basicervical hip fractures. The purpose of this multicenter study was to analyze surgical outcomes of basicervical hip fractures according to the fixation type of proximal femur and lag screw type. METHODS: Among 3220 hip fractures, 145 were classified as basicervical hip fractures. Of those, 106 patients treated with osteosynthesis were included to analyze the surgical complications according to fixation type of proximal femur: sliding hip screw(SHS) and cephalomedullary nail (CMN) groups. Surgical complications including the excessive displacement of fracture and the occurrence of reoperation were evaluated at the final follow up. We further evaluated surgical complications according to lag screw type with subgroup analysis in CMN group: single screw type, blade type and two integrated screw type. RESULTS: Ten patients (9.4%) sustained surgical complications (5 excessive displacements and 5 reoperations). For fixation type of proximal femur, SHS group showed higher tendency of excessive displacement despite no statistical difference between the two groups (p = 0.060). For lag screw type with subgroup analysis in CMN group, single screw type showed statistically high rates of reoperation compared to the other types of lag screw (p = 0.022). CONCLUSION: Basicervical hip fractures treated with osteosynthesis resulted to high rates of surgical complications in this study. However, they could be drastically reduced if CMN with blade type or two integrated screw type were used in the osteosynthesis of basicervical hip fractures.


Assuntos
Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Fraturas do Quadril/cirurgia , Reoperação/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
11.
Arch Orthop Trauma Surg ; 139(11): 1579-1586, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31278509

RESUMO

INTRODUCTION: When locking intramedullary nails, inserting the distal interlocking screw accurately and quickly with less radiation exposure is very important. The purpose of this randomized control study was to compare radiation exposure and accuracy of distal locking screws between free-hand fluoroscopic guidance and the use of a distal targeting system (DTS). MATERIALS AND METHODS: Inclusion criteria of this study were patients older than 60 years who need an intramedullary nailing due to unstable intertrochanteric and subtrochanteric fracture. The primary outcome was the attempt numbers of image intensifier during the insertion of distal locking screws. Secondary outcomes were operative time and angles between distal locking screws and nail. RESULTS: A total of 36 patients participated in the study. Eighteen patients using free-hand fluoroscopic guidance were assigned to Group I while 18 patients using DTS were assigned to Group II. The number of attempts of image intensifier during distal screw insertion (57.3 ± 31.42 vs. 11.5 ± 7.41, p < 0.001), ratio of attempt number for distal screws to the total attempts (0.33 ± 0.21 vs. 0.12 ± 0.08, p = 0.001), the number of hand exposure to image intensifier directly (75.0 ± 29.55 vs. 13.5 ± 19.07, p < 0.001), and the time of radiation exposure during distal screws insertion (42.57 ± 2.42 s vs. 12.72 ± 8.10 s, p < 0.001) were significantly lower in Group II compared to those in Group I. And, operation time (96.3 min ± 18.94 vs. 76.1 min ± 14.10, p < 0.001) was also statistically significantly lower in Group II. Both distal locking screws were significantly closer to perpendicular direction to the nail in Group II. CONCLUSION: The attempt number of image intensifier during the insertion of two distal locking screws was significantly reduced with DTS compared with that with free hand fluoroscopic guidance. Angle between distal locking screws and nail was also more accurate using DTS.


Assuntos
Fluoroscopia , Fixação Intramedular de Fraturas , Exposição à Radiação/estatística & dados numéricos , Cirurgia Assistida por Computador , Fluoroscopia/instrumentação , Fluoroscopia/métodos , Fluoroscopia/estatística & dados numéricos , Fixação Intramedular de Fraturas/instrumentação , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/estatística & dados numéricos , Humanos , Período Intraoperatório , Pessoa de Meia-Idade , Duração da Cirurgia , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/estatística & dados numéricos
12.
J Arthroplasty ; 33(8): 2506-2511, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29739631

RESUMO

BACKGROUND: "Grand-piano sign" has been used as a popular benchmark to facilitate correct rotational alignment during total knee arthroplasty (TKA). The purpose was to quantitatively determine morphological patterns on anterior femoral resection in mechanically aligned (MA) and kinematically aligned (KA) TKA. METHODS: Computed tomography scans of 60 TKA candidates were reconstructed into 3D models. Femurs were virtually cut with a 3D imaging program using various anterior flange flexion angles (AFFAs) of 3°, 5°, and 7°. The anterior femoral resection was performed parallel to the surgical epicondylar axis, at an external rotation and internal rotation of 3° relative to surgical epicondylar axis for MA-TKA, and parallel to the cylindrical axis, at an external rotation and internal rotation of 3° to cylindrical axis for KA-TKA. The ratio of vertical distance from the anterior margin of distal femoral resection to the most proximal peak of each medial and lateral condyle of anterior femoral resection was defined as AC/BC ratio. RESULTS: The mean ratios of AC/BC were 0.57, 0.60, and 0.63 respectively, according to 3°, 5°, and 7° of AFFA with standard MA-TKA method and were 0.73, 0.74, and 0.76, respectively, according to 3°, 5°, and 7° of AFFA with standard KA-TKA method. The AC/BC ratios of malrotated planes were significantly different from those of both standard MA- and KA-TKAs (P-values < .01). CONCLUSION: Surgeons can accessorily use the quantifying method for anterior femoral resection intraoperatively to ensure correct rotational alignment of femoral resection in both mechanically and kinematically aligned TKA.


Assuntos
Artroplastia do Joelho/métodos , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/estatística & dados numéricos , Benchmarking , Fenômenos Biomecânicos , Feminino , Fêmur/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Estudos Retrospectivos , Rotação , Tomografia Computadorizada por Raios X
13.
J Arthroplasty ; 33(3): 777-782, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29153634

RESUMO

BACKGROUND: Treatment of unstable intertrochanteric fracture in elderly patients remains challenging. The purpose of this prospective study is to determine clinical and radiological results of cementless bipolar hemiarthroplasty using a fully porous-coated stem in osteoporotic elderly patients with unstable intertrochanteric fractures with follow-up over 5 years. METHODS: From January 2010 to December 2011, we performed 123 cementless bipolar hemiarthroplasties using fully porous-coated stem to treat unstable intertrochanteric fractures in elderly patients with osteoporosis. Clinical and radiographic evaluations were performed. RESULTS: Fifty-three patients died and 14 patients were lost during the follow-up period. Mean follow-up period was 61.8 months postoperatively. Their mean Harris hip score was 77 points (range 36-100). None of these hips had loosening of the stem or osteolysis. Postoperative complications included nonunion of greater trochanter in 2 hips and dislocation in 2 hips. Two patients were reoperated due to periprosthetic fracture. One patient underwent implant revision due to periprosthetic infection. Thirty-one patients maintained walking activities similar to those before fracture. With follow-up period of 83 months, cumulative survival rates were 97.3% and 99.1% with reoperation for any reason and femoral stem revision as endpoint, respectively. CONCLUSION: Cementless bipolar hemiarthroplasty using a fully porous-coated stem is a useful surgical treatment option for unstable intertrochanteric fracture in elderly patients with osteoporosis.


Assuntos
Artroplastia de Quadril/métodos , Hemiartroplastia/instrumentação , Hemiartroplastia/métodos , Fraturas do Quadril/cirurgia , Prótese de Quadril , Quadril/cirurgia , Fraturas Periprotéticas/cirurgia , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/mortalidade , Feminino , Fêmur/cirurgia , Hemiartroplastia/mortalidade , Humanos , Luxações Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Osteólise/cirurgia , Osteoporose/cirurgia , Porosidade , Complicações Pós-Operatórias/cirurgia , Período Pós-Operatório , Estudos Prospectivos , Desenho de Prótese , Radiografia , Reoperação , Resultado do Tratamento , Caminhada
14.
Arch Orthop Trauma Surg ; 138(8): 1165-1172, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29936580

RESUMO

BACKGROUNDS: Impingement is a risk factor for instability and prosthetic failure following total hip arthroplasty (THA). If the periacetabular osteophytes are not removed at surgery, impingement could occur between the osteophytes and the femoral stem following THA. However, excessive removal of the osteophytes could lead to bleeding from the bone. The aim of our study, therefore, was to locate the site of the impingement and to determine the width of tolerable osteophytes, which does not induce impingement during activities of daily living (ADL), using a three-dimensional simulation. METHODS: On 35 hip models, virtual THA was performed. The acetabular cups were positioned at 45° abduction and 20° anteversion, and the anteversion of femoral stems was 15°. Circular osteophytes with a 30-mm rim were built around the acetabular cup. Fourteen ADL motions were simulated, and the osteophytes were removed until there was no impingement. A clock face was used to map the location and the width of tolerable osteophytes. RESULTS: The impingement mainly occurred in antero-superior and posterior portions around the acetabular cup. Only 4.2-6.2-mm osteophytes were tolerable at the antero-superior portion (12-3 o'clock) and 6.3-7.2-mm osteophytes at the posterior portion (8-10 o'clock) following a total hip arthroplasty. In antero-inferior and postero-superior portions, over-20-mm osteophytes did not induce any impingement. CONCLUSION: Osteophytes in the antero-superior and posterior portion of the acetabulum should be excised during a THA to avoid impingement of the femur-stem construct on the acetabular osteophytes during ADLs.


Assuntos
Acetábulo , Artroplastia de Quadril , Simulação por Computador , Impacto Femoroacetabular , Osteófito , Acetábulo/citologia , Acetábulo/patologia , Acetábulo/fisiopatologia , Acetábulo/cirurgia , Impacto Femoroacetabular/patologia , Impacto Femoroacetabular/fisiopatologia , Impacto Femoroacetabular/prevenção & controle , Quadril/patologia , Quadril/fisiopatologia , Quadril/cirurgia , Humanos , Modelos Biológicos , Osteófito/patologia , Osteófito/fisiopatologia
16.
Bioengineering (Basel) ; 11(4)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38671749

RESUMO

Templating is essential in hip arthroplasty preparation, facilitating implant size prediction and surgical rehearsal. It ensures the selection of suitable implants according to patient anatomy and disease, aiming to minimize post-operative complications. Various templating methods exist, including traditional acetate templating on both analog and digital images, alongside digital templating on digital images, which is categorized into 2D and 3D approaches. Despite the popularity of acetate templating on digital images, challenges such as the requirement for physical templates and result preservation persist. To address these limitations, digital templating with software like OrthoSize and Orthoview has been suggested, although not universally accessible. This technical note advocates for Microsoft PowerPoint as an effective alternative for 2D digital templating, highlighting its user-friendly features for image manipulation without needing specialized software. The described method involves scanning acetate templates, adjusting the images in PowerPoint 365 for size, position, and calibration on patient radiographs, and demonstrating reliability through preliminary assessments, with intraclass correlation coefficient (ICC) values indicating a high level of agreement for cup and stem size (ICC = 0.860, 0.841, respectively) but moderate for neck length (ICC = 0.592). We have introduced a method for performing 2D digital templating in the clinical field without the need for specialized software dedicated to digital templating. We believe this method significantly improves the accessibility to 2D digital templating, which was previously limited by the need for digital templating software. Additionally, it enables surgeons to easily establish arthroplasty plans and share them, overcoming the limitations of acetate templates.

17.
Clin Orthop Surg ; 16(3): 374-381, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38827757

RESUMO

Background: Hemiarthroplasty is frequently used to treat displaced femoral neck fractures in elderly patients, but it has a higher risk of postoperative dislocation. We introduced the posterior approach and inferior capsulotomy (PAICO) to enhance joint stability after bipolar hemiarthroplasty for femoral neck fracture. We evaluated whether the PAICO would have a lower dislocation rate than the conventional posterior approach with superior capsulotomy. Methods: From January 2021 to December 2021, we prospectively recruited 25 patients (25 hips) aged 50 years or older who underwent bipolar hemiarthroplasty for femoral neck fractures due to low-energy trauma as the PAICO group. We compared the PAICO group with a historical control group who had undergone hemiarthroplasty in 7 institutes between 2010 and 2020. The primary endpoint was dislocation within 1 year after the surgery. We compared data from the PAICO group with the data from the historical control group from the Korean Hip Fracture Registry which was carried out in South Korea. Results: A total of 25 patients (25 hips) were enrolled in the present study; 3,477 patients (3,571 hips) who underwent bipolar hemiarthroplasty were reviewed as the historical control group. In the PAICO group, we observed no dislocation, whereas the dislocation rate in the control group was 1.3%. Conclusions: In patients with displaced femoral neck fractures, the PAICO approach demonstrated comparable results in operation time and complication rates when compared to bipolar hemiarthroplasty using superior capsulotomy. Notably, there were no observed cases of dislocation among patients who underwent the PAICO approach. We recommend this PAICO approach to surgeons using the posterior approach, hoping to prevent dislocation in bipolar hemiarthroplasty.


Assuntos
Fraturas do Colo Femoral , Hemiartroplastia , Humanos , Fraturas do Colo Femoral/cirurgia , Hemiartroplastia/métodos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Estudos Prospectivos , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/epidemiologia , Cápsula Articular/cirurgia
18.
ACS Appl Mater Interfaces ; 16(5): 6382-6393, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38279914

RESUMO

A facile and novel fabrication method is demonstrated for creating flexible poly(ethylene terephthalate) (PET)-embedded silver meshes using crack lithography, reactive ion etching (RIE), and reactive silver ink. The crack width and spacing in a waterborne acrylic emulsion polymer are controlled by the thickness of the polymer and the applied stress due to heating and evaporation. Our innovative fabrication technique eliminates the need for sputtering and ensures stronger adhesion of the metal meshes to the PET substrate. Crack trench depths over 5 µm and line widths under 5 µm have been achieved. As a transparent electrode, our flexible embedded Ag meshes exhibit a visible transmission of 91.3% and sheet resistance of 0.54 Ω/sq as well as 93.7% and 1.4 Ω/sq. This performance corresponds to figures of merit (σDC/σOP) of 7500 and 4070, respectively. For transparent electromagnetic interference (EMI) shielding, the metal meshes achieve a shielding efficiency (SE) of 42 dB with 91.3% visible transmission and an EMI SE of 37.4 dB with 93.7% visible transmission. We demonstrate the highest transparent electrode performance of crack lithography approaches in the literature and the highest flexible transparent EMI shielding performance of all fabrication approaches in the literature. These metal meshes may have applications in transparent electrodes, EMI shielding, solar cells, and organic light-emitting diodes.

19.
Sci Rep ; 14(1): 3301, 2024 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-38331977

RESUMO

The study aims to develop a deep learning based automatic segmentation approach using the UNETR(U-net Transformer) architecture to quantify the volume of individual thigh muscles(27 muscles in 5 groups) for Sarcopenia assessment. By automating the segmentation process, this approach improves the efficiency and accuracy of muscle volume calculation, facilitating a comprehensive understanding of muscle composition and its relationship to Sarcopenia. The study utilized a dataset of 72 whole thigh CT scans from hip fracture patients, annotated by two radiologists. The UNETR model was trained to perform precise voxel-level segmentation and various metrics such as dice score, average symmetric surface distance, volume correlation, relative absolute volume difference and Hausdorff distance were employed to evaluate the model's performance. Additionally, the correlation between Sarcopenia and individual thigh muscle volumes was examined. The proposed model demonstrated superior segmentation performance compared to the baseline model, achieving higher dice scores (DC = 0.84) and lower average symmetric surface distances (ASSD = 1.4191 ± 0.91). The volume correlation between Sarcopenia and individual thigh muscles in the male group. Furthermore, the correlation analysis of grouped thigh muscles also showed negative associations with Sarcopenia in the male participants. This thesis presents a deep learning based automatic segmentation approach for quantifying individual thigh muscle volume in sarcopenia assessment. The results highlights the associations between Sarcopenia and specific individual muscles as well as grouped thigh muscle regions, particularly in males. The proposed method improves the efficiency and accuracy of muscle volume calculation, contributing to a comprehensive evaluation of Sarcopenia. This research enhances our understanding of muscle composition and performance, providing valuable insights for effective interventions in Sarcopenia management.


Assuntos
Sarcopenia , Humanos , Masculino , Sarcopenia/diagnóstico por imagem , Coxa da Perna/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Músculo Esquelético/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
20.
PeerJ ; 12: e17509, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39161969

RESUMO

Background: Hip fractures are a common and debilitating condition, particularly among older adults. Loss of muscle mass and strength is a common consequence of hip fractures, which further contribute to functional decline and increased disability. Assessing changes in individual thigh muscles volume in follow-up patients can provide valuable insights into the quantitative recovery process and guide rehabilitation interventions. However, accurately measuring anatomical individual thigh muscle volume can be challenging due to various, labor intensive and time-consuming. Materials and Methods: This study aimed to evaluate differences in thigh muscle volume in followed-up hip fracture patients computed tomography (CT) scans using an AI based automatic muscle segmentation model. The study included a total of 18 patients at Gyeongsang National University, who had undergone surgical treatment for a hip fracture. We utilized the automatic segmentation algorithm which we have already developed using UNETR (U-net Transformer) architecture, performance dice score = 0.84, relative absolute volume difference 0.019 ± 0.017%. Results: The results revealed intertrochanteric fractures result in more significant muscle volume loss (females: -97.4 cm3, males: -178.2 cm3) compared to femoral neck fractures (females: -83 cm3, males: -147.2 cm3). Additionally, the study uncovered substantial disparities in the susceptibility to volume loss among specific thigh muscles, including the Vastus lateralis, Adductor longus and brevis, and Gluteus maximus, particularly in cases of intertrochanteric fractures. Conclusions: The use of an automatic muscle segmentation model based on deep learning algorithms enables efficient and accurate analysis of thigh muscle volume differences in followed up hip fracture patients. Our findings emphasize the significant muscle loss tied to sarcopenia, a critical condition among the elderly. Intertrochanteric fractures resulted in greater muscle volume deformities, especially in key muscle groups, across both genders. Notably, while most muscles exhibited volume reduction following hip fractures, the sartorius, vastus and gluteus groups demonstrated more significant disparities in individuals who sustained intertrochanteric fractures. This non-invasive approach provides valuable insights into the extent of muscle atrophy following hip fracture and can inform targeted rehabilitation interventions.


Assuntos
Fraturas do Quadril , Músculo Esquelético , Coxa da Perna , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Fraturas do Quadril/cirurgia , Fraturas do Quadril/diagnóstico por imagem , Idoso , Estudos Retrospectivos , Coxa da Perna/diagnóstico por imagem , Coxa da Perna/lesões , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/lesões , Idoso de 80 Anos ou mais , Algoritmos , Inteligência Artificial , Seguimentos , Tamanho do Órgão
SELEÇÃO DE REFERÊNCIAS