Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Fluoresc ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38954086

RESUMO

We present a comprehensive fluorescence characterization of seven water-soluble rhodamine derivatives for applications in laser-induced fluorescence (LIF) techniques. Absorption and emission spectra for these dyes are presented over the visible spectrum of wavelengths (400 to 700 nm). Their fluorescence properties were also investigated as a function of temperature for LIF thermometry applications. Rhodamine 110 depicted the least fluorescence emission sensitivity to temperature at -0.11%/°C, while rhodamine B depicted the most with a -1.55%/°C. We found that the absorption spectra of these molecules are independent of temperature, supporting the notion that the temperature sensitivity of their emission only comes from changes in quantum yield with temperature. Conversely, these rhodamine fluorophores showed no change in emission intensities with pH variations and are, therefore, not suitable tracers for pH measurements. Similarly, fluorescent lifetime, which is also a property sensitive to local environmental changes in temperature, pH, and ion concentration, measurements were conducted for these fluorophores. It was found that rhodamine B and kiton red 620 have shorter fluorescence timescales compared to those of the other five rhodamine dyes, making them least suitable for applications where temporal changes in emission are monitored. Lastly, we conducted experiments to assess the physicochemical absorption characteristics of these dyes' molecules into polydimethylsiloxane (PDMS), the most common material for microfluidic devices. Rhodamine B showed the highest diffusion into PDMS substrates as compared to the other derivative dyes.

2.
Sci Rep ; 14(1): 9201, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649763

RESUMO

In this study, we address two technical challenges to enhance golf swing trajectory accuracy using a wrist-worn inertial sensor: orientation estimation and drift error mitigation. We extrapolated consistent sensor orientation from specific address-phase signal segments and trained the estimation with a convolutional neural network. We then mitigated drift error by applying a constraint on wrist speed at the address, backswing top, and finish, and ensuring that the wrist's finish displacement aligns with a virtual circle on the 3D swing plane. To verify the proposed methods, we gathered data from twenty male right-handed golfers, including professionals and amateurs, using a driver and a 7-iron. The orientation estimation error was about 60% of the baseline, comparable to studies requiring additional sensor information or calibration poses. The drift error was halved and the single-inertial-sensor tracking performance across all swing phases was about 17 cm, on par with multimodal approaches. This study introduces a novel signal processing method for tracking rapid, wide-ranging motions, such as a golf swing, while maintaining user convenience. Our results could impact the burgeoning field of daily motion monitoring for health care, especially with the increasing prevalence of wearable devices like smartwatches.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa