Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Circ J ; 81(9): 1272-1277, 2017 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-28428489

RESUMO

BACKGROUND: Shocks delivered by implanted anti-tachyarrhythmia devices, even when appropriate, lower the quality of life and survival. The new SmartShock Technology®(SST) discrimination algorithm was developed to prevent the delivery of inappropriate shock. This prospective, multicenter, observational study compared the rate of inaccurate detection of ventricular tachyarrhythmia using the SST vs. a conventional discrimination algorithm.Methods and Results:Recipients of implantable cardioverter defibrillators (ICD) or cardiac resynchronization therapy defibrillators (CRT-D) equipped with the SST algorithm were enrolled and followed up every 6 months. The tachycardia detection rate was set at ≥150 beats/min with the SST algorithm. The primary endpoint was the time to first inaccurate detection of ventricular tachycardia (VT) with conventional vs. the SST discrimination algorithm, up to 2 years of follow-up. Between March 2012 and September 2013, 185 patients (mean age, 64.0±14.9 years; men, 74%; secondary prevention indication, 49.5%) were enrolled at 14 Japanese medical centers. Inaccurate detection was observed in 32 patients (17.6%) with the conventional, vs. in 19 patients (10.4%) with the SST algorithm. SST significantly lowered the rate of inaccurate detection by dual chamber devices (HR, 0.50; 95% CI: 0.263-0.950; P=0.034). CONCLUSIONS: Compared with previous algorithms, the SST discrimination algorithm significantly lowered the rate of inaccurate detection of VT in recipients of dual-chamber ICD or CRT-D.


Assuntos
Algoritmos , Desfibriladores Implantáveis , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/terapia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
2.
J Arrhythm ; 37(4): 1052-1060, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34386132

RESUMO

BACKGROUND: An implantable cardioverter defibrillator (ICD) is the most reliable therapeutic device for preventing sudden cardiac death in patients with sustained ventricular tachycardia (VT). Regarding its effectiveness, targeted VT is defined based on the tachyarrhythmia cycle length. However, variations in RR interval variability of VTs may occur. Few studies have reported on VT characteristics and effects of ICD therapy according to the RR interval variability. We aimed to identify the clinical characteristics of VTs and ICD therapy effects according to the RR interval variability. METHODS: We analyzed 821 VT episodes in 69 patients with ICDs or cardiac resynchronization therapy defibrillators. VTs were classified as irregular when the difference between two successive beats was >20 ms in at least one of 10 RR intervals; otherwise, they were classified as regular. We evaluated successful termination using anti-tachycardia pacing (ATP)/shock therapy, spontaneous termination, and acceleration between regular and irregular VTs. The RR interval variability reproducibility rates were evaluated. RESULTS: Regular VT was significantly more successfully terminated than irregular VT by ATP. No significant difference was found in shock therapy or VT acceleration between the regular and irregular VTs. Spontaneous termination occurred significantly more often in irregular than in regular VT cases. The reproducibility rates of RR interval variability in each episode and in all episodes were 89% and 73%, respectively. CONCLUSIONS: ATP therapy showed greater effectiveness for regular than for irregular VT. Spontaneous termination was more common in irregular than in regular VT. RR interval variability of VTs seems to be reproducible.

3.
Intern Med ; 51(21): 3035-40, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23124146

RESUMO

A 43-year-old man was admitted to our hospital presenting with seizures and syncope. He had a history of a cold with a fever of 39°C occurring three days earlier. Electrocardiography (ECG) showed complete atrioventricular block (AV block) with a maximum pause of 32 seconds, for which temporary pacing was performed. Echocardiography showed mild hypertrophy of the left ventricle (LV) with a normal ejection fraction of 61%. Coronary angiography showed normal coronary arteries. Then, an endomyocardial biopsy was performed, the results of which indicated a diagnosis of acute myocarditis. After admission, the complete atrioventricular block disappeared together with normalization of the LV wall thickness.


Assuntos
Bloqueio Atrioventricular/complicações , Miocardite/complicações , Convulsões/etiologia , Síncope/etiologia , Doença Aguda , Adulto , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial , Ecocardiografia , Eletrocardiografia , Humanos , Hipertrofia Ventricular Esquerda/etiologia , Masculino , Miocardite/diagnóstico , Miocardite/fisiopatologia , Sístole , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa