Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 185
Filtrar
1.
Respir Res ; 25(1): 117, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38454475

RESUMO

Heart surgery may be complicated by acute lung injury and adult respiratory distress syndrome. Expression and release of mucins MUC5AC and MUC5B in the lungs has been reported to be increased in acute lung injury. The aim of our study was to [1] investigate the perioperative changes of MUC5AC, MUC5B and other biomarkers in mini-bronchoalveolar lavage (minBAL), and [2] relate these to clinical outcomes after cardiac surgery. In this prospective cohort study in 49 adult cardiac surgery patients pre- and post-surgery non-fiberscopic miniBAL fluids were analysed for MUC5AC, MUC5B, IL-8, human neutrophil elastase, and neutrophils. All measured biomarkers increased after surgery. Perioperative MUC5AC-change showed a significant negative association with postoperative P/F ratio (p = 0.018), and a positive association with ICU stay (p = 0.027). In conclusion, development of lung injury after cardiac surgery and prolonged ICU stay are associated with an early increase of MUC5AC as detected in mini-BAL.


Assuntos
Lesão Pulmonar Aguda , Procedimentos Cirúrgicos Cardíacos , Adulto , Humanos , Líquido da Lavagem Broncoalveolar , Estudos Prospectivos , Lesão Pulmonar Aguda/diagnóstico , Lesão Pulmonar Aguda/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Biomarcadores/análise , Mucina-5AC/metabolismo
2.
BMC Cardiovasc Disord ; 24(1): 258, 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762715

RESUMO

BACKGROUND: Extracorporeal blood purification has been widely used in intensive care medicine, nephrology, toxicology, and other fields. During the last decade, with the emergence of new adsorptive blood purification devices, hemoadsorption has been increasingly applied during CPB in cardiac surgery, for patients at different inflammatory risks, or for postoperative complications. Clinical evidence so far has not provided definite answers concerning this adjunctive treatment. The current systematic review aimed to critically assess the role of perioperative hemoadsorption in cardiac surgery, by summarizing the current knowledge in this clinical setting. METHODS: A literature search of PubMed, Cochrane library, and the database provided by CytoSorbents was conducted on June 1st, 2023. The search terms were chosen by applying neutral search keywords to perform a non-biased systematic search, including language variations of terms "cardiac surgery" and "hemoadsorption". The screening and selection process followed scientific principles (PRISMA statement). Abstracts were considered for inclusion if they were written in English and published within the last ten years. Publications were eligible for assessment if reporting on original data from any type of study (excluding case reports) in which a hemoadsorption device was investigated during or after cardiac surgery. Results were summarized according to sub-fields and presented in a tabular view. RESULTS: The search resulted in 29 publications with a total of 1,057 patients who were treated with hemoadsorption and 988 control patients. Articles were grouped and descriptively analyzed due to the remarkable variability in study designs, however, all reported exclusively on CytoSorb® therapy. A total of 62% (18/29) of the included articles reported on safety and no unanticipated adverse events have been observed. The most frequently reported clinical outcome associated with hemoadsorption was reduced vasopressor demand resulting in better hemodynamic stability. CONCLUSIONS: The role of hemoadsorption in cardiac surgery seems to be justified in selected high-risk cases in infective endocarditis, aortic surgery, heart transplantation, and emergency surgery in patients under antithrombotic therapy, as well as in those who develop a dysregulated inflammatory response, vasoplegia, or septic shock postoperatively. Future large randomized controlled trials are needed to better define proper patient selection, dosing, and timing of the therapy.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Humanos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Complicações Pós-Operatórias/terapia , Complicações Pós-Operatórias/etiologia , Ponte Cardiopulmonar/efeitos adversos , Masculino , Feminino , Medição de Risco , Idoso , Pessoa de Meia-Idade
3.
BMC Cardiovasc Disord ; 23(1): 363, 2023 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-37468858

RESUMO

INTRODUCTION: Bicuspid aortic valve (BAV) patients have an increased risk to develop thoracic aortic complications. Little is known about the prevalence and severity of atherosclerosis in the BAV ascending aortic wall. This study evaluates and compares the prevalence of thoracic aortic atherosclerosis in BAV and tricuspid aortic valve (TAV) patients. METHODS: Atherosclerosis was objectified using three diagnostic modalities in two separate BAV patient cohorts (with and without an aortic dilatation). Within the first group, atherosclerosis was graded histopathologically according to the modified AHA classification scheme proposed by Virmani et al. In the second group, the calcific load of the ascending aorta and coronary arteries, coronary angiographies and cardiovascular risk factors were studied. Patients were selected from a surgical database (treated between 2006-2020), resulting in a total of 128 inclusions. RESULTS: Histopathology showed atherosclerotic lesions to be more prevalent and severe in all TAV as compared to all BAV patients (OR 1.49 (95%CI 1.14 - 1.94); p = 0.003). Computed tomography showed no significant differences in ascending aortic wall calcification between all BAV and all TAV patients, although a tendency of lower calcific load in favor of BAV was seen. Coronary calcification was higher in all TAV as compared to all BAV (OR 1.30 (95%CI 1.06 - 1.61); p = 0.014). CONCLUSION: Ascending aortic atherosclerotic plaques were histologically more pronounced in TAV as compared to the BAV patients, while CT scans revealed equal amounts of calcific depositions within the ascending aortic wall. This study confirms less atherosclerosis in the ascending aortic wall and coronary arteries of BAV patients as compared to TAV patients. These results were not affected by the presence of a thoracic aortic aneurysm.


Assuntos
Doenças da Aorta , Aterosclerose , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Humanos , Doença da Válvula Aórtica Bicúspide/complicações , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/epidemiologia , Doenças das Valvas Cardíacas/complicações , Estudos de Casos e Controles , Valva Aórtica/cirurgia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/epidemiologia , Doenças da Aorta/complicações , Aterosclerose/diagnóstico por imagem , Aterosclerose/epidemiologia
4.
Thorac Cardiovasc Surg ; 71(5): 387-397, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-35644134

RESUMO

BACKGROUND: The advent of transcatheter aortic valve replacement (AVR) has led to an increased emphasis on reducing the invasiveness of surgical procedures. The aim of this study was to evaluate clinical outcomes and hemodynamic performance achieved with minimally invasive aortic valve replacement (MI-AVR) as compared with conventional AVR. METHODS: Patients who underwent surgical AVR with the Avalus bioprosthesis, as part of a prospective multicenter non-randomized trial, were included in this analysis. Surgical approach was left to the discretion of the surgeons. Patient characteristics and clinical outcomes were compared between MI-AVR and conventional AVR groups in the entire cohort (n = 1077) and in an isolated AVR subcohort (n = 528). Propensity score adjustment was performed to estimate the effect of MI-AVR on adverse events. RESULTS: Patients treated with MI-AVR were younger, had lower STS scores, and underwent concomitant procedures less often. Valve size implanted was comparable between the groups. MI-AVR was associated with longer procedural times in the isolated AVR subcohort. Postprocedural hemodynamic performance was comparable. There were no significant differences between MI-AVR and conventional AVR in early and 3-year all-cause mortality, thromboembolism, reintervention, or a composite of those endpoints within either the entire cohort or the isolated AVR subcohort. After propensity score adjustment, there remained no association between MI-AVR and the composite endpoint (hazard ratio: 0.86, 95% confidence interval: 0.47-1.55, p = 0.61). CONCLUSION: Three-year outcomes after MI-AVR with the Avalus bioprosthetic valve were comparable to conventional AVR. These results provide important insights into the overall ability to reduce the invasiveness of AVR without compromising outcomes.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Estudos Retrospectivos
5.
Echocardiography ; 40(9): 892-902, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37519290

RESUMO

AIMS: The present guidelines advise replacing the aortic valve for individuals with severe aortic stenosis (AS) based on various echocardiographic parameters. Accurate measurements are essential to avoid misclassification and unnecessary interventions. The objective of this study was to evaluate the influence of measurement error on the echocardiographic evaluation of the severity of AS. METHODS AND RESULTS: A systematic review was performed to examine whether measurement errors are reported in studies focusing on the prognostic value of peak aortic jet velocity (Vmax ), mean pressure gradient (MPG), and effective orifice area (EOA) in asymptomatic patients with AS. Out of the 37 studies reviewed, 17 (46%) acknowledged the existence of measurement errors, but none of them utilized methods to address them. Secondly, the magnitude of potential errors was collected from available literature for use in clinical simulations. Interobserver variability ranged between 0.9% and 8.3% for Vmax and MPG but was higher for EOA (range 7.7%-12.7%), indicating lower reliability. Assuming a circular left ventricular outflow tract area led to a median underestimation of EOA by 23% compared to planimetry by other modalities. A clinical simulation resulted in the reclassification of 42% of patients, shifting them from a diagnosis of severe AS to moderate AS. CONCLUSIONS: Measurement errors are underreported in studies on echocardiographic assessment of AS severity. These errors can lead to misclassification and misdiagnosis. Clinicians and scientists should be aware of the implications for accurate clinical decision-making and assuring research validity.


Assuntos
Estenose da Valva Aórtica , Humanos , Reprodutibilidade dos Testes , Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Valva Aórtica/diagnóstico por imagem , Volume Sistólico , Índice de Gravidade de Doença
6.
Am Heart J ; 249: 66-75, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35436505

RESUMO

STUDY OBJECTIVE: The added value of computed tomography (CT) follow-up after elective proximal aortic surgery is unclear. We evaluated the benefit of CT follow-up by assessing the incidence of aorta-related complications and reinterventions detected during routine CT follow-up. METHODS: Data on 314 patients undergoing first time elective proximal aortic surgery between 2000 and 2015 were collected. The primary study end points were aorta-related complications and reinterventions, detected during routine CT follow-up. Secondary study endpoints included all aorta-related complications and reinterventions, irrespective of the mode of detection and survival. RESULTS: Median CT follow-up time was 6.8 (IQR 4.1-9.8) years, during which a total of 1303 routine follow-up CT-scans (median 4, IQR 3-5) were performed. During CT follow-up, aorta-related complications were detected in 18 (5.7%) patients, of which 6 (1.6%) underwent reintervention. In total, 28 aorta-related complications were observed in 23 (7.3%) patients, of which 9 led to reintervention. In order to detect 1 aorta-related complication leading to reintervention, 218 routine follow-up CT-scans were required. The unadjusted and EuroSCORE II adjusted hazard ratios of not undergoing CT follow-up on mortality were 1.260 (95% CI 0.705-2.251) and 0.830 (95% CI 0.430-1.605), respectively. CONCLUSIONS: Following first time elective proximal aortic surgery, aorta-related complications are uncommon, are not always detected during CT follow-up and, if detected, often do not result in reintervention. Therefore, a more conservative CT follow-up protocol could be considered in selected patients to reduce lifetime radiation burden and health care costs.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Aorta , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/métodos , Seguimentos , Humanos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X , Resultado do Tratamento
7.
J Cardiothorac Vasc Anesth ; 36(1): 109-117, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34602324

RESUMO

OBJECTIVE: The aim of this survey was to describe existing perioperative care standards and best practices in the Netherlands and Belgium. DESIGN: An online survey was followed up by an in-depth personal interview. The main outcomes were the existing standards of perioperative care for patients undergoing cardiac surgery. SETTING: The online survey and subsequent interviews were targeted to one representative in the intensive care unit (ICU), cardiac surgery, and anesthesiology department from each cardiac surgical center in the Netherlands and Belgium. PARTICIPANTS: A representative intensive care physician, cardiac surgeon, and cardiac anesthesiologist. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The response rate was 60% (71% for the Netherlands, and 44% in Belgium). Agreement across centers was found for discontinuation of proton-pump inhibitors (80%) and avoiding intra- and postoperative (92%) nonsteroidal antiinflammatory drugs. Additionally, 98% of respondents stated that physiotherapy should be started immediately in the ICU. Major divergence was found for elements such as the discontinuation of angiotensin-converting enzyme inhibitors (55%) or the postoperative use of chest support vests (44%). CONCLUSIONS: The authors demonstrated a wide range of different local protocols. Strategies differed among disciplines, hospitals, and countries. This emphasized the need for the implementation of a more universal protocol to further reduce variance and improve recovery practices. This nationwide survey was the first of its kind simultaneously studying best practices for cardiac surgery through the entire care pathway at the advent of Enhanced Recovery After Surgery (ERAS) Cardiac implementation. A multinational randomized controlled trial to test the implementation of an evidence-based ERAS Cardiac protocol is the next step to pave the way for further outcome improvements in this high-risk population.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Complicações Pós-Operatórias , Bélgica , Humanos , Tempo de Internação , Países Baixos , Assistência Perioperatória , Inquéritos e Questionários
8.
Surg Technol Int ; 412022 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-36265121

RESUMO

Growing interest in minimalizing surgical trauma during heart procedures stimulated the development of robotic mitral valve surgery in the late 1990s. Initially, the new technology was slowly adopted in clinical practice. However, following encouraging results by teams that adopted robotic heart surgery early on, a growing interest in implementation of robotic mitral valve surgery has emerged. Of importance are the technical developments and possibilities that accompany robotic surgery. Robotic arms feature unique characteristics, allowing unparalleled range of motion and allowing complex mitral valve repair techniques to be performed without limitations related to limited surgical incisions. High-quality three-dimensional vision effectively compensates for the lack of tactile feedback. Several technical solutions have been developed to facilitate mitral valve repair in minimal invasive setting, including chordal guiding systems, now available with various annuloplasty rings. On the other hand, precise vision and movements allows accurate determination of the length of implanted neochordae, facilitating precise determination of the length of implanted neochords even without the use of chordal-guiding systems. With robotic mitral valve surgery, leaflet resection techniques can be performed without limitations, ensuring that no compromises of the surgical strategy are made. Nevertheless, careful preoperative planning with appropriate work-up and imaging is of utmost importance to prevent complications. Moreover, the drawbacks of the initial learning curve and higher procedural costs are counterbalanced by less surgical trauma, lower utilization of blood products, and faster patient recovery. Robotic mitral valve surgery is still a young field and evolving technology that is bound to become an important tool in the toolbox of surgical mitral valve approaches.

9.
Acta Chir Belg ; 122(2): 77-84, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34913838

RESUMO

In the field of cardiovascular surgery, many areas are frequently evaluated to improve patient outcomes. Even though cardiac surgery has advanced significantly, peri-operative nutrition remains an area needing special attention and is under-considered in patient results. The three portions of cardiac surgical nutrition optimization are pre-operative, intra-operative and post-operative. All these, merit important clinical intervention which when done properly can significantly improve patient recovery and reduce morbidity and mortality. Here we provide a narrative review and recommendations for peri-operative nutritional optimization in cardiac surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Humanos , Morbidade
11.
J Card Surg ; 35(12): 3477-3485, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33085138

RESUMO

OBJECTIVE: The hemodynamic effect and early and late survival impact of prosthesis-patient mismatch (PPM) after mitral valve replacement remains insufficiently explored. METHODS: Pubmed, Embase, Web of Science, and Cochrane Library databases were searched for English language original publications. The search yielded 791 potentially relevant studies. The final review and analysis included 19 studies compromising 11,675 patients. RESULTS: Prosthetic effective orifice area was calculated with the continuity equation method in 7 (37%), pressure half-time method in 2 (10%), and partially or fully obtained from referenced values in 10 (53%) studies. Risk factors for PPM included gender (male), diabetes mellitus, chronic renal disease, and the use of bioprostheses. When pooling unadjusted data, PPM was associated with higher perioperative (odds ratio [OR]: 1.66; 95% confidence interval [CI]: 1.32-2.10; p < .001) and late mortality (hazard ratio [HR]: 1.46; 95% CI: 1.21-1.77; p < .001). Moreover, PPM was associated with higher late mortality when Cox proportional-hazards regression (HR: 1.97; 95% CI: 1.57-2.47; p < .001) and propensity score (HR: 1.99; 95% CI: 1.34-2.95; p < .001) adjusted data were pooled. Contrarily, moderate (HR: 1.01; 95% CI: 0.84-1.22; p = .88) or severe (HR: 1.19; 95% CI: 0.89-1.58; p = .24) PPM were not related to higher late mortality when adjusted data were pooled individually. PPM was associated with higher systolic pulmonary pressures (mean difference: 7.88 mmHg; 95% CI: 4.72-11.05; p < .001) and less pulmonary hypertension regression (OR: 5.78; 95% CI: 3.33-10.05; p < .001) late after surgery. CONCLUSIONS: Mitral valve PPM is associated with higher postoperative pulmonary artery pressure and might impair perioperative and overall survival. The relation should be further assessed in properly designed studies.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Masculino , Valva Mitral/cirurgia , Fatores de Risco , Resultado do Tratamento
12.
Eur Heart J ; 40(27): 2206-2214, 2019 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-31114862

RESUMO

AIMS: Recurrent mitral regurgitation (MR) has been reported after mitral valve repair for functional MR. However, the impact of recurrent MR on long-term survival remains poorly defined. In the present study, mortality-adjusted recurrent MR rates, the clinical impact of recurrent MR and its determinants were studied in patients after mitral valve repair with revascularization for functional MR in the setting of ischaemic heart disease. METHODS AND RESULTS: Long-term clinical and echocardiographic outcome was evaluated in 261 consecutive patients after restrictive mitral annuloplasty and revascularization for moderate to severe functional MR, between 2000 and 2014. The cumulative incidence of recurrent MR ≥ Grade 2, assessed by competing risk analysis, was 9.6 ± 1.8% at 1-year, 20.3 ± 2.5% at 5-year, and 27.6 ± 2.9% at 10-year follow-up. Cumulative survival was 85.8% [95% confidence interval (CI) 81.0-90.0] at 1-year, 67.3% (95% CI 61.1-72.6%) at 5-year, and 46.1% (95% CI 39.4-52.6%) at 10-year follow-up. Age, preoperative New York Heart Association Class III or IV, a history of renal failure, and recurrence of MR expressed as a time-dependent variable [HR 3.28 (1.87-5.75), P < 0.001], were independently associated with an increased mortality risk. Female gender, a history of ST-elevation myocardial infarction, a preoperative QRS duration ≥120 ms, a higher preoperative MR grade, and a higher indexed left ventricular end-systolic volume were independently associated with an increased likelihood of recurrent MR. CONCLUSION: Mitral valve repair for functional ischaemic MR resulted in a low incidence of recurrent MR with favourable clinical outcome up to 10 years after surgery. Presence of recurrent MR at any moment after surgery proved to be independently associated with an increased risk for mortality.


Assuntos
Insuficiência da Valva Mitral/cirurgia , Idoso , Procedimentos Cirúrgicos Cardíacos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/mortalidade , Recidiva , Estudos Retrospectivos , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
13.
J Cardiothorac Vasc Anesth ; 33(12): 3273-3280, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31350152

RESUMO

OBJECTIVES: Patients undergoing heart failure surgery are at risk for developing postoperative vasoplegia. The aim of this study was to determine the incidence, survival, and predictors of vasoplegia in heart failure patients undergoing mitral valve repair for functional mitral regurgitation and to evaluate the effect of ischemic versus non-ischemic etiology. DESIGN: Retrospective. SETTING: University medical center, single institutional. PARTICIPANTS: Heart failure patients with functional mitral regurgitation who underwent restrictive mitral annuloplasty (2006-2015). MEASUREMENTS AND MAIN RESULTS: One hundred twenty-two patients were included (48% ischemic etiology). The incidence of vasoplegia was 19% and was not influenced by mitral regurgitation etiology. Ninety-day survival rate was decreased in vasoplegic compared with non-vasoplegic patients (65% v 93%, p < 0.001). After adjusting for age, gender, and heart failure etiology, prior hypertension (odds ratio [OR] 0.28; 95% confidence interval [CI] 0.08-0.91; p = 0.034), higher creatinine clearance (OR 0.97; 95% CI 0.95-0.99; p = 0.009), and beta-blocker use (OR 0.25; 95% CI 0.09-0.73; p = 0.011) decreased the risk of vasoplegia. Anemia (OR 3.00; 95% CI 1.10-8.20; p = 0.032) and longer cross clamp (OR 1.03; 95% CI 1.01-1.04; p = 0.001), cardiopulmonary bypass (OR 1.01; 95% CI 1.00-1.02; p = 0.003), and procedure times (OR 1.01; 95% CI 1.00-1.02, p = 0.002) increased the risk of vasoplegia. CONCLUSIONS: Vasoplegia occurs in 19% of heart failure patients undergoing mitral valve repair for functional mitral regurgitation. It is associated with a poor early outcome. Prior hypertension, a higher creatinine clearance, and beta-blocker use were associated with a decreased risk of vasoplegia, whereas anemia and longer procedure times were associated with an increased risk of vasoplegia, independent of heart failure etiology.


Assuntos
Insuficiência Cardíaca/fisiopatologia , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Complicações Pós-Operatórias , Vasoplegia/etiologia , Idoso , Ecocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico , Países Baixos/epidemiologia , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Vasodilatação/fisiologia , Vasoplegia/epidemiologia , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular
14.
J Thromb Thrombolysis ; 46(4): 482, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30203248

RESUMO

The original version of this article unfortunately contained a mistake in the author name. The co-author name should be Frederikus A. Klok instead of Frederik A. Klok. The original article has been corrected.

15.
J Thromb Thrombolysis ; 46(4): 473-481, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30132244

RESUMO

The optimal antithrombotic therapy following mitral valve repair (MVr) is still a matter of debate. Therefore, we evaluated the rate of thromboembolic and bleeding complications of two antithrombotic prevention strategies: vitamin K antagonists (VKA) versus aspirin. Consecutive patients who underwent MVr between 2004 and 2016 at three Dutch hospitals were evaluated for thromboembolic and bleeding complications during three postoperative months. The primary endpoint was the combined incidence of thromboembolic and bleeding complications to determine the net clinical benefit of VKA strategy as compared with aspirin. Secondary objectives were to evaluate both thromboembolic and bleeding rates separately and to identify predictors for both complications. A total of 469 patients were analyzed, of whom 325 patients (69%) in the VKA group and 144 patients (31%) in the aspirin group. Three months postoperatively, the cumulative incidence of the combined end point of the study was 9.2% (95%CI 6.1-12) in the VKA group and 11% (95%CI 6.0-17) in the aspirin group [adjusted hazard ratio (HR) 1.6, 95%CI 0.83-3.1]. Moreover, no significant differences were observed in thromboembolic rates (adjusted HR 0.82, 95%CI 0.16-4.2) as well as in major bleeding rates (adjusted HR 1.89, 95%CI 0.90-3.9). VKA and aspirin therapy showed a similar event rate of 10% during 3 months after MVr in patients without prior history of AF. In both treatment groups thromboembolic event rate was low and major bleeding rates were comparable. Future prospective, randomized trials are warranted to corroborate our findings.


Assuntos
Aspirina/uso terapêutico , Fibrinolíticos/uso terapêutico , Anuloplastia da Valva Mitral/métodos , Vitamina K/antagonistas & inibidores , Idoso , Aspirina/efeitos adversos , Procedimentos Cirúrgicos Cardíacos , Feminino , Fibrinolíticos/efeitos adversos , Hemorragia/induzido quimicamente , Hemorragia/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Anuloplastia da Valva Mitral/efeitos adversos , Estudos Retrospectivos , Tromboembolia/prevenção & controle
18.
Heart Vessels ; 31(5): 795-806, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26129868

RESUMO

Patients with bicuspid aortic valve (BAV) and patients with Marfan syndrome (MFS) are more prone to develop aortic dilation and dissection compared to persons with a tricuspid aortic valve (TAV). To elucidate potential common and distinct pathways of clinical relevance, we compared the histopathological substrates of aortopathy. Ascending aortic wall biopsies were divided in five groups: BAV (n = 36) and TAV (n = 23) without and with dilation and non-dilated MFS (n = 8). General histologic features, apoptosis, the expression of markers for vascular smooth muscle cell (VSMC) maturation, markers predictive for ascending aortic dilation in BAV, and expression of fibrillin-1 were investigated. Both MFS and BAV showed an altered distribution and decreased fibrillin-1 expression in the aorta and a significantly lower level of differentiated VSMC markers. Interestingly, markers predictive for aortic dilation in BAV were not expressed in the MFS aorta. The aorta in MFS was similar to the aorta in dilated TAV with regard to the presence of medial degeneration and apoptosis, while other markers for degeneration and aging like inflammation and progerin expression were low in MFS, comparable to BAV. Both MFS and BAV aortas have immature VSMCs, while MFS and TAV patients have a similar increased rate of medial degeneration. However, the mechanism leading to apoptosis is expected to be different, being fibrillin-1 mutation induced increased angiotensin-receptor-pathway signaling in MFS and cardiovascular aging and increased progerin in TAV. Our findings could explain why angiotensin inhibition is successful in MFS and less effective in TAV and BAV patients.


Assuntos
Aorta/patologia , Aneurisma Aórtico/etiologia , Dissecção Aórtica/etiologia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/complicações , Síndrome de Marfan/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/metabolismo , Dissecção Aórtica/patologia , Aorta/química , Aneurisma Aórtico/metabolismo , Aneurisma Aórtico/patologia , Valva Aórtica/patologia , Apoptose , Doença da Válvula Aórtica Bicúspide , Biomarcadores/análise , Biópsia , Dilatação Patológica , Feminino , Fibrilina-1/análise , Doenças das Valvas Cardíacas/patologia , Humanos , Imuno-Histoquímica , Masculino , Síndrome de Marfan/patologia , Pessoa de Meia-Idade , Músculo Liso Vascular/química , Músculo Liso Vascular/patologia , Necrose , Proteínas Proto-Oncogênicas c-kit/análise , Adulto Jovem
19.
Echocardiography ; 33(10): 1458-1464, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27343211

RESUMO

AIMS: Extent of left ventricular (LV) reverse remodeling after aortic valve repair or replacement (AVR) may differ between patients operated for acute aortic regurgitation (AR) and chronic AR. The aim of this study was to compare changes in LV volumes and function between patients with acute and chronic AR who underwent AVR. METHODS AND RESULTS: A total of 98 patients (54±15 years, 61% men) with acute (n=21) or chronic AR (n=77) were included in the present retrospective evaluation. LV volumes, LV ejection fraction, and global longitudinal strain indexed for LV end-diastolic volume (GLSi) were assessed preoperatively and after a median follow-up of 28 months (interquartile range: 17-66 months). Patients with acute AR tended to have smaller preoperative LV end-diastolic volume compared with chronic AR (156±15 vs 183±6 mL; P=.070). Both in patients with acute and chronic AR, significant LV reverse remodeling with sustained reduction in LV volumes occurred during follow-up with a significant smaller LV end-diastolic volume in acute AR compared with chronic AR (106±8 vs 128±5 mL; P=.032). Preoperative and postoperative LV ejection fractions were not significantly different between groups. In contrast, GLSi was better in patients with acute AR compared with chronic AR before AVR (-1.34±0.20 vs -0.96±0.07%/10 mL; P=.042) and during follow-up (-1.65±0.16 vs -1.29±0.07%/10 mL; P=.017). CONCLUSIONS: After AVR, LV reverse remodeling occurs both in patients with acute and chronic AR. However, LV end-diastolic volume was more reduced and GLSi was more preserved during follow-up in acute AR than in chronic AR.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/efeitos adversos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Remodelação Ventricular , Doença Aguda , Insuficiência da Valva Aórtica/complicações , Doença Crônica , Ecocardiografia , Feminino , Seguimentos , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento
20.
Crit Care Med ; 43(2): 373-81, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25599464

RESUMO

OBJECTIVES: Risk assessment in ICU patients using commonly used prognostic models may be influenced using different data definitions and by errors in data collection. We investigated whether a set of biomarkers (procalcitonin, MR-pro-adrenomedullin, CT-pro-endothelin-1, CT-pro-arginine vasopressin, and MR-pro-atrial natriuretic peptide), alone or as a panel, could be useful in postoperative risk assessment for hospital mortality in comparison with the Acute Physiology and Chronic Health Evaluation IV score. DESIGN: In a prospective observational cohort study, we analyzed 800 consecutive patients undergoing elective cardiac surgery. We assessed biomarker levels on admission to the ICU and every 6 hours thereafter for 24 hours. For every postoperative time point and for every biomarker, we determined the predictive value for hospital mortality and made a comparison with the Acute Physiology and Chronic Health Evaluation IV score. SETTING: Intensive care of an academic referral hospital. PATIENTS: A total of 800 consecutive patients undergoing elective cardiac surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: MR-pro-adrenomedullin is a good predictor of mortality (c-statistic at time point 6 hr after admission to the ICU, 0.940; 95% CI, 0.918-0.956) and performed better than the Acute Physiology and Chronic Health Evaluation IV score (c-statistic, 0.842; 95% CI, 0.811-0.868). The c-statistic did not change significantly on the time points 6, 12, and 18 hours after admission. Using a cutoff value for proadrenomedullin taken 6 hours after admission on ICU (time point 2) of 3.2 nmol/L sensitivity was 81.8% and specificity 93.9%, the positive likelihood ratio was 13.3, positive predictive value was 31.0%, and negative predictive value was 99.4%. Patients with a MR-pro-adrenomedullin above this cutoff level had an odds ratio of 68.9 (95% CI, 22.2-213.1) for not surviving their hospital stay. The other biomarkers had less predictive power. CONCLUSIONS: In elective cardiac surgery, MR-pro-adrenomedullin measured between 6 and 18 hours after admission to the ICU is a better predictor of hospital mortality in comparison with the Acute Physiology and Chronic Health Evaluation IV score.


Assuntos
APACHE , Adrenomedulina/sangue , Procedimentos Cirúrgicos Cardíacos/mortalidade , Mortalidade Hospitalar , Unidades de Terapia Intensiva/estatística & dados numéricos , Precursores de Proteínas/sangue , Centros Médicos Acadêmicos , Idoso , Biomarcadores , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Prognóstico , Estudos Prospectivos , Medição de Risco , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa