Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 528(7582): 387-91, 2015 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-26641312

RESUMO

Radiative transfer of energy at the nanometre length scale is of great importance to a variety of technologies including heat-assisted magnetic recording, near-field thermophotovoltaics and lithography. Although experimental advances have enabled elucidation of near-field radiative heat transfer in gaps as small as 20-30 nanometres (refs 4-6), quantitative analysis in the extreme near field (less than 10 nanometres) has been greatly limited by experimental challenges. Moreover, the results of pioneering measurements differed from theoretical predictions by orders of magnitude. Here we use custom-fabricated scanning probes with embedded thermocouples, in conjunction with new microdevices capable of periodic temperature modulation, to measure radiative heat transfer down to gaps as small as two nanometres. For our experiments we deposited suitably chosen metal or dielectric layers on the scanning probes and microdevices, enabling direct study of extreme near-field radiation between silica-silica, silicon nitride-silicon nitride and gold-gold surfaces to reveal marked, gap-size-dependent enhancements of radiative heat transfer. Furthermore, our state-of-the-art calculations of radiative heat transfer, performed within the theoretical framework of fluctuational electrodynamics, are in excellent agreement with our experimental results, providing unambiguous evidence that confirms the validity of this theory for modelling radiative heat transfer in gaps as small as a few nanometres. This work lays the foundations required for the rational design of novel technologies that leverage nanoscale radiative heat transfer.

2.
Nature ; 498(7453): 209-12, 2013 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-23765496

RESUMO

Atomic and single-molecule junctions represent the ultimate limit to the miniaturization of electrical circuits. They are also ideal platforms for testing quantum transport theories that are required to describe charge and energy transfer in novel functional nanometre-scale devices. Recent work has successfully probed electric and thermoelectric phenomena in atomic-scale junctions. However, heat dissipation and transport in atomic-scale devices remain poorly characterized owing to experimental challenges. Here we use custom-fabricated scanning probes with integrated nanoscale thermocouples to investigate heat dissipation in the electrodes of single-molecule ('molecular') junctions. We find that if the junctions have transmission characteristics that are strongly energy dependent, this heat dissipation is asymmetric--that is, unequal between the electrodes--and also dependent on both the bias polarity and the identity of the majority charge carriers (electrons versus holes). In contrast, junctions consisting of only a few gold atoms ('atomic junctions') whose transmission characteristics show weak energy dependence do not exhibit appreciable asymmetry. Our results unambiguously relate the electronic transmission characteristics of atomic-scale junctions to their heat dissipation properties, establishing a framework for understanding heat dissipation in a range of mesoscopic systems where transport is elastic--that is, without exchange of energy in the contact region. We anticipate that the techniques established here will enable the study of Peltier effects at the atomic scale, a field that has been barely explored experimentally despite interesting theoretical predictions. Furthermore, the experimental advances described here are also expected to enable the study of heat transport in atomic and molecular junctions--an important and challenging scientific and technological goal that has remained elusive.

3.
Nano Lett ; 12(9): 4472-6, 2012 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-22888862

RESUMO

Thermopower (S) profiling with nanometer resolution is essential for enhancing the thermoelectric figure of merit, ZT, through the nanostructuring of materials and for carrier density profiling in nanoelectronic devices. However, only qualitative and impractical methods or techniques with low resolutions have been reported thus far. Herein, we develop a quantitative S profiling method with nanometer resolution, scanning Seebeck microscopy (SSM), and batch-fabricate diamond thermocouple probes to apply SSM to silicon, which requires a contact stress higher than 10 GPa for stable electrical contact. The distance between the positive and negative peaks of the S profile across the silicon p-n junction measured by SSM is 4 nm, while the theoretical distance is 2 nm. Because of its extremely high spatial resolution, quantitative measurement, and ease of use, SSM could be a crucial tool not only for the characterization of nano-thermoelectric materials and nanoelectronic devices but also for the analysis of nanoscale thermal and electrical phenomena in general.


Assuntos
Eletrodos , Teste de Materiais/métodos , Semicondutores , Termografia/métodos , Temperatura
4.
Nanomaterials (Basel) ; 12(9)2022 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-35564188

RESUMO

The thermophysical properties at the nanoscale are key characteristics that determine the operation of nanoscale devices. Additionally, it is important to measure and verify the thermal transfer characteristics with a few nanometer or atomic-scale resolutions, as the nanomaterial research field has expanded with respect to the development of molecular and atomic-scale devices. Scanning thermal microscopy (SThM) is a well-known method for measuring the thermal transfer phenomena with the highest spatial resolution. However, considering the rapid development of atomic materials, the development of an ultra-sensitive SThM for measuring pico-watt (pW) level heat transfer is essential. In this study, to measure molecular- and atomic-scale phenomena, a pico-watt scanning thermal microscopy (pW-SThM) equipped with a calorimeter capable of measuring heat at the pW level was developed. The heat resolution of the pW-SThM was verified through an evaluation experiment, and it was confirmed that the temperature of the metal line heater sample could be quantitatively measured by using the pW-SThM. Finally, we demonstrated that pW-SThM detects ultra-small differences of local heat transfer that may arise due to differences in van der Waals interactions between the graphene sheets in highly ordered pyrolytic graphite. The pW-SThM probe is expected to significantly contribute to the discovery of new heat and energy transfer phenomena in nanodevices and two-dimensional materials that have been inaccessible through experiments.

5.
Polymers (Basel) ; 13(22)2021 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-34833318

RESUMO

The Nafion® electrolyte membrane, which provides a proton pathway, is an essential element in fuel cell systems. Thermal treatment without additional additives is widely used to modify the mechanical properties of the membrane, to construct reliable and durable electrolyte membranes in the fuel cell. We measured the microscopic mechanical properties of thermally annealed membranes using atomic force microscopy with the two-point method. Furthermore, the macroscopic property was investigated through tensile tests. The microscopic modulus exceeded the macroscopic modulus over all annealing temperature ranges. Additionally, the measured microscopic modulus increased rapidly near 150 °C and was saturated over that temperature, whereas the macroscopic modulus continuously increased until 250 °C. This mismatched micro/macroscopic reinforcement trend indicates that the internal reinforcement of the clusters is induced first until 150 °C. In contrast, the reinforcement among the clusters, which requires more thermal energy, probably progresses even at a temperature of 250 °C. The results showed that the annealing process is effective for the surface smoothing and leveling of the Nafion® membrane until 200 °C.

6.
Nat Nanotechnol ; 9(11): 881-5, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25282046

RESUMO

Molecular junctions hold significant promise for efficient and high-power-output thermoelectric energy conversion. Recent experiments have probed the thermoelectric properties of molecular junctions. However, electrostatic control of thermoelectric properties via a gate electrode has not been possible due to technical challenges in creating temperature differentials in three-terminal devices. Here, we show that extremely large temperature gradients (exceeding 1 × 10(9) K m(-1)) can be established in nanoscale gaps bridged by molecules, while simultaneously controlling their electronic structure via a gate electrode. Using this platform, we study prototypical Au-biphenyl-4,4'-dithiol-Au and Au-fullerene-Au junctions to demonstrate that the Seebeck coefficient and the electrical conductance of molecular junctions can be simultaneously increased by electrostatic control. Moreover, from our studies of fullerene junctions, we show that thermoelectric properties can be significantly enhanced when the dominant transport orbital is located close to the chemical potential (Fermi level) of the electrodes. These results illustrate the intimate relationship between the thermoelectric properties and charge transmission characteristics of molecular junctions and should enable systematic exploration of the recent computational predictions that promise extremely efficient thermoelectric energy conversion in molecular junctions.

7.
ACS Nano ; 6(5): 4248-57, 2012 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-22530657

RESUMO

Understanding energy dissipation at the nanoscale requires the ability to probe temperature fields with nanometer resolution. Here, we describe an ultra-high vacuum (UHV)-based scanning thermal microscope (SThM) technique that is capable of quantitatively mapping temperature fields with ∼15 mK temperature resolution and ∼10 nm spatial resolution. In this technique, a custom fabricated atomic force microscope (AFM) cantilever, with a nanoscale Au-Cr thermocouple integrated into the tip of the probe, is used to measure temperature fields of surfaces. Operation in an UHV environment eliminates parasitic heat transport between the tip and the sample enabling quantitative measurement of temperature fields on metal and dielectric surfaces with nanoscale resolution. We demonstrate the capabilities of this technique by directly imaging thermal fields in the vicinity of a 200 nm wide, self-heated, Pt line. Our measurements are in excellent agreement with computational results-unambiguously demonstrating the quantitative capabilities of the technique. UHV-SThM techniques will play an important role in the study of energy dissipation in nanometer-sized electronic and photonic devices and the study of phonon and electron transport at the nanoscale.

8.
ACS Nano ; 5(11): 8700-9, 2011 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-21999681

RESUMO

Because of its high spatial resolution, scanning thermal microscopy (SThM) has been developed quite actively and applied in such diverse areas as microelectronics, optoelectronics, polymers, and carbon nanotubes for more than a decade since the 1990s. However, despite its long history and diverse areas of application, surprisingly, no quantitative profiling method has been established yet. This is mostly due to the nonlocal nature of measurement by conventional SThM: the signal measured by SThM is induced not only from the local heat flux through the tip-sample thermal contact but also (and mostly) from the heat flux through the air gap between the sample and the SThM probe. In this study, a rigorous but simple and practical theory for quantitative SThM for local measurement is established and verified experimentally using high-performance SThM probes. The development of quantitative SThM will make possible new breakthroughs in diverse fields of nanothermal science and engineering.

9.
Rev Sci Instrum ; 81(11): 114901, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21133490

RESUMO

Previously, we introduced the double scan technique, which enables quantitative temperature profiling with a scanning thermal microscope (SThM) without distortion arising from heat transfer through the air. However, if the tip-sample thermal conductance is disturbed due to the extremely small size of the sample, such as carbon nanotubes, or an abrupt change in the topography, then quantitative measurement becomes difficult even with the double scan technique. Here, we developed the null-point method by which one can quantitatively measure the temperature of a sample without disturbances arising from the tip-sample thermal conductance, based on the principle of the double scan technique. We first checked the effectiveness and accuracy of the null-point method using 5 µm and 400 nm wide aluminum lines. Then, we quantitatively measured the temperature of electrically heated multiwall carbon nanotubes using the null-point method. Since the null-point method has an extremely high spatial resolution of SThM and is free from disturbance due to the tip-sample thermal contact resistance, and distortion due to heat transfer through the air, the method is expected to be widely applicable for the thermal characterization of many nanomaterials and nanodevices.

10.
Rev Sci Instrum ; 81(5): 053701, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20515139

RESUMO

The need for a subsurface imaging technique to locate and characterize subsurface defects in multidimensional micro- and nanoengineered devices has been growing rapidly. We show that a subsurface heater can be located accurately using the phase lag of a thermal wave. We deduce that the absolute phase lag is composed of four components. Among the four components, we isolate the component directly related to the position and the structure of the periodic heat source. We demonstrate that the position of the heater can be estimated accurately from the isolated phase lag component.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa